RSLOGIX5000 MSG CompactLogix to CompactLogix Ethernet Comm

แชร์
ฝัง
  • เผยแพร่เมื่อ 2 ธ.ค. 2020
  • If this video is helpful, please like, share and subscribe to my channel! Thank you.
    MSG on CompactLogix (1769-L33ER) to read/write data to CompactLogix (1769-L30ER-NSE)
    1. Message Type: CIP Data Table Read
    2. Message Type: CIP Data Table Write

ความคิดเห็น • 17

  • @vamshikk8843
    @vamshikk8843 ปีที่แล้ว +1

    Thank you for sharing the knowledge

    • @SYPHOANG
      @SYPHOANG  ปีที่แล้ว

      @Vamshi kk: My pleasure. Thank you for subscribing to my channel.

  • @albertocortes6598
    @albertocortes6598 2 ปีที่แล้ว +1

    Awesome my friend, thanks so much, it's very helpful.
    very clear.

    • @SYPHOANG
      @SYPHOANG  2 ปีที่แล้ว

      @Alberto Cortes: Glad to hear that! Thank you for subscribing to my channel.

  • @dennisjiu1771
    @dennisjiu1771 3 ปีที่แล้ว +1

    Step by step. Good as always. So the two PLCs just are simply connected by a CAT5 with RJ45 connectors? THANK YOU.

    • @SYPHOANG
      @SYPHOANG  3 ปีที่แล้ว

      @Dennis Jiu: Yes, you can do it with just a cat5 cable. But please note this is CIP communication only between Allen Bradley PLC's. You still need Modbus card for generic communication between Allen Bradley and non-Allen Bradley PLC such as Schneider or Idec PLC's. Hopefully this fully answers your question.

    • @ManuelMartinez-rz5nv
      @ManuelMartinez-rz5nv ปีที่แล้ว

      @@SYPHOANG Hello and thank you for the information... If I want to send data to a server, do I have to use the modbus card? I have a compactlogix. Regards.

    • @SYPHOANG
      @SYPHOANG  ปีที่แล้ว

      @@ManuelMartinez-rz5nv :Yes, you need a "Prosoft" module for Modbus communication. It can be either MVI69-MCM for Modbus RTU (serial) or MVI69-MNET for Modbus TCP (ethernet). Prosoft has a lot of good informative videos for the configuration instructions. Thank you for subscribing to my channel. Hopefully my information is helpful for what you are looking for :)

    • @ManuelMartinez-rz5nv
      @ManuelMartinez-rz5nv ปีที่แล้ว

      @@SYPHOANG Hello again, of course your help is useful to me. I have a stratix 5700 without NAT, i read that it must have NAT to send data to the server, that's true?

    • @SYPHOANG
      @SYPHOANG  ปีที่แล้ว

      @@ManuelMartinez-rz5nv : To be honest, I am not familiar with NAT. From my experience, if NAT is a protocol NOT from Allen Bradley, you might need a specific NAT module for communication with NAT devices.

  • @alansosa1681
    @alansosa1681 4 หลายเดือนก่อน

    Ing good video, do you have any idea how to get the status of the ports of my PLC is a compactlogix with 2 ports but I would like to know their status ok do you know with what instruction I can do it? any advice I would appreciate it! new sub!

    • @SYPHOANG
      @SYPHOANG  4 หลายเดือนก่อน

      @alansosa1681: Thank you for subscribing to my channel. From my experience I don't think it's possible. But Maybe I am wrong. I will need to do some research when my schedule allows. I'll keep you posted. Once again thank you for your support to my channel.

  • @Sparkies...
    @Sparkies... 3 ปีที่แล้ว +1

    hi
    A very informative video
    I need to log date and time in RSLOGIX 5000 at daily interval and display on HMI for duration of 7 days
    can you please help me on the above

    • @SYPHOANG
      @SYPHOANG  3 ปีที่แล้ว +1

      @Ashniel Kumar: I think you need to write your own code. I did it once. It is not very difficult but it also is not easy.

    • @Sparkies...
      @Sparkies... 3 ปีที่แล้ว

      @@SYPHOANG thanks mate
      I managed to log the data using ffl n ffu instructions
      Any help to log the date
      Thanks again

  • @ganiulhasan4461
    @ganiulhasan4461 ปีที่แล้ว

    whice softwere you use for programming?

    • @SYPHOANG
      @SYPHOANG  ปีที่แล้ว

      @Ganiul Hasan: Thank you for your support to my channel. It’s Studio5000 Logic Designer or Rslogix5000.