How to Upload or Download programming in ABB Variable Frequency Drives

แชร์
ฝัง
  • เผยแพร่เมื่อ 13 ก.ค. 2016
  • It is easy to upload or download the programming in an ABB VFD if you follow a few basic steps.
    Support the channel by becoming a Patreon: / systemcontroltech
    Here are some of the things I keep in my tool bag.
    Backpack: amzn.to/2tDnYsC
    My screwdriver: amzn.to/2uPyIDV
    Small fuse puller: amzn.to/2uPIdDk
    Combination fuse puller: amzn.to/2vB0dPf
    Adjustable wrench: amzn.to/2us3akS
    USB to Serial converter: amzn.to/2vAKHTD
    Network cable: amzn.to/2vBpJE0
    Network switch: amzn.to/2eHsIa7
    Hex Key set: amzn.to/2eHvA6C
    Fluke meter: amzn.to/2tDaZHj
    Fluke temperature meter: amzn.to/2tDxnQO
    Dell 32 bit laptop: amzn.to/2us2Z9n
    Serial cable: amzn.to/2eHvyf8
    Johnson Controls DX-9100-8454 amzn.to/38VgLni
    Johnson Controls DX-9100-8990 Back Panel: amzn.to/2IPQa0H
    Johnson Controls AS-UNT110-1 - UNT Controller amzn.to/32CVnBB
    Johnson Controls, Inc. Unt Series Unitary Controller amzn.to/2SpZCM9
    METASYS AP-VMA-1440-0 APVMA14400, VMA Controller, amzn.to/2St5eW3
    Johnson Controls, Inc. Fx Vma amzn.to/2XWEPFS
    Johnson Controls Metasys NAE MS-NAE5521-0 amzn.to/2Yhyvbn
    TRENDnet USB to Serial Converter, amzn.to/2JOxH4y
    Johnson Controls T-4000-119 Allen Head Adjusting Tool: amzn.to/2Ygf7LS
    Johnson Controls T8590 Residential High-Resolution Color Touch Screen Digital Room Thermostat amzn.to/2JVUhZf
    Johnson Controls A99BB-600C Penn Series A99 PTC Temperature Sensor amzn.to/2Ycet1R
    Johnson Controls P70LB-6C Dual Pressure Control, SPST amzn.to/2YhO8zq
    Johnson Controls VA-4233-AGA-2 Electric Actuator, amzn.to/2JVVcZH
    JOHNSON CONTROLS METASYS MS-FEC2610-0 MS-FEB2610-0 CONTROLLER amzn.to/2JT1Qj8
    Johnson Controls M9220-GGA-3 amzn.to/32HRVpm
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 86

  • @20antman
    @20antman 3 ปีที่แล้ว +2

    Bro you saved my ass 1am up on a rooftop. You were spot on. I was working on a York chiller so I needed the password!!!!!

  • @smallgoon
    @smallgoon 5 ปีที่แล้ว

    Thanks for the video, quick and painless

    • @Systemcontroltech
      @Systemcontroltech  5 ปีที่แล้ว

      Thanks for watching.

    • @ishukaushikvideo6120
      @ishukaushikvideo6120 ปีที่แล้ว

      Hello sir
      I am an electronic industrial engineer and Repairing all make vfd 1kw to 1000kw at components levels and can installation vfds at different different applications so do you have any requirement for this profile.

  • @bifesidonie1119
    @bifesidonie1119 4 ปีที่แล้ว

    Thanks so much for the inform. How do u change the settings when the VFD is showing alarm

    • @Systemcontroltech
      @Systemcontroltech  3 ปีที่แล้ว

      Press exit and it should allow you to make changes as long as the drive itself is in stop mode

  • @74lukeleng
    @74lukeleng 6 ปีที่แล้ว

    Is there a way to add reverse rotation to the soft keys? My old drive was able to switch motor direction. the new HVAC does not seem to have that option? Thanks

    • @Systemcontroltech
      @Systemcontroltech  6 ปีที่แล้ว

      Yes I believe their may me. There is a direction button on some of them already Depending on the firmware and macros for the particular drive.

  • @LT_Commander_Data
    @LT_Commander_Data 5 ปีที่แล้ว

    Thank you for the video! Thank you!

  • @lancegust2399
    @lancegust2399 3 ปีที่แล้ว

    Thanks for the information. I uploaded to the panel from a working drive and downloaded it to the new one, but the unit wont run in Auto or Hand (when I press hand it just goes to OFF) and I am missing a lot of the Parameters that are there when I look at the working drives, any advice?

    • @Systemcontroltech
      @Systemcontroltech  3 ปีที่แล้ว

      Make sure your enable contacts are closed on whatever you use to start the drive

  • @mangodfrey9991
    @mangodfrey9991 2 ปีที่แล้ว

    Thanks for sharing I get confused a bit on uploading parameters back up we uploading from where.

  • @SpanglishBear
    @SpanglishBear 5 ปีที่แล้ว

    Hey nice video, I've got a question, does this backup also saves parameters from a FENA-01 module, like IP's and that sort? I have a ACS355 driver and a FENA-01 module that its broken, I just want to change the fena module to another one but don't want to set and put every single parameters or addresses again.

    • @Systemcontroltech
      @Systemcontroltech  5 ปีที่แล้ว

      It should save all of the option settings for the VFD.

    • @ishukaushikvideo6120
      @ishukaushikvideo6120 ปีที่แล้ว

      Hello sir
      I am an electronic industrial engineer and Repairing all make vfd 1kw to 1000kw at components levels and can installation vfds at different different applications so do you have any requirement for this profile.

  • @headfulpro
    @headfulpro 8 ปีที่แล้ว +3

    Interesting! Thanks for sharing! One question comes to my mind: when you have uploaded to panel, then you just take the screen and transfer it to the other drive then download back?

    • @Systemcontroltech
      @Systemcontroltech  8 ปีที่แล้ว +1

      +Sylvain Meunier If the motors and drives are identical you can. If you are using communication you will need to correct the network address.

    • @lancegust2399
      @lancegust2399 3 ปีที่แล้ว

      @@Systemcontroltech how do you correct the network address?

    • @ishukaushikvideo6120
      @ishukaushikvideo6120 ปีที่แล้ว

      Hello sir
      I am an electronic industrial engineer and Repairing all make vfd 1kw to 1000kw at components levels and can installation vfds at different different applications so do you have any requirement for this profile.

  • @longvehoanguyen1479
    @longvehoanguyen1479 7 ปีที่แล้ว

    Can you just connect the computer to the computer using modbus .. to read the A, V values displayed on the computer ... on the abb acs550?

    • @Systemcontroltech
      @Systemcontroltech  4 ปีที่แล้ว

      If you have the correct connection cable and the correct software you can set them up on the computer.

  • @1612ydraw
    @1612ydraw 7 ปีที่แล้ว

    Great Video. When i attempt to upoad parameters to panel I get Alarm A5020. Do you know if this is another internal protection.
    Also, I am attempting this on the Basic Control Panel. It is controlling a fan blower on Atlas Copco dessicant dryer. Thanks.

    • @Systemcontroltech
      @Systemcontroltech  7 ปีที่แล้ว +1

      +1612ydraw make sure that you press the stop button on the drive before uploading. That should be the only thing that would cause an error other than a problem with the drive

    • @1612ydraw
      @1612ydraw 7 ปีที่แล้ว

      Thank you for the assistance. It turned out it was in remote control to receive an external speed request over modbus. Put it in local and carried your instructions. perfect. thanks again. do you have a video on drive window light ??

    • @Systemcontroltech
      @Systemcontroltech  7 ปีที่แล้ว

      +1612ydraw not yet.

    • @markgonzales9838
      @markgonzales9838 6 ปีที่แล้ว

      HVAC schematics

  • @vmo8105
    @vmo8105 ปีที่แล้ว

    Thanks for your help 👍

  • @roslanmatnor5821
    @roslanmatnor5821 7 ปีที่แล้ว

    Good Info, Thanks

  • @calijguyman
    @calijguyman 8 หลายเดือนก่อน

    Thanks man!

  • @shuhaibmohammed9338
    @shuhaibmohammed9338 2 ปีที่แล้ว

    I retrieve data from a ABB vfd drive ACS850 to the panel and using that control panel I try to download to another drive which have same spec and function ( it's an standby drive) but I it's showing an error after all the download process over high limit and I have only option to select is ready when click ready It seems like ready ..but when I try to run I couldn't get the output running command is on..output is zero..I think it's an parameter issue..please help me to sort out this

    • @Systemcontroltech
      @Systemcontroltech  2 ปีที่แล้ว

      Theres a difference in the firmware between the two drives even though they're both 550s. I've had that same issue. Your better off setting up the new drive from scratch

  • @smallgoon
    @smallgoon 5 ปีที่แล้ว

    So which one saves to the drive and which one reads from the drive? I noticed you did upload two times and didn't see a download.

    • @Systemcontroltech
      @Systemcontroltech  5 ปีที่แล้ว

      Upload saved the program to the panel and download loads the program into the drive itself.

  • @SilverC8andDroppedC10
    @SilverC8andDroppedC10 3 ปีที่แล้ว

    Can you remove the panel with the drive running OR do you have to turn off the drive to prevent data loss? Thanks for the great video.

    • @Systemcontroltech
      @Systemcontroltech  3 ปีที่แล้ว +1

      It can be removed while running

    • @ishukaushikvideo6120
      @ishukaushikvideo6120 ปีที่แล้ว

      Hello sir
      I am an electronic industrial engineer and Repairing all make vfd 1kw to 1000kw at components levels and can installation vfds at different different applications so do you have any requirement for this profile.

  • @aliabd-alhalim4695
    @aliabd-alhalim4695 3 ปีที่แล้ว

    Hi sir I had a malfuction i cant desid if the fualt from vfd or controller ..couse when u press to change the rotaiton dosent go back only REV how can fix it isit parometer or fualt from electrical panel...thanks

    • @Systemcontroltech
      @Systemcontroltech  3 ปีที่แล้ว

      There's a lot of possibilities. Make sure it's set up properly in the drive for reverse operations

    • @aliabd-alhalim4695
      @aliabd-alhalim4695 3 ปีที่แล้ว +1

      Iwuld like to thank u for ur replay .Ifound the seting parometer group20 from vfd abb manual 1003 now it works

  • @mohamedelmakkaouy9518
    @mohamedelmakkaouy9518 7 ปีที่แล้ว

    how can i download the parametres to an external flash drive ( usb , memory card ...)

    • @Systemcontroltech
      @Systemcontroltech  7 ปีที่แล้ว

      +Mohamed El Makkaouy you would need the abb software tool on your computer. You could then upload the parameters to your computer. Good luck.

    • @mohamedelmakkaouy9518
      @mohamedelmakkaouy9518 7 ปีที่แล้ว

      i already installed the software, i dont know the reference of the cable that i should use to connect the control panel with my pc , i have a CDP312 control pannel of a ACS800 drive,

  • @jkj1459
    @jkj1459 7 ปีที่แล้ว

    Thank you sir

    • @Systemcontroltech
      @Systemcontroltech  7 ปีที่แล้ว

      +james kutty Joseph you're welcome and thanks for watching

  • @saahilraeen9055
    @saahilraeen9055 5 ปีที่แล้ว

    Sir I have a ACH 550 vfd. I use for condenser fan. My chiller panel giving demands 100% but my vfd run only on 60% I set vfd maximum 100% please help!!! Thanks for uploading video...

    • @Systemcontroltech
      @Systemcontroltech  5 ปีที่แล้ว

      Check to see what your signal is. It will either be 0-10vdc or 4-20ma. There is a dip switch just above the terminals on your drive that must be set to match the type of signal.

    • @saahilraeen9055
      @saahilraeen9055 5 ปีที่แล้ว

      Thanks sir for your feed back, panel to control input power comming 6v same befor and deep switch it has same before setting I think my vfd not going 6th and 7th speed I don't know what's wrong in parameter!!!!

  • @johndsick123
    @johndsick123 5 ปีที่แล้ว

    thanks good video

  • @ahmadsaz499
    @ahmadsaz499 ปีที่แล้ว

    Abb 550 drive massage display drive not responding what is the solution?

    • @Systemcontroltech
      @Systemcontroltech  ปีที่แล้ว

      Cycle power. Make sure the panel is properly seated. If it is and the drive doesn't recover when you power it up, the control board is bad.

  • @derrickgarcia303
    @derrickgarcia303 3 ปีที่แล้ว

    I get a message no start inhibit granted when I’m trying to copy the parameters. Please help.

    • @Systemcontroltech
      @Systemcontroltech  3 ปีที่แล้ว +1

      Switch the drive to local control and press the stop button

    • @derrickgarcia303
      @derrickgarcia303 3 ปีที่แล้ว +1

      @@Systemcontroltech thank you!

  • @abuilyasabuassiya7691
    @abuilyasabuassiya7691 5 ปีที่แล้ว

    Thanks

  • @thomastrang4815
    @thomastrang4815 ปีที่แล้ว

    Its transcript: Hey guys, in this video, I'm going to show you how to upload a parameter in an ABB VFD, as well as how to download those parameters. Well, it's a really good way if you have two motors that are identical sitting side by side, such as like pumps or cooling tower fans or that sort of thing. This is one way that will speed up a little bit of the setup if you are adding or replacing a drive that is identical to one that is already there. Also, I'm going to show you how to disable the override mode, which is something that we see in your drives, which as we all know is an ABB drive with a York or Johnson control sticker on it. Sometimes if you try to download and the parameters into your drive, what it will do is it will actually give you an error. So, I want to show you how to disable that override mode where you can download it. The first step in downloading a drive is you must press the off button; it will not let you upload or download a program if the drive is running. So, the first step is to press the off button, then simply hit the menu button go into parameters and scroll down to parameter backup. Once you go to the parameter backup, you select that and then select Upload to panel. And that will upload all of the parameters within the drive to the panel. I recommend you do this anytime you set up a drive. Anytime you are expecting to make changes that you're not sure if they're going to work or anytime that you make any adjustments to the drive’s operation, you want to back that up and save a copy. In case something happens if you have to change it now this stuff will work very well and speeding up the change out of the drive, you can simply then back out and once you back all the way out you press the auto button, and the drive should restart with no problem. Now if the override mode is enabled, you will get an error if you try to download some drives this is common with the orc drives as well as you know the Johnson control drives which there an ABB drive with a York or Johnson control sticker on them. And you can see here scroll into the menu to try to download the drive and I get an error you can see the error code here override mode is not allowed override mode enabled. So, we are going to show you how to disable that and it will not let you download it until you do so you go down in your menu to group 17 and 1701. I tried to go into there and gives me an error of course you once again. What we have to do before we can do that is we must scroll down and enter a password into group 1704. That password value is 358. And here I overshot it a little bit, so we scroll back down and run our numbers up to 358. And once we get those values set, I press the save button and it brings me back to this menu here I then scroll down to the next one and you can see here override mode is already off as I've already turned it off on this one once again you must hit the stop button before you can make any changes go in here you can see this is where you would turn the override mode on and off is currently off on this drive. This is after I had already turned it off and loaded the program. So, we go back into 1701 and then we set this to not selected. Once we have that done, we can simply back all the way out from this particular Menu Group. And once this is all disabled, we will then be able to go in to reload the parameters into this drive. Once again doing this is very helpful if you are changing out a drive you can see here once I press the Go back into the menu that I am able to download the drive with no issues whatsoever it simply once that's turned off and lets me download it with no problem. Once it's successful, you can just back all the way out and press your auto start and the drive will restart as normal. guys hope you liked the video hopefully that it is helpful to you. I would appreciate it if you would give it a thumbs up also be sure to drop me any comments and questions down below and be sure to subscribe. Thanks for watching!

  • @prativindghogare6235
    @prativindghogare6235 6 ปีที่แล้ว

    Nice

  • @ajazhaider5866
    @ajazhaider5866 7 ปีที่แล้ว

    how I check my drive parameter

    • @Systemcontroltech
      @Systemcontroltech  7 ปีที่แล้ว

      +Ajaz Haider motor information needs to match the nameplate information on the motor

  • @msoliday5570
    @msoliday5570 3 ปีที่แล้ว

    Need help with a new drive and motor install

  • @epicone2449
    @epicone2449 4 ปีที่แล้ว

    When I tried doing this it said local mode not on.

    • @Systemcontroltech
      @Systemcontroltech  4 ปีที่แล้ว

      You have to put the drive in local mode before you start

  • @derrickgarcia303
    @derrickgarcia303 ปีที่แล้ว

    I accidentally pushed the download the full set on a working VFD. Now it doesn’t work

  • @longvehoanguyen1479
    @longvehoanguyen1479 7 ปีที่แล้ว

    Can anyone point me to the installation of the machine just like the first time I bought it .... because I installed messy but installed...

    • @Systemcontroltech
      @Systemcontroltech  7 ปีที่แล้ว

      +longvehoa nguyen are you talking about resetting to factory defaults or initial wiring?

    • @longvehoanguyen1479
      @longvehoanguyen1479 7 ปีที่แล้ว

      How to reset the default machine ... can you help me?

    • @longvehoanguyen1479
      @longvehoanguyen1479 7 ปีที่แล้ว

      You help me default to abb acs550 machine

    • @longvehoanguyen1479
      @longvehoanguyen1479 7 ปีที่แล้ว

      You can show how to read the value directly from the inverter to the computer (by modbus)

    • @Systemcontroltech
      @Systemcontroltech  7 ปีที่แล้ว

      +longvehoa nguyen you will need to have the correct communication card installed in the drive. Connect your communications network and configure the parameters in the drive. You should then be able to discover the points within the drive within metasys

  • @vbmb
    @vbmb ปีที่แล้ว

    Such a mess just to run a fan.............

  • @daguilara9
    @daguilara9 4 ปีที่แล้ว

    Can this procedure be done between two different ABB VFDs. For example, to take configured parameters from an ACS550 to an ACS580?