Service Call | How To Diagnose A Bad Gas Valve

แชร์
ฝัง
  • เผยแพร่เมื่อ 6 ต.ค. 2024

ความคิดเห็น • 147

  • @bills6946
    @bills6946 ปีที่แล้ว +41

    Exactly right. Many guys slap in a new valve, run a cycle, take the customers check and leave. Always check output gas They are set higher at the factory to ensure ignition in most scenarios. High gas will make the furnace run hot, possibly causing hi limit shutoff and even shorten the life of the heat exchanger. You are a technician, sir.

    • @kingvick5914
      @kingvick5914 11 หลายเดือนก่อน +1

      Were can I get that pressure checker

    • @yanzhang98
      @yanzhang98 10 หลายเดือนก่อน +1

      Not everyone has a pressure checker.

    • @rorynelson7548
      @rorynelson7548 10 หลายเดือนก่อน

      I worked on one last night, board was sending power to gas valve and operating correctly. Checked output pressure side, nothing came through

    • @cleansebob1
      @cleansebob1 9 หลายเดือนก่อน

      I was wondering if we need to adjust the pressure when ALL of the gas appliances are on, so that pressure to furnace doesn't drop when that occurs? Or am I overthinking it?

    • @rorynelson7548
      @rorynelson7548 9 หลายเดือนก่อน

      @@cleansebob1 yes you are supposed to. It will say to in the manuals too. Depending on how many units are gas in a house, I may not worry about it because there's typically very little drop in pressure with other units running

  • @stevemiles5012
    @stevemiles5012 9 หลายเดือนก่อน +8

    SO thankful for this video! HVAC contractor said I need a new furnace and immediately sent out a salesman. After telling them I wasn’t interested I tore into myself and was able to diagnose and fix the problem. This video helped a fair amount. Furnace will eventually need to be replaced but for now this saved me thousands!

    • @yuyuyu9029
      @yuyuyu9029 8 หลายเดือนก่อน

      Hate sales man in blue collar jobs

  • @fonzario
    @fonzario 6 หลายเดือนก่อน +1

    Thank you for the video. Helped me diagnose my problem. I was just about to order a new control board when I saw your video. I was able to isolate the problem to be my gas valve. I was unable to get a 24 volt measurement at the out of my board until I disconnected the wires from my gas valve and measured it that way. That told me the board was doing its job. Inducer motor, pressure switch and igniter all performed fine. I ordered a gas valve online because outlets in town will only sell to HVAC contractors.

  • @kenwhitehead5130
    @kenwhitehead5130 9 หลายเดือนก่อน +2

    Great video... I tried everything in your video and still no help. I actually watched several other videos on diagnosing your HVAC system to no avail.
    Well, I was about to give up and call a serviceman for repair. Then my wife started making lunch and noticed there was no gas to the stove.
    I remembered we have an automatic shutoff on the outside gas meter. We live in earthquake country so I installed this valve 30 years ago. We recently had a swarm of earthquakes and the valve shut down our gas line. A quick reset of the earthquake valve and everything was up and running again. No harm no foul.

  • @samyz1660
    @samyz1660 ปีที่แล้ว +5

    Amazing gas valve video. I do have a request please. I'm a new tech , I came across valves not sure where to plug my manometer. Could you please do a video of different gas valves and their port to connect. It could be just a pictures of valves. I like the quality of your videos and most importantly, you show the step by step process. Thank you.

  • @tylerlivengood9970
    @tylerlivengood9970 ปีที่แล้ว +8

    Make sure to check incoming gas pressure before final diagnosis. Most gas valves are internally checked and will not open if gas pressure is too far off. Not super common, but does happen.

  • @delu534
    @delu534 10 หลายเดือนก่อน +3

    Thank you for the video. Our furnace works fine as long as it gets a break between uses of around an hour. Tech said it was the "Smart Valve" which will cost around $1000 to replace. Anything else it could be? Why would it still work when it gets a break but not fire up if you try to use it without enough of a break in between?

    • @ZacharyMarshall-p4e
      @ZacharyMarshall-p4e 8 หลายเดือนก่อน +1

      It’s just working intermittently, around $1000 is the going rate for gas valves. $850 to $1000 is what I charge.

  • @waynevaughn3107
    @waynevaughn3107 5 หลายเดือนก่อน

    Thank you ! So helpful. Helped me pinpoint the gas valve and find corrosion on the terminals cleaning them got it working again! Thank you so much!👍🏽

  • @joedixon8804
    @joedixon8804 7 หลายเดือนก่อน

    Good video. I been a resi installer for six yrs now. Trying to switch to service. Gonna replace a gas valve and control board on a 90% amana tomm

  • @druwoodson3494
    @druwoodson3494 10 หลายเดือนก่อน +1

    Great video, needed a good refresher since I don’t repair many units being an independent handyman. I am HVAC qualified, few jobs in between. Thank you…

  • @yonasserdo5320
    @yonasserdo5320 5 หลายเดือนก่อน

    Thank you for this important and impressive knowledge you’ve shared

  • @dblackkw
    @dblackkw 9 หลายเดือนก่อน

    Excellent technician! I liked and subscribed. I don't have any issues with my heater and I am an oil heat tech but know very little about gas so you are my "go to guy" thanks for being professional keep up the great work!

  • @paulericn.mouafo6610
    @paulericn.mouafo6610 11 หลายเดือนก่อน +1

    Really helpfull tutorial.. I'm entangled in such issue with my boiler i was even considering to change it. now it looks different. Thanks so much

  • @bigpaul7085
    @bigpaul7085 8 หลายเดือนก่อน

    This video really helped ! I heard the audio click, but that must have been from the mother board ! I will test the wiring and determine if in fact it is a faulty gas valve !

  • @hughghiringhelli6657
    @hughghiringhelli6657 11 หลายเดือนก่อน +2

    Excellent video... nicely done and so very helpful!!!

  • @spook283
    @spook283 ปีที่แล้ว +1

    hey, i want to thank you for your help. your video saved me around a 1000.00 today.woke up to a cold house called the company that installed my furnace, they told me 198.00 for the guy to come out, 550.00 plus for the gas valve and another 2 to 300 for the repair. called grainger supply got the part for 130.00. they that company must think i was born last night. its a total shame how they take advantage of some people who have no idea.

    • @HVACTechTips
      @HVACTechTips  ปีที่แล้ว

      Yep. I see it all the time. Glad I could help

    • @ZacharyMarshall-p4e
      @ZacharyMarshall-p4e 8 หลายเดือนก่อน

      $850 to $1000 is what I charge, not taking advantage of customers. It’s the cost for a professional service. Glad you figured it out and saved yourself some money though.

  • @roqueherrera8471
    @roqueherrera8471 ปีที่แล้ว

    So I been doing install for 16 years and now transferring to service 🙏 for the knowledge…….

  • @salemkaresllc7309
    @salemkaresllc7309 ปีที่แล้ว +1

    Thanks for the step by step instructions

  • @cleansebob1
    @cleansebob1 9 หลายเดือนก่อน

    Excellent! Had an intermittent yesterday which cost me a control board, but, oh well...

  • @marcusdarnell3348
    @marcusdarnell3348 ปีที่แล้ว +6

    Great video! It is easier than I thought to replace an gas valve

  • @dporrasxtremeLS3
    @dporrasxtremeLS3 ปีที่แล้ว +2

    Field Pulse... Great Video! To the Point! Very enjoyable! You are very easy to follow! Subscribed awhile bad because of the great content and easy to learn! Thanks Josh!!!

  • @jorgesegura7333
    @jorgesegura7333 ปีที่แล้ว +2

    Excellent job!! Quick and easy!!!👍👍👍

  • @edbard3766
    @edbard3766 ปีที่แล้ว

    Wow, just fixed my gas valve. turn the gas screw half turn, turn it back to same position works just fine. Crazy

  • @robertoescobar007
    @robertoescobar007 9 หลายเดือนก่อน

    You're the man, respect for a great video and great explanation Sir. thank you! 🙌👏👏

  • @tillerdogg3232
    @tillerdogg3232 ปีที่แล้ว

    Good video man. I forget to turn gas back on all the time😅

  • @ernestalfa9045
    @ernestalfa9045 ปีที่แล้ว +1

    Dude that was a great explanation 10/10 good job keep it up

  • @manonfire3642
    @manonfire3642 ปีที่แล้ว +1

    Valuable video and well explained. Thanks for sharing.

  • @msalazar89
    @msalazar89 ปีที่แล้ว +2

    Also do the regulators come pre set to a specific gas psi?

  • @nicholassharp8691
    @nicholassharp8691 10 หลายเดือนก่อน

    Music blew my ears out then I could barely hear you. 😂 All good though. Thank you for posting.

  • @soloch69
    @soloch69 ปีที่แล้ว +2

    Great video keep them coming 👍🏻

  • @richardfluty3215
    @richardfluty3215 ปีที่แล้ว +2

    Is it a necessity to adjust the valve allways? Or are they generally in spec from manufacturer

    • @HVACTechTips
      @HVACTechTips  ปีที่แล้ว

      There usually close but it's recommended to always check at the first start up

  • @josemena7644
    @josemena7644 ปีที่แล้ว +1

    Thank you for the details!!!!!!!!!!
    Great job:)

  • @michaelrothman4602
    @michaelrothman4602 ปีที่แล้ว +1

    Thank you for the videos you are very talented. How do I find out the required gas pressure needed for my boiler?

    • @HVACTechTips
      @HVACTechTips  ปีที่แล้ว

      It should be printed on the valve or on the nameplate of the boiler.

    • @bills6946
      @bills6946 ปีที่แล้ว

      Look at the name plate. The information is on the plate

  • @cowgerbry
    @cowgerbry 9 หลายเดือนก่อน

    Excellent, very helpful, thank you!!!

  • @InsideOutElectronics
    @InsideOutElectronics 6 หลายเดือนก่อน

    Good video ! Thank you
    What if 24V to the gas valve is applied only for 1 or so second,
    Obviously no gas coming out and igniter is off in another 1-2 seconds.
    Wondering what does it mean ?

  • @turborsx5740
    @turborsx5740 9 หลายเดือนก่อน

    Thank you for this video! How long does the 24V stay that way after the valve opens? Thanks in advance!

  • @David_Poole
    @David_Poole 9 หลายเดือนก่อน

    The junk single stage Honeywell has valves with a grey top and small red switch will give you 24 with the leads unplugged, but when connected with short out the furnace, shut it down, then it goes into a retry. If you test for voltage with the leads hooked up to the valve, you'll always see zero. Leading you to think it's a board.
    Also, I rarely see a 36J go bad. How often do you run into a failed 36J?

  • @gp3yt
    @gp3yt 7 หลายเดือนก่อน

    For the DIY homeowner, can the CAT85 Manometer be rented? Obviously needed for tuning the GV. Buying a gas valve is one thing... but if you have to buy a CAT85 Manometer... $$$$$ big bucks for just one time use.

  • @davidphil6708
    @davidphil6708 9 หลายเดือนก่อน

    Thanks for the explanation. My gas valve is getting 13v before the board sends 26v to it. My HVAC guy replaced the board and flame safety sensor and it did the same thing. Could this be the gas valve going bad or do I have wiring issues?

  • @englewood1961
    @englewood1961 ปีที่แล้ว

    Use a sharp probe on the high and medium. jumper the high to medium and with the dammit switch taped on, use an alligator jumper from the R redead and put 1
    24VAC ion the jumpered high and medium, listen for the click and the gas flow.

  • @ralphriffle1126
    @ralphriffle1126 10 หลายเดือนก่อน +1

    Wow Wow Wow! Wait you forgot one more test. If it does not open, tap on the valve several times. The reason for this is the valve might be stuck. The gas suppliers will add antifreeze to the gas from theirs storage facilities so the gas will not freeze. This can cause a little sticky build up in the valve. Once you free it your good for winter. Techs helping Techs

    • @josesoto2079
      @josesoto2079 9 หลายเดือนก่อน +1

      Thanks to your coment about gas valve stock after doing my test using a multimeter l did what you recomend in your suggestions and works!!!! Thanks, my friend!!!!

  • @bobshanery5152
    @bobshanery5152 7 หลายเดือนก่อน

    You should check the pressure of the gas before replacing the manifold. Its not common but can happen.
    The supply could be blocked or not even getting gas.

  • @Alex-y2p5u
    @Alex-y2p5u 9 หลายเดือนก่อน

    thank you very much for this video

  • @jorgedelaossa9899
    @jorgedelaossa9899 ปีที่แล้ว +1

    Thank you so much

  • @jashimuddin7716
    @jashimuddin7716 8 หลายเดือนก่อน

    Thank you very helpful video

  • @lisabennett5078
    @lisabennett5078 10 หลายเดือนก่อน

    Good video, thank you!

  • @josereynaga
    @josereynaga ปีที่แล้ว +1

    Hello friend, I have a question, my heater turns on but after 5 to 10 minutes Riley cuts off the gas and after 5 minutes I open it again and it turns on again and I changed the flame sensor and it does the same to me. It will be the tablet that Riley already it does not work

  • @BassaForte
    @BassaForte 11 หลายเดือนก่อน

    Good video, but what is the size of the tube adapter did you use? I have the same valve but I am not sure what size tube I need (although I guess I could try to fit a caliper in there to measure it...)

  • @pablobon5957
    @pablobon5957 8 หลายเดือนก่อน

    Amazing video thx man

  • @TimMetling
    @TimMetling 4 หลายเดือนก่อน

    How about a Lennox two stage gas valve? How do you know it is going into high fire?

  • @jaimegonzalez6926
    @jaimegonzalez6926 10 หลายเดือนก่อน

    Very well done awesome video.

  • @westonwatts6606
    @westonwatts6606 8 หลายเดือนก่อน

    I like this guy!

  • @shaunwagner6229
    @shaunwagner6229 ปีที่แล้ว +3

    im having issues now where ive found a bad 2 stage gas valve, got a replacement and now the replacement isnt working. reading no resistance on the coil but everything else is right. no problems anywhere else in the system but for some reason this ones got me REALLY doubting myself.

    • @conspiraciesexposed7760
      @conspiraciesexposed7760 ปีที่แล้ว +1

      I’d like to know how to diagnose this ^

    • @patrickjordan8373
      @patrickjordan8373 ปีที่แล้ว

      It would be a big help to me to know what model of valve you are talking about and if you got it off the shelf or if it was shipped. The new standard of shipping is to toss a delicate piece of equipment in an oversized box with a single air pillow so that it bounces half way across the nation before it gets to you. Then when you install it you realize that you were probably better off leaving the original device in.
      What I would like to have seen in this video is some differential diagnosis of:
      Yes the inducer is running, yes the pressure switch is engaged, but what if there were intermittant problems like the inducer not being steady so that the pressure switch had minor open/closed problems that then might let the pilot light then shut it off? or the flame sensor being intermittant so that even if the mains lit that they might fail too?
      No bigger bugger than an intermittant fail.
      Lettuce know if you had any success with your valve.

  • @mousetowndude
    @mousetowndude ปีที่แล้ว +6

    Nice video Josh! Thank you for the time and effort to help others. I'm retired from the trade and remember when I was green at it, circa 1960, and needed this kind of help [ long before the internet existed]. Took me a long time to get up to your level.
    My tip is that a service tech must keep in mind that an intermittent sticky gas valve can render misleading error codes such as "check flame detector rod" or "check ignitor" when those things are perfectly fine. Intermittent troubles can be challenging for even an ace tech. 17Apr2023 8:02 PM ‹(•¿•)›

    • @HVACTechTips
      @HVACTechTips  ปีที่แล้ว

      Your spot on. Thanks for the great information. I appreciate the compliment. Like you, I never had this type of advice or help when learning this trade. That's why I do these videos. Having something like this would have been such a huge help for me. Thanks for watching.

  • @paulhu1358
    @paulhu1358 8 หลายเดือนก่อน

    Thanks!

  • @maheradous9257
    @maheradous9257 10 หลายเดือนก่อน

    Good job

  • @menymartinez4238
    @menymartinez4238 10 หลายเดือนก่อน

    Like you manometer bro question
    where did you buy that manometer pls

  • @johnnyg6448
    @johnnyg6448 10 หลายเดือนก่อน

    I got a new trans unit installed early this year , first time trying the heater and it ignited when it wants . I’m assuming it might be the valve

  • @slakjawnotsayin5451
    @slakjawnotsayin5451 9 หลายเดือนก่อน

    I have to ask, why didn't you do the pressure test with the meter and try adjusting the valve under the brass screw cap, before swapping the entire pressure valve assembly?
    Just seems kind of odd that the whole assembly would need to be changed out, when it could just be a corroded valve or something in there, that could possibly be tested and adjusted??
    I have no idea, but I couldn't help wondering that while watching the video...
    Are they that cheap, that there's no point in bothering with that, to avoid a future service call or something?

  • @austinreeves5221
    @austinreeves5221 6 หลายเดือนก่อน

    My spa heater just stoppe working. I am getting power to the leads so Im guessing its the gas valve. Hopefully it fixes it

  • @jesuscard.1675
    @jesuscard.1675 10 หลายเดือนก่อน

    A good idea would be to check the inlet gas pressure, I had an experience, I checked the power from IFC and I got the 24 volts I assumed the gas valve was bad. I replaced the gas valve, and guess what? Problem still. I checked the gas inlet pressure was above 25 WC. What was the problem, outside regulator. I told the customer call the gas company to replace the regulator, after regulator was replaced, problem solved 😊. High gas inlet pressure causes the gas valve can't open.

    • @jicalzad
      @jicalzad 9 หลายเดือนก่อน

      My HVAC tech said there was excessive moisture buildup in my gas regulator which might have froze and kept the gas from passing. He was able to get the moisture out and got my furnace up & running again. He advised me to also contact the gas company if i have another ignition lockout issue & have them look at my regulator. I'm wondering if i should just contact the gas company now anyway to have them look at it, rather than see if the problem returns.

  • @jonah8641
    @jonah8641 10 หลายเดือนก่อน +1

    Looks like the gas valve been replaced before. Why not add a drip leg on the gas line and use a gas flex. Moisture may have gotten inside the gas valve. I always tell myself why did the gas valve failed.

  • @Ray-wr2wr
    @Ray-wr2wr 9 หลายเดือนก่อน

    are replacement gas valve comes factory set up at 3.71 iwc ?

  • @l.a.m7645
    @l.a.m7645 ปีที่แล้ว

    Also make sure main gas valve is open.

  • @michaelmendez4909
    @michaelmendez4909 11 หลายเดือนก่อน

    How do I know which gas valve I can replace with if I can’t get the original one?

  • @HvAcAprentice
    @HvAcAprentice 11 หลายเดือนก่อน

    Nice video!!!👍👍

  • @StevenHill-l6g
    @StevenHill-l6g ปีที่แล้ว

    How did you know it was suppose to be set at 3.5? Where do we find that info for our furnace>? That kind of info would be nice in the vid.

    • @HVACTechTips
      @HVACTechTips  ปีที่แล้ว

      It's on the top of every gas valve.

    • @bills6946
      @bills6946 ปีที่แล้ว

      Look for the label in the furnace. It will tell you. 3.5 wc is a rule of thumb. The manufacturer gives you the exact water column needed for optimal operating temperature, safety and efficiency

  • @Ricoswavaey
    @Ricoswavaey ปีที่แล้ว +6

    Don’t forget to always make sure you have gas going to the gas valve. If you do THEN replace gas valve.

    • @HVACTechTips
      @HVACTechTips  ปีที่แล้ว +2

      Great point!

    • @Ricoswavaey
      @Ricoswavaey ปีที่แล้ว +1

      @@HVACTechTips definitely and good job btw👏

  • @Hvacmania
    @Hvacmania ปีที่แล้ว +1

    Aren't you supposed to check a relay also?

  • @tomhill9445
    @tomhill9445 9 หลายเดือนก่อน

    My valve is stuck shut. Its getting 39 to 40 vac. Is that too much ? Could that cause the failure ?

  • @rhondawestaway626
    @rhondawestaway626 10 หลายเดือนก่อน

    Will a furnace run with a bad valve?

  • @alfredo74k5blazer
    @alfredo74k5blazer 10 หลายเดือนก่อน

    Dang it!! I need to replace my gas valve 🤨

  • @roqueherrera8471
    @roqueherrera8471 ปีที่แล้ว

    Thank U

  • @billrowan1957
    @billrowan1957 8 หลายเดือนก่อน

    What if the 24v isn't sent to the valve?

  • @EdwardNg-fl9tr
    @EdwardNg-fl9tr 10 หลายเดือนก่อน

    Is 3.5 the right gas pressure for all furnaces?

    • @drcornelius8275
      @drcornelius8275 8 หลายเดือนก่อน

      Was just going to ask the same thing.....

  • @humbertoruiz4916
    @humbertoruiz4916 ปีที่แล้ว

    Gracias Guero

  • @rocker8692
    @rocker8692 10 หลายเดือนก่อน

    No combustion analysis?

  • @mikecabral7436
    @mikecabral7436 ปีที่แล้ว +1

    Could a bad gas valve cause roll out flames?

    • @bills6946
      @bills6946 ปีที่แล้ว

      Cracked heat exchanger is the usual cause. Verify by taking CO readings at supply vents in the home

  • @oso1165
    @oso1165 ปีที่แล้ว +1

    You have a combustion analyzer right in front of you but you weren't checking combustion as you were setting the gas valve outlet pressure ???

    • @HVACTechTips
      @HVACTechTips  ปีที่แล้ว

      Lol. That wasn't the point of the video I was making. A full combustion analysis was done after I filmed the gas valve replacement.

    • @oso1165
      @oso1165 ปีที่แล้ว

      @@HVACTechTips gotta do it when setting gas pressures no?

    • @HVACTechTips
      @HVACTechTips  ปีที่แล้ว +1

      No not always but it's recommended. Most technicians including myself aren't always allowed the time frame necessary to do a combustion analysis on every furnace.

    • @engineer1793
      @engineer1793 ปีที่แล้ว +2

      Must of been hot in there, see your arms were sweating

    • @HVACTechTips
      @HVACTechTips  ปีที่แล้ว +1

      Yes. It was. 😂

  • @bluwng
    @bluwng ปีที่แล้ว

    Mine is working but makes a rapid buzzing noise .

  • @palebluedot-rc5ru
    @palebluedot-rc5ru 5 หลายเดือนก่อน

    bruh? @4:23, you just gonna ignore that monster bee chillin upturned on the burner tray?

  • @SiteReader
    @SiteReader ปีที่แล้ว +2

    As the fellow below says, you need to first check that there is gas going to the valve, before you spend several hundred dollars of the customer's money changing a gas valve that might not be the problem.

  • @crs1474
    @crs1474 10 หลายเดือนก่อน +1

    Voltage on my valve jumps all over the place when the board is sending signal/voltage to it. Goes from -100 to the -190s. My multimeter is set to ACV200 setting. I switched the leads on my multimeter to the other prongs on the gas valve and same results. Does that mean my control board is the problem? It’s a RHEEM rooftop furnace.

    • @KHAOE1
      @KHAOE1 10 หลายเดือนก่อน

      Same here. My ignitor sparks but no gas. When I tested the power to the gas valve the numbers on the multimeter are all over the place when the ignitor sparks. I'm thinking my control board may be bad. Have you found the problem yet?

    • @crs1474
      @crs1474 10 หลายเดือนก่อน +2

      @@KHAOE1 Somewhat temporarily fixed it. I removed and reconnected the harness connector (the block with 9 wires) that is connected to the control board, blowing out any debris that might be on the pins on the board and connector. I made sure it was seated firmly into the board. For now that seems to be the fix until I can replace the board. Make sure you remove the breaker going to the furnace. This is on a Rheem roof unit.

    • @KHAOE1
      @KHAOE1 10 หลายเดือนก่อน

      @@crs1474 thanks.

    • @crs1474
      @crs1474 10 หลายเดือนก่อน

      @@KHAOE1 no problem. Side note. After about a week my furnace started having the same issue but disconnecting and reconnecting the same connector fixed it again.

    • @KHAOE1
      @KHAOE1 10 หลายเดือนก่อน

      @@crs1474 got it...if I replace the gas valve (Already have one on order) and it doesn't fix the problem I know it has to be the motherboard. My problem first started when it started getting cold outside (My furnace is on the roof). My furnace would not work at night but just fine during the day. I think the motherboard needs to "warm up" or something before it starts working right. Maybe need more insulation inside the unit.

  • @msalazar89
    @msalazar89 ปีที่แล้ว +1

    How much would this cost for a tech to come out and do this

    • @HVACTechTips
      @HVACTechTips  ปีที่แล้ว

      $400-$700

    • @michaelcolovos3834
      @michaelcolovos3834 ปีที่แล้ว

      ​@@HVACTechTips is that including the valve? 400-700. also why the 300 spread thanks. I need one

    • @carlostrujillo1950
      @carlostrujillo1950 3 หลายเดือนก่อน

      @@HVACTechTipsI’m watching your vd, where are you located if doesn’t bother you.

  • @rodneywallis3478
    @rodneywallis3478 11 หลายเดือนก่อน

    Defective gas valve.

  • @richardklosowski1347
    @richardklosowski1347 7 หลายเดือนก่อน

    IWe would really hear the background laughter if after installing the new valve that the gas was off to home.

  • @jericosha2842
    @jericosha2842 ปีที่แล้ว

    I always end up getting gas valves horribly stuck to the black gas orifice pipe. I end up needing to use a vice grip to yank. It's infuriating.

    • @bills6946
      @bills6946 ปีที่แล้ว

      Always use 2 Stillson wrenches. Not Channel locks. It will screw right off every time

  • @meTimetraveler
    @meTimetraveler ปีที่แล้ว

    dead bee in the drip pan

  • @gibsonfamily
    @gibsonfamily 10 หลายเดือนก่อน

    This is what my furnace is doing but i dont hear the click anymore

  • @brandonharvey7939
    @brandonharvey7939 8 หลายเดือนก่อน

    Unless your customers are asking you to convert their furnaces into a rocket that can land on the moon you are way overcharging them if you can afford to buy unnecessary test equipment that costs more than their furnace.

  • @Rik-B-Yah
    @Rik-B-Yah 10 หลายเดือนก่อน +1

    Lol....I'f the customer didn't have any gas you would have changed the valve for nothing....the first thing is to check the gas
    .....

  • @donf3739
    @donf3739 ปีที่แล้ว

    I just watched another video where a solder connection on the back of that black terminal block broke loose, and all it took was a little solder and flux. I would try looking into that before replacing the whole valve.
    th-cam.com/video/goarb1XJhDI/w-d-xo.html

  • @NotoriousJKB.
    @NotoriousJKB. 2 วันที่ผ่านมา

    Bro that field piece dies in 5 minutes I swear

  • @brandonharvey7939
    @brandonharvey7939 8 หลายเดือนก่อน

    The only people that watch these videos are homeowners who can't afford to pay a technician to fix their furnace for them and like a complete a$$hat you pull out a 2 thousand dollar combustion analyzer when there is no way in hell any of those viewers will have a set of those laying around.....