Hydraulic Modelling with Modelica & SimulationX

แชร์
ฝัง
  • เผยแพร่เมื่อ 16 ม.ค. 2025

ความคิดเห็น • 16

  • @mehmetalivat
    @mehmetalivat 4 ปีที่แล้ว +1

    This is very helpful thank you.

  • @ErickAlex1
    @ErickAlex1 2 ปีที่แล้ว

    amazing work sir thank you

  • @md.shahinurrahman747
    @md.shahinurrahman747 2 ปีที่แล้ว

    Thanks Mike for great presentation. I want to ask you one question, If the model is finalized after according to the requirements, is it possible to export those model data to use in the 3D CAD Environment for the CAD geometry creation of some components and the systems overall 3D visualization purpose?

  • @mithunsoman619
    @mithunsoman619 3 ปีที่แล้ว

    how can we release pressurized fluid in an accumulator to drive a hydraulic pump by using dymola models

  • @MrMohsin23
    @MrMohsin23 6 หลายเดือนก่อน

    I have encountered a problem while bringing some hydraulic elements from a different model and try to connect with existing elements in current model using connector. it doesn't connect, any solution to this problem.

  • @muhammadnoman6071
    @muhammadnoman6071 7 ปีที่แล้ว

    Dear please make some videos on steady state results

  • @ramyasree5766
    @ramyasree5766 4 ปีที่แล้ว

    Hi sir. good evening. My name is Ramu. I working in Hydraulic Rockbreaker Company in india. I want to learn Simulation X software sir. Please Help me

  • @saidlhadjdihia3171
    @saidlhadjdihia3171 7 ปีที่แล้ว

    comment je télécharge les logiciels ?

  • @navidmohammadzadeh2141
    @navidmohammadzadeh2141 5 ปีที่แล้ว

    The new version of Modelica seems to be very much different from what you were using for your tutorial. As a brief example, I am not able to change the type of the fluid passing within the pipe even though I have followed you and have double clicked on the connection. There not found anything to change the type of fluid to water.

    • @jeanli3645
      @jeanli3645 5 ปีที่แล้ว

      because you can't chage an example, you need to duplicate it, that's how you can chose an other fluid

    • @anettklo3986
      @anettklo3986 4 ปีที่แล้ว

      Hi Navid,
      maybe you have not used the same library. Mike Crowley shows a small hydraulic pipe example with the SimulationX Hydraulics library, not with the Modelica Standard Library. In the latter one the connections usually show way less information.
      model of mechanics: Modelica Standard Library (MSL)
      model of hydraulic pipe: SimulationX Hydraulics library
      model of his wave energy converter: SimulationX Hydraulics library combined with Signal Blocks from SimulationX, too.
      All those libraries (MSL from the Modelica association and the SimulationX ones) base on the Modelica language and are shown here in the program SimulationX.
      If you want more information about this feel free to download the latest SimulationX 4.1.2 setup in the SimulationX Customer Center (www.simulationx.com/customer-center.html - a registration is required).
      A license is not required as even if you are not having a licence you can test SimulationX based on a slimmed-down version called Express Edition, which allows small models in several physical domains (hydraulics, mechanics, pneumatics, controls, electronics, ...).
      If this was not answering your problem and you are already working in SimulationX feel free to tell the problem in more detail.
      Regards, Anett

  • @basmaal-ghali9174
    @basmaal-ghali9174 5 ปีที่แล้ว

    Thank u sir
    I'm using 32 bit windows 7 to run the openmodelica
    software, this error appeared as I opened the openmodelica
    [1] 10:06:27 Syntax Warning
    [C:/OpenModelica1.13.232bit/lib/omlibrary/ModelicaServices 3.2.3/package.mo:
    165:40-166:7]:
    OpenModelica only supports 31-bit signed integers! Truncating integer: 2147483647 to 1073741823
    And when I write a simple tutorial program.. this
    error appeared:
    [5]
    10:33:30 Warning
    Out of memory! Faking a stack overflow.
    [1] 10:33:38 Warning
    Out of memory! Faking a stack overflow.
    [2] 10:33:38 Scripting Error
    Stack overflow occurred while evaluating translateModel(RLC_Circuit.circuit, startTime = 0, stopTime = 1, numberOfIntervals = 500, method = "dassl", tolerance = 1e-6, outputFormat = "mat", variableFilter = ".*"):
    [bt] #1 [... unsupported platform for backtraces]
    Could anyone help me, please