Lightning Arrestor installation mistakes in solar system in Pakistan | Lightning Arrestor Earthing
ฝัง
- เผยแพร่เมื่อ 13 ต.ค. 2024
- Lightning Arrestor installation mistakes in solar system in Pakistan | Lightning Arrestor Earthing
A lightning arrestor or surge diverter is a device that is used to safeguard the solar panels and solar structure from lightning strikes.
Lightning arrestors serve as the first line of defense, protecting solar panels, inverters, and associated equipment from the destructive force of lightning strikes. But their significance extends beyond mere protection; they ensure uninterrupted energy production and system longevity.
In this video, you’ll explore:
The fundamental workings of lightning arrestors.
Why lightning poses a significant threat to solar systems.
Best practices for installing and maintaining lightning protection systems in solar arrays.
Real-world examples highlighting the importance of lightning arrestors in mitigating damage and downtime.
Installing a lightning arrestor system is a crucial step in protecting your property and electronic equipment from the devastating effects of lightning strikes. However, even the most well intentioned installations can fall short if certain common mistakes are made.
In this informative video, we uncover the top lightning arrestor installation mistakes to avoid, ensuring your system is robust and effective:
1. Improper Grounding
2. Inadequate Surge Protection
3. Incorrect Placement
4. Poor Installation Techniques
5. Neglecting Maintenance
Whether you're a homeowner, business owner, or installer, understanding and avoiding these common pitfalls can help fortify your property against the unpredictable forces of nature. Don't risk the safety of your equipment. Watch now to learn how to sidestep lightning arrestor installation mistakes and protect your investments. Remember to like, share, and subscribe for more essential tips on safeguarding your property and equipment from lightning strikes.
#LightningProtection #LightningArrestor #SurgeProtection #ElectricalSafety #TransientVoltageSuppressor #LightningRod #EarthingSystem #PowerDistribution
#LightningSafety #ElectricalEngineering #GroundingSystem #SurgeArrester #LightningDamagePrevention #VoltageSurgeProtection #StormProtection
*Contact us For Booking/Event Invitations/Sponsors your Products/Business Inquiries**
WhatsApp Only : +92 311 674 5016
email : ajelectric.wah@gmail.com
My other useful videos links :
Switching solution of load shedding in grid tied solar system | PV Switching Mechanism
• Switching solution of ...
10 KW Grid tied solar system best quality installation | Net metering | Bahria Town
• 10 KW Grid tied solar ...
5KW Solar system complete installation guide with Longi solar panels and Solarmax inverter
• 5KW Solar system compl...
3.2 KW Solar system complete installation guide | Aerox 3.2 KW inverter | system cost • 3.2 KW Solar system co...
Solar system frauds and scams in Pakistan | 5KW solar system improvement | Axpert 5.2KW
• Solar system frauds an...
5 KW Solar system complete information in Urdu/Hindi | Tesla solar inverter • 5 KW Solar system comp...
3.2 KW solar system complete calculations ¦ Solar panels ¦ Solar inverter ¦batteries requirement • 3.2 KW solar system co...
Best solar panels brands in Pakistan | Canadian solar panels review | how to buy solar panels https:/ • Best solar panels bran...
300 Watts Solar system complete installation guide | Solar system cost | Battery | Inverter • 300 Watts Solar system...
How to install Solar Panels on fitting stand | Complete installation guide • How to install Solar P...
Inverex 180 Watts Mono PERC Solar Panel review | Best Solar Panel 2020 in Pakistan • Inverex 180 Watts Mono...
For more Interesting Technical Videos Please Subscribe This Channel :)
Subscription Link: www.youtube.co....
Also here you will find a variety of videos about Engineering and Technology Including Tech reviews, unboxing, specially electric and electronic circuit’s tutorials in Urdu / Hindi.
My motive behind to create this channel to spread the knowledge about advance and easy technologies around the world.
And I want each and every individual whoever is interested in technology to be able to understand it in the easiest possible way. It’s all here on AJ Electric. #ajelectric
Make sure to subscribe my channel and press that bell icon for latest notifications so never miss any video.
Thanks for your Support and Visiting :)
Facebook : / aj-electric-1083315874...
WhatsApp : 923116745016
As per schneider electrical sop lightining arrestor should be at least 10ft away from solar structure and 10ft above the solar highest point.
Any reference?
@@Batoor_khan
• مزید ریفرنس آپ خود ڈھونڈیں -
• انھوں حوالہ تو دے دیا Schinieder کا
Thank you sir g ap ki videos se bohot faida howa hy liken me ne is se pehly bhi comment kiya tha ki ik video solar panels ki complete dp connection per banay (complete dp box) connection please sir
Pvsyst software ki videos bh bnadin completely.. ek complete solar system ki designing+ according to standards sary parameters feeding.. ye sah details mn cover ho.
JazakAllah
Hey there, just wanted to point out that the lightning arrester you installed appears to lack grounding. Without a solid earth connection, the arrester might not effectively divert lightning-induced currents away from the system. It's crucial for safety and equipment protection to ensure proper grounding is in place. Keep up the good work, but don't forget the importance of grounding for effective lightning protection! 😊🌩 Be safe!
انجینیر صاحب اگر لوگوں کو یہ بھی بتا دیتے کہ اس lighting arrester کو ارتھ بھی کرنا ھوتا ھے تو پروٹیکشن کا عمل مکمل ھو جاتا ۔
Good Question
congratulations on your 1Million subscribers, Unfortunately the first visible mistake on your channel that i ever saw. Please ground the lightning arrester using copper strips and digging a hole with salt and charcoal pit, the main reason of lightning arrester is to ground the extra charge, if arrester is not grounded the charge would jump to the nearest ground connection which can be the solar panels, l2 structure or house wiring
Yes this is the proper way to installation
Bhai lightning arrestor ke sath koi Wire conect karna parta hai ya bas siraf ye cheez lagana hai,?
Excellent sir, AoA, is lightning arrester per kitna karcha atta ha.
may Allah give you Jazah for all this as it is simple to understand
Dear, one million mubark ho.
kher mubarik brother
Local invertor ke nutral ar earth k against voltate atay hn, is ka hl batain pl.
Asalam o Aleikum sir .
Sir kindly request ha ka solar designing ka course to krwa day.
Like pv syst , helioscope, sketcup
Or aik video or bna dain jis main. Solar tubewells or or ghr ka lia solar ki full designing ki calculations hon.
Bht shukrya
ماشاءاللہ بہت خوب
Sir mashallah aap ok advance me Mubarak ho 1 million subscribers hony par❤ ma ishtiaq ichra LHR say ho ❤
Sir lithium battery pr b video bnaen is k nuqsan or faide
Assalamualaikum boss is k Sath Earthing pit hona zarori hai AP NY na wire connect ke hai na wire pit ka Jo associate point hai wo Bata ya hai Light arrestor without pit k k se protection kar Sakta hai?
Kya 3kw system k liyi lightning arrester lagana lazmi hai kya???
Aslam o Alikum Sir apka ofice konse city hy
جزاک اللّٰہ بہت خوب
Please share video regarding complete lightning arrester installation/earthing/purchasing etc for home protection.
sir microwave oven k mutalik btayen kia waqaye wo sehat k liye bohat nuqsan deh hai? ye pe tafseeli clip bnayen k kese eske nuqsan se bacha ja sakta hai
1M ki mubarik ho janab🎉
Assalam O Alakium
Aamir bhai very nice information, Please ye b bataye k aap ny bore b kia ha ? Agar kia ha to kitna ft ?
Jaza Ka ALLAH
ویوز کیلئے ویڈیو ہے، کوئی جواب نہیں ملے گا۔ بہرحال اس نے بھی یہ اریسٹر غلط ہی لگایا ہے۔ 😂
AoA does this require a separate earthing or can it be connected to the existing one?
Advance congratulations for 1million subscribers
amir bhai 3 faz conection pa net meetring on ho skti ha 550 walay 24 panals sa..?
Bhai ye lightning arrester kis material ka hona chaiye aj kal market main brass ( Tambe) k material main ah rahe hain kia brass kamyab hay ya pure copper ka hi lagana chaye
Thanks Aamir Bahi
ماشاءاللہ
اچھی کاوش
جزاک اللّٰہ ❤️❤️♥️
Assalam O alaikum. Sir yeh kam se kam kitny kw k sath lagaty hain or kitnay ka mily ga.?
30° per protection dyta hai .. Rolling Sphere Method k mutabiq ap ka lightning arrester ki height bht kam hai.
Assalam u alaikum sir aik video is pa bna da k solar system suraj ki roshni sa keasa voltage, current bnata ha
Sir 1 m ki bht bht mubarak hoo❤
Thank you sir
Dear Sir ,
Meray pas 4.5 Kilowatt MPPT Hydrid inverter hey Jis ke PV 6200 hey masla yeah a rah hey jab may 12 panels AK saat series may join kar rah hu toh error 59 and 57 a rah hey aur jab manay panels Kam kr deya aur 10 panels par agaya toh Sahi ho gaya ab Meray 2 panels waste ho ray hain mujay Kuch asa connection bata dain k Meray 2 panels b utilize ho jayan
Note : Max PV volt 500 hey inverter ka
Ya black isolater kahan say milayga or price kiya hai ya mujay online bej saktay hai
thanks for everything
جزاكَ اللّٰه
A.O.A
Lightning Arrestor to laga deya ha. Grounding keon nahi lagai gai.
Lightning, Arrestor pr Aanay k bad jay ge kdr. Plz is ke b wazahat kr dn.
Lightening arrestor ko ground nahi kia balke insulator laga kr isolate kr diya ha earthing se... Tabahii 😂
I hv 8 kva solar system with lightening arrestor.Then added 4 kva unit and both units coupled.But installer didn't put lightening arrestor for 4 kva unit and says that previosly fitted lightening arrestor is enough.
Is he right or should I ask to add separate lightening arrestor for new 4 kva unit ?
Please advise.
Congratulations🎉🎉 1million subscriber
Sir 3.5 KW tak achy inverter ki kindly details video banye 2 SE 3 compare
Good Work & Informative Video Ma Sha Allah 👍👍
Lighting arrester ki wiring bhi dekha panel ke sath kaise karte hai bhai?
nice info
Zabardast vlog
congrats for 1M in advance🎉😊
Amir Sahib mery pannels ke height 9 meter ha but arrester nai lgaya. Ap kia advise kerty hain?
lgwa len
Sir ap ney lightning arrestor men ground earth use nahi ke ?
Nichy wala system ni btaya aap ny k kitni gehri pit dig krni hy
What is price of lighting structure???
❤
Sir ham ny 6hazar kv ka system lagwaya hai or lighting aresstor ko gali ma darwany k agy ameen ma lagwyaa hai to is k koi nuksan to nai?
Arth ka tar chota par gaya hy to us mein jor laga saktay hy or jor 1mm ka laga saktah hy
بھاٸی اس لاٸیٹننگ اراسٹر کو زمین میں ارتھ ground بھی کرنا ھوتا ھے۔۔ جو اس بجلی کے چارج کو گراٶنڈ کر سکے۔۔
جسکا آپکی ویڈیو میں کہیں ذکر نہیں کیا۔۔ نہ ھی ویڈیو میں کہیں نظر آرھا ھے۔۔۔
wo to understood hy na brother ..video ka topic wo ni tha is liye zikr ni kia ..
@@AJElectric
جب ویڈیو بنارھے ھیں تو پوری بات بتاٸیں۔۔
یہ حصہ بھی بہت اھم ھے جناب۔۔
Dear Sir! What do you mean by ''ACCHI KHASI HEIGHT ''
Sir agar solar system k center me isolation kr lagatay or unhcai ziada hoti to ziada behtr tha.
Sr isk sath earth wire lga kr bor kr k andr dal dty to eating strong ho jta
wo to understood hy na lagai hy video mn ni dikha sky yad ni rha
ℕ𝕚𝕔𝕖 𝕚𝕕𝕖𝕒 aamir bahi
Excellent content but totally non responsive; tried multiple times through various mediums but no response at all.
Bhai hamin 220v ko bjaey 230v qn rakhny chaey inverter output pay jub k 220 rakhin to bayry zeyada backup deti ha
amir bahi es ko app nai cable nahi lagaya kia es ko cable k zarorat nahi hain ?
❤ وعلیکم السلام ❤
Nice
Solar panels aur lightning arrestors ke liye earthing zaruri hoti hai. Earthing se system ko bijli ke jhatkon aur overvoltage se bachaya ja sakta hai, jo safety aur performance ke liye zaruri hai. Earthing ke baghair lightning arrestors apni poori tarah se kaam nahi kar pate aur solar system ke liye bhi risk badh jata hai.
Multan ma install kertay hain solar aap ?
Very nice dear brother ❤️
JAZAKMULLAH KHAIR ❤
Cost+??
An electrical Engineer, (phD, professor and HOD of Engineering dept of a university) passed a statement which somewhat says the lighting fall probability is higher on the roof having solar panels (due to some electrical cloud formation? or other.).
I dont remember his exact wording. May be some electerical engineer can reconfirm it
yes due to charge accumulated on solar plates.
What about the Grounding of Lightning arrestor?
With copper cables or conductor ?
Regards
Nice & Informative Video
Where to get this insulator?
Mashallah
Sir meray ghar mai solar laga hoa ha or main on karty hai to reverse light on ho jati hai iska koi solution
500 watt ka panel kitny ka milta hoga
Pori video banani chate thee bhi nechaye ja aik bor karna hy ya tar road sara
Water boring can be used for earthing
آج کل مارکیٹ میں بہت قسم سولر دستیاب ہے اس میں اچھا سولر کونسی کمپنی والا ہے جیسے کنڈین سولر لونگی سولر سر جی اس پر ایک ویڈیو بناو
Longi jinko Canadian
JA bilkul na lagana
میرے بھائی n type 580w bf glass astronergy بہت اچھی پینلز ہیں
Hamary elaqy mein tu zaidah tar JA lag rahi hai...apko q na pasand hai ?@@dreamofmillions1461
Where to attach the wire with lightening arrestor?
Agar insulator barish main gelaa ho gaya to ?
must earthing wire connect to the lighting arrestor to earth
وائر کو کہاں کونیکٹ کریں گے
❤❤
Sir app whattsapp pay to bat nahi sunnty hai
نہ مکمل وڈیو
❤❤❤❤❤❤❤❤❤❤
Mera ap nay insulator nain lagaya tha na idher lagaya hay😢
Ap ne inn se kis city mein system install krwaya tha??
@@engrrashidkarim7932 wah cantt
@@engrrashidkarim7932 multi orchard
Engineer Muhammad Ali Mirza saab ka Interview kre plzzz
Nikal, jahil k student 😂.
Amir banda ap sy contact kassy karyy
Wattapp py reply n dety AP bhai
bhai plz call b utha liya krain
یہ طریقہ اور بھی خطرناک ہے ۔ lightening arrester کو گراونڈڈ ہونا چاہیے۔ اس طریقے میں آپ نے lightening کو arrest تو کر لیا لیکن اب یہ جائے گی کہاں ۔ لازما آس پاس کی چیزوں یعنی panels وغیرہ پر۔ اس پر وہ مثال صادق آتی ہے کہ "آبیل مجھے مار"
hum ne to na arrestor lgwaya hai or na earthing...kia lightning roof k andar se guzr k asakti hai???😅
mujhy solar panel ki tension nahi hai apni tension hai..kahin meray sar py na akar gir jaye..
@@Zahra-tp5lv ایسا کہی لاکھوں میں ایک ہوتا ہے ۔ بجلی اصل میں نہ صرف پورے سولر سسٹم کو تباہ کر سکتی ہے بلکہ سولر کی وائر کے ذریعے نیچے آکر ساری الیکٹرانک اشیاء کو اور ان سے کوئی انسان بھی ٹچ ہو سب کو نقصان پہنچا سکتی ہے لیکن جیسا میں نے پہلے کہا ایسا لاکھوں میں ایک ہوتا ہے ۔ ہم نے بھی ارتھنگ نہیں کی ہوئی ہے
Is ka Naam kia hai
جس راڈ کے ساتھ سے لگایا ہے اس میں بجلی پڑے گی تو سارا گھر اڑ جائے گا۔
انسولیٹر کو ایسی لوکیشن پر لگانا چاہیئے کہ تار کا اس راڈ سے کوئی واسطہ نہ رہے۔
سر کیا لاٹینگ اریسٹر کو ارتھنگ کی ضرورت نہیں ہوتی کیا؟ میں نے تو کمپنیوں میں دیکھا ہے۔کہ اسکے ساتھ ارتھنگ ہوتا ہے۔اور مکہ کلاک ٹاور میں بھی جو چاند ہے وہ بھی لاٹنیگ اریسٹر ہے۔
❤❤❤
ma ny b ak do jaga deki
o bhai wire konsi lga he …. sastay engineer
آ پ کا فون نمبر کیا ھے سرکار اعلیٰ
Ap apna whatsapp # dy dein. Mjy 10KW Ongrid system install karwana hae apsy.
Google information