PV Switching system for On grid solar system to prevent load shedding | Net metering

แชร์
ฝัง
  • เผยแพร่เมื่อ 22 ส.ค. 2024
  • PV Switching system for On grid solar system to prevent load shedding | Net metering
    There are three main types of solar system On grid Off Grid Hybrid solar system all types of have their own advantages and disadvantages depends on condition. Load shedding in Pakistan is a big problem specially in summer season due to electricity short fall.
    So this video is about 15kw grid tied system in which LONGI 545W panels are installed and Sofar 15KW on grid solar inverter is installed with net metering system.
    But we know that during load shedding on grid solar system is going on off position and during those hours solar panels are useless. I make a switching mechanism with some magnetic contactors ac relays and a Max power infini V2 hybrid solar inverter.
    So this grid tied solar system with battery backup or on grid solar system with battery backup OSAKA TA 1800 tall tubular batteries are installed and this is a three phase solar system with two solar inverters one is 15kw hybrid solar inverter and another is 10KW hybrid solar inverter which is working here as a off grid inverter or ups.
    #loadshedding #ongrid #netmetering #solarsystem #saynotoloadshedding
    *Contact us For Booking/Event Invitations/Sponsors your Products/Business Inquiries**
    WhatsApp Only : +92 311 674 5016
    email : ajelectric.wah@gmail.com
    My other useful videos links :
    10 KW Grid tied solar system best quality installation | Net metering | Bahria Town
    • 10 KW Grid tied solar ...
    5KW Solar system complete installation guide with Longi solar panels and Solarmax inverter
    • 5KW Solar system compl...
    3KW Solar system installation guide with One X VM3 Solar Inverter | system cost
    • 3KW Solar system insta...
    3.2 KW Solar system complete installation guide | Aerox 3.2 KW inverter | system cost • 3.2 KW Solar system co...
    Solar system frauds and scams in Pakistan | 5KW solar system improvement | Axpert 5.2KW
    • Solar system frauds an...
    5 KW Solar system complete information in Urdu/Hindi | Tesla solar inverter • 5 KW Solar system comp...
    Solar Tube well system with 3hp water pump 1.5 inch water delivery | invt vfd inverter • Solar Tube well system...
    Solar system fault detection and step by step troubleshooting method | Solar system faults
    • Solar system fault det...
    Solar inverter complete setting in urdu | Inverex | Tesla | One X | Max Power
    • Solar inverter complet...
    3.2 KW solar system complete calculations ¦ Solar panels ¦ Solar inverter ¦batteries requirement • 3.2 KW solar system co...
    Best solar panels brands in Pakistan | Canadian solar panels review | how to buy solar panels https:/ • Best solar panels bran...
    300 Watts Solar system complete installation guide | Solar system cost | Battery | Inverter • 300 Watts Solar system...
    How to install Solar Panels on fitting stand | Complete installation guide • How to install Solar P...
    Inverex 180 Watts Mono PERC Solar Panel review | Best Solar Panel 2020 in Pakistan • Inverex 180 Watts Mono...
    For more Interesting Technical Videos Please Subscribe This Channel :)
    Subscription Link: www.youtube.co....
    Also here you will find a variety of videos about Engineering and Technology Including Tech reviews, unboxing, specially electric and electronic circuit’s tutorials in Urdu / Hindi.
    My motive behind to create this channel to spread the knowledge about advance and easy technologies around the world.
    And I want each and every individual whoever is interested in technology to be able to understand it in the easiest possible way. It’s all here on AJ Electric. #ajelectric
    Make sure to subscribe my channel and press that bell icon for latest notifications so never miss any video.
    Thanks for your Support and Visiting :)
    Facebook : / aj-electric-1083315874...
    WhatsApp : 923116745016

ความคิดเห็น • 328

  • @EngineerMuhammadAliMirzaClips
    @EngineerMuhammadAliMirzaClips ปีที่แล้ว +10

    Excellent Analysis ! ! ! May ALLAH Protect Our Nation & Our Country PAKISTAN from all Internal & External Enemies. Aameen ! ! ! May ALLAH guide all of us towards his path of TRUTH. Aameen ! ! ! TRUTH Lovers ko SALAM ! ! !

  • @Tabrezwords
    @Tabrezwords 2 ปีที่แล้ว +4

    Huge respect sir... Sir aap ne hme parhaya hai electrical workshop first semester mn wah engineering college mn kyaa kamal k teacher the aap jo jo b parhaya tha ap ne examples de ke wo chezain abi b yaad hain Allah pak ak ilm mn r izafa kare

    • @jahangirali8693
      @jahangirali8693 หลายเดือนก่อน

      Bhai kaha parhaty hain air?

  • @mahmoodmirza3301
    @mahmoodmirza3301 2 ปีที่แล้ว +1

    بہت شکریہ محترم ایک معلوماتی اور پریکٹیکل ولاگ کیلئے۔

  • @AbdulHafeezs
    @AbdulHafeezs ปีที่แล้ว +3

    I have already designed and installed this system in Islamabad. System is running smoothly and no issues are observed. Client is also satisfied.

    • @shn313
      @shn313 ปีที่แล้ว

      total cost ?

    • @chaneesali9488
      @chaneesali9488 ปีที่แล้ว

      Cost?

    • @shaazy
      @shaazy หลายเดือนก่อน

      Who can do this in Khi

  • @8uhayat
    @8uhayat ปีที่แล้ว +3

    AC/DC retrofit and coupling has been done for years. Nothing new here except to make a 3 mins vid into almost 13. Glad you woke up, welcome to the world of "retro-fitting"

    • @thesaadiqbal52
      @thesaadiqbal52 หลายเดือนก่อน

      Some say that Its for AC current. DC current will burn this system. Is it safe

    • @8uhayat
      @8uhayat หลายเดือนก่อน

      @thesaadiqbal52 Depends on who does it and how. When the grid is down any on-grid inv will stop producing AC current because of compulsary safety regulations to keep linemen safe, No on-grid inv will power your home in an outage since their output is also balanced across 3 phases regardless of what your load is phase wise hence they switch off. Its very easy to retrofit a goodwe hybrid with a goodwe on-grid and so on, meaning same companys specifically designed retrofit hybrid invs. But, the cost of that is too high and no lower brand that I know of makes specific retrofit hybrid invs. The following solution works regardless of make/model.
      1. Add a hybrid inv and split its output to all 3 load phases or 1 phase if your house is wired that way, ofcourse that output would require an ATS (auto switching) so it only outputs once the grid is down and not when its up.
      2. The existing PV arrays can be used, just hook them to another ATS which will primarily provide power to the on-grid and shift the PV DC power to the hybrid only when the grid is down.
      3. DV (PV) and AC output switching can also be done using simple change overs but the specs of the change over must match, especially for DC. ATS just makes it safer and automatic.
      Unfortunately here 99 percent installers are totally incompetent but this solution is a hundred percent safe and applied at millions of homes across the globe incl mine.

    • @habibali6091
      @habibali6091 หลายเดือนก่อน +1

      @@8uhayat Lovely reply. Thanks for such a detailed response. Such comments are no less then a treasure for knowledge seekers.

  • @hmdazm
    @hmdazm ปีที่แล้ว +25

    Well, I can understand that with an existing On-grid system you used an off-grid inverter to use the solar power during load shedding. While this can also be handled by using a hybrid inverter that automatically switches to off-grid mode while load-shedding.

    • @zahooruddin8378
      @zahooruddin8378 ปีที่แล้ว

      اتنی سی بات تھی جسے اس لالچی یو ٹیوبر نے لمبا کردیا۔

    • @daythunder1
      @daythunder1 ปีที่แล้ว

      @@zahooruddin8378 lalachi youtuber 😂... He showed you another way of utilizing solar energy during load shedding rather then switching to hybrid you can simply add off grid inverter to your system.

    • @umairmba8
      @umairmba8 ปีที่แล้ว +2

      Its because Wapda & Specially Fesco allows net metering only on On grid & not on Hybrid systems.

    • @rahi480
      @rahi480 5 หลายเดือนก่อน

      With one hybrid and one on grid inverter, can we simultaneously feed to grid?

    • @goodghost6182
      @goodghost6182 4 หลายเดือนก่อน

      ​@@umairmba8 why

  • @saadsiddiqui16
    @saadsiddiqui16 ปีที่แล้ว +20

    That is called Jugar which was not needed. In your video you said to have used Hybrid Inverter, and Hybrid Inverter is capable of working on-grid and off-grid as well. So basically you have not understood the capability of a Hybrid Inverter and have wasted a lot of time and money.

    • @imranilyas7782
      @imranilyas7782 9 หลายเดือนก่อน +1

      Bahijan wapda walay hybrid inverter accept nai kertay shuru mai

    • @engrattari
      @engrattari 7 หลายเดือนก่อน +1

      What a Gem. 😂
      Aesay ee genius bharay paray hain Pak mn

    • @rahi480
      @rahi480 5 หลายเดือนก่อน +1

      Can we feed to grid from both inverters simultaneously?

    • @goodghost6182
      @goodghost6182 4 หลายเดือนก่อน

      ​@@imranilyas7782why?

    • @sahirelectronicssolarsecur9466
      @sahirelectronicssolarsecur9466 หลายเดือนก่อน

      Bhai ap ko shayed hybrid aur ongrid ki efficiency aur life span ka idea nhe is leay apka asa kehna bnta ha

  • @danispervez4793
    @danispervez4793 2 ปีที่แล้ว +11

    Kindly make another short video for explaining this relay and magnetic contactor wiring diagram how 2 different string work on this its humble request for you sir

  • @razabrotherindustries3214
    @razabrotherindustries3214 ปีที่แล้ว +1

    ماشاءاللہ اللہ تعالیٰ آپ کو مزید ترقی و کامیابی عطا فرمائے

  • @muhammadashraf-og8ef
    @muhammadashraf-og8ef 2 ปีที่แล้ว

    السلام علیکم
    عامر بھائی۔ آپ کی آپ کی وڈیوز بہت معلوماتی ہوتی ہیں اور بہت فائدہ مند بھی ۔
    لیکن عام بندہ کی پہنچ سے بہت دور ہیں۔لاکھوں روپے کے سسٹم اور بڑے بڑے پروجیکٹ۔ ضرورت اس امر کی ہے کہ سولر سسٹم کا فائدہ بارہ پندرہ ہزار ماہانہ بل ادا کرنے والا بھی اٹھا سکے۔ اس کے لئے کوئی ایسی اسکیم درکار ہے جس میں عام لوگوں کو انسٹالمنٹ پر ایسے سسٹم لگا کر دیئے جائیں جو بل کی رقم سولر قسط کے طور پر ادا کریں۔ اس سلسلے میں کوئی ایسی کمپنی جو اپنا جائز منافع لے کر یہ سہولت مہیا کر سکے اس پر کام کی ضرورت ہے۔

  • @sohaibahmed3505
    @sohaibahmed3505 ปีที่แล้ว +5

    You're using normal magnetic contactor for switching high voltage DC from solar panels, that's a risky deal , DC arc can burn contactor points or God forbid even more than that , should use some DC breakers here somehow

  • @ashrafunnisakhan3334
    @ashrafunnisakhan3334 ปีที่แล้ว +4

    High Voltage DC PV Switching Systems with AC Contractors
    This Will Damage Your System.

  • @abbumuawia4896
    @abbumuawia4896 2 ปีที่แล้ว

    AAP ne apny ingeeniar honey ka haq ada kardiya...Masha ALLAH...ALi electric work....

  • @lostalien93
    @lostalien93 2 ปีที่แล้ว +7

    Sorry to say this 10kw hybrid inverter is very hectic when comes to warranty and comparatively expensive. Since there was no industrial load, you could've easily given single phase hybrid or off grid inverters which are convenient for warranty. Secondly, spending additional 8-9lacs for running off grid is not feasible until unless thr client already didn't own a generator. It's one way out but not feasible. Lastly, there is no sufficient cleaning space for the solar panels. Overall installation is good but there's always room for improvement.

    • @AJElectric
      @AJElectric  2 ปีที่แล้ว +2

      building ke wiring three phase the or proper distribution bhe ni the load ke ,,so many reasons

    • @xXAbdulBaqiXx
      @xXAbdulBaqiXx 2 ปีที่แล้ว +1

      @@AJElectric why not join three 5kw systems to make 3 phase?

    • @mrasheed5815
      @mrasheed5815 ปีที่แล้ว

      @@AJElectric السلام علیکم
      میں سولر کا کام سیکھنا چاہتا ہوں محترم کیا آپ مدد کر سکتے ہیں ۔
      میں نے الیکٹریکل ڈپلومہ ہولڈر ہوں

    • @ZubairAhmad-we7wm
      @ZubairAhmad-we7wm 10 หลายเดือนก่อน +1

      ​@@AJElectric mere pas 1 ongrid 10 kw inverter he 1 off grid 5kw he panels 3 kw k hen sirf
      Installer keh Raha he k off grid k wapda se ups k tor pe use kren aur battery 48 he 175*4 Lekin wo b dead hen
      Ab issue ye he k kia hum 1
      3 kw hybrid inverter Len wo without battery day time load chalae ga
      Ya koi aesa system hojae hum APNA off gird inverter se day time light load chale saken? Raat k liye generator he use k liye

  • @saqibsarwar2155
    @saqibsarwar2155 2 ปีที่แล้ว

    ماشاللہ سر great job

  • @EAR.Pakistan
    @EAR.Pakistan 3 หลายเดือนก่อน

    Just installed a hybrid inverter but in video, he tries to show his special competency.

  • @madiljaved
    @madiljaved 3 หลายเดือนก่อน +2

    Shadid chawal mari bhai ne

  • @waqarahmed-sz3fj
    @waqarahmed-sz3fj 6 หลายเดือนก่อน +1

    Jo log is Kam Ko sarha rayah heen oun ko bata doon kay Solar Inverter ko kabbhe bhe On condition may Solar PV say connect or disconnect nahe kartay ye ek khatar nak amal hay is may inverter damage honay ka khtara hota hay or on load contactor make break may high voltage sparks hota hay.
    bhai aye say barsati installer say bachoo.
    Solar lagana koi bari bath nahe but jab bhe lagaoo kisi paray likha Engineer say lagaoo jo ye kam janta hoo.
    Is kam ki demand bohat hay or aj kal har koi Solar installer champions bana pher raha hay.

  • @tahirtayyab007
    @tahirtayyab007 2 ปีที่แล้ว +6

    if we installed only a hybrid inverter, it may be only sufficient for the load shedding situations, and we also may not use on grid inverter. If I am wrong please answer.

    • @mohsinaslam6837
      @mohsinaslam6837 2 ปีที่แล้ว

      That's right

    • @mohsinaslam6837
      @mohsinaslam6837 2 ปีที่แล้ว +1

      What we do in such situations for 20kw load say 10kw on grid and 10kw hybrid

    • @adilnadeem3747
      @adilnadeem3747 2 ปีที่แล้ว

      In chutyio n Clint k 10 lakh ka nuksan Kiya h

    • @atiqueahmad3066
      @atiqueahmad3066 ปีที่แล้ว +4

      بھاٸ بیوقوف بنایا ہے۔ hybrid سسٹم کے بعد پہلے inverter کی ضرورت نہیں تھی

    • @sharjeelahmed650
      @sharjeelahmed650 11 หลายเดือนก่อน

      Itna complex sysytem lagaya ku hay
      Jab simple hybrid say he kam chal sakta tha
      Humaray suppliers ka masla yeh hay k woh guide he nahe kartay, buyer half information lay k aata hay aur yeh bhi nanahay ban k un ko guide kiyay bina demand fulfill kardaytay hayn ku k in ko pata hota hay k next time dobara aayngay wapis

  • @adeshchaudhery
    @adeshchaudhery 2 ปีที่แล้ว +5

    Why not to use hybrid 15kw inverter instead of one extra inverter

    • @hashimsonija
      @hashimsonija 2 ปีที่แล้ว +1

      It's also my point of view.

    • @malik.750
      @malik.750 2 ปีที่แล้ว

      Inho n replacement nhi ki usi k sth hi hybrid use krlia bs ongrid sale krlty to khrcha kam hojata. Or hybrid b 15kw mil jana tha

    • @muzamilyaseen9638
      @muzamilyaseen9638 2 ปีที่แล้ว

      i have same Q,

    • @AJElectric
      @AJElectric  2 ปีที่แล้ว +2

      q k ongrid pehly laga or hybrid us k kafi din bad..pehly decide hota to yehe krty

  • @shahidkaleem1766
    @shahidkaleem1766 ปีที่แล้ว

    Kammal idea sir ...!

  • @araingroup1166
    @araingroup1166 7 หลายเดือนก่อน

    How green meter works? How it reverse electricity to wapda. Make a video on this topic also. U are providing good informations. Jazak Allah .

  • @SurprisedPizzaSlice-pe3jm
    @SurprisedPizzaSlice-pe3jm 11 ชั่วโมงที่ผ่านมา

    Bhai ye btana k jub subho ongrid on ho os time jo uses ha wo direct ho ghi ya phly meter man ja krr phir unit k hisab sy wapis aye ghe

  • @AbdulRauf-pk5ks
    @AbdulRauf-pk5ks 2 ปีที่แล้ว +3

    Thanks for sharing... It was informative.

  • @habibali6091
    @habibali6091 ปีที่แล้ว +1

    Thanks AJ Electric for such an informative video. I am a solar user and facing similer issue. Your video is very informative in this regard. However, I have one question. Can't we use simple 1 relay with higher current rating ? Why do we need magnatic contanter ? As relay is 2 way switch so we can simply power relay with mains and use relay 'off' position to connect PV to off-grid. Please reply to my query, waiting for your guidance. Thanks.

  • @waqarshah2200
    @waqarshah2200 4 หลายเดือนก่อน +1

    Bhai jan agar pehle se hybrid system lagadete to atni fankari our dabal khrcha na karna parta

  • @myspace6862
    @myspace6862 10 หลายเดือนก่อน

    very good idea sir
    kindly guide fow to use this type of system with genrator
    and in case of load sheading will the conversion from on-grid to off-grid inverter and vise-versa will be smooth or jerky like in case of PC will it remain ON or Not?

  • @M_R.Asad.
    @M_R.Asad. 2 ปีที่แล้ว

    دماغ کی دہی کرنے کی کوشش کی ہے اس بندے نے، پہلے ہی 10 یا 15 کلوواٹ کا ہائی برڈ انورٹر لگا کر سیم کام لیا جا سکتا تھا، کسٹمر سے زیادہ کمانے کے چکر میں ایسا کیا، جب مارکیٹ میں ہائی برڈ انورٹر موجود ہیں تو آف گرڈ سسٹم یا آن گرڈ سسٹم لگانے کی کوئی تک نہیں بنتی...

  • @Arab76103
    @Arab76103 5 หลายเดือนก่อน +1

    اَلسَلامُ عَلَيْكُم وَرَحْمَةُ اَللهِ وَرَحْمَةُ اَللهِ وَبَرَكاتُهُ

  • @fakharuzzaman2489
    @fakharuzzaman2489 2 ปีที่แล้ว +1

    ہمارے گھر ایک فریج ایک واشنگ مشین چھ پنکھے اور پندرہ بیس انرجی سیور، دس سے پندرہ واٹ کے استعمال ہو رہے ہیں۔
    اور استری بھی۔۔۔
    اتنے لوڈ کے لئے کتنے کلو واٹ کا سسٹم چاہئے؟جو دن رات کام کرے۔
    اور کتنا خرچہ ہو گا؟

  • @user-sz1fl3qb4j
    @user-sz1fl3qb4j 9 หลายเดือนก่อน

    Nice job Bhai jan 👍👍👍👍👍

  • @nomanahmad8918
    @nomanahmad8918 2 หลายเดือนก่อน

    Dear Aamir bhai Salam. Please mention 2nd inverter (maxpower) is single phase or three phase ?

  • @uzanji9986
    @uzanji9986 2 วันที่ผ่านมา

    Bhai baat to the point Karen Jo aapane heading diye Hain ki main is bare mein baat karunga to use bare mein baat karenge to patni aap kya kahaniyan suna rahe hain

  • @abdulmannanalvi
    @abdulmannanalvi หลายเดือนก่อน

    What a most beautiful way 🎉 of presentation..❤❤❤❤❤

  • @technicalinformation8347
    @technicalinformation8347 6 หลายเดือนก่อน

    Good idea but cost increases

  • @mahokhan9122
    @mahokhan9122 ปีที่แล้ว

    HI.... PAKISTANIS's People's Love you ❤️
    AL MAREEKH'SCI'S UNO UNICEF Sci

  • @naveedjaffar8965
    @naveedjaffar8965 ปีที่แล้ว

    Very Good work

  • @eqabelectrician8980
    @eqabelectrician8980 ปีที่แล้ว +1

    On grid invertr k sath battery nahi lag sakhta ??

  • @atifhussain9269
    @atifhussain9269 ปีที่แล้ว

    Zabardast great think

  • @kaptaankhantechnolgies5795
    @kaptaankhantechnolgies5795 2 ปีที่แล้ว +1

    سر کیا ہم صرف آن گرڈ انورٹر کو آن رکھنے کے لئیے یو پی ایس استعمال نہیں کر سکتے؟ بیٹری بیک اپ کے ذریعے؟

  • @MuhammadImran-up6ul
    @MuhammadImran-up6ul ปีที่แล้ว

    very informative video

  • @humannormal1553
    @humannormal1553 ปีที่แล้ว +2

    We r doing same since 1 year only difference switching is manual (as a precaution of auto switch issue)

    • @ahmedallavi6429
      @ahmedallavi6429 ปีที่แล้ว +1

      That is what I feel as well. The switching should be manual. All circuit breakers related to On-Grid inverter input and output be put to off and then this system be made to work. A little botheration but safety... But have you put these batteries as well for load shedding hours when sun is set?

  • @alhafiztv452
    @alhafiztv452 2 ปีที่แล้ว

    Good work Dear Sir!

  • @realtrue20
    @realtrue20 2 ปีที่แล้ว

    That can possible with easy way
    Your guide Make difficult for people's !

  • @razaelectricaltips
    @razaelectricaltips 2 ปีที่แล้ว

    Asslasm alkaum bhai thank you for your sharing info chnl bro sty contd

  • @educatorsacademy1028
    @educatorsacademy1028 ปีที่แล้ว

    Sir iam very thankful to u
    Sir iam studay electrical engineering in 5th semester but i dont understand that what i learnt today which is help me in future jop point of view

  • @hussainzada
    @hussainzada ปีที่แล้ว

    زبردست

  • @TaimoorTahir
    @TaimoorTahir 9 หลายเดือนก่อน

    The lightning arrestor should be on the opposite side. Arrestor's shadow is being cast on the panels, which will effect the production.

  • @ssmax81
    @ssmax81 6 หลายเดือนก่อน

    Real video starts after 9 mins.

  • @MuhammadAhmad-sg1de
    @MuhammadAhmad-sg1de 6 หลายเดือนก่อน

    Ye kam hybrid invertor c b ho sakta he but wo costly he ye both inverter b hybrid c sastay hen
    2nd agr koi already offgrid invertor use kr raha he r net metring per move hona chahta he us k liye b best he

  • @anwarali9731
    @anwarali9731 11 หลายเดือนก่อน

    اسلام علیکم ، سر جی ایک گذارش ON GRID کے ساتھHYBDRIDE انورٹر لگانا ھے ، یا صرف OFF GRID انورٹر ، دوسری بات اگر آپ RELAY اور Magnetic contector کی سرکٹ ڈرائینگ بنا کہ بہیج دیں تو عنایت ھو گی ، NO اور NC ڈرائنگ۔ میرے پاس 3 phase ھیں

  • @sajjadhussainazadar7966
    @sajjadhussainazadar7966 2 ปีที่แล้ว

    سر ہمارے گھر میں دو فریج دو واشنگ مشین دو استری دو جوسر مشین پندرہ انرجی سیور بلب چھ پنکھے ایک ایلئڈی ٹی وی اور ایک پانی کا موٹر
    اتنے لوٹ کے لیے کتنا کلو واٹ کا سسٹم چاہئے جو چوبیس گھنٹے چلے
    اور ٹوٹل کتنا خرچہ آئے گا

  • @hellodear00
    @hellodear00 29 วันที่ผ่านมา

    AoA
    sir mujy ye btay ke home wiring ma konsa contactor use hota hai jese ke (AC-1) (AC-2) (AC-3) plz sir reply me

  • @harisijaz8383
    @harisijaz8383 ปีที่แล้ว

    Good. I have installed same but cant figure out how to do inverter settings. Please make a vid on that asap.

  • @shaazy
    @shaazy หลายเดือนก่อน

    How is this system working 1 year on? Is it reliable?

  • @churahi92
    @churahi92 ปีที่แล้ว

    بہت معلوماتی ویڈیو ہے.
    سو فار کا 5 کلو واٹ کا آن گریڈ سولر سسٹم لگا ہے. مجھے اسی طرح کا سیٹ 5 کلو واٹ کے لئے درکار ہے. جو واپڈا جانے کی صورت میں سولر سے ڈائرکٹ بجلی دیتا رہے. راہنمائی فرما دیں شکریہ

  • @Azhar4612
    @Azhar4612 ปีที่แล้ว

    Good keep it up

  • @Lilaycs
    @Lilaycs 4 หลายเดือนก่อน

    Yh switch kitni bar khrab hta hai aik sal me aur es ki price kya hai ? Es sy acha yh nhi alag Invertor pr solar plates Hy lga lyn. ?

  • @AbdulMajeed-hx4jv
    @AbdulMajeed-hx4jv 2 ปีที่แล้ว

    Great job

  • @tigerkg3918
    @tigerkg3918 2 ปีที่แล้ว +3

    Kindly make another short video for explaining this relay and magnectic contactor wiring diagram. Thanks

    • @tabassumsultan.n
      @tabassumsultan.n 2 ปีที่แล้ว

      Dear Sir.
      We are also waited for same video.

  • @hamzamaalikch3384
    @hamzamaalikch3384 2 ปีที่แล้ว

    Masha Allah g bot khob

  • @shahidiqbal3707
    @shahidiqbal3707 5 หลายเดือนก่อน

    Video starts from 8.23

  • @waqarwaqar9807
    @waqarwaqar9807 10 หลายเดือนก่อน

    On-grid solar system mn jo apka do he us main apny kia kia lgaiya hoa ge???
    Mjhy apny 8 kwa system k sath hybrid invertor lagwana he 3 kwt ...kitny main lga dy gy ap????

  • @UmarFarooq-wv7xn
    @UmarFarooq-wv7xn ปีที่แล้ว

    Very good

  • @irfanfsdqba
    @irfanfsdqba 4 หลายเดือนก่อน

    Please make a video for inverter parallel operations! I need to install 2 nos hybrid invertor in parallel!

  • @rmamazia
    @rmamazia ปีที่แล้ว

    Interesting information. Please share details to have off grid system

  • @gigaspy5178
    @gigaspy5178 2 หลายเดือนก่อน

    I DON'T understand why you are using On-Grid inverter at all, grid feeding can be done through Hybrid Inverter only

  • @amhasan9911
    @amhasan9911 2 ปีที่แล้ว +3

    How do you disconnect Disco input... Because as I understand that on grid Inverter is shutdown during load shedding because of safety.... Electricity produced by Solar setup should not travel back on Disco.... Because shutdown could be because of load shedding or due to some fault and Disco staff could be working on the lines?
    So my question how Disco lines are isolated?

    • @xXAbdulBaqiXx
      @xXAbdulBaqiXx 2 ปีที่แล้ว +1

      ongrid shut down itself

    • @zahooruddin8378
      @zahooruddin8378 ปีที่แล้ว

      ساری دنیا میں ایسا ہی ہوتا ہے جیسے آپ نے بتایا ۔ اگر اس احمق کی باتوں پر یقین کر کے کسی نے ایسا کر لیا اور گرڈ کی مرمت کے دوران کوئی مر گیا تو یہ شخص اس کے قتل کا زمہ دار ہوگا۔

    • @ahmedallavi6429
      @ahmedallavi6429 ปีที่แล้ว +1

      I think during load shedding, the voltage produced by solar panels is diverted to this new off grid inverter through that newly installed relay in system. So the electricity is not travelling to our On-Grid Inverter and then to green meter and subsequently to wapda. But still its a sensitive system as per safety point of view.

    • @zahooruddin8378
      @zahooruddin8378 ปีที่แล้ว +1

      @@ahmedallavi6429 TBH , I will not take that risk or adventure ever , because it may take someone life. I will prefer hybrid inverter which is having option to connect batteries and in case of grid shut down,the batteries supply the power during power outage.
      But I will never ever try an adventure .

    • @bilalirshad7974
      @bilalirshad7974 ปีที่แล้ว +1

      I think this set up will not be approved by disco as it may result to some accident.

  • @basicinfo6816
    @basicinfo6816 7 หลายเดือนก่อน

    This is hybrid or on gird without batteries?
    Which inverter is better without batteries? On-Grid or Hybrid?

  • @Asadkhan-kn7er
    @Asadkhan-kn7er 2 ปีที่แล้ว +1

    Sir I think hybrid inverter setup is better than ongrid setup because if I spend lot of money on this setup or when wapda is not available my all setup is useless.

    • @eqabelectrician8980
      @eqabelectrician8980 ปีที่แล้ว

      To kia is mai. On grid of grid ? Invertr nahi milta kia

    • @Asadkhan-kn7er
      @Asadkhan-kn7er ปีที่แล้ว

      @@eqabelectrician8980 bro inverter to sab Milty hy magar free nahi Milty. Or jab itna pesa Laga kar ongrid system lagaheen or phir or pesy Laga ka hybrid system lagaheen to Kya fyda.

    • @eqabelectrician8980
      @eqabelectrician8980 ปีที่แล้ว

      @@Asadkhan-kn7er nahi yaha pai hum nai. 5 kw solic lagya hai. On grid b hai of of grif b hai. Dono k kam karta hai.

  • @muhammadzakriya9560
    @muhammadzakriya9560 9 หลายเดือนก่อน

    Sar Ek Sawal yah hai ki so far ke sath agar aap ek CT Transformer Laga dete to yah Baki system Lagane ki kya zarurat thi

  • @sajjadsolartubewellofficia5593
    @sajjadsolartubewellofficia5593 3 หลายเดือนก่อน

    Ustad ji lighting raster lagane ka tarika sikhane

  • @abdulkhaliq938
    @abdulkhaliq938 11 หลายเดือนก่อน

    excellent

  • @muhammadkamal2047
    @muhammadkamal2047 2 ปีที่แล้ว

    Zabardast solution... Good work bro

  • @birds9814
    @birds9814 2 ปีที่แล้ว

    gooood sir🥰🥰🥰🥰👍👍👍

  • @irfanshafiq1353
    @irfanshafiq1353 ปีที่แล้ว

    Nice n cool

  • @waqarwaqar9807
    @waqarwaqar9807 10 หลายเดือนก่อน

    On-grid solar system mn jo apka do he us main apny kia kia lgaiya hoa ge???

  • @asadullahpk
    @asadullahpk ปีที่แล้ว +1

    Lightening arrester's height is lower than panel.

  • @asifhussain6164
    @asifhussain6164 ปีที่แล้ว

    Thanks for sharing and vary good 👍

  • @abdullahyar1500
    @abdullahyar1500 ปีที่แล้ว

    We have another fromula here for this problem in on grid we are using solar on grid of10 kilo watt in night there would be no electricity from solar so we will use electricity from wapda . If electricity is not working even from wapda due to load shedding we have generator available so that would be used .

  • @khanzaddi2370
    @khanzaddi2370 ปีที่แล้ว

    Agar aik normal ghar ban raha ho new or wo log wapda ki bejli na lagna chahy solar system lagna chahy tu kon sa lagye??

  • @thkt5838
    @thkt5838 ปีที่แล้ว +1

    Okara city me lgwana hai pv system

  • @waqasakram2857
    @waqasakram2857 4 หลายเดือนก่อน

    Off grid solar system ka bara guide karayn battry,wapda ka beghair chahta to ha laken current fluctuating ki wajah sa khatra rahta ha appliances na lharab karda
    Kyoun ka solar kabhi zeyada hoti ha kabhi kam
    Mashwara dayn is masla ka koi genuine hal ha?

  • @hrhashmi61
    @hrhashmi61 7 หลายเดือนก่อน

    This seems wastage of money by using two types of inverters. Instead, you may have a hybrid system of 12-15 watts. This does seem a wise decision

  • @bilalawan277
    @bilalawan277 2 ปีที่แล้ว

    bhai idea is everything, thank you for sharing information. my self is now a solar engineer :D

  • @MegaAjaydas
    @MegaAjaydas 11 หลายเดือนก่อน

    When you are making video for teaching some one then try to give more clear knowledge and details design

  • @AmeerHuzaifah
    @AmeerHuzaifah 4 หลายเดือนก่อน

    PLEASE TELL ME COST OF GAVINYLEZED L3 TYPE SOLER STANDS 02 NOS THANKS.

  • @abdulmuqeet8233
    @abdulmuqeet8233 2 ปีที่แล้ว

    Thanks bahi

  • @tecnishion
    @tecnishion 5 หลายเดือนก่อน

    Sir aap Sirf aik hybrid inverter hi lagha ly😊

  • @sarzameen4051
    @sarzameen4051 ปีที่แล้ว

    Sir hamara 3kw nitrox ka inverter hai without netmetering. Zero export Ka option hai isme. Installer ne ct nahi lagai. Kia lagani chahye?

  • @SubEngineerOnline
    @SubEngineerOnline 4 หลายเดือนก่อน

    مارچ میں لاہور میں 12 بجے 30 درجے پر سورج ہو یعنی سردیوں میں تو اور زیادہ چاہیے ہوت
    یعنی کم از کم 30 درجےپر فکس کرنا چاہیے ناکہ 15 درجے پر

  • @muhammadaqibsarfraz2369
    @muhammadaqibsarfraz2369 ปีที่แล้ว

    On Grid + UPS is the most economical Solution.
    This System is very expensive

    • @noumanyounas2426
      @noumanyounas2426 11 หลายเดือนก่อน

      Ups allowed with on grid system?

    • @muhammadaqibsarfraz2369
      @muhammadaqibsarfraz2369 11 หลายเดือนก่อน

      @noumanyounas2426 it's works separately. Separate wiring of UPS is need to be done. On Grid Inverter stops working during load shedding.
      At that time UPS provides backup for Lights and Fans etc

  • @user-ki5it7gr1u
    @user-ki5it7gr1u 2 หลายเดือนก่อน

    SolarMax inverter kaisaa hai ?

  • @ABDULRASHID-oy5ci
    @ABDULRASHID-oy5ci 2 ปีที่แล้ว

    JAHAN AAP NE SOLAR INSTALL KARNA HOTA HA,EK DIN PEHLY VIDEO K ZARRIAY BATA DIA KARAIN TA K AGAR KISI NE AA KAR DEKHNA HO TO DEKH SAKY.

  • @raowahab1431
    @raowahab1431 ปีที่แล้ว

    چار بیٹیوں کی بجائے دو بیٹری لگا سکتے ہیں 15 کلو واٹ سسٹم ہے اوپر

  • @tatv4u457
    @tatv4u457 ปีที่แล้ว

    Switching mechanism ki wiring ki bhi video upload krien or diagram bhi.

  • @_theasmr
    @_theasmr 2 ปีที่แล้ว +1

    Mobile se pv ka angle kaisay maloom krty hn

  • @muhammadzakriya9560
    @muhammadzakriya9560 9 หลายเดือนก่อน

    Assalam walekum Sar Hamid hai aap khairiyat se Honge

  • @tayyabimranmahatir
    @tayyabimranmahatir ปีที่แล้ว

    Lithium Ion battery Kitna time nikalti hai kia kitnay ghantay nikalti hai Kia?

  • @eqabelectrician8980
    @eqabelectrician8980 ปีที่แล้ว

    Sir to is mai dubble. Invertr nhi milta like. Woth out net meter kam kary ga?