Bahi apk installer ne 16mm^2 wire use ki hai Is wire se 3 bore kabi b 40 hazar mn ni ho sakty log apko glt guide kr rhy hain Apk nabours ne 2.5 mm se earthing ki ho gi jo k useless hai wo ho jy gi 40k mn Here are details of your earthing that I observe 14,000rs 100% pure copper lightning arrester (brass mixing wala 6-7 hazar ka mil jata but again its useless) Approximately 220ft 16mm^2 cable (42 hazar rupees ) Earthing chemical (2500-3500rs) Conduits pipes bends sockets (5000-6000rs) Spds dc snd ac (8000-12000rs) 3 Bare copper strip bars (7500rs) Labour (10,000rs) Panel to panel earthing (6000rs) 3000-5000rs transportation material or labour ki (8000-10,000) Installer ka profit jis ki waja se apko kch krna ni prha ghar beth k sub kam ho gya..ap kud krwaty to kafi expensive prhta or pure copper chezain na miltain apko 10,000 profit bikul jaiz hai apko itni khuwari se bachaya usne logon ki baaton mn na aain 40 hazar wali earthing usless hoti hai more then 50 ohms Ap ki earthing standards pr hai I am taking from my personal experience
زبردست ❤
ماشاءاللہ ماشاءاللہ ماشاءاللہ بہت خوب جناب والا آپ کو سلام کرتے ہیں ملتان پاکستان میں رہتے ہوئے ہیں اللّٰہ تعالیٰ سلامت رکھے آمین ثمہ آمین یا رب العالمین
Ameen jzak allah bhai Allah pak Apko b slamat rakhy❤️
Theek ho gya pa g shukr hy aap ne bta dia❤
Bore main sath aik inchi ka pipe or b dalna hota hai ta k waqtan fawaqtan pani dal sakain bore main
Ahho enj e gl ay pai tussi bhht acha mashwra de ry ho😅
Please kindly mention bore size ?.
Hi Amjad thanks for watching 😊
Bore depth depends on area but it should be approximately 30 to 35 feet.
Q
Bahi apk installer ne 16mm^2 wire use ki hai
Is wire se 3 bore kabi b 40 hazar mn ni ho sakty log apko glt guide kr rhy hain
Apk nabours ne 2.5 mm se earthing ki ho gi jo k useless hai wo ho jy gi 40k mn
Here are details of your earthing that I observe
14,000rs 100% pure copper lightning arrester (brass mixing wala 6-7 hazar ka mil jata but again its useless)
Approximately 220ft 16mm^2 cable (42 hazar rupees )
Earthing chemical (2500-3500rs)
Conduits pipes bends sockets (5000-6000rs)
Spds dc snd ac (8000-12000rs)
3 Bare copper strip bars (7500rs)
Labour (10,000rs)
Panel to panel earthing (6000rs)
3000-5000rs transportation material or labour ki
(8000-10,000) Installer ka profit jis ki waja se apko kch krna ni prha ghar beth k sub kam ho gya..ap kud krwaty to kafi expensive prhta or pure copper chezain na miltain apko
10,000 profit bikul jaiz hai apko itni khuwari se bachaya usne logon ki baaton mn na aain
40 hazar wali earthing usless hoti hai more then 50 ohms
Ap ki earthing standards pr hai
I am taking from my personal experience
AK 3 Earth k Liye Kam karega
Bhai Kya pochna cha ry ho AP ?
Vo poch rahy k 1 hi bore mein 3 earthing kr lein to vo thek ha? Same question ?
Yes. AC current ke liye 1 hi kafi hai.