DON'T Buy This Type of HVAC System!! | Common Problems...

แชร์
ฝัง
  • เผยแพร่เมื่อ 26 ต.ค. 2024

ความคิดเห็น • 147

  • @lj6672
    @lj6672 ปีที่แล้ว +36

    For the guys who are new to the trade. The unit had a small amount of refrigerant in it before he added the nitrogen. Before he opened his manifold it was at 45psi standing pressure. The nitrogen will help force the refrigerant out to pick up with your leak detector

    • @realSamAndrew
      @realSamAndrew ปีที่แล้ว +1

      At 2:00 when he first connected the hose, the refrigerant pressure was negative, basically flat.

    • @lj6672
      @lj6672 ปีที่แล้ว +1

      @@realSamAndrewwith the unit low and the compressor running it will pull your suction into a vacuum

    • @realSamAndrew
      @realSamAndrew ปีที่แล้ว

      @@lj6672 I didn't think the compressor was running. I thought he just hooked it up to get an instant reading. Are you sure the unit was already on at the time the hose went on?

    • @lj6672
      @lj6672 ปีที่แล้ว +3

      You can hear the compressor, metallic sound. He turns the breaker off afterward. I like to put gauges on before I turn on the unit for this reason. Watch the pressure get pulled down to zero if it’s really low on charge

    • @realSamAndrew
      @realSamAndrew ปีที่แล้ว

      @@lj6672 I see and hear it now. 👍

  • @elijahbrown9738
    @elijahbrown9738 ปีที่แล้ว +11

    All good.... But where does the title of the video come in to play?

  • @Mikereid1998
    @Mikereid1998 ปีที่แล้ว +9

    been watching for a year, and finally got hired as an apprentice with a small family owned business! i am very excited to start working in trade, thanks for the great videos!

  • @number1pappy
    @number1pappy ปีที่แล้ว +2

    I can tell by the way you pay attention to details,your truck is well organized and clean and how you carry yourself that your an outstanding HVAC tech! Someone like you is an exception where i live. Other hvac techs could learn a few things from you! If your a home owner reading this and you find someone like this ,do whatever it takes to keep him!

  • @leealtmansr.3811
    @leealtmansr.3811 ปีที่แล้ว +7

    Your title says: "Don't Buy", don't buy a Rheem/Rudd or a package system? In my area, Rheem/Rudds are very good systems. Also we almost only have packages. Miss leading title.
    As for your video, it would be helpful if you state how low it was. Keep it legal.

    • @MrJayray63
      @MrJayray63 ปีที่แล้ว +2

      I’ve seen lots of those old rheems still kicking after 15-20 years

    • @archstanton9703
      @archstanton9703 ปีที่แล้ว +2

      The lowest quote we got to replace our 19 year old 3.5 ton 12 SEER RTU Tempstar is for a Rheem 3.5 ton 14 SEER package heat pump. The next best price is on Day and Night and Ruud (Rheem) package units. Rheem and Ruud package units are the most commonly found around here in this part of AZ. We’re leaning towards Rheem because parts are readily available here and a couple of friends recommended the contractor. Our heat pump didn’t have any Freon left and would have cost $800 to install some kind of stop leak and R22 with no guarantee it would work, so we’re going to have it replaced.

    • @AlanSanderson-u4t
      @AlanSanderson-u4t 6 หลายเดือนก่อน

      @@MrJayray63My Rheem was installed in 1999 and I have had to replace a hot surface igniter and a control board.

    • @MrJayray63
      @MrJayray63 6 หลายเดือนก่อน

      @@AlanSanderson-u4t not too shabby

  • @chiefjoseph8154
    @chiefjoseph8154 ปีที่แล้ว +6

    Retired HVAC tech. My 23 yr old R22 is still going strong! There’s advantages to being able to repair your own equipment. And having plenty of R22!

    • @sidviscous5959
      @sidviscous5959 ปีที่แล้ว

      My mother had an old Singer that ran for I think 25 years in South Georgia. Amazing.

  • @DeAnda92
    @DeAnda92 ปีที่แล้ว

    Really enjoyed taking us with on this call. Keep up the great content!!

  • @willholgate8136
    @willholgate8136 ปีที่แล้ว +1

    Just started watching bout a month ago from Az..I'm a service tech 3 yrs in, love the videos, some good stuff, stay cool and safe out there buddy...

  • @b-2466
    @b-2466 ปีที่แล้ว +16

    Always a good day when quality hvacr uploads a video. 👊🏻

  • @jhill.7216
    @jhill.7216 ปีที่แล้ว +2

    I literally just started working in the hvac feild , this week was my first and I went to hvac school for 2 years and it’s definitely worth it

  • @BBYERS27
    @BBYERS27 ปีที่แล้ว +1

    I always enjoy watching your content. I appreciate your attention to detail and your industry experience that you share.
    I’ve recently started my own hvac company. So far I’m truly enjoying the challenge of learning the business side of the trade. It is definitely a lot different than just being a tech. If you don’t get out there and generate calls, your family don’t eat. Watching your content definitely was one of the inspirations to go out on my own. Thanks again for all that you have shared.

  • @TCHAVEZGAMES
    @TCHAVEZGAMES ปีที่แล้ว +4

    Thank you for all the time you put into the videos. Your great at what you do and a lot of people can learn from you. Your commitment to the trade and the customer are admirable.

  • @jerrynonofbss2588
    @jerrynonofbss2588 ปีที่แล้ว +2

    So, don't buy this type of system, meaning packaged units? I was expecting what brand name not to buy.

  • @cameronhulse
    @cameronhulse ปีที่แล้ว +1

    We need more vids! Just you doing your job is awesome. Its nice to see someone do their thing so I can better prepare myself and see how someone else does it.

  • @mattluongo7763
    @mattluongo7763 ปีที่แล้ว +1

    You ott clarify for the new techs that the unit in the video was out of refrigerant and it is not okay to mix nitrogen with a system that still has some of its charge left, only a trace amount is to be added with the nitrogen.

  • @kencrane6420
    @kencrane6420 ปีที่แล้ว +3

    So either I'm not getting something or the title of this video is misleading.

  • @ajetmech2002
    @ajetmech2002 ปีที่แล้ว

    Appreciate the Professionalism. Organized well prepare with equipment and knowledge. Great video.

  • @MICHAELTHOMPSON-sf1it
    @MICHAELTHOMPSON-sf1it ปีที่แล้ว

    Love the Gree Flexx in the background. We have installed many of them already this year and really like them. Thanks for sharing all of your videos!

  • @MetalDetectingwithCZkidd
    @MetalDetectingwithCZkidd ปีที่แล้ว

    Nicely done. I did not see the standing pressure before starting it up and did notice the negative low side. Fooled me.

  • @wagnergitirana
    @wagnergitirana ปีที่แล้ว

    Very helpful indeed! Thank you . Cheers from NW Arkansas, soon returning to my home in Texas 🍺

  • @johnsherk7699
    @johnsherk7699 ปีที่แล้ว

    Happy National HVAC Tech Day!🎉

  • @MinnesotaHvAc
    @MinnesotaHvAc ปีที่แล้ว +1

    A tech should always have the conversation before adding nitrogen to a system. As reclaiming or venting would be needed after adding nitrogen. First miss. Leak check good and not stopping after first find is great. I would hate to have one of my techs jump to nitro and not have the conversation before.

    • @mannys9130
      @mannys9130 ปีที่แล้ว

      Per the EPA it is acceptable to install a small amount of refrigerant with nitrogen fill for leak detection purposes using a very sensitive sniffer device. Many leaks won't actually leak until they're under the high operating pressure, which is why the N2 is needed to fully pressurize the small quantity of refrigerant.

  • @JuanSanchez-ss8ys
    @JuanSanchez-ss8ys ปีที่แล้ว +1

    Nice work positive Chang out

  • @michaelnash8435
    @michaelnash8435 ปีที่แล้ว +4

    Don't buy Rheem is a little whiny, isnt it? Trane has had major issues with leaks and so has just about every other brand out there. The new ones use bohn coils, are those junk too? Are ADP coils impervious to leaks? I'm genuinely curious what your thoughts are.

    • @miniman9198
      @miniman9198 ปีที่แล้ว +1

      As I guy who installs Day & Night I’m just gonna say that ADP coils definitely leak 😂 also my all time favorite units are the early to mid 2000s Rheem units. Simple and bulletproof. Sadly a lot of them are going the wayside due to age, but they’re still solid the ones that do run!

    • @miniman9198
      @miniman9198 ปีที่แล้ว +1

      Also I do alot of refrigeration work and I only install Heatcraft/Bohn equipment so 🤷‍♀️ no complaints

    • @Sctronic209
      @Sctronic209 ปีที่แล้ว +2

      Your title is not a fair assessment. That’s a pretty old unit, every brand have had leaks and still do.

    • @michaelnash8435
      @michaelnash8435 ปีที่แล้ว

      @@miniman9198 I prefer heatcraft for refrigeration as well, but I've also set Russell, which is a Rheem brand. No issues with either, but heatcraft still edges out Russell for me.
      My business is a Rheem Pro Partner, so I'm probably biased. However, I could (and would) set something better if I felt like there was a better manufacturer. I have yet to have a warranty claim denied and they always take great care of my issues...for the most part. I still think most of them could build a bulletproof unit and sell it for what it's worth, but instead engineer a unit designed to last 12 years. Just my opinion.

  • @matthockman
    @matthockman 27 วันที่ผ่านมา

    Thanks Zack!

  • @carloscorona6112
    @carloscorona6112 ปีที่แล้ว +4

    The title is very confusing and misleading

  • @robalexander7348
    @robalexander7348 ปีที่แล้ว

    Nice video Zac, i do enjoy watching your videos down under here in Australia 👍

  • @edwinayala6145
    @edwinayala6145 ปีที่แล้ว

    Outstanding video! Thank you for the clear and concise explanation

  • @anthonypal1149
    @anthonypal1149 ปีที่แล้ว

    Can you do a video on how to read mechanical plans?

  • @TheDave5619
    @TheDave5619 ปีที่แล้ว +1

    I’m not the sharpest tool in the shed but I have a difficult time trying to find leaks… I normally bump the pressure up with nitro to the design pressure on the low side and sniff with my leak detector (field piece slr8) I’ve used it a hand full of times and had not much luck. Seems like it’s very sensitive at times or gives false dings. Any advice would be appreciated.

    • @BigMitchFit
      @BigMitchFit ปีที่แล้ว +1

      Oil stains and soap bubbles are my go to tell tale signs of where to look brother

  • @luisflores8266
    @luisflores8266 ปีที่แล้ว +1

    What do you do once you find the leak with the nitrogen in the system?? I’m sorry ahead of time for this dumb question. Still learning.

    • @evasquezapm
      @evasquezapm ปีที่แล้ว +1

      There are no dumb questions 🙋‍♂️.

    • @MikeLove-wq1zh
      @MikeLove-wq1zh ปีที่แล้ว +1

      When you find the leak you let the nitrogen out and braze where the leak was founded.. Or change the part hope this helped

  • @4g_hvac
    @4g_hvac ปีที่แล้ว

    I always check heat exchanger as well even tho it’s out of season it’s still good to know awesome video!! I would love to start makin videos I’m just terrible on camera lol !!

  • @Hvacsteve69
    @Hvacsteve69 ปีที่แล้ว

    Bluon will always be trash I remember when you had to call them to set up an account the entire app is glitched you can even use search bar at top it’s higher than where you can click try to get free hat app crashes. Wouldn’t waste your time for a $5 made hat. Nice video though.

  • @sawdust85222
    @sawdust85222 ปีที่แล้ว +2

    So what kind of unit should i not buy? Or is this "just another click bait video"
    Click bait screams to me, im not good enough so i have to try and trick you into watching.

  • @bp0100
    @bp0100 ปีที่แล้ว

    What would qualify as extremely low on refrigerant? I’m just getting into leak detection now. I use to always just top it off. I like the bumping it up with nitrogen idea. I had trouble finding a leak with light wind the other day.

    • @Chemp95
      @Chemp95 ปีที่แล้ว

      I like to look at standing pressures when system is off and everything is equalized if it's under 5 degrees outdoor ambient in saturation temp on your gauge you typically will have less than half total install charge

  • @double_patchoutdoors
    @double_patchoutdoors ปีที่แล้ว +1

    The title was misleading. Didn’t say anything about how bad those yorks are 😂

  • @1BadMofo
    @1BadMofo ปีที่แล้ว

    Learn a lot from your videos

  • @joshwaloveslotr
    @joshwaloveslotr ปีที่แล้ว

    I have one of these units. I cant get anyone to work on it. Its new as of 2020. Any ideas?

  • @DakodaHammonds
    @DakodaHammonds ปีที่แล้ว

    Need the info on stratus! It changed everyone thing for leak check for me

  • @jonathanangieri153
    @jonathanangieri153 ปีที่แล้ว

    I appreciate your videos very much as I am one of those guys you mentioned at the end of the video! So are you pumping nitrogen in without pumping down or is that only because there was next to nothing in the system,? Would you still do that if the unit still had 50% of its freon? Thanks man!

    • @michaelnash8435
      @michaelnash8435 ปีที่แล้ว +1

      If the pressures look just a little low, you'd be best to recover, but with the low side at -2.4psi it was a safe bet there wasn't much charge left. I'd have still made sure it wasn't a closed txv first, but he may have had some history on the unit and knew it was losing charge from the start.

  • @OIC-es6pi
    @OIC-es6pi ปีที่แล้ว

    What are you using on the condensate line? I've never seen that before.

  • @jameswasher3938
    @jameswasher3938 ปีที่แล้ว

    Are these package units common in your area? I never see these out here in the west (CA/NV/OR)

    • @eastsidepyro2685
      @eastsidepyro2685 8 หลายเดือนก่อน

      Plenty here in Cali, I think they are knock off Rheems

  • @CaptainRon1913
    @CaptainRon1913 ปีที่แล้ว +2

    Not installing another data mining app in exchange for a hat. geeze... So, don't buy what type of system? you never say

  • @jeffkablock3229
    @jeffkablock3229 ปีที่แล้ว

    man i am 61 years old been using rudd for 40 years

  • @patterrick1
    @patterrick1 ปีที่แล้ว

    where do you have peace to film at work? Seems every call I get customer stands right there talking whole time im working, lol

  • @garciajr913
    @garciajr913 ปีที่แล้ว

    Have you had any issues with your nv2500? I have same truck with 140k miles bought it with 70k miles 2 years ago now giving me nothing but issues!

  • @badawesome3047
    @badawesome3047 ปีที่แล้ว +2

    Don't buy this type of HVAC system?? What type?

  • @theusername07
    @theusername07 ปีที่แล้ว

    Were you a resi tech before you started on your own?

  • @thesilentonevictor
    @thesilentonevictor ปีที่แล้ว

    Great video zack

  • @emylrmm
    @emylrmm ปีที่แล้ว

    those condenser coil ends sure were rusty!

  • @Chris-ru3ri
    @Chris-ru3ri ปีที่แล้ว

    Rheem /Ruud indoor coils always leak

  • @SirFlushAlot
    @SirFlushAlot ปีที่แล้ว

    bro your brave leaving your doors open on the van lol.

  • @DA-PICKLES-VR
    @DA-PICKLES-VR ปีที่แล้ว

    Zach, are you really having success adding nitrogen to an empty system and getting your refrigerant leak detector to go off?

    • @BabyKMoney
      @BabyKMoney ปีที่แล้ว +1

      You have to add some 410 they are calibrated to hit on refrigerant

  • @Badger.-
    @Badger.- ปีที่แล้ว

    Hey Zac, great video as always! I have a question about the install process. When you pressure test with nitrogen does it matter what direction the nitrogen gets pumped through? Same with the vacuuming process. What line do you pump from? Lastly does a TXV or piston affect the pressure test or vacuuming in any way? For example is it possible for a TXV to close and prevent nitrogen/vacuum from reaching both sides of the system?

    • @TCHAVEZGAMES
      @TCHAVEZGAMES ปีที่แล้ว

      I wouldn’t think it would make a difference, it’s usually easier to fill from your service ports at the condenser. In rough in situations I cap the inside and install my own shraders outside to pressure test. When you vacuum you can use a single hose setup or a dual hose setup.

    • @danielwalker1922
      @danielwalker1922 ปีที่แล้ว

      I was taught to fill only in liquid line to make sure txv is working

    • @chandlervoit4630
      @chandlervoit4630 ปีที่แล้ว +1

      I always fill nitro the way the refrigerant flows, then when emptying I go out the suction. Then when I open the system I open suction first then liquid

    • @michaelnash8435
      @michaelnash8435 ปีที่แล้ว

      ​@@chandlervoit4630 interesting...I've never read anything saying that there's a 'correct' way, but I do follow the same steps as you but I open liquid side first. I've never really thought too much about it I guess. I just do it by habit now. 😅

    • @jonathanrobinson2949
      @jonathanrobinson2949 ปีที่แล้ว

      From my personal experience in hvac, yes it is possible for a txv to close off and prevent you from pulling a true vacuum. If you pull a vacuum and add refrigerant, you will now have noncondensibles in your system making. I have had quite a few txv metering devices cause premature compressor burnouts. If the compressor is already bad, then I can't test the txv by my refrigerant pressures. Instead, I blow nitrogen through the liquid line, and if it flows freely, than my txv is not locked shut. I am aware that this does not always let me know if I have a bad txv, but it does let me know if it is stuck closed. Another way to know you have a txv that is locked closed is if you are pulling a vacuum and the micron guage keeps jumping all over the place. If your micron guage is jumping all over, than you either have a restriction in the metering device, oil with moisture in it, oil sitting in your hose or evap coil, or a leak. You may also have a restricted filter drier. Regardless, always replace the filter drier for assurance.

  • @Dan-wg5fg
    @Dan-wg5fg ปีที่แล้ว

    How is your leak detector picking up on nitrogen?

    • @maness2112
      @maness2112 ปีที่แล้ว

      The nitrogen was added to a low charge of refrigerant.

    • @MrJayray63
      @MrJayray63 ปีที่แล้ว

      As long as there’s a little trace of refrigerant it’ll be able to sniff it out

    • @Dan-wg5fg
      @Dan-wg5fg ปีที่แล้ว

      @@MrJayray63 ok I can see that. Never really done that myself but might give It a go next time.

  • @vickikieft6108
    @vickikieft6108 ปีที่แล้ว

    Question what happened to your helper that you had?

  • @geedaman
    @geedaman ปีที่แล้ว

    Do you charge the customers?

    • @eastsidepyro2685
      @eastsidepyro2685 8 หลายเดือนก่อน

      No he works for free 🤦‍♂️

  • @aspensulphate
    @aspensulphate ปีที่แล้ว +3

    Did I miss the part where you discussed avoiding this type of HVAC system? You discovered a leaky system, and replaced the unit. Is it worth it to lose viewers to hang a clickbait title on your vid? I won't be back.

    • @safffff1000
      @safffff1000 ปีที่แล้ว

      Bingo, who hit it on the head, so where the ac to avoid.

    • @brianbrannanHVACTech
      @brianbrannanHVACTech ปีที่แล้ว

      @@safffff1000dudes a sponsor guy, not a real tech

  • @dannysmith713
    @dannysmith713 ปีที่แล้ว

    Got my hat ordered. Thx

  • @mikestevenson1819
    @mikestevenson1819 ปีที่แล้ว

    Service truck or NV2500 ?

  • @domfurious9273
    @domfurious9273 ปีที่แล้ว

    Is he done making videos?

  • @pnajera3938
    @pnajera3938 ปีที่แล้ว

    Hey brotha, what leak detector are you using?

    • @michaelnash8435
      @michaelnash8435 ปีที่แล้ว +1

      He's using the fieldpiece. I'll say that I love my dtek stratus though! Way better than the heated pentode days.

  • @edca8114
    @edca8114 ปีที่แล้ว

    So what year n model and size was that unit ??????

  • @mikefrayman5224
    @mikefrayman5224 ปีที่แล้ว +1

    Stay away from carrier, Reem and York

  • @pana5075
    @pana5075 ปีที่แล้ว

    Waoo no sabía que los detectores de refrigerante detectan Nitrogeno ????? 😅

  • @nepomucenoarcondicionado8447
    @nepomucenoarcondicionado8447 ปีที่แล้ว +1

    Meu amigo falo daqui do Brasil Rio de Janeiro ,muito bom seus vídeos
    Sou inscrito no seu canal 👍🏽

  • @xxjoigaxx
    @xxjoigaxx ปีที่แล้ว +1

    So why not include showing that changeout as well? Very lackluster video from you IMO.

  • @flexor212000
    @flexor212000 ปีที่แล้ว +1

    All that and you didn't even tell us which type of HVAC system not to buy.... wtf

  • @mdajaz542
    @mdajaz542 ปีที่แล้ว

    I'm form India AC technician .... Section pipe way coming ice???? Full ditels please

  • @hvacsolution589
    @hvacsolution589 ปีที่แล้ว

    #qualityhvacr Which camera do you use for your content.

  • @emiliolopez927
    @emiliolopez927 ปีที่แล้ว

    Rheem is # 1

  • @andygalindo8978
    @andygalindo8978 ปีที่แล้ว

    They should make those units not to rot out so easy.

  • @karlfair
    @karlfair ปีที่แล้ว

    Did you mix the nitrogen with the 410A?

    • @AARONJL92
      @AARONJL92 ปีที่แล้ว +2

      I've actually heard from HVAC school it's ok to mix R22 to find it faster. Once you're sweeping the system after the test anyway.

    • @maness2112
      @maness2112 ปีที่แล้ว +2

      Just added the n2o for leak checking. . The charge was probably to low anyway.

    • @Nickkerr666
      @Nickkerr666 ปีที่แล้ว +2

      He pressurized the system with nitrogen because it had hardly any refrigerant left in it, as you can see on his gauges when he hooks them up. The nitrogen forces any refrigerant out of the pinhole leaks allowing his sniffer to find them. Without nitrogen pressure, his sniffer tool more than likely wouldn’t have found a thing, as the outside air pressure is greater than the pressure inside the system, thus preventing any leaks from occurring.

    • @michaelnash8435
      @michaelnash8435 ปีที่แล้ว

      ​@@maness2112 The suction pressure was -2.4psi with the compressor running.

  • @cheponite2461
    @cheponite2461 ปีที่แล้ว

    Nice 🔥
    Where's Trevor?

  • @myHVAClife
    @myHVAClife ปีที่แล้ว +11

    The only thing an up and coming tech got from this is how to pimp your sponsors! Maybe try to actually explaining what you are doing and why you are doing it, "While you are are doing it"! No instructional value what so ever! Hope you got a good pay check from your sponsors! Never even explained why you should not buy this type HVAC system, remember the title, OH YEH! CLICK BAIT! SELL OUT I know you will hide my comment, that is OK, AS LONG AS I KNOW YOU READ IT!

    • @SteveMcFry
      @SteveMcFry ปีที่แล้ว +6

      Yea I feel you. His content is%100 clickbait. Used to be a good channel

    • @Kilcrops0914
      @Kilcrops0914 ปีที่แล้ว

      I'm totally with you on this one. This guy's videos have been worthless for a while now

    • @diyhvacguy
      @diyhvacguy ปีที่แล้ว

      I think it’s still informative to see what he is doing, but def could use some more commentary for sure.

    • @joerusso4645
      @joerusso4645 ปีที่แล้ว

      I just can’t trust a mechanic who is never dirty and doesn’t sweat! Everything appears to be stage for sponsorship

  • @cameronblades2394
    @cameronblades2394 ปีที่แล้ว

    How convenient.

  • @manschool4992
    @manschool4992 ปีที่แล้ว

    How do you keep your fingernails so clean? I'm doing up to 40 hours OT every 2 weeks and my hands are thrashed (yes I wear gloves). Hook a brother up on your secret.

    • @maness2112
      @maness2112 ปีที่แล้ว

      Wear gloves as much as possible.

    • @manschool4992
      @manschool4992 ปีที่แล้ว

      @@maness2112 LMAO. Dude I could double or triple glove and my hands would be thrashed. I thrash brand new milwaukee gloves in two weeks.

    • @maness2112
      @maness2112 ปีที่แล้ว

      ​@@manschool4992 milwaukee gloves are for electricians.

    • @manschool4992
      @manschool4992 ปีที่แล้ว

      @@maness2112 Dude. I work with a team of 43 commercial service techs. To a man, our hands are mangled mitts. To a man. I've seen high volume electricians too and their hands are mangled, dirty and calloused. This dudes hands are not high volume anything. That's a fact jack.

  • @hvacgoat9451
    @hvacgoat9451 ปีที่แล้ว +1

    You do a good job with your vids, oh and don't buy Mitsubishi City Multis either. Lol!

  • @dcarroll02
    @dcarroll02 ปีที่แล้ว

    Really could use another video right about now 😂

  • @jeffkablock3229
    @jeffkablock3229 ปีที่แล้ว

    your a young kidd and you have alot to learn lol

  • @mikefrayman5224
    @mikefrayman5224 ปีที่แล้ว +1

    Residential cooling is the simplest system in the whole industry. Most homeowners are able to repair their own units.

  • @chooisc5297
    @chooisc5297 ปีที่แล้ว

    He charged them 10,000 dollars 💩🤣💩

  • @elmerramirez1215
    @elmerramirez1215 ปีที่แล้ว

    Let’s do some work

  • @trcolem
    @trcolem ปีที่แล้ว

    Yasss!!!!!!!

  • @chrissipple1018
    @chrissipple1018 ปีที่แล้ว

    Bluon is crap and so is the app

  • @jimmydavis6846
    @jimmydavis6846 ปีที่แล้ว

    and as you know,,copper don't rust,,,just metal,,lol,,
    just seeing iron rust from water

  • @iwenive3390
    @iwenive3390 ปีที่แล้ว

    Every brand in 2010 had leaky coils. Get a real hat

  • @joeduca6071
    @joeduca6071 ปีที่แล้ว

    skip to 5:30 the rest is a waist of time

  • @wtfman5313
    @wtfman5313 ปีที่แล้ว

    Not cool with blowing Nitrogen into a system with unknow quantity of Refrigerant. Now you have to pull the charge and bill the customer for more (by weight) than you would have originally and you've got a useless mixed charge to deal with... Not criticizing, but that seems like a pain in the ass to me. Now, I've only ever worked commercial so I might be full of crap.. Please correct me if I'm wrong. Residential is not for me, but I like watching the vids..

    • @aaronburke2469
      @aaronburke2469 ปีที่แล้ว

      Going off his manifold reading. A morning fart has more vapor in it than that system has. System flatter than Paris Hiltons chest. I'm more curious how the hell he found that leak with leak detector with no refrigerant in there. 🤔

  • @italktoplanetsbaby
    @italktoplanetsbaby ปีที่แล้ว

    Ok.....Im confused. Did you dump nitrogen in w/ what was left on the system, or did you recover? Would what you recover be any good anyway because i assume youll suck outside air thru the leak hole...but i know the rest of the charge is gonna be worthless if you dump nitrogen in with it...🤯

    • @michaelnash8435
      @michaelnash8435 ปีที่แล้ว

      The low side pressure with the compressor running was -2.4psi. I doubt there was much there to recover.