TXV Replacement

แชร์
ฝัง

ความคิดเห็น • 108

  • @gsmboutiqueable
    @gsmboutiqueable 11 หลายเดือนก่อน +16

    I'm a HVACR technician, and I want to tell you something. You deserve all my respect from the moment you decided to flow nitrogen in the lines before brazing, ONLY the professional technicians understand the importance of the nitrogen when you are brazing, that's why the importance of Hvac academy or training programs.

    • @ApartmentMaintenancePro
      @ApartmentMaintenancePro  11 หลายเดือนก่อน +3

      Thanks bro appreciate it 👍

    • @jacobbell1934
      @jacobbell1934 27 วันที่ผ่านมา

      Well unfortunately companies are too greedy to invest in training

  • @sharonnwiggins371
    @sharonnwiggins371 ปีที่แล้ว +3

    Great job my friend. Thanks for all your hard work.👍🏽

  • @octaviofigueroafigueroa9794
    @octaviofigueroafigueroa9794 ปีที่แล้ว +1

    Congratulations for doing your best effort & thanks for sharing your learning experience curve.

  • @TheMinecraftACMan
    @TheMinecraftACMan ปีที่แล้ว +11

    Always a fan of people taking the time to know the equipment. A few tips if you'd like them:
    I didn't see you purge your manifold. Don't worry if you did it off camera, but it's pretty important if you're pumping a system down because if you don't you can end up with some air in the system. This can make your head pressure run abnormally high, and maybe cause a no-cool call later. This is one of those things that adds up over time though, the first time you probably won't notice, but eventually it can become an issue.
    Your compressor protection prevents the contactor coil from energizing, it won't do anything to stop you if you push it in manually. All it does is break the electrical circuit to the coil.
    The compressors used in residential split systems like these aren't meant to pump down that far. I recommend stopping when you get between 5 and 10 psi, you're only losing a few ounces at that point, and the nitrogen will take care of anything left in the lines that could produce phosgene while brazing.
    Didn't see if you deburred the liquid line after cutting. Not as critical as some make it out to be, but worth doing if you can.
    Not a tip exactly, but good job with the nitro and the wet rag.
    Might have gone a hair higher on the oxygen setting, that flame looked a bit heavy on the acetylene. But the joint looked OK.
    I recommend shutting the core tools before shutting the pump off. Also, they tend to trap a little bit of air in the mechanism when fully open, so try leaving them at a 30-45 degree angle, if 0 is open and 90 is closed.
    This one's a bit controversial, but in some situations it's OK to skip changing the drier. If the system wasn't suffering from a leak, and you pulled a proper vacuum, then it's generally OK to skip the drier. But if you have any reason at all to think you may have some moisture inside, then change it.

    • @ApartmentMaintenancePro
      @ApartmentMaintenancePro  ปีที่แล้ว +1

      Thanks Minecraft for the detailed reply - I didn't go back in look but purging the manifold is second nature to me I usually try and get it filmed 👍

    • @jimmyp5487
      @jimmyp5487 ปีที่แล้ว

      He’s a super tech 🕺

    • @TheMinecraftACMan
      @TheMinecraftACMan ปีที่แล้ว +5

      @@jimmyp5487 Nah. A super tech would look down on people for not knowing. I'm just trying to be haelpful.

    • @jimmyp5487
      @jimmyp5487 ปีที่แล้ว

      @@TheMinecraftACMan lol it’s all love brother 🤘🤘 stay safe out there

  • @samyz1660
    @samyz1660 ปีที่แล้ว +8

    To me you're a pro and better than some HVAC tech that I've seen. You did nitrogen while brazing that mean a lot to me. Good job

    • @ApartmentMaintenancePro
      @ApartmentMaintenancePro  ปีที่แล้ว +2

      Thanks I appreciate that - I used to do HVAC professionally with a company many years ago and lots of guys i worked with never flowed nitrogen while brazing

    • @Samlol23_drrich
      @Samlol23_drrich ปีที่แล้ว

      ​@ApartmentMaintenancePro no wonder. That was as professional of a job as I've ever seen.

    • @gsmboutiqueable
      @gsmboutiqueable 11 หลายเดือนก่อน +2

      I'm 1000000% agree only professional technicians understand the importance of the nitrogen in the brazing process.

  • @Zaphandyman
    @Zaphandyman หลายเดือนก่อน

    I like how you set it strait with the facts about being an apartment maintenance pro. I am as well, and even though I know a lot about many things, it doesn't mean I'm an expert on any of them.

  • @bonexsher
    @bonexsher ปีที่แล้ว +20

    WOW looks like wrong line set for condenser

    • @letsgethigh4202
      @letsgethigh4202 11 หลายเดือนก่อน

      I was curious what kind of issue will that cause if any?

    • @rodneyhendricks8260
      @rodneyhendricks8260 หลายเดือนก่อน

      EXACTLY.....Probably the issue all along. Major Miss🤐

  • @LexVance
    @LexVance ปีที่แล้ว +7

    Sargent Vance from the nitrogen police here. Can we talk outside? 🤣
    Great video Dave!

    • @ApartmentMaintenancePro
      @ApartmentMaintenancePro  ปีที่แล้ว

      Bro I almost sh*t myself reading this comment lol thanks Lex for stopping by 🤣

  • @Fitjaycjr
    @Fitjaycjr ปีที่แล้ว +1

    Great video, sure did learn some things!

  • @alfonsotoscano5096
    @alfonsotoscano5096 10 หลายเดือนก่อน

    Very good job. Thanks for sharing

  • @JamesP33R
    @JamesP33R 11 หลายเดือนก่อน +1

    I would have loved to see the gauge numbers before the replacement. I peeked over the tech shoulder when they were out and I saw some numbers that may have been indicative of a TXV problem. Head 358, SC 12.2, Vac 96, SH 27 He's convinced that I just need to clean the Evap Coil. Yes it needed it. White slime. They want $1200 to pull and clean. So, I have climbed into the underside of the air handler and got it pretty clean. Shop vac, coil cleaner, and combs. Also installed a UV lamp in the a-frame now. No improvement on the indoor D-T, 10-11 degrees. Good airflow. I guess I may need to call someone else out to hook up again and see what the numbers are now after the cleaning.
    Nice work!

    • @ApartmentMaintenancePro
      @ApartmentMaintenancePro  11 หลายเดือนก่อน

      I don’t think those readings indicate a bad txv - hard to tell though without testing the airflow. Low airflow will actually give you a higher than normal delta t

    • @jsecret1404
      @jsecret1404 14 วันที่ผ่านมา

      thats not a TXV problem. if the coil was dirty then the blower was the same way. 1/8 inch dust on that blower wheel will significantly change airflow. if its a high efficiency furnace under the coil then its got a secondary heat exchanger that is most likely plugged the same as the coil.

  • @justwork_hvac
    @justwork_hvac ปีที่แล้ว +7

    Great stuff brother... Just my opinion in the apartment industry they shouldn't have txv ..the maintenance guys/gals have to many other work orders to be messing with txv

    • @ApartmentMaintenancePro
      @ApartmentMaintenancePro  ปีที่แล้ว +1

      Ya, this is something that usually gets vendored out in my area

    • @techfive7202
      @techfive7202 ปีที่แล้ว +2

      Not to mention the amount of misdiagnosis

  • @Kilcrops0914
    @Kilcrops0914 ปีที่แล้ว +3

    You can connect your micron gauge directly to the port of your CRT on your liquid line and get a more accurate reading. Good job, that air handler looks like a pain to work on

    • @jman0870
      @jman0870 11 หลายเดือนก่อน

      That is just as inaccurate as putting it on the pump fella. If you want an accurate reading it needs to be located at the evaporator.

  • @jimmyp5487
    @jimmyp5487 ปีที่แล้ว

    Is that Baltimore? No matter what the super techs say, that was a good repair bro. You followed the correct steps alot better than most “techs” out here 🤘🤘🇺🇸🇺🇸

  • @seadeas
    @seadeas ปีที่แล้ว

    Good job 👍

  • @southtexasprepper6605
    @southtexasprepper6605 10 หลายเดือนก่อน

    Great video

  • @Hvacstuff89
    @Hvacstuff89 ปีที่แล้ว +4

    Bro that suction line looks messed up at at the condenser! Hopefully the lineset is very short and not long....
    Love your videos man! Upset you got in trouble for filming indoors. Hopefully you can do more of those vlog blog things I really liked them

    • @ApartmentMaintenancePro
      @ApartmentMaintenancePro  ปีที่แล้ว

      Hahah ya I had nothing to do with that suction line 🤣 but that’s what happens when you don’t have the right parts for the job - I’m still salty about not being able to vlog anymore but I will be pumping out these rooftop unit repairs all season 👍

  • @robd7365
    @robd7365 3 หลายเดือนก่อน

    Excellent 👍just curious, what symptom was present to condemn the txv?

  • @davidlanfair
    @davidlanfair ปีที่แล้ว

    Good Job!

  • @marcosmezamaldonado
    @marcosmezamaldonado 4 หลายเดือนก่อน

    Your awesome man!

  • @jerrylockhart3069
    @jerrylockhart3069 ปีที่แล้ว

    Yep 5/8 line on a 7/8” crazy 😮❤

  • @tonyp6088
    @tonyp6088 8 หลายเดือนก่อน

    Great work mate! Very professional in my opinion.... and I'm a professional 😅

  • @tanyamanhid625
    @tanyamanhid625 ปีที่แล้ว

    Hell sir. I have a problem also with my txv which is 7tr capacity. It is ok to replaced with 7.5tr txv?

  • @ATJ94
    @ATJ94 ปีที่แล้ว

    Had so many TXV go bad last year 🤦🏾‍♂️ great video

  • @garza7676
    @garza7676 ปีที่แล้ว +1

    Great video . Gangsta how you tell it like it is . I’m not a technician . Lol

  • @tmmyjay
    @tmmyjay 3 หลายเดือนก่อน

    Great video. Is the nitrogen actually flowing through or just sitting in the line?

  • @dealdoe5369
    @dealdoe5369 หลายเดือนก่อน +1

    Great video but is it necessary to replace the filter drier as well when opening up the system ?

    • @ApartmentMaintenancePro
      @ApartmentMaintenancePro  หลายเดือนก่อน +1

      The system was opened but the filter drier inside was never exposed, so, a lot of people will disagree with this and a lot will do the exact same thing

  • @sheldon8115
    @sheldon8115 ปีที่แล้ว

    I think you did fine. .👍

  • @kodieivie
    @kodieivie ปีที่แล้ว +1

    Hope they pay you well.. just wanted to say that liquid line drier was never exposed to the atmosphere so theres no need to change it in those goodmans.. great job

  • @jerrylockhart3069
    @jerrylockhart3069 ปีที่แล้ว +1

    You lucky man you got plenty of room to change that TXV ❤😢😅

  • @ecoTOPeco
    @ecoTOPeco หลายเดือนก่อน

    How to choose right txv?

  • @wd8557
    @wd8557 ปีที่แล้ว +2

    Not to bad, However in the future slide the nut back from the flare, seat the flare on the fitting, slide the nut down and tighten by hand as tight as you can get it, then finish it off. This will make sure that the flare is 100% seated properly.

  • @altyndom7039
    @altyndom7039 ปีที่แล้ว

    Bad Santa decided to earn an honest living by doing HVAC maintenance.

  • @weatherfordmobil6056
    @weatherfordmobil6056 ปีที่แล้ว +1

    Thank you showing your skills.. where i can buy hvac parts without Tech License

    • @ApartmentMaintenancePro
      @ApartmentMaintenancePro  ปีที่แล้ว

      Just about any website that sells them. Will need a epa card for refrigerant purchases of more than a few pounds though

  • @flyobdab7746
    @flyobdab7746 ปีที่แล้ว

    Are most TXV valves universal based on tonnage, line size and freon type? Where's the best place to buy one online?

    • @Freonleon
      @Freonleon ปีที่แล้ว +1

      Freon is a brand it’s called refrigerant

    • @Hamasisfilthytrash
      @Hamasisfilthytrash ปีที่แล้ว

      Join the union and get a real 5 year education while working and you’ll have your answer instead of asking this clown

    • @ApartmentMaintenancePro
      @ApartmentMaintenancePro  ปีที่แล้ว +1

      They are not universal. Refrigerant needs to match and there’s some wiggle room in tonnage but always check with the manufacturer specs not joe shmo the ac guru down the street

  • @bmillwood6666
    @bmillwood6666 ปีที่แล้ว

    They put leak test mode on the gauges for a reason. It's the best mode on the gauges.

  • @baris5592
    @baris5592 10 หลายเดือนก่อน +1

    TXv ısı algılayıcıyı yalnış yere taktın kapiler borunun önünde olması gerek arkasında değil 7:35 dk bakabilirsin bu sekilde txv düzgün çalışmaz.

    • @ApartmentMaintenancePro
      @ApartmentMaintenancePro  10 หลายเดือนก่อน

      Not sure what you mean about the capillary pipe. The sensor bulb is fine where it was installed

    • @baris5592
      @baris5592 10 หลายเดือนก่อน

      Siz kapiler boruyu bulb in önüne taktınız doğru olan bulb in arkasına takılması gerek yani önce bulb 5 veya 10 cm sonra kapiler takılır txv klavuzuna bakabilirsin doğru bulb ve dış denge bağlantısı nasil olur

  • @garza7676
    @garza7676 ปีที่แล้ว +1

    Manufactures started putting filter drier inside the condenser as a way to deter warranty work on bad compressors due to installers not putting filter driers.

  • @dw9811
    @dw9811 7 วันที่ผ่านมา

    @5:30 is where you charged them $3,000 for that "problem" you found.

  • @michielcutrell8893
    @michielcutrell8893 2 วันที่ผ่านมา +1

    Cut off txv bulb and braze eighth inch copper tube too quarter inch male shrader port. Put shrader back in port after brazing and pressure power head with nitrogen to open txv. Save all these steps of removing valve. This is only emergency fix.

  • @CobraPRIME99
    @CobraPRIME99 ปีที่แล้ว

    Nice! I just had a new ac installed half the price with a small 3 man company doing it. The big companies wanted way too much $$

  • @peenopiani7209
    @peenopiani7209 ปีที่แล้ว

    Hi dear sir:txv buble shouldnt be insttaled on top of return line.3oclock position is right🙌

  • @richsasz1544
    @richsasz1544 7 หลายเดือนก่อน

    Can you come to my house? My txv valve is not operating. Is Florida too far? lol.

  • @jaimedpcaus1
    @jaimedpcaus1 ปีที่แล้ว

    Wow, if you've learned all this from TH-cam (and not gone to school) dang. You seem to have also made a huge investment in tools(hundreds maybe thousands). And if I didn't know any better, I would say that you're in the industry and have been for a long time. I just began learning from TH-cam and I wouldn't feel confident doing what you just did. 😅😅😅

    • @ApartmentMaintenancePro
      @ApartmentMaintenancePro  ปีที่แล้ว

      I learned most of what I know today from 20 years of experience, before TH-cam (I've been watching youtube for about 4 years or so to keep up to date and keep learning new things)

  • @jacobbell1934
    @jacobbell1934 27 วันที่ผ่านมา

    Personally, I wouldn’t worry about saving any company money. I save money for customers all the time when it’s their home. Usually do free leak searches and sometimes give them free Freon if they aren’t rich people(I charge rich people everything). But a company can suck it and there’s no reason for you to save them money ever

  • @jonnyrotten9676
    @jonnyrotten9676 3 วันที่ผ่านมา

    i bet you wouldnt try that with a package unit trane lol

  • @robertcouffer7908
    @robertcouffer7908 ปีที่แล้ว

    You replace the parts after the Pros Diagnosed it for you !!

  • @soledoutcustoms3125
    @soledoutcustoms3125 ปีที่แล้ว

    I was quoted $3k for this same issue

  • @AllEnemiesForeign_AndDomestic
    @AllEnemiesForeign_AndDomestic ปีที่แล้ว +1

    I don’t understand. Why call a company when they have you? I have an property I take care of but only to change out equipment the maintenance crew does the repairs.

    • @ApartmentMaintenancePro
      @ApartmentMaintenancePro  ปีที่แล้ว

      I've been doing a few compressor/txv/condenser change outs a week so far. Hopefully many more this summer when it starts hitting 100 degrees.

  • @5822huron
    @5822huron ปีที่แล้ว +1

    Get a captain hook tip

    • @ApartmentMaintenancePro
      @ApartmentMaintenancePro  ปีที่แล้ว +1

      I just heard about that from the comment section looks very handy

    • @5822huron
      @5822huron ปีที่แล้ว

      @@ApartmentMaintenancePro game changer

    • @Hamasisfilthytrash
      @Hamasisfilthytrash ปีที่แล้ว +1

      Or get better at brazing!!!!!

    • @5822huron
      @5822huron ปีที่แล้ว

      @@Hamasisfilthytrash whatever it takes

    • @Hamasisfilthytrash
      @Hamasisfilthytrash ปีที่แล้ว

      @@5822huron the true words of a hack!!! Or get a proper education and get paid properly to do the job properly with the proper skills

  • @rodneyhendricks8260
    @rodneyhendricks8260 หลายเดือนก่อน

    Absolutely No Disrespect. Improperly sized line sets will definitely cause issues like the TXV is failing. At the beginning of the video when the pump down is explained, the low size line set is absolutely undersized.

    • @ApartmentMaintenancePro
      @ApartmentMaintenancePro  หลายเดือนก่อน +1

      According to the literature of the install manual it is not.

  • @jonrucker2126
    @jonrucker2126 หลายเดือนก่อน

    lol that poor compressor, line set is way to small on the vapor side. She is starving

    • @ApartmentMaintenancePro
      @ApartmentMaintenancePro  หลายเดือนก่อน

      How do you know that? You don't even know how long this lineset is? Did you read the install manual to determine this?

  • @user-ql2bz8on7m
    @user-ql2bz8on7m หลายเดือนก่อน

    I’ll tell you what not bad

  • @jerrylockhart3069
    @jerrylockhart3069 ปีที่แล้ว

    If heat pump shut both before killing power 😮❤😂😅😱🥵

  • @ICONBADGTA
    @ICONBADGTA ปีที่แล้ว +1

    Why would you cut out the drier?
    When it's new, do you open it up and remove the new refrigerant?
    Cause what you did is just like putting a new system in work wise... When you recovered the refrigerant and shut the valves off, you secured it, and thus no "AIR" got into the lines and what did you pulled a proper vacuum on just like they did when it was brand new.
    It would be silly to remove it for no reason. Long as you pulled a vacuum correctly, and your micron gauge is (NOT) where it's supposed to be, you are reading the vacuum line, not the thing you are actually supposed to be measuring which is the lines themselves. Use only (1) vacuum line on one valve and mount the micron to the other, this gives you the furthest point and precise correct measurement.

  • @mikegeorge6893
    @mikegeorge6893 ปีที่แล้ว +1

    If you go to a piston you can save even more money an it won't break 🎉

  • @Samlol23_drrich
    @Samlol23_drrich ปีที่แล้ว

    Great job. 10/10. Except you didnt flow nitrogen.........

  • @jamesongbueco104
    @jamesongbueco104 ปีที่แล้ว

    stupid size of copper on lowside

  • @jman0870
    @jman0870 11 หลายเดือนก่อน

    Wrong tools at every turn (12” adjustable for that little liquid valve cap and pump pliers marring up the brass nut on the TXV???), burnt the shit out of the sheet metal touching cabinet insulation, never turned air handler power off, “trapped refrigerant in the compressor (try outdoor/condenser coil),” “the compressor protection” will stop the compressor when you’re literally HOLDING IN THE CONTACTOR, and no filter drier change? You get an A+ for hack job. There is a reason why the other company quoted $2200. The charge needed pulled to change the drier and the condenser is on a roof. That is not a high price for a TXV replacement. It’s AVERAGE. 🤣🤣🤣

    • @ApartmentMaintenancePro
      @ApartmentMaintenancePro  11 หลายเดือนก่อน

      I'm sure my repair will last a decade or more like they always do but thanks for the input

    • @jman0870
      @jman0870 11 หลายเดือนก่อน

      @@ApartmentMaintenancePro that logic is ridiculous. That’s like saying cross threading a bolt is fine as long as it doesn’t fall out 🤣🤣🤣

    • @sawdust85222
      @sawdust85222 10 หลายเดือนก่อน

      ​@@jman0870Where are your videos showing how to properly do this?

    • @jman0870
      @jman0870 10 หลายเดือนก่อน

      @@sawdust85222 oh my bad. You need a video to show you how to use tools at an apprentice level? I’ll get right on that.

    • @repairitdontwreckit4257
      @repairitdontwreckit4257 12 วันที่ผ่านมา

      I thought your work was just fine. You gave advice to visit other legitimate Utubers who I visit all the time. At the end of the video you explained your position and reasoning for your actions. As a retired service plumber I totally understand that each client you work for has a budget and level of condition they want to maintain their buildings at. From what I gather another company diagnosed the problem.I’m assuming they got paid for their work. They didn’t get the replacement job though. It would be nice to get every job you quote. That doesn’t happen in a competitive market. Your video depicted what it is like to do your type of job. Thanks