5:11 - Thanks for the idea. The only thing I will change from your method if I need to use it is use a bottoming tap instead of the one you show here. I am new to refrigeration so your videos are effective educational tools for me!
This is genius! I would never thought of this. If bulb loose charge, you can make artificial opening force with the bolt. Will come in handy on emergency situation.
Thats genius level work there! Had TXV fail shut so I could not pump the system down to replace it, so cut the sensing bulb off and made a connection to the capillary and used nitrogen to pressurise the bellows and open the valve.
Regular soft solder will stick to stainless if you use a soldering iron and flux. If you use a torch, the instant the flame hits the stainless it will oxidize and the solder wont stick.
Sir am felix jr. Can you make a cooled storage diagram system procedure. I want to make a storage 20 footer van in my place thanks you are genius good blessed you sir.
Great video and thank you for the content. Interesting, it's interesting that you have valuable cargo but not critical spare items to keep the valuable cargo in good condition.
Leckyjake can u make a stepbystep vlog on pumping down reefer and filling of refrigerant pls. We dont have electrician onboard. This would help us alot. Thanks for those really helpful and important videos. More power Lexkyjake
Should be able to front seat the king valve. And have your manifold gauge hook up to the low side to see the pressure or if the unit has a display that shows data and lock it on suction pressure.. once the king valve is closed. The unit will start going into a vacuum.. storing all refrigerant in the receiver tank. Once suction hits 0. Shut off the unit... it is now pumped down. And you can repair on low side lines or do repairs or remove compressor. Once unit is repair. U can front seat the discharge valve. And RR filter drier. And pull a vacumm @-29/30. Then can charge accordingly, utilizing the vacuum that's held in the system to pull the refrigerant in... once charge, back seat the king valve. Start unit. Purge the king charge line into lowside for acouple seconds... that line is now good to be taken off.. them back seat low side valve... unit is now in normal op. Hope that helps
We repair a lot of different types of reefer units and I’ve learned to salvage as many used parts as I can because sometimes you can’t get the new parts on time.
That’s a good workaround for emergencies! Shame they’re not TEVs with removable power heads as you could keep a pre-made emergency power head on standby without having to unsweat 👍🏻 top video
5:11 - Thank you for your input. You just made this artificial sensing bulb idea even more valuable to me (see my comment above)! I still have two Sporlan valves that were replaced recently (one was a capillary tube rub out so the valve is likely still good), which I will modify to keep on hand.
Nakakasawa din pagbabarko lek. I only have 4 yrs international experience as ETO. then 1 year sa shipyard in batam indonesia and the challenge was intense kung shipyard vess commissioning. At 28 yrs old i retired as ETO and naging flagstate surveyor dto sa Pinas, also im an ISM Auditor. i keep watching your videos because it brings back my memories at sea. Now im on a campaign to help develop our local shipping to something better like what i saw in other countries like indonesia, that some how our local ships would be at the same standards and quality like an international ocean vessels.
Yes TXV is a TXV but depends on where you work .. his containers stay shut I assume so there isn’t much fluctuations in heat load so as long as he has a good superheat it’s ok but if you’re in a busy restaurant walk in there could be risk.. but in a pinch this is very good sometimes you get a late night call or SupplyHouse is hours away
Wow ngayon ko lang nalaman na pwede pala i override yang expansion valve dati akong maintenance ng supermarket di ko din naranasan na mag override ng ganyan kasi kung me problema nakakatakbo naman ako agad sa mga shop bagay yan kung nasa remote area malaking tulong
my dad works at your company as an OS. I recently passed my REE licensure examination. I'm looking forward to work in your company as well and work with you 🙏🏼
Hi @leckyjake Can you show me how to install the air supply sensor in a Daikin reefer container, the additional sensor wires are in the electrical box of the reefer container but I don't know how to wire it .
Hi my friend Leckyjake, I'm speaking from Brazil, I'm trying to find out about the Alj281 from the Daikin container.. Other than the SMV valve, the SMV coil, and the solenoid coils, what else can cause this alarm?
Good day Sir. I just want to ask something. I have an upright freezer that I wanted to make the freezing faster. Can I use the TXV, to modify the speed of running refregerant. Thanks in advance for any info.
As he stated it’s for emergency repair only. And you have to remember this is a cargo ship and those containers stay shut during shipping so I don’t think there would be changes in heat load. As long as there’s is good amount of SH back to compressor is fine. Also I’m sure it’s better to try this and save $300,000+ worth of product than $5000-$12,000 compressor
5:11 - Thanks for the idea. The only thing I will change from your method if I need to use it is use a bottoming tap instead of the one you show here. I am new to refrigeration so your videos are effective educational tools for me!
This is genius! I would never thought of this. If bulb loose charge, you can make artificial opening force with the bolt. Will come in handy on emergency situation.
You are smart man. I would never have believed that would work
Thank you for the knowledge, success for "leckyjake ....." ... Pekalongan, Central Java, Indonesia attended
Thats genius level work there!
Had TXV fail shut so I could not pump the system down to replace it, so cut the sensing bulb off and made a connection to the capillary and used nitrogen to pressurise the bellows and open the valve.
Hey I’ve done that too but would you be able to use like 45% solder on that stainless steel line?
Regular soft solder will stick to stainless if you use a soldering iron and flux. If you use a torch, the instant the flame hits the stainless it will oxidize and the solder wont stick.
@@EldonJohansen 15% silver solder solders stainless steel perfectly. Give it a go
@@edwardtsang3243 it sort of works but the phosphorus in the rod makes a brittle intermetallic bond with the iron.
So it will work as a Fixed Metering Device. Awesome!!!
Sir am felix jr. Can you make a cooled storage diagram system procedure. I want to make a storage 20 footer van in my place thanks you are genius good blessed you sir.
Great videos..
Keep them coming ..
Steve Sheffield UK ..
Keep up the good work my brother
Good solution to this problem !
Good knowledge my bro.. thanks 👍
Great video and thank you for the content. Interesting, it's interesting that you have valuable cargo but not critical spare items to keep the valuable cargo in good condition.
Leckyjake can u make a stepbystep vlog on pumping down reefer and filling of refrigerant pls. We dont have electrician onboard. This would help us alot. Thanks for those really helpful and important videos. More power Lexkyjake
Should be able to front seat the king valve. And have your manifold gauge hook up to the low side to see the pressure or if the unit has a display that shows data and lock it on suction pressure.. once the king valve is closed. The unit will start going into a vacuum.. storing all refrigerant in the receiver tank. Once suction hits 0. Shut off the unit... it is now pumped down. And you can repair on low side lines or do repairs or remove compressor. Once unit is repair. U can front seat the discharge valve. And RR filter drier. And pull a vacumm @-29/30. Then can charge accordingly, utilizing the vacuum that's held in the system to pull the refrigerant in... once charge, back seat the king valve. Start unit. Purge the king charge line into lowside for acouple seconds... that line is now good to be taken off.. them back seat low side valve... unit is now in normal op. Hope that helps
Nice. Turns it into a piston. Probably have to baby it though but good in a pinch
We repair a lot of different types of reefer units and I’ve learned to salvage as many used parts as I can because sometimes you can’t get the new parts on time.
informative video good job lodi
Really, it's a great idea....
I am also working in hvac any job are there so inform
What a great idear in a emergency.
Good as usual!
Simple and clear.
That’s a good workaround for emergencies! Shame they’re not TEVs with removable power heads as you could keep a pre-made emergency power head on standby without having to unsweat 👍🏻 top video
There ARE more in refrigeration application's
5:11 - Thank you for your input. You just made this artificial sensing bulb idea even more valuable to me (see my comment above)! I still have two Sporlan valves that were replaced recently (one was a capillary tube rub out so the valve is likely still good), which I will modify to keep on hand.
It's really rare that a Danfoss TU goes bad. But this trick i have never seen. Being in this trade for 10 years.
Hahaha the first answer I said was the same thing tap and set screw.
Best is TXV with manual set screw for emergency
But great video
Keep inspiring and sharing your knowledge , your videos provide confidence to cadets
Wow! Getting the thing to work at any, learnt something. Thanks.
Wow! It's a amazing idea. 👍
Nakakasawa din pagbabarko lek. I only have 4 yrs international experience as ETO. then 1 year sa shipyard in batam indonesia and the challenge was intense kung shipyard vess commissioning. At 28 yrs old i retired as ETO and naging flagstate surveyor dto sa Pinas, also im an ISM Auditor. i keep watching your videos because it brings back my memories at sea. Now im on a campaign to help develop our local shipping to something better like what i saw in other countries like indonesia, that some how our local ships would be at the same standards and quality like an international ocean vessels.
I had similar issue with our ECR AC, now i know what to do 🤘 Kudos to u brother!
Very cool! Just make sure that if you put a stainless bolt into stainless use some antisieze. Stainless into stainless galls horribly.
Very good work
Nice solution bro
Very cool boss , god bless you👌
Galing nyo talaga Sir
I have heard of people braising a port onto the TXVN, putting in high-pressure nitrogen
Great demo Bro. keep going. Thank you
Great video. I may use this in my job one day. My job is on land, but a TXV is a TXV on land or sea
Yes TXV is a TXV but depends on where you work .. his containers stay shut I assume so there isn’t much fluctuations in heat load so as long as he has a good superheat it’s ok but if you’re in a busy restaurant walk in there could be risk.. but in a pinch this is very good sometimes you get a late night call or SupplyHouse is hours away
Wow what a great way to solve refrigeration problem
Thank you for watching
good day sir..lagi aq nanunuod ng vlog m at marami p aq natutunan,,ty
Really helpful video
thank
you
The bolt reminds me of a analog compressor unloader. Nice hack to keep in the tool bag.
thank you for sharing Sir Jake. God bless you!
I'm Angolan I like you very much
Thank you for teach me
Great idea 👍
Nice ,very informative
Wow ngayon ko lang nalaman na pwede pala i override yang expansion valve dati akong maintenance ng supermarket di ko din naranasan na mag override ng ganyan kasi kung me problema nakakatakbo naman ako agad sa mga shop bagay yan kung nasa remote area malaking tulong
learn a new trick every day. the more you know the more confident you are.
Some reefers are located too much height, are u monitoring those
nice job sir
Wow next Level Thank you I need this
Galing pare!
I’m also a refer tech 32 yrs San Antonio Texas.
my dad works at your company as an OS. I recently passed my REE licensure examination. I'm looking forward to work in your company as well and work with you 🙏🏼
thanks for sharing your knowledge sir...🙏
Thank you for your continuous support
this is good to know. Thanks Jake
Nice vedio thanks for sharing...
Muito obrigado, tank you.
Hi @leckyjake
Can you show me how to install the air supply sensor in a Daikin reefer container, the additional sensor wires are in the electrical box of the reefer container but I don't know how to wire it .
This is high level video hahaha Thank you to share this knowledge
Sir your video ❤️❤️❤️❤️ I get alot of knowledge
you can't imagine how emergency situations may be handled cleverly onboard.
Thx, from Romania!!!
Many thanks!! Useful information
how about a stuck open expansion valve?
Hi my friend Leckyjake, I'm speaking from Brazil, I'm trying to find out about the Alj281 from the Daikin container.. Other than the SMV valve, the SMV coil, and the solenoid coils, what else can cause this alarm?
Good idea...
What about night, you have to readjust the sub cooling?
You sir are a GENIUS
Thank you my friend I like so much
God bless you 🙏
that is a very streesfull work..
Very nice sir😊
Can you find an empty refer and check to see if it’s the right one and rob it from the empty container?
They usually put the empty containers on the top so it’s a bit problem to extract the txv from 5 or 6 hight
How deep did you put that bolt to press the diaphragm? 🤔
Depends om the amount of opening needed for your setpoint
@@leckyjake you mean superheat
Very good info.
But why u walk every day.? Pls use iot . Put sensors and connect with cloud and get full 24x7 data on your mobile phone.
Secondly and firzt viewed po sir...👏🕊👍
Informazyuniz tiknikz po, txv subject nyu rin po pla anuh...
Thank you
Step one. Don’t use junk danfoss valves. Install a sporlan. Buy rebuild kits and screens. Repair made. Good tip though.
Do u stock spare Compressors onboard?
Good day Sir. I just want to ask something. I have an upright freezer that I wanted to make the freezing faster. Can I use the TXV, to modify the speed of running refregerant. Thanks in advance for any info.
nope. txv is always the last thing that you need to touch on your refrigeration system. you may add cooling to your condenser.
Pretty super ways and thanks
Sir how to identify that your txv is defective? Tank you sir...
Sana ol sir maparaan pag dating sa trabaho
I'm from the EPA and I saw what you did!
May be deminimus?. Lol
thanks
Thank you so much ur knowledge share me friend
Isa kang henyo lecky💯👍
Awesome!
hi may i know wht kind of refrigerant inside the thermostatic expansion valve...
Thank you Sir. 🙏
Sir,How will you know that you should adjust the diaphragm opening? Is it based on temperature?
In my opinion he adjust based on temperature but it is extremely delicate
Evaporator superheat and Compressor superheat
No way that screw was M4. Great video though!
He already said the drilling bit was M4, so has to be at least m5 and more looking like M6. Great video though
You are super great
У нас говорят "голь на выдумку хитра" 👍
thanx sir so useful
I guess it would work just like if you replaced the TXV with a piston.
Can you so me what is the temperature of that cantenor.Sir
Refrigeration mechanic can also do this job too?
Thank you soo much ....😊
What a very cool idea! Did the company put you through a refrigeration school as well?
Thank you very much.
+John Cantrell Refrigeration basic and troubleshooting was already there in his major I guess.
@@Neo-po2xw Carrier does reefer classes for certification. It will cost you couple hundred bucks though
it's only temporary unless it works
Does it possible to adjust this
Its a little dangerous as the flow through TVX may become uncontrolled and damage the compressor(s)!
As he stated it’s for emergency repair only. And you have to remember this is a cargo ship and those containers stay shut during shipping so I don’t think there would be changes in heat load. As long as there’s is good amount of SH back to compressor is fine.
Also I’m sure it’s better to try this and save $300,000+ worth of product than $5000-$12,000 compressor
Oooh think mcfly
Big fan sir