I don't understand what you actually mean but if you want to know plates pattern and flow , I will share photos from instruction on my community post. Please check on it. Thanks!
You have to insert blind plate to the S.W feeding to the evaporator side or close the valve for it (if provided) to prevent S.W overflowing from evaporator. Then, open S.W in/out valves for condenser and run S.W pump. Check whether S.W leaks from condenser.
sir, good day. may i ask you a question pls? why there is an orifice in fwg feed line? we already have a feed valve to control/adjust the feed inlet. so why in addition we need an orifice?
Good day too. I answer your question as follow. It is not my opinion. They are from maker's manual. Orifice is for optimum flow rate to the evaporator side. Calulated by maker. 1) If you remove the orifice ,feed water flow rate will high and evaporation will reduce. 2) If orifice is too small or clogging, Less water will enter into the evaporator plates and salt will accumulate very quick. Feed water regulating valve is barely adjustable. You should not adjust it without proper reason. Some type of fresh water generator has no regulating valve. They just install Orifice. So, regulating valve is not a must-have item, but the orifice is. Thanks
Hi Htoon Pyeat
thanks for your useful video.
I could not understand the stream of flow through plates.
are there any clear references I can use?
I don't understand what you actually mean but if you want to know plates pattern and flow , I will share photos from instruction on my community post. Please check on it. Thanks!
3:27 rubber gasket is opposite? Suppose to be jacket inlet is open to jacket out right?
Rubber gasket is closed and sealed for in and out . Seawater side is open in the top for water vapour in.
Sir , if condenser section is open for cleaning and after assembling how to test it for leakage?
You have to insert blind plate to the S.W feeding to the evaporator side or close the valve for it (if provided) to prevent S.W overflowing from evaporator. Then, open S.W in/out valves for condenser and run S.W pump. Check whether S.W leaks from condenser.
sir, good day.
may i ask you a question pls?
why there is an orifice in fwg feed line? we already have a feed valve to control/adjust the feed inlet. so why in addition we need an orifice?
Good day too. I answer your question as follow. It is not my opinion. They are from maker's manual.
Orifice is for optimum flow rate to the evaporator side. Calulated by maker.
1) If you remove the orifice ,feed water flow rate will high and evaporation will reduce.
2) If orifice is too small or clogging, Less water will enter into the evaporator plates and salt will accumulate very quick.
Feed water regulating valve is barely adjustable. You should not adjust it without proper reason. Some type of fresh water generator has no regulating valve. They just install Orifice. So, regulating valve is not a must-have item, but the orifice is. Thanks
ကြောက်ကြောက်
ဒီတခါ ပလိတ် အသစ်နဲ့ တချီတည်း ပြီးသွားပါပြီ... ဘုရားတော့ တ လိုက်ရတယ် 😁
@@HtoonPyeat congratulations ပါ
Cleaninig Chemical name
General name is Descaling chemical (brand... Care Clean Descalex HD)