The pin gets poked in fingers while removing and I was searching for tips, eventually landed with your video. You trick to remove needle is much Appreciated. Thanks buddy :-)
NEVER pierce the tip, center of your finger! That hasn't been taught for nearly 20 year. The majority of nerve endings are inside center of finger pad. ALWAYS Lance the SIDE of the fingers, or thumb. Doing it that way, will remove approximately 40% - 60% of the pain you used to feel. (use new needles for even less pain.) Y'all have a beautiful weekend. ✅
Thanks for posting this as I just got a new pen and the instructions for it are pretty badly shown. Your video was easy to follow, and I had been afraid of breaking the device by forcing it. Again, thanks for the tutorial video.
The Accu-Chek Soft Clix is a dangerous bio-weapon. The lancet ejection/disposal procedure is liken to ejecting a contaminated dart at anyone around you ! You should use the twisted off lancet top cap to cover the tip of the lancet before ejecting. Accu-Chek shows that you need to eject the lancet into a "Sharps Container" like no one has that at home !
Hi E Tow, Thanks for writing! Agreed with your comments on twist cap and use of Sharps bin. The actual intent of making this video was to address a practical scenario. Most often users tend to forget removing lancet after test and few wish to reuse couple of times more. In these cases the twist cap is lost. Having said this in many occasions user either poke fingers or break the device itself while removing device top cover. Keeping this in mind the video shows a safe practice to hold top cover with both thumbs while uninstalling. Also the video shows to pull down ejector thus keeping lancet facing downwards so it doesn’t take a flight. Tried to address pain points from personal experience which felt could help other users.
Hi Alex, Can you please check if rotating cap and setting needle penetration depth to higher value helps. If the cap mechanism is broken then it will be difficult to fix. You need to get a new lancing device.
Hi Ravi, with every use the needle lose sharpness so if you are sensitive to pain then can hurt. If there is no skin or blood infection then can decide to use needle couple of times more provided the needle is used in a very sterile conditions. Please note as per user instructions it is recommended to use needle once.
Hi Premlata, The Accu Chek pin cannot be used in Dr Trust lancing device. But you can buy 'Accu Chek Softclix' lancing device separate for lancing purpose and use Dr Trust Glucometer for sugar measurement.
Hello sir i just used one for my father.....and after using it for my father i was curious to know about mine....and there were shortage of Needles so i used the same needle which i had used for my father.... will it be any problem??? I'm so worried please reply....and ya before using i cleaned the needle with water..??
Hi Shankar, I hope your father doesn’t have any skin or blood infection, until then it’s safe. Always use a new, sterile needle and never share. Keep in mind that cleaning by any means does not make re-using the needle risk-free.
Hi Arun, I hope that person doesn’t have any skin or blood infection, until then it’s safe. To keep yourself safe from poking next time pls follow practice shown in video - hold top cover with both thumbs while uninstalling and pull down ejector thus keeping needle facing downwards so it doesn’t take a flight.
Sorry to say that... You haven't explained, what are 1,2,3,4 numbers on the softclix...! Which number indicates higher depth & which number indicates lower depth...? Please try to explain...!
Hi Raghuram, Sry to miss this section. The Softclix device offers 11 penetration depth options. The penetration depth is 0.8 mm at the first setting and increases by 0.15 mm with each setting. The settings are shown on the cap by the numbers 1 to 5 with additional levels marked with dots to enable you to precisely adjust to your individual skin type. Select the first setting, 0.5, for the smallest depth of penetration, and the last setting, 5.5, for the greatest depth of penetration. Select 0.5 to 1.5 for softer-than-average skin, 2 to 3.5 for average skin, and 4 to 5.5 for harder-than-average or calloused skin. Setting 0.5 - 0.80 Penetration Depth (mm) Setting 1 - 0.95 Penetration Depth (mm) Setting 1.5 - 1.10 Penetration Depth (mm) Setting 2 - 1.25 Penetration Depth (mm) Setting 2.5 - 1.40 Penetration Depth (mm) Setting 3 - 1.55 Penetration Depth (mm) Setting 3.5 - 1.70 Penetration Depth (mm) Setting 4 - 1.85 Penetration Depth (mm) Setting 4.5 - 2.0 Penetration Depth (mm) Setting 5 - 2.15 Penetration Depth (mm) Setting 5.5 - 2.30 Penetration Depth (mm)
Hi, There seems to be an slip between cam and ratchet mechanism and causing no loading. Sorry to say if you try to open and fix then probably not able to put back again due to factory assembly. Also for this device there is no spare or service availability.
Hi Shazia, I hope your mom doesn’t have any skin or blood infection, until then it’s safe. To keep yourself safe from poking next time pls follow practice shown in video - hold top cover with both thumbs while uninstalling and pull down ejector thus keeping needle facing downwards so it doesn’t take a flight.
Hi, Looks like there is a mechanism failure. Can you please try installing lancet pin one more time and redo rotating cap. If nothing works then you may need to replace lancet device as there is no service options available for the device.
Hi, Sorry.. will soon upload subtitles. For your quick understanding for time being: At 00:42 - Press the plunger. At 000:52 - Press the yellow button. If you have any other questions at any part of the video please do let me know.
Dear Viewers, Writing results is no more required. Learn how to save memory - th-cam.com/video/eWPMnXyY8hk/w-d-xo.html
The pin gets poked in fingers while removing and I was searching for tips, eventually landed with your video. You trick to remove needle is much Appreciated. Thanks buddy :-)
Hi Shilpa, Glad it helped 👍
Thank You !
NEVER pierce the tip, center of your finger!
That hasn't been taught for nearly 20 year. The majority of nerve endings are inside center of finger pad. ALWAYS Lance the SIDE of the fingers, or thumb. Doing it that way, will remove approximately 40% - 60% of the pain you used to feel.
(use new needles for even less pain.)
Y'all have a beautiful weekend. ✅
Thanks a lot for sharing this piece of information. This definitely helps viewers.
Appreciate all the time you took for this demo 3 years back. It helped me a lot 😊
Hi, Great to hear and happy to help :-)
Cheers!
Thankyou so much.I was having a tough time figuring out how to pierce.This video was so helpful.
Hi Sruthi, Glad to hear the video was helpful :-)
Thanks for posting this as I just got a new pen and the instructions for it are pretty badly shown. Your video was easy to follow, and I had been afraid of breaking the device by forcing it. Again, thanks for the tutorial video.
Hi James, Thanks a lot for posting a note of appreciation.
Glad to know the video helped!
thank you! I was having a heck of a time removing the lancet lol
Hi, Glad the video helped :-)
Grrr! I keep waisting strips and can't remember how to remove the Lancet.
Good demo, quick n sweet
Thank you very much for sharing this information.❤️
Hey Harry, Glad the video was helpful :-)
Cheers!
Thank you for this very helpful video.
Glad it was helpful! 👍😊
Thank you for the information ☺️.
Hi Subhranil, My pleasure 😊
This was so helpful.... 👍🏻
Glad it was helpful!
Thanks for your comment.
Useful tips thanks
So nice of you :-)
Thank you.
You're welcome my friend!
Cheers :-)
Helpful
Hi Jamal, Glad to hear that.
Thanks a Lot Bro
Hi Shivas, Glad the video was helpful.
Thank you!
Hey Janet, You're welcome! :-)
Thanks for sharing
Hi Geeta, Thanks for watching!
Thank u sir
Great to know video was useful.
Happy to help :-)
Thank you
Hi Runa, Glad to know video was helpful. Cheers :-)
Thanks
You are welcome!
Glad the video was helpful :-)
The Accu-Chek Soft Clix is a dangerous bio-weapon. The lancet ejection/disposal procedure is liken to ejecting a contaminated dart at anyone around you ! You should use the twisted off lancet top cap to cover the tip of the lancet before ejecting. Accu-Chek shows that you need to eject the lancet into a "Sharps Container" like no one has that at home !
Hi E Tow, Thanks for writing! Agreed with your comments on twist cap and use of Sharps bin.
The actual intent of making this video was to address a practical scenario. Most often users tend to forget removing lancet after test and few wish to reuse couple of times more. In these cases the twist cap is lost. Having said this in many occasions user either poke fingers or break the device itself while removing device top cover. Keeping this in mind the video shows a safe practice to hold top cover with both thumbs while uninstalling. Also the video shows to pull down ejector thus keeping lancet facing downwards so it doesn’t take a flight.
Tried to address pain points from personal experience which felt could help other users.
Good
Hi, Glad video was helpful!
i think it would be great to begin with how to remove the existing pin and follow with how to put a new one.
Hi Anand, Great comment, will keep this in mind. Thank you!
Actually this video was made in the intention of helping new users.
Can it be used with Microlet lances ?
Hi Biswarup, sorry... the Microlet lancets cannot be used in Accu Chek Softclix.
TQ sir
You are welcome 😊👍
Sir my device is not puncturing skin properly it is not going much deep . Can we fix it.
Hi Alex, Can you please check if rotating cap and setting needle penetration depth to higher value helps.
If the cap mechanism is broken then it will be difficult to fix. You need to get a new lancing device.
please fix in point 4,
in hospitals they generally keep in 4 point to go into the skin
One needs ko kitni bar use kar sakte hai
Hi Ravi, with every use the needle lose sharpness so if you are sensitive to pain then can hurt. If there is no skin or blood infection then can decide to use needle couple of times more provided the needle is used in a very sterile conditions. Please note as per user instructions it is recommended to use needle once.
Kya ye lancet Dr trust me use nahi kar sakte
Hi Premlata, The Accu Chek pin cannot be used in Dr Trust lancing device.
But you can buy 'Accu Chek Softclix' lancing device separate for lancing purpose and use Dr Trust Glucometer for sugar measurement.
Hello sir i just used one for my father.....and after using it for my father i was curious to know about mine....and there were shortage of Needles so i used the same needle which i had used for my father.... will it be any problem??? I'm so worried please reply....and ya before using i cleaned the needle with water..??
Hi Shankar, I hope your father doesn’t have any skin or blood infection, until then it’s safe. Always use a new, sterile needle and never share. Keep in mind that cleaning by any means does not make re-using the needle risk-free.
It's very risky for spreading disease, please use a new Lancet.
I pricked in to my finger after two hours of check a persion suger level...can I get hiv on this way
Hi Arun, I hope that person doesn’t have any skin or blood infection, until then it’s safe.
To keep yourself safe from poking next time pls follow practice shown in video - hold top cover with both thumbs while uninstalling and pull down ejector thus keeping needle facing downwards so it doesn’t take a flight.
How many time I can use one lancet (niddle)
Hi SKR, The needles are for single use. These will loose sharpness after each use and may cause pain over repeated use.
Sorry to say that... You haven't explained, what are 1,2,3,4 numbers on the softclix...! Which number indicates higher depth & which number indicates lower depth...? Please try to explain...!
Hi Raghuram, Sry to miss this section.
The Softclix device offers 11 penetration depth options. The penetration depth is 0.8 mm at the first setting and increases by 0.15 mm with each setting. The settings are shown on the cap by the numbers 1 to 5 with additional levels marked with dots to enable you to precisely adjust to your individual skin type.
Select the first setting, 0.5, for the smallest depth of penetration, and the last setting, 5.5, for the greatest depth of penetration. Select 0.5 to 1.5 for softer-than-average skin, 2 to 3.5 for average skin, and 4 to 5.5 for harder-than-average or calloused skin.
Setting 0.5 - 0.80 Penetration Depth (mm)
Setting 1 - 0.95 Penetration Depth (mm)
Setting 1.5 - 1.10 Penetration Depth (mm)
Setting 2 - 1.25 Penetration Depth (mm)
Setting 2.5 - 1.40 Penetration Depth (mm)
Setting 3 - 1.55 Penetration Depth (mm)
Setting 3.5 - 1.70 Penetration Depth (mm)
Setting 4 - 1.85 Penetration Depth (mm)
Setting 4.5 - 2.0 Penetration Depth (mm)
Setting 5 - 2.15 Penetration Depth (mm)
Setting 5.5 - 2.30 Penetration Depth (mm)
@@bicyclecolours8988 Good explanation...!Thank you for immediate response..! You please edit your video attaching the superscribed info...!
Is it disposable??
Hi Diya, the lancet needle is disposable and pen is reusable.
Good needles were from different company
Hi, You need to use the same brand Accu Chek to use in this device.
There is some issue with my lancet device... Its not loading even when i press it... Any idea how to make it work?
Hi, There seems to be an slip between cam and ratchet mechanism and causing no loading. Sorry to say if you try to open and fix then probably not able to put back again due to factory assembly. Also for this device there is no spare or service availability.
@@bicyclecolours8988 okay thanks
I m using this for my mom.. when i was remove the niidle ...wo mere chub gyi dhoke se... koi problem to nahi hogi..plz reply
Hi Shazia, I hope your mom doesn’t have any skin or blood infection, until then it’s safe.
To keep yourself safe from poking next time pls follow practice shown in video - hold top cover with both thumbs while uninstalling and pull down ejector thus keeping needle facing downwards so it doesn’t take a flight.
@@bicyclecolours8988 thanxx alot🙂
0:33 i heared the click sound but when i rotate it, the upper part will pop out..
Pls help me..
Hi, Looks like there is a mechanism failure. Can you please try installing lancet pin one more time and redo rotating cap. If nothing works then you may need to replace lancet device as there is no service options available for the device.
@@bicyclecolours8988 thank you
I'm sorry but we're you saying press the aluminum? I'm so confused. 🤔
Hi, Sorry.. will soon upload subtitles.
For your quick understanding for time being:
At 00:42 - Press the plunger.
At 000:52 - Press the yellow button.
If you have any other questions at any part of the video please do let me know.
@@bicyclecolours8988 Thank you!!! 😊
Can I preloadire than 1 lancet at a time?
Hi Jay, This device is only capable of having only one lancet at a time.
@@bicyclecolours8988 hmm so is it the Fastclix that lets you load more than one?
Hi Jay, Yes, Fastclix has a drum with 6 preloaded lancets.
@@bicyclecolours8988 thanks gotcha
I'll just keep using my older True Metrix needle pin, I still have 4 boxes of needles
Hi Gabriel, The needles are for single use. These will loose sharpness after each use and may cause pain over repeated use.
Thanks