    @bicyclecolours8988  3 ปีที่แล้ว +2

    Dear Viewers, Writing results is no more required. Learn how to save memory - th-cam.com/video/eWPMnXyY8hk/w-d-xo.html

  • @shilpasaha5494
    @shilpasaha5494 3 ปีที่แล้ว +14

    The pin gets poked in fingers while removing and I was searching for tips, eventually landed with your video. You trick to remove needle is much Appreciated. Thanks buddy :-)

  • @mddell58
    @mddell58 2 ปีที่แล้ว +13

    NEVER pierce the tip, center of your finger!
    That hasn't been taught for nearly 20 year. The majority of nerve endings are inside center of finger pad. ALWAYS Lance the SIDE of the fingers, or thumb. Doing it that way, will remove approximately 40% - 60% of the pain you used to feel.
    (use new needles for even less pain.)
    Y'all have a beautiful weekend. ✅

    • @bicyclecolours8988
      @bicyclecolours8988  2 ปีที่แล้ว +2

      Thanks a lot for sharing this piece of information. This definitely helps viewers.

  • @bhramosss7604
    @bhramosss7604 6 หลายเดือนก่อน

    Appreciate all the time you took for this demo 3 years back. It helped me a lot 😊

    • @bicyclecolours8988
      @bicyclecolours8988  6 หลายเดือนก่อน +1

      Hi, Great to hear and happy to help :-)
      Cheers!

  • @sruthin9469
    @sruthin9469 ปีที่แล้ว +1

    Thankyou so much.I was having a tough time figuring out how to pierce.This video was so helpful.

  • @a1930ford
    @a1930ford 2 ปีที่แล้ว +2

    Thanks for posting this as I just got a new pen and the instructions for it are pretty badly shown. Your video was easy to follow, and I had been afraid of breaking the device by forcing it. Again, thanks for the tutorial video.

    • @bicyclecolours8988
      @bicyclecolours8988  2 ปีที่แล้ว

      Hi James, Thanks a lot for posting a note of appreciation.
      Glad to know the video helped!

  • @shiningstarsoup
    @shiningstarsoup 2 ปีที่แล้ว +4

    thank you! I was having a heck of a time removing the lancet lol

    • @bicyclecolours8988
      @bicyclecolours8988  2 ปีที่แล้ว

      Hi, Glad the video helped :-)

    • @MoonlightNothing
      @MoonlightNothing 11 หลายเดือนก่อน

      Grrr! I keep waisting strips and can't remember how to remove the Lancet.

  • @kasthuriprp8078
    @kasthuriprp8078 3 ปีที่แล้ว +3

    Good demo, quick n sweet

  • @harrysonabbimalik9757
    @harrysonabbimalik9757 10 หลายเดือนก่อน +1

    Thank you very much for sharing this information.❤️

    • @bicyclecolours8988
      @bicyclecolours8988  10 หลายเดือนก่อน

      Hey Harry, Glad the video was helpful :-)
      Cheers!

  • @jenniferbibb4068
    @jenniferbibb4068 2 ปีที่แล้ว +3

    Thank you for this very helpful video.

  • @subhranildas2702
    @subhranildas2702 3 หลายเดือนก่อน +1

    Thank you for the information ☺️.

  • @NehaG.
    @NehaG. 2 ปีที่แล้ว +2

    This was so helpful.... 👍🏻

  • @deneshanden4901
    @deneshanden4901 2 ปีที่แล้ว +2

    Useful tips thanks

  • @พันธุ์ศักดิ์ศิริเลิศ
    @พันธุ์ศักดิ์ศิริเลิศ หลายเดือนก่อน +1

    Thank you.

  • @jamalparakandi172
    @jamalparakandi172 หลายเดือนก่อน +1

    Helpful

  • @shivaskenue3447
    @shivaskenue3447 9 หลายเดือนก่อน +1

    Thanks a Lot Bro

    • @bicyclecolours8988
      @bicyclecolours8988  9 หลายเดือนก่อน

      Hi Shivas, Glad the video was helpful.

  • @janets2041
    @janets2041 ปีที่แล้ว +1

    Thank you!

  • @geetacherodian2184
    @geetacherodian2184 3 ปีที่แล้ว +2

    Thanks for sharing

  • @zaibunnisakhan7697
    @zaibunnisakhan7697 ปีที่แล้ว +1

    Thank u sir

  • @runalaila4353
    @runalaila4353 ปีที่แล้ว +1

    Thank you

    • @bicyclecolours8988
      @bicyclecolours8988  ปีที่แล้ว

      Hi Runa, Glad to know video was helpful. Cheers :-)

  • @esteffso
    @esteffso ปีที่แล้ว +1

    Thanks

  • @etow8034
    @etow8034 3 ปีที่แล้ว +3

    The Accu-Chek Soft Clix is a dangerous bio-weapon. The lancet ejection/disposal procedure is liken to ejecting a contaminated dart at anyone around you ! You should use the twisted off lancet top cap to cover the tip of the lancet before ejecting. Accu-Chek shows that you need to eject the lancet into a "Sharps Container" like no one has that at home !

    • @bicyclecolours8988
      @bicyclecolours8988  3 ปีที่แล้ว +1

      Hi E Tow, Thanks for writing! Agreed with your comments on twist cap and use of Sharps bin.
      The actual intent of making this video was to address a practical scenario. Most often users tend to forget removing lancet after test and few wish to reuse couple of times more. In these cases the twist cap is lost. Having said this in many occasions user either poke fingers or break the device itself while removing device top cover. Keeping this in mind the video shows a safe practice to hold top cover with both thumbs while uninstalling. Also the video shows to pull down ejector thus keeping lancet facing downwards so it doesn’t take a flight.
      Tried to address pain points from personal experience which felt could help other users.

  • @fabulousphoties
    @fabulousphoties ปีที่แล้ว +1

    Good

  • @reachanand438
    @reachanand438 2 วันที่ผ่านมา

    i think it would be great to begin with how to remove the existing pin and follow with how to put a new one.

    • @bicyclecolours8988
      @bicyclecolours8988  วันที่ผ่านมา

      Hi Anand, Great comment, will keep this in mind. Thank you!
      Actually this video was made in the intention of helping new users.

  • @biswarupbhattacharya2988
    @biswarupbhattacharya2988 2 ปีที่แล้ว

    Can it be used with Microlet lances ?

    • @bicyclecolours8988
      @bicyclecolours8988  2 ปีที่แล้ว

      Hi Biswarup, sorry... the Microlet lancets cannot be used in Accu Chek Softclix.

  • @gowrikorada3217
    @gowrikorada3217 2 ปีที่แล้ว +1

    TQ sir

  • @alexbane6005
    @alexbane6005 2 ปีที่แล้ว +1

    Sir my device is not puncturing skin properly it is not going much deep . Can we fix it.

    • @bicyclecolours8988
      @bicyclecolours8988  2 ปีที่แล้ว +1

      Hi Alex, Can you please check if rotating cap and setting needle penetration depth to higher value helps.
      If the cap mechanism is broken then it will be difficult to fix. You need to get a new lancing device.

    • @sultanafathima480
      @sultanafathima480 2 ปีที่แล้ว

      please fix in point 4,
      in hospitals they generally keep in 4 point to go into the skin

  • @ravi_upadhyay86
    @ravi_upadhyay86 2 ปีที่แล้ว +1

    One needs ko kitni bar use kar sakte hai

    • @bicyclecolours8988
      @bicyclecolours8988  2 ปีที่แล้ว

      Hi Ravi, with every use the needle lose sharpness so if you are sensitive to pain then can hurt. If there is no skin or blood infection then can decide to use needle couple of times more provided the needle is used in a very sterile conditions. Please note as per user instructions it is recommended to use needle once.

  • @premlataramshankar3029
    @premlataramshankar3029 2 ปีที่แล้ว

    Kya ye lancet Dr trust me use nahi kar sakte

    • @bicyclecolours8988
      @bicyclecolours8988  2 ปีที่แล้ว

      Hi Premlata, The Accu Chek pin cannot be used in Dr Trust lancing device.
      But you can buy 'Accu Chek Softclix' lancing device separate for lancing purpose and use Dr Trust Glucometer for sugar measurement.

  • @shankarbasnet5832
    @shankarbasnet5832 ปีที่แล้ว

    Hello sir i just used one for my father.....and after using it for my father i was curious to know about mine....and there were shortage of Needles so i used the same needle which i had used for my father.... will it be any problem??? I'm so worried please reply....and ya before using i cleaned the needle with water..??

    • @bicyclecolours8988
      @bicyclecolours8988  ปีที่แล้ว

      Hi Shankar, I hope your father doesn’t have any skin or blood infection, until then it’s safe. Always use a new, sterile needle and never share. Keep in mind that cleaning by any means does not make re-using the needle risk-free.

    • @sanjibdebnath3834
      @sanjibdebnath3834 ปีที่แล้ว

      It's very risky for spreading disease, please use a new Lancet.

  • @ajishandashwi2945
    @ajishandashwi2945 3 ปีที่แล้ว

    I pricked in to my finger after two hours of check a persion suger level...can I get hiv on this way

    • @bicyclecolours8988
      @bicyclecolours8988  3 ปีที่แล้ว +1

      Hi Arun, I hope that person doesn’t have any skin or blood infection, until then it’s safe.
      To keep yourself safe from poking next time pls follow practice shown in video - hold top cover with both thumbs while uninstalling and pull down ejector thus keeping needle facing downwards so it doesn’t take a flight.

  • @skr6790
    @skr6790 ปีที่แล้ว

    How many time I can use one lancet (niddle)

    • @bicyclecolours8988
      @bicyclecolours8988  ปีที่แล้ว

      Hi SKR, The needles are for single use. These will loose sharpness after each use and may cause pain over repeated use.

  • @raghuramjanamanchi9893
    @raghuramjanamanchi9893 ปีที่แล้ว +1

    Sorry to say that... You haven't explained, what are 1,2,3,4 numbers on the softclix...! Which number indicates higher depth & which number indicates lower depth...? Please try to explain...!

    • @bicyclecolours8988
      @bicyclecolours8988  ปีที่แล้ว +1

      Hi Raghuram, Sry to miss this section.
      The Softclix device offers 11 penetration depth options. The penetration depth is 0.8 mm at the first setting and increases by 0.15 mm with each setting. The settings are shown on the cap by the numbers 1 to 5 with additional levels marked with dots to enable you to precisely adjust to your individual skin type.
      Select the first setting, 0.5, for the smallest depth of penetration, and the last setting, 5.5, for the greatest depth of penetration. Select 0.5 to 1.5 for softer-than-average skin, 2 to 3.5 for average skin, and 4 to 5.5 for harder-than-average or calloused skin.
      Setting 0.5 - 0.80 Penetration Depth (mm)
      Setting 1 - 0.95 Penetration Depth (mm)
      Setting 1.5 - 1.10 Penetration Depth (mm)
      Setting 2 - 1.25 Penetration Depth (mm)
      Setting 2.5 - 1.40 Penetration Depth (mm)
      Setting 3 - 1.55 Penetration Depth (mm)
      Setting 3.5 - 1.70 Penetration Depth (mm)
      Setting 4 - 1.85 Penetration Depth (mm)
      Setting 4.5 - 2.0 Penetration Depth (mm)
      Setting 5 - 2.15 Penetration Depth (mm)
      Setting 5.5 - 2.30 Penetration Depth (mm)

    • @raghuramjanamanchi9893
      @raghuramjanamanchi9893 ปีที่แล้ว

      @@bicyclecolours8988 Good explanation...!Thank you for immediate response..! You please edit your video attaching the superscribed info...!

  • @diyaverma2211
    @diyaverma2211 ปีที่แล้ว

    Is it disposable??

    • @bicyclecolours8988
      @bicyclecolours8988  ปีที่แล้ว

      Hi Diya, the lancet needle is disposable and pen is reusable.

  • @ddvantandar-kw7kl
    @ddvantandar-kw7kl 11 หลายเดือนก่อน

    Good needles were from different company

    • @bicyclecolours8988
      @bicyclecolours8988  11 หลายเดือนก่อน

      Hi, You need to use the same brand Accu Chek to use in this device.

  • @utsavkatiyar4985
    @utsavkatiyar4985 3 ปีที่แล้ว

    There is some issue with my lancet device... Its not loading even when i press it... Any idea how to make it work?

    • @bicyclecolours8988
      @bicyclecolours8988  3 ปีที่แล้ว

      Hi, There seems to be an slip between cam and ratchet mechanism and causing no loading. Sorry to say if you try to open and fix then probably not able to put back again due to factory assembly. Also for this device there is no spare or service availability.

    • @utsavkatiyar4985
      @utsavkatiyar4985 3 ปีที่แล้ว

      @@bicyclecolours8988 okay thanks

  • @shaziaparveen1186
    @shaziaparveen1186 3 ปีที่แล้ว

    I m using this for my mom.. when i was remove the niidle ...wo mere chub gyi dhoke se... koi problem to nahi hogi..plz reply

    • @bicyclecolours8988
      @bicyclecolours8988  3 ปีที่แล้ว +1

      Hi Shazia, I hope your mom doesn’t have any skin or blood infection, until then it’s safe.
      To keep yourself safe from poking next time pls follow practice shown in video - hold top cover with both thumbs while uninstalling and pull down ejector thus keeping needle facing downwards so it doesn’t take a flight.

    • @shaziaparveen1186
      @shaziaparveen1186 3 ปีที่แล้ว +1

      @@bicyclecolours8988 thanxx alot🙂

  • @giegie3015
    @giegie3015 2 หลายเดือนก่อน

    0:33 i heared the click sound but when i rotate it, the upper part will pop out..
    Pls help me..

    • @bicyclecolours8988
      @bicyclecolours8988  2 หลายเดือนก่อน

      Hi, Looks like there is a mechanism failure. Can you please try installing lancet pin one more time and redo rotating cap. If nothing works then you may need to replace lancet device as there is no service options available for the device.

    • @giegie3015
      @giegie3015 2 หลายเดือนก่อน

      @@bicyclecolours8988 thank you

  • @militarybutterflycreoleblo7326
    @militarybutterflycreoleblo7326 2 ปีที่แล้ว

    I'm sorry but we're you saying press the aluminum? I'm so confused. 🤔

    • @bicyclecolours8988
      @bicyclecolours8988  2 ปีที่แล้ว +1

      Hi, Sorry.. will soon upload subtitles.
      For your quick understanding for time being:
      At 00:42 - Press the plunger.
      At 000:52 - Press the yellow button.
      If you have any other questions at any part of the video please do let me know.

    • @militarybutterflycreoleblo7326
      @militarybutterflycreoleblo7326 2 ปีที่แล้ว +1

      @@bicyclecolours8988 Thank you!!! 😊

  • @MDrepresentah
    @MDrepresentah 2 ปีที่แล้ว

    Can I preloadire than 1 lancet at a time?

    • @bicyclecolours8988
      @bicyclecolours8988  2 ปีที่แล้ว

      Hi Jay, This device is only capable of having only one lancet at a time.

    • @MDrepresentah
      @MDrepresentah 2 ปีที่แล้ว

      @@bicyclecolours8988 hmm so is it the Fastclix that lets you load more than one?

    • @bicyclecolours8988
      @bicyclecolours8988  2 ปีที่แล้ว +1

      Hi Jay, Yes, Fastclix has a drum with 6 preloaded lancets.

    • @MDrepresentah
      @MDrepresentah 2 ปีที่แล้ว +1

      @@bicyclecolours8988 thanks gotcha

  • @gabrieluribe1852
    @gabrieluribe1852 2 ปีที่แล้ว

    I'll just keep using my older True Metrix needle pin, I still have 4 boxes of needles

    • @bicyclecolours8988
      @bicyclecolours8988  2 ปีที่แล้ว

      Hi Gabriel, The needles are for single use. These will loose sharpness after each use and may cause pain over repeated use.