Using FactoryTalk Logix Echo Tutorial

แชร์
ฝัง
  • เผยแพร่เมื่อ 23 พ.ย. 2024

ความคิดเห็น • 38

  • @ShaneWelcher
    @ShaneWelcher  2 ปีที่แล้ว +1

    Subscribe: mmini.me/Subscribe-4-Updates
    Other socials:
    Facebook: facebook.com/OnlinePLCSupport
    LinkedIn: www.linkedin.com/in/shane-welcher-sr/

    • @jmccabe419
      @jmccabe419 ปีที่แล้ว

      Just out of curiosity if your trying to simulate something would you go with Emulate 3D from Rockwell or nirtec east plc? We have emulate 3d but not sure if it’s as quick as the conveyor builder in nirtec

    • @ShaneWelcher
      @ShaneWelcher  ปีที่แล้ว

      @@jmccabe419 not using emulate 3D

  • @pankajmishra4497
    @pankajmishra4497 2 ปีที่แล้ว +1

    Good Stuff. Was waiting long time for it to be rolled out.

  • @jmccabe419
    @jmccabe419 ปีที่แล้ว +1

    Great video just getting to use echo at work

  • @EternalNOP
    @EternalNOP ปีที่แล้ว +1

    So, questions on what PLCs can you use, it is only the following PLC Firmware as of 2023/3/31
    5580 ControlLogix - firmware versions 35.11, 34.11, 33.11
    5580 GuardLogix - firmware versions 35.11
    Echo software versions out are 2.01 and 1.
    CompactLogix is not out at this time.
    Note that this is not StudioLogix versions.

    • @ShaneWelcher
      @ShaneWelcher  ปีที่แล้ว

      I use Echo V1, haven't upgraded yet.
      Yes, I know it's a bit limited

    • @EternalNOP
      @EternalNOP ปีที่แล้ว +1

      @@ShaneWelcher, Thanks for clarifying what you are running. My note was for the general audience. Just installed V2.01, as I am working to use Echo on one VM and want to talk with another VM running System Platform for development. Did it with Rocwell Emulate 8 years ago or so...

  • @sydnieseckinger6257
    @sydnieseckinger6257 10 หลายเดือนก่อน +1

    Hi @ShaneWelcher, what if the chosen IP address/Device is showing as Unknown? I'm a new grad, so learning everything from scratch mostly.

    • @ShaneWelcher
      @ShaneWelcher  10 หลายเดือนก่อน

      That means you need to update the eds files

  • @controlfreak1963
    @controlfreak1963 6 หลายเดือนก่อน +1

    I wish this was available for lower end controllers. We already pay through the nose for development licenses.

    • @ShaneWelcher
      @ShaneWelcher  6 หลายเดือนก่อน

      It does allow lower end processors on version 2 and added the controllers like safety and compact logix.
      From version 36 and higher.

  • @suriyat8773
    @suriyat8773 6 หลายเดือนก่อน +1

    Thank You

    • @ShaneWelcher
      @ShaneWelcher  6 หลายเดือนก่อน

      Glad it was helpful

  • @Amin-23k
    @Amin-23k ปีที่แล้ว +1

    Hi Shane, i wanna emulate guardlogix by v34.11 revision,
    but i don't have, it in the FactoryTalk Logix Echo catalog.
    can you advise me where can i find it...
    Thank you from your follower from Morocco.

    • @ShaneWelcher
      @ShaneWelcher  ปีที่แล้ว

      You may need to update FactoryTalk Echo to use V34.
      Get that from the PCDC section of the Rockwell Automation website

  • @balajitakle145
    @balajitakle145 2 ปีที่แล้ว +1

    If we download the project then if i m having remote io's so echo will take care for all that?

    • @ShaneWelcher
      @ShaneWelcher  2 ปีที่แล้ว

      Using echo allows the PLC processor to scan the code, not the I/O cards.
      It basically puts them in a non connected status

  • @xyzhouse
    @xyzhouse ปีที่แล้ว +1

    one thing is that you still can use RSlinx to communicate with Echo

    • @ShaneWelcher
      @ShaneWelcher  ปีที่แล้ว

      Just follow what I show that easily works

  • @zackzhu1617
    @zackzhu1617 2 ปีที่แล้ว +1

    Hi Shane, how should we add new firmware into this echo , right now im only able to create for V33.11 , looking to use it for V34

    • @ShaneWelcher
      @ShaneWelcher  2 ปีที่แล้ว +1

      Right now, I do not believe there is an option for that.
      Echo is new & is something they need to make some improvements on so I think that is what they are concerned with instead of new versions.
      At least as of 7-26-2022 from my knowledge.

    • @zackzhu1617
      @zackzhu1617 2 ปีที่แล้ว

      @@ShaneWelcher Thank you , your videos are amazing 👍

    • @zackzhu1617
      @zackzhu1617 2 ปีที่แล้ว +1

      @@ShaneWelcher Hi Shane, I manage to find the option , on the most bottom left there is a option to add firmware packages. Cheers

    • @ShaneWelcher
      @ShaneWelcher  2 ปีที่แล้ว +1

      @@zackzhu1617
      Good to know...I do know that they have efforts around fixing a few bugs.
      Just wanted to let you know.
      With that said, they are generally fast at fixing things especially in the last two years

  • @victormtzc
    @victormtzc 7 หลายเดือนก่อน +1

    does it support simulation of safety logic?

    • @ShaneWelcher
      @ShaneWelcher  7 หลายเดือนก่อน

      Yes on version 35 and 36

  • @ludansy
    @ludansy 2 ปีที่แล้ว +1

    Can The Echo Run with comactlogix 5380 controller?

    • @ShaneWelcher
      @ShaneWelcher  2 ปีที่แล้ว

      Yes, Echo is new though so using multiple controllers takes time.

  • @puneetpathak7686
    @puneetpathak7686 2 ปีที่แล้ว +1

    Can the Echo run with logix version 33.01?

    • @ShaneWelcher
      @ShaneWelcher  2 ปีที่แล้ว

      Yes, you need to add the firmware for that.

  • @germancanahuire6782
    @germancanahuire6782 2 ปีที่แล้ว +1

    Hi , it is work with devicenet network ??? Thanks

    • @ShaneWelcher
      @ShaneWelcher  2 ปีที่แล้ว

      Echo works all field devices

  • @zackzhu1617
    @zackzhu1617 2 ปีที่แล้ว +1

    Is Logix Echo able to do a redundancy simulation?

    • @ShaneWelcher
      @ShaneWelcher  2 ปีที่แล้ว +1

      There is a known issue when using multiple controllers in Logic Echo as of 7-22-2022, Rockwell is working on this & may have a resolution by now, however I am not aware of that fix.
      Echo is a new product from Rockwell so they are going through growing pains from what I see unless you have a lot of ram being used fast CPU being that Echo is computer based.

    • @adamplesyt
      @adamplesyt 2 ปีที่แล้ว

      You can download redundant project into Echo controller, but it would show status "primary without secondary".

    • @ShaneWelcher
      @ShaneWelcher  2 ปีที่แล้ว

      @@adamplesyt You'll run into problems running multiple PLC programs with Echo right now on Echo version 1.
      It is a known fact.
      They are working on making it more durable.