50 Amp RV Circuit Install / EMT Conduit Bending & Wire Pulling

แชร์
ฝัง
  • เผยแพร่เมื่อ 5 ก.ย. 2024
  • Step-by-step installation instructions on how to wire a 50 amp RV receptacle to your home for your travel trailer or fifth wheel!
    With 15yrs of Electrical experience, I may have a few tips and shortcuts that can save you money and headaches going this install for the first time. Electrical Installation can be somewhat confusing and store clerks can lead you to spending a lot of hard earned money. So sit back watch the video an let me know if you have any questions. Light up your life......
    It would be awesome if you can support me by giving me a Thumbs up. To help this channel out hit that like button Please. Subscribe and Hit that Notification Button!!!!!!!
    #Electrician, #MasterElectrician, #Electrician Tools,

ความคิดเห็น • 52

  • @Neil-ym8vy
    @Neil-ym8vy ปีที่แล้ว +4

    You must have worked under good JM Electricians before. Never seen an Electrician work so fast. Most of the ones I worked with would be looking for the nearest portable John by now or where the closest Dunkin Dounuts is?
    LMAO

  • @easternyellowjacket276
    @easternyellowjacket276 หลายเดือนก่อน

    What a fantastic job, sir! Thank you for the video!

  • @jontreltaylor
    @jontreltaylor 10 หลายเดือนก่อน +2

    Great job brother!!👏🏾👏🏾👏🏾 I'm a fellow automation engineer & i love seeing us out here showcasing our skills & professional attributes. Keep teaching them...💪🏾💪🏾💪🏾💯💯

  • @maxbell6103
    @maxbell6103 2 ปีที่แล้ว +5

    I didn’t know about the dish soap trick!! Great video I learned lots!!

    • @unitedtradesmanacademy1894
      @unitedtradesmanacademy1894  2 ปีที่แล้ว +1

      Yup that's a old trick l, can't take this info with me. Thanks for watching an comments.

  • @joehopkins1388
    @joehopkins1388 ปีที่แล้ว +3

    Great work ! I'm often a 1 man show at my place. I need to install a 50 amp for my RV near the house. Found some great tips in your video.

  • @user-zo7qm5mz3b
    @user-zo7qm5mz3b 9 หลายเดือนก่อน +1

    Nice job, thank you, please do more. Just a few suggestions: edit video down to shorten length; describe tools and materials used and where to buy them.

  • @robertogarco6976
    @robertogarco6976 2 ปีที่แล้ว +3

    Great job, that's a two man job easy 👏 pulling those conductors like a one man army!!! When there's a will there's a way you said that right! We start at 5am and out at 2pm so it be cold then hot Tucson az! Your representing Us good! Take care God bless you and family! Keep them coming!

    • @unitedtradesmanacademy1894
      @unitedtradesmanacademy1894  2 ปีที่แล้ว

      Roberto thanks for commenting i really would like to meet all the people who leave comments. Imma have to do a twitch video one day where we can all chat.

  • @derronkerr5787
    @derronkerr5787 2 ปีที่แล้ว +5

    Good job 👍..I do a lot of jobs like that by myself too.

  • @tjmooney4181
    @tjmooney4181 ปีที่แล้ว +1

    Thanks 👍

  • @vince6829
    @vince6829 ปีที่แล้ว +2

    Nice job. Thanks for sharing.

  • @samsen3965
    @samsen3965 ปีที่แล้ว +3

    Great but for someone as ignorant as me, I have a serious question. Why did you opt to go down from the main panel, to near ground, even passing under the gutter outlet 22:33 where it certainly flood sometimes in the future, keeping your high volt cable under water, when you could easily go up from the panel thus keeping your line near the cover of a roof, away from all the elements of the next century and especially danger of water? At least I know, water and electricity won't mix!
    Thanks

    • @unitedtradesmanacademy1894
      @unitedtradesmanacademy1894  ปีที่แล้ว +1

      Customer wanted it down low.

    • @samsen3965
      @samsen3965 ปีที่แล้ว +3

      @@unitedtradesmanacademy1894
      Thanks for explaining & OK. But good personnel such as yourself has the responsibility of educating the ignorant customer and ensuring safety in the first place. If not by now, one day and in a disastrous moment of the flood they will realize it in a hard sad way!. I guess but I hope not.

  • @billmellinger1134
    @billmellinger1134 10 หลายเดือนก่อน +2

    What size wire did you use for this?

  • @ricklarson9524
    @ricklarson9524 ปีที่แล้ว +1

    Clean job

  • @hoyte44
    @hoyte44 ปีที่แล้ว +1

    Hey great job thanks for sharing your videos👍🏿

  • @meanstreetmma78
    @meanstreetmma78 ปีที่แล้ว +3

    how much does a job like that cost?

  • @stanhopkins562
    @stanhopkins562 5 หลายเดือนก่อน

    Good job 👍🏾

  • @melvinomarpacheco1216
    @melvinomarpacheco1216 2 ปีที่แล้ว +1

    Liked the video thank you so much I learned a lot of good things thank you

  • @Sweet_Yanira
    @Sweet_Yanira ปีที่แล้ว +1

    To bad you're not in Citrus County, Florida and do any pro bono work for someone who was abandoned with a back injury. 😔 You really did an awesome & professional job. 👍🏼

  • @thegoodlightllc4093
    @thegoodlightllc4093 2 ปีที่แล้ว +1

    Well done!

  • @scubamystic8860
    @scubamystic8860 7 หลายเดือนก่อน +1

    Great video. Did you have to pull a permit for this?

  • @kashimiller1765
    @kashimiller1765 2 ปีที่แล้ว +1

    Great job bro

  • @danielkofman4592
    @danielkofman4592 ปีที่แล้ว +2

    Was thay 3/4 or 1 inch conduit emt? Nice job btw!

  • @ahmedbelly1926
    @ahmedbelly1926 2 ปีที่แล้ว

    That boy good.

  • @sarentopi1502
    @sarentopi1502 2 หลายเดือนก่อน

    Are those LBs rated for wet locations?

  • @JackTheAwesomeKnot
    @JackTheAwesomeKnot 2 หลายเดือนก่อน +1

    That EMT gonna rust, pvc would be the better choice

  • @samsen3965
    @samsen3965 ปีที่แล้ว +1

    Is there RV plugs as good and as safe as routine in garage EV NEMA plugs?

  • @weinheimer1000
    @weinheimer1000 10 หลายเดือนก่อน

    Why can’t you move the brick and dig a lit dirt to keep pipe all the way at same level without any bends?

  • @23Noble
    @23Noble 3 หลายเดือนก่อน

    What type pipe is it?

  • @sedona1234566
    @sedona1234566 2 ปีที่แล้ว +1

    As an instructional video try to follow the NEC a bit more, re-identifying conductors under #4 is not compliant.

  • @keithharrington8715
    @keithharrington8715 2 ปีที่แล้ว

    Sir. I have some questions.
    2020 NEC 550 does not apply here?
    406.9.(B).(2). Applicable?
    210.8.(A).(3). Maybe?
    200.6.(A). Mentioned by another commentor
    250.119. Not shown well enough in video.
    I only put the code sections because your video did not show some items for easy identification. I hope you got it right and I know that 2020 NEC 90.4 can erase every bad comment.
    Thanks for the viddeo and the code review I got.

  • @parochial2356
    @parochial2356 2 ปีที่แล้ว +1

    The house suffered a fire and the utilities dept. didn't pull the meter?

    • @unitedtradesmanacademy1894
      @unitedtradesmanacademy1894  2 ปีที่แล้ว

      Fire only caught a few outlets on fire

    • @parochial2356
      @parochial2356 2 ปีที่แล้ว

      @@unitedtradesmanacademy1894 Hmmm...... I would have thought service would be cut until an electrician could repair the known damage and certify that there was no other unknown/concealed damage. Potential [big?] liability. But the the AHJ and fire Department makes the call.

  • @afzalhakeen4941
    @afzalhakeen4941 ปีที่แล้ว +1

    i would just cut off some of the gutter and moved that brick away

  • @quickname8046
    @quickname8046 2 ปีที่แล้ว +3

    lost the audio while you were bending pipe broski

    • @unitedtradesmanacademy1894
      @unitedtradesmanacademy1894  2 ปีที่แล้ว +1

      Sorry broski, I didnt realize until after. I can make another video on bending pipe if you need me too?

    • @quickname8046
      @quickname8046 2 ปีที่แล้ว +1

      @@unitedtradesmanacademy1894 yessir i actually have a similar project to the one you just made

    • @unitedtradesmanacademy1894
      @unitedtradesmanacademy1894  2 ปีที่แล้ว +2

      @@quickname8046 ok if i have time tommorrow i will make a tutorial on bending pipe

  • @JulianIsDown
    @JulianIsDown 2 ปีที่แล้ว +2

    conduit bending kinda sus, for what this job was, 3/4 wouldve been perfect and easier to bend.

    • @unitedtradesmanacademy1894
      @unitedtradesmanacademy1894  2 ปีที่แล้ว +1

      Yes you are right but i was doing this job alone an pulling through 3/4c. would be a little tough alone.

  • @trustme7731
    @trustme7731 2 ปีที่แล้ว +1

    Dish soap is NOT an approved wire lube and thus a code violation.
    But the big violation is NO GFCI protection as required. I guess that means you had no permit and inspection for this job.

  • @pedroguzman9542
    @pedroguzman9542 8 หลายเดือนก่อน +1

    Too low emt

  • @tjmooney4181
    @tjmooney4181 ปีที่แล้ว +1

    Thanks 👍