How to install and align a pump and motor coupling on an API 610 VS4 pump

แชร์
ฝัง
  • เผยแพร่เมื่อ 25 ธ.ค. 2024

ความคิดเห็น • 6

  • @bilhagy
    @bilhagy 3 ปีที่แล้ว

    Hello,
    I have a pump where the spacer slightly moves to the left and right between the two couplings
    IS THAT NORMAL? OR SHOULD THE SPACER NOT MOVE AT ALL?

  • @lingeshwaranb28
    @lingeshwaranb28 2 ปีที่แล้ว

    What is the type of coupling being used?

  • @nextrotatingsolutions9950
    @nextrotatingsolutions9950 4 ปีที่แล้ว +1

    ... Did you just use a ruler to check alignment? if you manufacture API equipment please have your clients use a dial or laser. Based on RPM you should be aiming for .05-.09 mil angular and 1-1.5 mil offset. Also is this doweled, flat faced or a spigot? Even a spigot can have a .005"-.0020" slop. Don't for get to check you TIR at the shaft closet to the coupling to ensure you have done the alignment correct

  • @Prabhuchamy1
    @Prabhuchamy1 5 ปีที่แล้ว

    Why can't you install the motor side coupling beforehand

  • @PilgrimPiper
    @PilgrimPiper 2 ปีที่แล้ว

    👀

  • @cck1496
    @cck1496 2 ปีที่แล้ว

    I don't think so,it will give you correct alignment.... It's just a rough alignment..