Hacking a Siemens S7-300 PLC

แชร์
ฝัง
  • เผยแพร่เมื่อ 19 ม.ค. 2025

ความคิดเห็น • 17

  • @The_3_Triangle
    @The_3_Triangle หลายเดือนก่อน

    nice dump program almost similar what i made years ago for siemens ...i love the program written in STL ... great demonstration ...

  • @FDFcz
    @FDFcz 2 ปีที่แล้ว +1

    Well there is guestion. Is that emergenci stop in safety program ? Or only in regular program ?

    • @alphastrikelabs
      @alphastrikelabs  2 ปีที่แล้ว

      Hi Filip! What do you mean by that? Could you explain further?

    • @FDFcz
      @FDFcz 2 ปีที่แล้ว +1

      @@alphastrikelabs well, I dont know how much exacly you know about PLCs, but I try to describe it. In simatic PLC is sfety part of program. And that part is loading difernetly to PLC than normal part of program. My question is, is that code inside safety part or normal ?

    • @alphastrikelabs
      @alphastrikelabs  2 ปีที่แล้ว +1

      @@FDFcz We had no chance to test this, so we can not tell whether this kind of manipulation works on an F-CPU.

  • @saqibmian2010
    @saqibmian2010 2 ปีที่แล้ว +1

    Does anyone know the program used to fo the PLCDUMP?

    • @alphastrikelabs
      @alphastrikelabs  2 ปีที่แล้ว

      Hi Muhammad! Unfortunately we cannot tell you the name of the application used in the video. But we do have a similar application, that you could use. If you're interested, please send an email to office@alphastrike.io

  • @haroonrehman8156
    @haroonrehman8156 2 ปีที่แล้ว +1

    Love that video.

  • @soylk9436
    @soylk9436 3 ปีที่แล้ว +2

    hello .the video is great . i have the same idea i want to realise it in my final year project . could you please give me a way to contact you i want some informations
    thanks in advance

    • @alphastrikelabs
      @alphastrikelabs  2 ปีที่แล้ว

      Hi, thanks for the feedback! If you're still interested in working with us feel free to send us an email to office@alphastrike.io

  • @maciejokon7419
    @maciejokon7419 10 หลายเดือนก่อน

    Oh dear... This is why you should use safety circuits isolated from network and programming.
    In the industry standards there is requirement you have to place emergency button serial safety circuit. In this case you should place it serial with solenoid coil control signal. If you hit emergency button there is no option valve has power supply so everything is safe ;)
    But hacking of plc is of course a big problem and it can make problems like destroying of machine, makeing breakdowns, quality loss, etc. Anyway it shouldnt make danger for workers so emergency button isn't appropriate!

  • @nusret294
    @nusret294 2 ปีที่แล้ว +1

    Exelent an other video pleas

  • @agimaroc1032
    @agimaroc1032 3 ปีที่แล้ว +2

    Can you send me your name application

    • @alphastrikelabs
      @alphastrikelabs  2 ปีที่แล้ว

      Unfortunately we cannot send you the name of the application that we use in the video. But we do have a similar application, that you could use. If you're interested, please send an email to office@alphastrike.io

  • @iamvehicle8596
    @iamvehicle8596 3 ปีที่แล้ว +1

    StuxNet xDD

    • @maktiki
      @maktiki 2 ปีที่แล้ว

      Similar principles yes

  • @agimaroc1032
    @agimaroc1032 3 ปีที่แล้ว

    Hello