  • @adynuff7678
    @adynuff7678 2 ปีที่แล้ว +7

    A very useful video, I used your technique to find and fix a short circuit in my caravans 12v lighting circuit, which turned out to be two trapped wires where a light was poorly fitted by the manufacturer. Great stuff cheers.

  • @tekopikin
    @tekopikin 2 ปีที่แล้ว +1

    It's 2022 and your video was the first result I found from an Online search, I just need to get me a multimeter or a bulb kit - whichever I can get a hold of first to fix a short which keeps blowing my instrument cluster fuse. Will let you know how it goes.
    Big thanks for this tutorial

  • @gordonbarclay6106
    @gordonbarclay6106 3 ปีที่แล้ว +6

    Superb video. I can now use these methods to try and find the fault I have in the car. Every time I turn on the side lights it blows the fuse for the left-hand side only straight away. Should save me a fortune on fuses and by the way this has been the best video for explaining different methods with the bulb and the multimeter.

  • @sarahlouise1152
    @sarahlouise1152 4 ปีที่แล้ว +7

    My husband just came trotting in with excitement that you have uploaded a new video!! 😂

    • @rmautodiag
      @rmautodiag  4 ปีที่แล้ว +1

      👍😂 glad he's enjoying the content👍

  • @dalecolbert232
    @dalecolbert232 2 ปีที่แล้ว +1

    You are the man! I plugged in a light bulb and when I pulled the horn relay it went out. Thanks a million

    • @rmautodiag
      @rmautodiag  2 ปีที่แล้ว

      No problem thanks for the comment

  • @j.goebbels2134
    @j.goebbels2134 ปีที่แล้ว

    Thanks for this video. Finally someone who knows what they are talking about !
    I have a newer 1500-watt inverter, which I had been using fine for months. I accidentally shorted it out. Opened it. Found 4 x 30a fuses in there. I saw the first in line was blown. So... easy. I replaced it. But I didn't have a 30a large blade, so I replaced with a 40a large blade. No problem, it is a little bigger so won't blow as fast as a 30, but still small enough that it will blow if it needs to.
    BUT... it blew! right away. With only about 650 watts device on it.
    Put in another 40a, which also blew.
    Put in another 40 and using the inverter now for only charging small, low amp devices while I figure this out, which seems to be working fine, but waste of a huge inverter like this. Is something else wrong inside there that the short caused and that is why it keeps blowing? Or is the 40a blowing where a new 30a would not?? It seems the 40a would blow LAST instead of first, inline with all the other 30s...
    Hmmmm

  • @godofyota9541
    @godofyota9541 2 ปีที่แล้ว +4

    The light bulb technique helped me locate my short. Excellent info!!
    Thanks

    • @rmautodiag
      @rmautodiag  2 ปีที่แล้ว

      Thanks for the comment

  • @orlandoo4552
    @orlandoo4552 2 ปีที่แล้ว +6

    Great video! I like how you show alternative ways of testing. I really like the continuity testing method. Instant like and new follow.

    • @rmautodiag
      @rmautodiag  2 ปีที่แล้ว +2

      Thanks for the support 👍

  • @paulywalnuts5117
    @paulywalnuts5117 3 ปีที่แล้ว +2

    Thanks, made it that much easier to find the source causing the problem

    • @rmautodiag
      @rmautodiag  3 ปีที่แล้ว

      Glad I could help, thanks for the comment.

  • @madgin1
    @madgin1 4 ปีที่แล้ว +6

    Great to see this done in a few different ways. Top tips👍

    • @rmautodiag
      @rmautodiag  4 ปีที่แล้ว +1

      Thanks for the comment. Hope it helps you.

  • @jd-kd3mm
    @jd-kd3mm 4 ปีที่แล้ว +4

    Awesome, simple explanation! Makes a lot more sense now!

    • @rmautodiag
      @rmautodiag  4 ปีที่แล้ว

      Thanks for the comment 👍

    • @panzerwaffen2873
      @panzerwaffen2873 4 ปีที่แล้ว

      @@rmautodiag boss man I just replaced the bcm on my car but now the AC doesn't work it blows but no cold ... Wiper blades blown fuse ...trunk same thing and the sound inside the car also ... All of these fuses are in different boxes ...

  • @heroknaderi
    @heroknaderi ปีที่แล้ว +1

    This video is very informative. thank you.

  • @rjshhooba9857
    @rjshhooba9857 ปีที่แล้ว

    yep , if you do not already know, turning signals and cigarette lighter are connected to the same ground on the vehicle

  • @richardworden9747
    @richardworden9747 2 ปีที่แล้ว +1

    I am an electrician by trade and was thinking the same thing can I use a light bulb I tried to Google it on TH-cam and all I found was you thank God I did.

    • @rmautodiag
      @rmautodiag  2 ปีที่แล้ว

      Thanks for the comment😀

  • @RJ6AV6
    @RJ6AV6 2 ปีที่แล้ว +1

    Thank you for this video, really clear and concise! 👍👍

    • @rmautodiag
      @rmautodiag  2 ปีที่แล้ว

      Thanks for the comment

  • @davidk3119
    @davidk3119 3 ปีที่แล้ว +2

    Thanks! My car blows a fuse whenever I plug in the cigarette lighter or a phone charger. I use the multimeter to check for voltage at the fuse and it is around 12 volts. I did the continuity test and it is not getting continuity. Does that mean there is a fault in the wiring somewhere? I checked the wiring around the lighter and it looks okay. The wiring goes up into the dash so who knows what is going on up there.

  • @PioneerMountainHomestead
    @PioneerMountainHomestead 2 ปีที่แล้ว +1

    very good demonstration, thanks

    • @rmautodiag
      @rmautodiag  2 ปีที่แล้ว

      Thanks for your comment 👍

  • @craigdecolumbian2688
    @craigdecolumbian2688 3 ปีที่แล้ว +3

    Very informative and helpful 👍

    • @rmautodiag
      @rmautodiag  3 ปีที่แล้ว

      Thanks for the comment

  • @HOTRODRICO
    @HOTRODRICO 2 ปีที่แล้ว

    those parts you bent outward are what holds whatever you put into the lighter socket, they were supposed to be bent inward not outward right ? or am I missing the idea here...? thanks

  • @elcidlord
    @elcidlord 2 ปีที่แล้ว

    I have a 2005 Dakota, 3.7L., 128,000 miles. The power outlet fuses one or the other blow, 20amp. This started to happen when I use my plug-in air compressor to fill the tires after a few minutes running. I have done this for many years with the same plug-in air compressor, same Dakota, no problem. Now my dash cam is always plugged in to the power outlet when driving and the power outlet fuses never blow/burn out. The garage could only suggest my air compressor is old and causing the problem. What position do I set my multi-meter on? Not to knowing of how to use one. Sorry. Any advice would be greatly appreciated. I hope I explained this correctly. Thank you.

  • @sillygily4435
    @sillygily4435 ปีที่แล้ว

    How do you know the input and output side of a fuse?

  • @knightrider5825
    @knightrider5825 4 ปีที่แล้ว +1

    Thanks for these informative videos👏🏼

    • @rmautodiag
      @rmautodiag  4 ปีที่แล้ว

      Thanks for the comment

  • @k1ortia
    @k1ortia 3 ปีที่แล้ว

    When i turn my side lights on on my motorbike it constantly keeps blowing the 10a fuse, this never happened before, when i checked its the tail light fuse. Any ideas how to fix this or where i should be looking to find the cause? Thank you and great video.

  • @anthonysova7117
    @anthonysova7117 8 หลายเดือนก่อน

    Is it common to refer earth to reference ground where your from?Just don’t see earth on a vehicle with no connection to earth having rubber to the road Not a big deal but never heard anyone use that reference Cheers thumbs up

  • @ramondouche3640
    @ramondouche3640 2 ปีที่แล้ว

    Can I use any bulb or is it specific to volts and or current?

    • @dieseldawg7132
      @dieseldawg7132 ปีที่แล้ว

      Just use a test light, the grounded side of the fuse and positive or the battery

  • @chuySG1
    @chuySG1 4 ปีที่แล้ว

    I have a 2000 Honda Accord EXL. When I attempt to replace the passenger side window fuse it immediately blows? I know I have the wires cut on the horn.... Might that be on the same circuit??

  • @renflo86
    @renflo86 ปีที่แล้ว

    Awesome video

  • @vicgon5807
    @vicgon5807 3 ปีที่แล้ว

    1989 civic lx. I keep blowing fuse #8. It happens when I turn on my dashlights. So my dashlights and tailights do not light up.

  • @nikoabednego1734
    @nikoabednego1734 3 ปีที่แล้ว

    My instrumental cluster lights fuse on my vw polo keeps on blowin wat could be the cause

  • @angieMason-mm5ff
    @angieMason-mm5ff ปีที่แล้ว

    Thank you very much my cousin let a so-called friend fix it tore it up trying to fix it myself

  • @MrPhendy2002
    @MrPhendy2002 ปีที่แล้ว

    Thank you
    .

  • @hectorfuentes283
    @hectorfuentes283 4 ปีที่แล้ว +2

    my tail lights are not working brake lights are small light fuse keeps blowing as soon as i turn the lights on . Any help on this problem i am having

    • @rmautodiag
      @rmautodiag  4 ปีที่แล้ว +3

      I would put a bulb inline with the tail light fuse as seen in the video. When you turn the lights on if there is a short to ground the bulb will light. I would then disconnect the tail lights one at a time and see if the bulb goes out showing where the short is.

  • @OldSchoolNoe
    @OldSchoolNoe 3 ปีที่แล้ว +1

    Blowing an AC fuse, and this will be helpful, time to locate a wiring diagram.

    • @rmautodiag
      @rmautodiag  3 ปีที่แล้ว

      Thanks for the comment

  • @jamescardona9412
    @jamescardona9412 4 ปีที่แล้ว +1

    really helpful

    • @rmautodiag
      @rmautodiag  4 ปีที่แล้ว

      Thanks for the comment

  • @cheyennemarquez5082
    @cheyennemarquez5082 2 ปีที่แล้ว +1

    Tnx brother!

    • @rmautodiag
      @rmautodiag  2 ปีที่แล้ว

      Thanks for the comment

  • @danburger28
    @danburger28 4 ปีที่แล้ว

    good stuff as ever

    • @rmautodiag
      @rmautodiag  4 ปีที่แล้ว

      Thanks, I hope it helps you on your car journey 👍🏎

  • @alxibba1
    @alxibba1 4 ปีที่แล้ว +1

    My car radio fuse keeps blowing out, as soon as I try to replace it, it blows immediately, my car is 2002 Bmw 325 ci, need desperate help cause my windows and windshield wipers doesn’t work anymore

    • @rmautodiag
      @rmautodiag  4 ปีที่แล้ว +3

      I would look at the fuse description and see what other components are on the same fuse. Then put a small bulb in the fuse holder like shown in the video and disconnect the components on that fuse until the bulb goes out, that will be where the short is.

    • @alxibba1
      @alxibba1 4 ปีที่แล้ว +1

      RMAutodiag I’ll check it out , thank you.

    • @mickeylim399
      @mickeylim399 2 ปีที่แล้ว

      I have same year 325i did you find out anything ?? I head a 10.1 inch head unit fuse just blew today now it keeps blowing

    • @ayoubabubaker9211
      @ayoubabubaker9211 2 ปีที่แล้ว

      @@mickeylim399 did you end up fixing it

  • @claremadgin
    @claremadgin 4 ปีที่แล้ว +1

    👍

    • @rmautodiag
      @rmautodiag  4 ปีที่แล้ว