Inspection Schedule: Section 4 | Consumer unit's: A brief introduction

แชร์
ฝัง
  • เผยแพร่เมื่อ 8 ต.ค. 2024

ความคิดเห็น • 17

  • @davefrizelle3882
    @davefrizelle3882 หลายเดือนก่อน +4

    John, you said "Like with most of my videos, the editing and camera work is a bit rough, but as I'm filming on the fly as and when I find things, hopefully I'll get better as I go" ... this is what makes it real and relatable. The content is really solid. Don't worry about the production quality! Keep doing what you're doing!😀

  • @greatrixbrad
    @greatrixbrad หลายเดือนก่อน

    We didn’t get a close look at the cover stickers at the beginning, but it looks like the work of Jerry Rig Electrical Ltd. Their motto is ‘We know just enough to make it work’
    Excellent video 🎉

  • @De_Chaos
    @De_Chaos หลายเดือนก่อน

    Another great video. I enjoy the honesty and explanations. We don't need the fluff of certain other electricians videos.

  • @thattoolguy9432
    @thattoolguy9432 2 หลายเดือนก่อน +1

    Thats a classic case of the builder saying i do electrics too .. nice 1 John

  • @WithoutAPadd1e
    @WithoutAPadd1e หลายเดือนก่อน

    Love the video John. Really appreciate you giving us a real-world sparks' view of what you see on the job. The Regs seem so rigid, so it takes good judgement to apply them on the job. Thank you for sharing yours!

  • @mistakay9019
    @mistakay9019 หลายเดือนก่อน

    great vid! Not a spark but i really enjoy learning about the nuance of it all! got the sub locked on :)

  • @aryanelectrical
    @aryanelectrical หลายเดือนก่อน

    Nice video John ❤

  • @davidryan6616
    @davidryan6616 2 หลายเดือนก่อน +1

    🧐🙂🇮🇪☘️ Love the Screwdriver.

  • @lizoyako6414
    @lizoyako6414 2 หลายเดือนก่อน

    Thanks

  • @Sparks1Plumbers0
    @Sparks1Plumbers0 2 หลายเดือนก่อน

    0:37 "mounted very high"
    Yer... for a short ass 😂. Previous occupent was 6' 11" so technically could have done with being raised a tad higher 😉.
    The old adage springs to mine. Out of sight, out of mind, and as it works/worked... what's the issue.
    Anyway great video m8. Keep up the good work. 👍

  • @kyester123
    @kyester123 หลายเดือนก่อน

    Maybe put a disclaimer in the descriptions of videos to cover yourself if DIYers copy the videos

    • @John_Faultless
      @John_Faultless  หลายเดือนก่อน

      @kyester123 that's a good shout. Cheers mate

  • @shaniapearcey
    @shaniapearcey หลายเดือนก่อน

    What happened with artisan?why did you leave

    • @John_Faultless
      @John_Faultless  หลายเดือนก่อน +2

      @shaniapearcey got made redundant last year just before Xmas mate. Now doing my own thing with Faultless Electrical Services 👍

  • @tonywatson1412
    @tonywatson1412 หลายเดือนก่อน

    When you think about it...MCB,s have to perform to the same standard...SO if they are phyically the same , dimensions etc. And they fit perfectly...../ just why cant they be mixed.....obviously manufactures dont want this....Money

    • @John_Faultless
      @John_Faultless  หลายเดือนก่อน

      @@tonywatson1412 100%, there's a few that are the same parent company and have the exact same dimensions. Only a few have unique enough busbars that make this observation a real issue

  • @enochabban8086
    @enochabban8086 หลายเดือนก่อน

    John I have sent you personal messages and u did not reply