Responsibility of Civil Engineer During Concreting | Slab का Concrete करते समय Tests & Checking

แชร์
ฝัง
  • เผยแพร่เมื่อ 13 ธ.ค. 2024

ความคิดเห็น • 110

  • @dawoodjamshaid9146
    @dawoodjamshaid9146 4 ปีที่แล้ว +1

    i m a 3rd year student and after watching these videos i will be putting more concentration in the lab work... thank your sir... very interesting and knowledgeable videos... love from Pakistan

  • @debasishrko8253
    @debasishrko8253 4 ปีที่แล้ว +1

    U r best adviser sir
    Really u own my respect sir

  • @space_visions__fitouts7726
    @space_visions__fitouts7726 4 ปีที่แล้ว

    you doing good job sir

  • @virajtakale3045
    @virajtakale3045 4 ปีที่แล้ว

    Useful in preparation of checklist for rcc site work. Thank you

  • @civilengineersehbudalam8227
    @civilengineersehbudalam8227 4 ปีที่แล้ว +1

    Good job sir

  • @qasimjutt8693
    @qasimjutt8693 4 ปีที่แล้ว

    Gud work bhai

  • @hansrajparmar9500
    @hansrajparmar9500 4 ปีที่แล้ว

    Thank you so much for Civil engineer

  • @amangupta9602
    @amangupta9602 4 ปีที่แล้ว +1

    Nice video

  • @MarkaManikanta
    @MarkaManikanta 4 ปีที่แล้ว +1

    tell us about pipe culvert live demo..like what is 40 mm and 45 mm...and Head Wall , Trial Pit, and RCC Details of parapet, Longitudinal section ...those above details are imp. for pipe culvert...

  • @zoya1520
    @zoya1520 4 ปีที่แล้ว +1

    Slump-4 layer 120-150mm
    Temperature- 26-35°C

  • @civilengineeragh4770
    @civilengineeragh4770 4 ปีที่แล้ว

    Very nice sir. My company site slb is this Sunday. Quantity of concrete is 130
    m cubic I will do all method

  • @ayushkumarsingh9443
    @ayushkumarsingh9443 4 ปีที่แล้ว

    👍👍 thank you sir

  • @pawanmehra6959
    @pawanmehra6959 ปีที่แล้ว

    Sir ueh slab ki drwing reading btna sir

  • @ravidev3971
    @ravidev3971 4 ปีที่แล้ว +3

    Use scoop for cone filling

  • @dHRUV10
    @dHRUV10 3 ปีที่แล้ว

    Isn't its bad if uts shear slump it should be true slump right?

  • @rjchhaba8451
    @rjchhaba8451 4 ปีที่แล้ว

    Tnku sir

  • @krishnakumarthakur4933
    @krishnakumarthakur4933 4 ปีที่แล้ว

    Dusra layer kitne time ke badh dalna hey

  • @deepaksaryam
    @deepaksaryam 4 ปีที่แล้ว +1

    इंजीनियर साहब चेहरा तो बता दो।
    जानकारी आपकी फील्ड प्लस praticly बहुत ही अच्छी है।

  • @wonderingcivil8808
    @wonderingcivil8808 4 ปีที่แล้ว +1

    Thanks

  • @sumeetwatwani5391
    @sumeetwatwani5391 4 ปีที่แล้ว +1

    sirji construction joints n its preventions pe video banaiye

    • @shaikmasoodali9552
      @shaikmasoodali9552 ปีที่แล้ว

      construction joint is a design issue and its placement and construction must b detailed by the designer.. if u r a consultant take accurate method of statement frm the contractor and follow up the same on site.. do not invent frm ur side..

  • @CHITRAKAR007
    @CHITRAKAR007 4 ปีที่แล้ว

    Thank You dada

  • @errajkeshprasad143
    @errajkeshprasad143 4 ปีที่แล้ว

    Thanks Sir

  • @kawaldeenkhan786goripathan3
    @kawaldeenkhan786goripathan3 4 ปีที่แล้ว +1

    Sir mudcrete k uper ak video bnao please

  • @Keyboardguruji
    @Keyboardguruji 4 ปีที่แล้ว +1

    what is flow table test??
    for which concreting it can be used

  • @aamirberiwala2196
    @aamirberiwala2196 4 ปีที่แล้ว +3

    Kya aap mujhe bata sakte hai ki slump test ka revision kisme aaya hai....?

  • @mdramiz6404
    @mdramiz6404 4 ปีที่แล้ว

    Dada ratio kitna diya

  • @s.rdhiman3547
    @s.rdhiman3547 4 ปีที่แล้ว

    sir mq kya hota describe krna plzz

  • @rahulpandey-wu3ho
    @rahulpandey-wu3ho 4 ปีที่แล้ว

    Plaster ki thickness kaise measure kaise karte h or dampness kaise control hota h iske upar ek video bna do

  • @Amitkumar-cu2pk
    @Amitkumar-cu2pk 4 ปีที่แล้ว +4

    Sir slump me 25 bar tamp karte h

  • @palashurkude8853
    @palashurkude8853 4 ปีที่แล้ว +1

    What is nito bond and cold joint ? Please explain

    • @kailashkatyal6152
      @kailashkatyal6152 4 ปีที่แล้ว

      Nito bond chemical h jo help krta h old conc.ko new conc. me bond bnane k liye
      Cold joint aata h jb conc.ki ek layer set hojay or bad me dusri layer dalte h

  • @girishkumarpradhanpradhan7919
    @girishkumarpradhanpradhan7919 4 ปีที่แล้ว +1

    site engineer job is very difficult in private companies because engineer have to work minimum 12 hrs or more time duty per Day. this engineer job is very difficult & life risky job compared to other job such as software engineer job , marketing job.

    • @shaikmasoodali9552
      @shaikmasoodali9552 ปีที่แล้ว

      it is a time consuming job but every job comes with pros and cons, u must love ur job and perform the best possible way.. construction work is tough when compared to office jobs, u face not just the climate and rough working condition but also deal with a lot of thieves.

  • @suryakantray8533
    @suryakantray8533 4 ปีที่แล้ว

    Slump test ka is code kya hei new revision ka

  • @shakirkhan
    @shakirkhan 4 ปีที่แล้ว

    Sir 1 set/sample cube means 3 cube not 6 cube after 50 cu.m

  • @minhajulislam4336
    @minhajulislam4336 4 ปีที่แล้ว +2

    If I am not wrong slump filled in 25 strokes.

  • @radhyesingh4054
    @radhyesingh4054 4 ปีที่แล้ว

    M25 grade concrete mai.
    10mm rodi best hai yaa 20 mm

  • @ramsahayayodhya436
    @ramsahayayodhya436 4 ปีที่แล้ว +2

    Sir aapki company me job kaise milegi.
    Civil engineering se diploma kiya hu.

  • @divyadighole3741
    @divyadighole3741 4 ปีที่แล้ว

    सर हमने जमिन के निचे के कालम है ऊसपर तिन दिन पाणी डाला और मिट्टी से भर दिया मिट्टीपर पाणी डाला लेकीन पाणी कम डालते रहे बिस दिन पाच फिट कालम जमिन के निचे है ऊसमेसे तिन फिट जमिन के निचे मिट्टी गिल्ली हूई और दोफिट निचे कालम के पास कि मिट्टी गिल्ली नही हूई तो कालम का बिना पाणी वाला दोफिट हिस्सा कमजोर होगा क्या

  • @kailashkushwaha6955
    @kailashkushwaha6955 4 ปีที่แล้ว +8

    Sir slab casting k time cube test kra rhe ho aap iska Kya fayda hai ?
    1% Sample fail ho gya to Kya hoga slab ka

    • @IntekhabAlam-z9x
      @IntekhabAlam-z9x 4 ปีที่แล้ว

      Iska ye fayada hai ki Concrte ki quality pata chalta hai ki use karne layak hai ki nhi aur colpse to nhi hua hai..

    • @shaikmasoodali9552
      @shaikmasoodali9552 ปีที่แล้ว

      we must do it, if the test fails we check the design for achieved strength, if tht fails too we can check if we can take remedial measures, if it is not possible, we can demolish the construction and redo it.. the testing is very important

  • @shashanksinghthakur4076
    @shashanksinghthakur4076 4 ปีที่แล้ว

    Sir!
    what is the nitot_bond which helps for construction joint ?

    • @AbidHussain-ip9jv
      @AbidHussain-ip9jv 4 ปีที่แล้ว

      It's a type of bonding material which helps to avoid the construction joint when casting huge quantity of concrete.

  • @rahulmishra1629
    @rahulmishra1629 4 ปีที่แล้ว

    Slump testing ka new updates kb aya hai
    Number of 3rd layers of concrete

  • @PritamQA
    @PritamQA 4 ปีที่แล้ว +1

    Agar cube samples fail ho gaye test me, toh kya karna? Slab, beam, column to already cast ho gaya hai??

    • @lifechangesmoments2735
      @lifechangesmoments2735 4 ปีที่แล้ว

      Uske baad hammer test,core cutting test hota hai

    • @PritamQA
      @PritamQA 4 ปีที่แล้ว

      @@lifechangesmoments2735 Jab utni strength hi nahi mil rahi to structure fail hoga na.. Uske baad hammer test bhi almost fail hi hoga

    • @manishmishra7362
      @manishmishra7362 4 ปีที่แล้ว

      This is fcking useless like using medicine after death lol... Such test need to be done before casting... Or testing of aggregate quality before using is better so no need of cube test compulsorily...

    • @Abhiyadav56114
      @Abhiyadav56114 4 ปีที่แล้ว

      Agar fail ho gya ,to structure design engineer k pass ye case jata h ,or total strength ka 75% aana hi chahiye , ,agar nhi aaya to fail ho jata h

    • @shaikmasoodali9552
      @shaikmasoodali9552 ปีที่แล้ว

      ye galti nahi karni.. u must get 7 days result to cast beam and slab.. if ur samples for columns have failed, make remedial measures like jacketing for concrete columns, if not demolish all columns.. beam aur slab me agar defective concete hogai ho toh designer se recommendation lo k ye kam strength par bhi perform karsakta hai ya nahi, agar nahi toh demolish the thing.. ther are remedial measure like carbon fibre reinf to tackle issues but applies to certains situations.

  • @divyeshkanani6604
    @divyeshkanani6604 4 ปีที่แล้ว

    In case apna concrete temprature me fail ho gya like jyada ho gya or cum ho gya to concrete me kya krna pdega solution k base pr

    • @dawoodjamshaid9146
      @dawoodjamshaid9146 4 ปีที่แล้ว

      for this purpose we do concreting mostly at night time when temperature is low or we can mix cold water in concrete instead of normal temperature... answering as a student

  • @shahriarfardin777
    @shahriarfardin777 4 ปีที่แล้ว

    To be honest everyone is using same wc ration and mix ratio so its giving same results,loads are also Same every where

  • @vishalkumar-pk2bj
    @vishalkumar-pk2bj 4 ปีที่แล้ว

    Pls sir concrete temperature measurements tools ka name batae

    • @shaikmasoodali9552
      @shaikmasoodali9552 ปีที่แล้ว

      boss its a simple thermometer. electronic hota hai..

  • @amitayade301989
    @amitayade301989 4 ปีที่แล้ว +2

    1st of all where is PPE???? Of labours

  • @asgharbadshah5592
    @asgharbadshah5592 4 ปีที่แล้ว

    Slump value kitni hone chahiye normaly aur kitni nahi honi chahiye. ? Like in this video slump value comes out to be 160mm.

    • @shaikmasoodali9552
      @shaikmasoodali9552 ปีที่แล้ว

      slump value is basically decided by the site engrs, some engrs allow upto 20cm slump when superplasticizer is used, slump as suggested by code may result in harsh concrete at site which will make it very tought for working. the batch plant must b made aware in case of high slump requirement, engr can go to the plant and test and check the concrete behaviour with various admixtures if necessary..
      for beams and slabs 15cm slump
      columns 17-18cm would b more than sufficient, all those engrs who say we need lesser slump with be seen doing 🤦‍♂️when the columns end up with honeycombs..

    • @shaikmasoodali9552
      @shaikmasoodali9552 ปีที่แล้ว

      keep checking the quality, never let them mix water on site and use only superplasticizer to increase workability, 2-3ltrs of superplasticizer wont affect the concrete strength, can take samples after adding to chk if ther is any affect

  • @sasoriakatsuki65
    @sasoriakatsuki65 4 ปีที่แล้ว +1

    Need to bond kya hota hai?

  • @GauravSingh-ww5xu
    @GauravSingh-ww5xu 4 ปีที่แล้ว

    Pls name a revised IS Code of Slump test

  • @srikarbandekar4055
    @srikarbandekar4055 4 ปีที่แล้ว

    What if the concrete cube doesn't gains it's required strength on 7th n 28th day?

    • @shaikmasoodali9552
      @shaikmasoodali9552 ปีที่แล้ว

      whatever strength is achieved is passed on to the designer, he will verify the design with lower comcrete strength if he approves the design with lower strength then we can continue our work, in case he doesn't approve then the work must b demolished and must be redone.. dont take such steps in construction of columns, if the test fails go ahead and demolish the column, do not wait for a catastrophe to occur.

  • @GodLRdx17
    @GodLRdx17 4 ปีที่แล้ว

    Are sir video ki length ki fikar na karo..... 🙂❣️

  • @sadiqaparween8213
    @sadiqaparween8213 4 ปีที่แล้ว

    Bhai mujhe ya site mein kam karwane ke liye kam milega
    Mein ek labour supplier hun plz hame bataye

  • @sameerbabu1856
    @sameerbabu1856 3 ปีที่แล้ว

    🙏

  • @Parimahishan
    @Parimahishan 4 ปีที่แล้ว

    Temperature check machine ka naam kya hai sir

  • @sudipanbhattacharjee382
    @sudipanbhattacharjee382 4 ปีที่แล้ว

    Shez hammering more then 40 times..please check

  • @sanketmane343
    @sanketmane343 4 ปีที่แล้ว

    I am diploma student my branch is civil engineer

  • @djsamod
    @djsamod 4 ปีที่แล้ว

    35 or 25 stock karna hota?

  • @sagarshinde9827
    @sagarshinde9827 4 ปีที่แล้ว

    Slume is not filled as per is code

  • @gulamnavi310
    @gulamnavi310 4 ปีที่แล้ว

    Slump test trawel use nahe krte he dadda

  • @yadvendrakumarsaini9088
    @yadvendrakumarsaini9088 4 ปีที่แล้ว

    Are bhai ye tempping jyada kr rhi h

  • @lifestyle-ns1zo
    @lifestyle-ns1zo 4 ปีที่แล้ว

    Foundaion is column then load bearing structure coment

  • @rfbp9104
    @rfbp9104 4 ปีที่แล้ว

    Worker and staff are not wear the PPS in your video , please trained your Staff....

  • @electogaming9037
    @electogaming9037 4 ปีที่แล้ว

    Ohh yeh To marwadi wali college hai

  • @komalrawat3719
    @komalrawat3719 4 ปีที่แล้ว

    Slump test me 25 stock marte hai

  • @kalyankarsandeepkumar3530
    @kalyankarsandeepkumar3530 3 ปีที่แล้ว

    😍🙏❣️

  • @rajeevchouhan1
    @rajeevchouhan1 4 ปีที่แล้ว

    vibrator i guess😕
    not Bibrator
    rest was 👍

  • @amolsharma3796
    @amolsharma3796 4 ปีที่แล้ว

    35 stock ya 25

  • @predatorgaming895
    @predatorgaming895 4 ปีที่แล้ว

    Why can't you do in English 🙄🙄🙄

  • @rasmiranjansatapathy9307
    @rasmiranjansatapathy9307 4 ปีที่แล้ว

    Slab me electrical pipe install bahut zada hai Meri hisab se

  • @ankitagrawal6378
    @ankitagrawal6378 4 ปีที่แล้ว

    BHAI SITE ENGG FRESHER KI SALARY KYA HOTI HAI CITY ME? B.TECH

  • @anshikaverma7919
    @anshikaverma7919 4 ปีที่แล้ว

    sexy

  • @mohitdharve173
    @mohitdharve173 4 ปีที่แล้ว

    Sar building construction Mein Koi requirement Hai To bataiye sir ji 1 Sal Ka experience a supervisor ,9691360231

  • @phadiboys2427
    @phadiboys2427 4 ปีที่แล้ว

    Nice sir