I had a machine that wanted to regen every 1.5 hours. Checked over all electrical components and intake and exhaust clamps and found nothing. Replaced the injectors and found that the last guy who did injectors didn’t fish the sealing washer out, so 3 of the 6 injectors had 2 sealing washers, therefore the injectors were sitting twice as high in the cups as they were supposed to. Not allowing the o-rings to seat and dumping raw fuel into the cylinder at all times.
I had a machine that wanted to regen every 1.5 hours. Checked over all electrical components and intake and exhaust clamps and found nothing. Replaced the injectors and found that the last guy who did injectors didn’t fish the sealing washer out, so 3 of the 6 injectors had 2 sealing washers, therefore the injectors were sitting twice as high in the cups as they were supposed to. Not allowing the o-rings to seat and dumping raw fuel into the cylinder at all times.