Do I need a thermal expansion tank? - Let's do an experiment!

แชร์
ฝัง
  • เผยแพร่เมื่อ 4 ต.ค. 2024

ความคิดเห็น • 2.1K

  • @krisssilco
    @krisssilco ปีที่แล้ว +347

    When learning about this expansion tank, there shouldn't be any other video than this one. You showed thermal expansion visually and with a pressure gauge. You showed us the bladder inside and how it works with an increase in pressure. You can't show any more about this topic. Nice job man

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว +8

      Thanks!

    • @noelburke6224
      @noelburke6224 ปีที่แล้ว +8

      You can show the calculations used to get the proper sizes off the expansion tank's and also explain the different precharge pressure for different systems

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว +4

      @@noelburke6224 watts has a calculator just for that as well!
      www.watts.com/resources/planning/etp

    • @tmosest
      @tmosest ปีที่แล้ว +5

      For real. This video is amazing! Thanks for sharing your knowledge!

    • @waldrobfarms3946
      @waldrobfarms3946 ปีที่แล้ว +2

      Agreed

  • @alphabears6342
    @alphabears6342 6 หลายเดือนก่อน +16

    This is one of the best documentary on expansion tank.

  • @Domme857
    @Domme857 ปีที่แล้ว +91

    I bought this water heater th-cam.com/users/postUgkx8G49mV71sAzUl9shXyLW-r3XgHH9EVh1 for use in my bus conversion. I installed it under my kitchen sink and it is fed by a high efficiency on-demand LP water heater. It is both a backup hot water source as well as a water saving device since we have hot water on demand rather than having to wait for the gas on demand water heater to finish its ignition cycle. I decided on this water heater due to the fact that it only draws 1300watts when it's ON instead of the 1500 watts that most Water heaters this size draw. In an RV a couple hundred watts can be a big deal. With very low standby losses, I don't have to worry about excessive power consumption. When propane is not available for our gas water heater, in conjunction with our low flow shower head there is enough hot water available to shower, albeit we won't be taking "hotel showers." Also very happy with the recovery rate of this water heater. Granted, it is quite small, but it does exactly what we need it to do.

  • @DYIIdeas
    @DYIIdeas หลายเดือนก่อน +2

    Been in the plumbing industry for 20+ years. The way this video is put together is PERFECT, definitely knows plumbing very well. Just make sure to run video at 1.25 speed so that it feels normal.

    • @SmedleyPlumbing
      @SmedleyPlumbing  หลายเดือนก่อน

      Thanks! Yeah I always crank the speed on these long ones too.

  • @robbynelson3
    @robbynelson3 ปีที่แล้ว +37

    I'm over here wondering why our public schools don't do what you just did. You sir are a legend. Keep it up!!

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว

      I appreciate that!

    • @loktom4068
      @loktom4068 ปีที่แล้ว +3

      The school system is not keeping up with modern times.
      Still teaching Romeo and Juliette as composary courses.
      Go figure.

    • @usethenoodle
      @usethenoodle ปีที่แล้ว +8

      @@loktom4068 Actually now they are teaching critical race theory, gender confusion theory and Marxism.

    • @hoppershelpfulautomotive
      @hoppershelpfulautomotive ปีที่แล้ว +6

      @robbyneleson3 Exactly! Our school system needs to stop making our children feel guilty for not going to college. Forget bringing back trade programs to high school, we should be introducing kids to this type of material in elementary and middle school AND high school. I spent 12 years in the automotive industry, and now work in the hvac & home remodel industry. Both of my school age kids can identify a capacitor, a contactor, and more automotive parts than I care to count. If the schools won't do it, it's up to us to teach our kids everything we know. @Smedley Plumbing - Very awesome and well put together video! keep up the good work.

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว

      @@hoppershelpfulautomotive thanks!

  • @GIGallegosreg
    @GIGallegosreg ปีที่แล้ว +71

    Been in the plumbing industry for 20+ years. The way this video is put together is PERFECT, definitely knows plumbing very well. Just make sure to run video at 1.25 speed so that it feels normal. 😁

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว +2

      Thanks!

    • @larrytheplumber9851
      @larrytheplumber9851 ปีที่แล้ว +2

      😂

    • @shockingguy
      @shockingguy 11 หลายเดือนก่อน +2

      Agreed, even if you’re a newbie this was a little long and drawn out, but an excellent video nonetheless

    • @JoniAntonio
      @JoniAntonio 10 หลายเดือนก่อน +3

      I've watched a ton of videos of people complaining that teachers speak too fast. you can't please everybody...

  • @wm005
    @wm005 ปีที่แล้ว +42

    I am a retired home inspector and never received this type of training. When I came across these tanks I only knew to check the pressure on both the water heater and the tank based on training myself through compairson between different homes. This is an excellent video and a valuable training aid to all...

  • @25kmgb
    @25kmgb 11 หลายเดือนก่อน +52

    This should be a required part of the training every new plumber must receive. You did an outstanding job presenting this information in a way that every home owner, building inspector and tradesman will understand and remember. I’m really impressed!

    • @SmedleyPlumbing
      @SmedleyPlumbing  11 หลายเดือนก่อน

      Thank you! We are pretty proud of this video as well.

    • @Astrnauted
      @Astrnauted 9 หลายเดือนก่อน

      well when youre an actual REAL plumber that went to school anytime in the past 4-10 years its pretty standard to know id even argue earlier than 10 years but thats municipal dependent.

    • @SmedleyPlumbing
      @SmedleyPlumbing  9 หลายเดือนก่อน

      @@Astrnauted no need for hateful comments. Water all trying to share knowledge and learn here.

    • @Astrnauted
      @Astrnauted 9 หลายเดือนก่อน

      @@SmedleyPlumbing lol bud that’s not hateful. Just emphasis on real. Get a grip

    • @tellsthetruth894
      @tellsthetruth894 4 หลายเดือนก่อน

      Thank you very much for this valuable and educational video. Questions: What size expansion tank is needed for the 40 gal, 50 gal, and a 75 gal water heater tank sizes. The sizes I noted that are available on the market are like 2 gal and 4 gal. I've had a 75 gal tank heater for over 20 years and never have had an expansion tank, nor to my knowledge, had the pressure relief valve to open on its own to relieve the pressure. Would you kindly comment on the best path forward that i should pursue. Another question: Where on the water heater tank would you add a temp gauge if these gauges are available on the market. My old water heater doesn't come with either a pressure or Temp gauge, unfortunately. Thank you

  • @jefflewis9675
    @jefflewis9675 หลายเดือนก่อน +2

    I don't think there could be a better, more practical informational video on expansion tanks explaining the how, what, and whys of this plumbing device. Bravo, sir!

  • @billallen275
    @billallen275 ปีที่แล้ว +65

    What a GREAT demonstration! You should mention that it is code in many locations to put those in. This is because municipalities are putting in backflow preventers at residential meters and the water has nowhere to go. With no backflow prevention the water simply goes back out into the main. We know that, but people that don't know what expansion tanks are don't.

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว +6

      Correct. Problem is nobody knows if there are checks in the system. If they aren't blindly required by the local code, then it's best to perform a pressure test and monitor pressure through the heating cycle. Code doesn't technically require them but local municipalities sometimes do. Code just requires that thermal expansion must be controlled when it's present.

    • @billallen275
      @billallen275 ปีที่แล้ว +1

      @@SmedleyPlumbing it's probably the safest option to expect at least a Dual Check valve. Cannot be tested, and I'm seeing lots of them in default meter installations in many locations. Some meters have them built in to the meter assembly itself, or put in with the meter.
      Not having one with a check valve will damage the system and the check valve itself. Over back-pressures the check disks. Thanks 😊👍

    • @johnpeace971
      @johnpeace971 ปีที่แล้ว +2

      Why would it go back into the main? I'd just expect my house to have really good water pressure

    • @brianreinhardt4050
      @brianreinhardt4050 11 หลายเดือนก่อน +4

      @@johnpeace971
      In a 3/4" line, how much water VOLUME from the street to the water tank would TRULY backflow into the system when pressurized? I mean seriously this is a farce. The water that actually did go back into the system would never have left it in the first place.

    • @512dude
      @512dude 8 หลายเดือนก่อน

      @@brianreinhardt4050 He demonstrated in the video that for his given temperature rise, about a quart of water is displaced. Assuming negligible expansion of the system you can assume that the volume of water that would backflow is roughly a bit less than that quart, that backflow would only start to flow once the system pressure was greater than the incoming main pressure.

  • @schmitty99
    @schmitty99 9 หลายเดือนก่อน +11

    HVAC guy here. This video was awesome. Thank you!

  • @tommartinez62
    @tommartinez62 10 หลายเดือนก่อน +14

    As a retired plumber of 48 years, I used to be puzzled at how many people did not know basic physics. Now I realize my Earth Science teacher in 9th grade was a jewel, Thanks Mr. Rice, Central High, Cheyenne Wyo. 1969

    • @SmedleyPlumbing
      @SmedleyPlumbing  10 หลายเดือนก่อน +1

      Comes in handy sometimes!

    • @bojanglesobrien6883
      @bojanglesobrien6883 7 หลายเดือนก่อน

      Awareness principle, it blows my mind that people don’t naturally understand the things I regularly look at. Then, I remind myself that I don’t know jack shit about computers compared to every single person I know.

    • @tommartinez62
      @tommartinez62 7 หลายเดือนก่อน

      @@bojanglesobrien6883 True, though one is actually the world around us, we feel touch and see from birth. The other is a man made object

  • @bobfrancis4289
    @bobfrancis4289 4 หลายเดือนก่อน +3

    Plumbing contractor for 40 years, always knew and respected thermal expansion and your video illustrated it perfectly! Thanks so much! Also, came from your other video where you compared box store water heater to pro grade. I was one of those who thought they were the same.... Not anymore! Great educational videos that are extremely well done!!! You Rock!!

  • @N9IWJ
    @N9IWJ หลายเดือนก่อน +1

    It's now code, required, in most areas
    Thanks for the video
    You sure do know what your talking about

  • @davedfran6082
    @davedfran6082 27 วันที่ผ่านมา +1

    The method you used to figure out how much is still in the tank is genius! Love your videos ❤

  • @adroper62
    @adroper62 หลายเดือนก่อน +3

    Phenomenal, detailed, and informative presentation. We are in the process of replacing our 17-year-old water heater, and I was skeptical of the need for an expansion tank since the purpose of the T&P valve is to relieve pressure. Our electric water heater typically runs 6-10 minutes cycles 4-5 times daily (Phoenix, AZ). I have never seen any evidence the pressure relief system has tripped on due to excessive pressure. The relief drain pipe runs outside of our house, and I haven't seen any water coming from it since we purchased the home.
    Thanks to this video, I see the benefit of having the expansion tank as the primary pressure overload manager, so we will add one to the installation.

  • @sailthebigorb7174
    @sailthebigorb7174 11 หลายเดือนก่อน +9

    No one could have done a more thorough and effective job of explaining all this as you did. I learned so much. Great job!

  • @candace2206
    @candace2206 6 หลายเดือนก่อน +3

    Thank you so much for posting this video. About two years ago, our small town replaced the old water meters. Immediately after this, we noticed water on the floor of our basement at the bottom of our tank water heater, clearly from the PRV. We were having to empty a large plastic Folger's coffee container every 2-3 days. We were also experiencing a short blast of high pressure water whenever we would turn on a faucet. Uneducated about this particular area of plumbing, I was still smart enough to know that none of this was right....at all. It took several days of internet investigation and calls to Town Hall to find out that the new meters changed our water supply to a closed system. Long story short.....I have a Watts thermal expansion tank (honestly...because that's the label on your tanks...lol) arriving this weekend. And I've already installed a secondary inline PRV. I just didn't trust the PRV on the tank for some reason. Again, we cannot thank you enough! You can't imagine the stress you have relieved in this household. This video should be the Gold Standard for all educational videos posted! You truly did a fantastic job. We have subscribed and clicked the bell......you've got us for life!! ❤😊❤

    • @SmedleyPlumbing
      @SmedleyPlumbing  6 หลายเดือนก่อน

      Boom! That's why we do this! Glad we could help!

  • @theberrybest
    @theberrybest ปีที่แล้ว +1

    I've been a plumber for 40+ years. I think you nailed it.

  • @jimlaufenberg6428
    @jimlaufenberg6428 18 วันที่ผ่านมา +1

    excellent brief on the expansion and working components...best i have seen you could be the plumbing professor

  • @chrisriggs6267
    @chrisriggs6267 ปีที่แล้ว +14

    Can you learn everything about everything then teach it all to us just like this? Great job, appreciate the time and effort you put in this video for us.

  • @plumbersteve
    @plumbersteve ปีที่แล้ว +6

    I'm in St. Louis. Customers, especially older ones, are all so skeptical of "that blue ball thing that you put on my water heater". I've developed a pretty good understanding of thermal expansion and I feel like I'm able to explain it pretty well, but this video is a game changer. Thanks for putting in the time.

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว +1

      That's exactly why we made the video! Put this info to use!

  • @jorseirer
    @jorseirer ปีที่แล้ว +4

    This might be the best home systems video I’ve ever seen. Amazing demonstration, thank you.

  • @georgewelker853
    @georgewelker853 ปีที่แล้ว +2

    Thank You for nerding out on this! People don’t understand this stuff but definitely need to understand that

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว

      It's very important. Especially if you're trying to make these sales to customers.

  • @andymurray8007
    @andymurray8007 9 หลายเดือนก่อน +1

    I wish my plumber had watched this. Instead I put up with 13 yrs of a dripping T/P valve, then finally installed one myself. Thanks for educating us all!

    • @SmedleyPlumbing
      @SmedleyPlumbing  9 หลายเดือนก่อน

      Sorry to hear that. Glad you fixed it though!

  • @DanielinLaTuna
    @DanielinLaTuna ปีที่แล้ว +7

    Fascinating; thanks for sharing. I didn’t know about the function of the relief tank - I thought it was to prevent water hammer.
    Originally I didn’t have the pressure tank in my system. Last time I replaced the water heater, the plumber took it upon himself to add the pressure tank. Now I see he was a competent technician who kept up with best industry practice.

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว +2

      Exactly! They do help with hammer as well!

  • @GarreTTTurncoaT
    @GarreTTTurncoaT 10 หลายเดือนก่อน +5

    I truly appreciate the amount of time and effort put into this video, setting up the visuals and also editing it all together.. with incredible quality both audio and video. Very hard to come by videos this great today.

  • @bernieshort6311
    @bernieshort6311 ปีที่แล้ว +9

    I am a retired marine engineer and was aware of how an expansion tank works because we had similar but much larger systems on boar made by a company called Newpress. I watched your video just to see how good an explanation you were going to give an I must admit you did an excellent job of explaining how the system works and why you need expansion tanks in a sealed system. The only thing I would add, if I may, is the reason why your expansion tank doesn’t collapse like the water bottle did. Thanks that was a very well explained tutorial with excellent demonstrations. Thank you.

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว +1

      Yeah the water heaters are never subjected to negative pressure. Plus they are more durable than a plastic bottle.

  • @光文朱
    @光文朱 7 หลายเดือนก่อน +1

    This is the most lifesome lesson that I have ever learned in the industry! Bravo !

  • @russell7489
    @russell7489 7 หลายเดือนก่อน +1

    Great post Great comments. Having lived with pumped water my life, every system has an expansion tank built in the pump pressure tank, usually 40 gal but I use a 60 gal cause bigger is better. Less swing, less pump cycles, less stress cycles...

    • @SmedleyPlumbing
      @SmedleyPlumbing  7 หลายเดือนก่อน

      One big perk of being on a well!

  • @rzh3443
    @rzh3443 ปีที่แล้ว +9

    I think you about covered every angle on this ! I installed a pressure reducing valve on our system in addition to the expansion tank. The PRV definitely closes to system but I believe very essential to reduce pressure to fixtures to 50 psi max. They will last longer. Our input pressure is over 80 psi at the meter . I also think that the expansion tank may prolong the tank life by retinue the amount of expansion/contraction inside it. For those who think 80 plus psi is nice, be aware that most well pumps only deliver within a 30-50 psi range.

  • @irgtk
    @irgtk 10 หลายเดือนก่อน +3

    I am on a municipal water system with no backflow preventer installed. Now I know why an expansion tank was not installed on my water system.👍🏻

    • @SmedleyPlumbing
      @SmedleyPlumbing  10 หลายเดือนก่อน +1

      Quite possibly. It's always good to test with a pressure gauge during a heat cycle of the water heater just to make sure.

  • @latissue8887
    @latissue8887 11 หลายเดือนก่อน +3

    Many thanks. I'm a landlord of 20 properties and never thought it was important to spend the extra for an expansion tank. Guess I have work todo installing some expansion tanks! Very good video. Explained well.

    • @SmedleyPlumbing
      @SmedleyPlumbing  11 หลายเดือนก่อน

      Glad I could help

    • @jaykoerner
      @jaykoerner 9 หลายเดือนก่อน +1

      Depends on the local regulations(some require backflow preventors on all properties, some on just new, and some require install during renovation) and whether the properties have backflow preventors if on municipal water, or if on well water if it's one with a check valve to keep prime and no pressure tank(really uncommon)
      If your water can go backwards and pass pressure past the supply then a expansion tank will really only help mitigate possible freezing issues where ice physically plugs the pipe and sends pressure into the house that way

  • @guianders
    @guianders 8 หลายเดือนก่อน +2

    I've been in the hvac business for 20 yrs and had boilers with hot water element fail every 2 yrs leak and now it makes perfect sense thank you for your detailed info and dedication 😮

  • @markkriedeman7188
    @markkriedeman7188 8 หลายเดือนก่อน +1

    Perfect interpretation of how important these tanks truly are.

  • @Th3Su8
    @Th3Su8 ปีที่แล้ว +3

    Great explanation of the expansion tank and why it is needed. When I bought my 60 year old house a few years ago I installed a whole house filter system. Along with the filters I put in a PRV, which my house did not have originally. I found that the water pressure coming into my house was around 120 - 125 psi. I set the PRV to 60 psi and thought everything was good. A few days later my filters were leaking and the pressure had increased back to 120 psi after the filters. I thought the PRV had gone bad and the mfg sent me a replacement, the same thing happened. Then I did some digging around and figured out my problem was there was never an expansion tank installed in my home. I put one in and have since never had any issues. I recently replaced my 20 year old water heater in this house and found that the T&P valve was non functional. You would think that a home inspector would test these things when you pay them to check the home for issues before buying it.

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว

      There are a lot of things that the everyday person would think or hope a home inspector would check. But unfortunately they aren't as thorough as we would like them to be once we find something wrong with the home.

  • @andrewsimmons8157
    @andrewsimmons8157 ปีที่แล้ว +4

    Wasn't sure if I was going to watch the whole video but I am so glad I did. Best demonstration video in the history of ever! Thank you so much for the break down of everything. Amazing Job!!

  • @berts4877
    @berts4877 ปีที่แล้ว +3

    Great video. I never had thermal expansion tanks on homes I owned or lived in near Chicago. I have one in my home near Dallas and had to replace it this past weekend when the old one sprung a leak. I enjoyed getting an understanding of its purpose.

  • @Rews-fish-shed
    @Rews-fish-shed 5 หลายเดือนก่อน +1

    Hopefully done a good job he says
    This is a definitive video for the explanation of the use and need for a hot water expansion tank.
    Thank you

  • @cptsb63
    @cptsb63 28 วันที่ผ่านมา +1

    Thanks a lot for spending your time and resource to improve our knowledge of the water thermal expansion. You have done a phenomenal job in plumbing expansion knowledge. Keep up the good jobs. Thank you.

  • @ricdonato4328
    @ricdonato4328 ปีที่แล้ว +3

    Outstanding explanation, thank you. Being from the old school when we were informed for the need an expansion tank it was perplexing. What are and for, what reason do we now needed one when for decades there were not such a thing. They told us "it is now code" without any further explanation. Again, thank you for your video.
    In your next video mount the camera. It is unnerving watching a video with the camera bouncing around, where do we focus? Oh, please remove the background music, it is very distracting and annoying. It is beyond me why TH-cam content creators think it cool-cute-necessary, having music playing over their voice. We came to hear you, not fight the music. Many folks have hearing difficulties, thus when we attempt to hear the spoken works and there is music as well, we cannot turn up the volume without turning up the volume of the music. In a word frustrating. To understand what you are saying what we must do is turn on the CC. Hope this makes sense.

  • @jeffreysmith2223
    @jeffreysmith2223 ปีที่แล้ว +21

    One other thing you should add to your discussion is the potential effect of added pressure to any weak pipe connection in the system, for instance a buried elbow hidden inside a living space wall. For anyone still using Polybutylene pipes, a thermal expansion tank could mean significant added life to their water supply system. I did an in depth study of thermal expansion tanks a few years ago and I now have them both at my home and my vacation home as well. Thanks for the video, the visualization of the water expansion and the baloon in the bottle were highly instructive, great lateral thinking on your part.

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว +4

      Thanks. We could go on for a while on the damages thermal expansion might cause. Or next video will highlight the worst case scenario....🤯

  • @davemeise2192
    @davemeise2192 ปีที่แล้ว +8

    This has been an excellent video. Great explanations and demonstrations. I have always wondered why expansion tanks became common on plumbing systems. Well done!

  • @pete3882
    @pete3882 3 หลายเดือนก่อน +1

    Excellent video. Thanks. I added a check vavle to my main, city water and kept getting high pressure warnings from my moen flo, every couple of days. This explanation really helps. At first i thought it was the city but after placing a gage before the check i realized its the system itself, not the city. I have an 80 gal super store. So i will be adding probable a large expansion tank.

  • @rushd45
    @rushd45 11 หลายเดือนก่อน +2

    Loved your comment about AZ cold water temp... I'm in Tucson and during this summer (2023) there were a couple weeks where the cold water was warm/hot enough so that my showers didn't need any hot water...

    • @SmedleyPlumbing
      @SmedleyPlumbing  11 หลายเดือนก่อน

      Yep. You get hot or hotter. Lol

  • @ph33lix
    @ph33lix ปีที่แล้ว +5

    Fantastic and comprehensive look at current plumbing best-practices. Definitely learned a thing or two for my home. Bravo!

  • @FA-44
    @FA-44 ปีที่แล้ว +6

    Absolutely awesome video. Many engineering courses teach this science, but you gave us a great visualization of this application in the practical world and you also demonstrated the things that can go wrong if you don’t address it properly with components like expansion tanks. You also showed what negative pressure can do to a thin walled cylinder (like a water heater tank) when negative line pressure / vacuum collapsed the plastic bottle. I know in some older cities in Massachusetts, you need a vacuum break on your hot water heater tank. As I’m told, if a fire truck starts sucking water from a nearby hydrant and you do not have a water line check valve in your home, then it could result in the collapse of your hot water heater tank, so awesome demonstration. Thank you for pulling this together.

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว

      Yeah I've seen pics of collapsed water heaters in high rise buildings that didn't have a vacuum breaker.

    • @stevepreskitt283
      @stevepreskitt283 หลายเดือนก่อน

      Most water heaters today have a hole in the dip tube that will act as a vacuum breaker if the tank is subjected to negative pressure, but it never hurts to have a separate one on the cold water supply.

  • @scruples671
    @scruples671 9 หลายเดือนก่อน +3

    Another big thing to know is whether your incoming water to your house has a one way check valve at the water meter. If there is one you are defiently going to need an expansion tank. In my area there is no check valves for the incoming water supply. So an expansion tank is not required. Great demonstration.

    • @SmedleyPlumbing
      @SmedleyPlumbing  9 หลายเดือนก่อน +1

      Yep. Best way to test for the presence on a check valve is with a pressure gauge.

    • @dubmob151
      @dubmob151 9 หลายเดือนก่อน +1

      Isn't a check valve required to prevent potential contamination of the municipal water supply?

    • @SmedleyPlumbing
      @SmedleyPlumbing  9 หลายเดือนก่อน

      @@dubmob151 yes. You're exactly right.

    • @Sean_y4k2l5
      @Sean_y4k2l5 9 หลายเดือนก่อน +1

      also if you are pumping from a well or cistern... in that case there is already a large expansion tank, so putting another little one on the heater is redundant... right?

    • @SmedleyPlumbing
      @SmedleyPlumbing  9 หลายเดือนก่อน +1

      @@Sean_y4k2l5 correct. If you're on a well or cistern, your bladder tank also serves as an expansion tank.

  • @johnwerner9695
    @johnwerner9695 10 หลายเดือนก่อน +1

    I'm renting a house the plumber they sent out didn't even know how to test the system I found out that he's a apprentice plumber and works in rough install. Thank you very much for the effort. You are keeping me at JACK of all trades

    • @SmedleyPlumbing
      @SmedleyPlumbing  10 หลายเดือนก่อน +1

      Training other plumbers was taken into consideration when we created this video.

  • @CaptK-py8rq
    @CaptK-py8rq 10 หลายเดือนก่อน +2

    One of the best no-bs demonstrations I've watched on youtube to date! Very well done, thank you!

  • @williamwiseman5083
    @williamwiseman5083 ปีที่แล้ว +3

    Wow! By far the best video on expansion tanks on the web!!! Great job thank you very much for doing this and sharing

  • @miked3764
    @miked3764 ปีที่แล้ว +3

    Seeing the demonstrations helps me understand the concept tremendously! Nice job 👍

  • @jj-dl5wd
    @jj-dl5wd ปีที่แล้ว +3

    Thanks for taking your time to show us this. Excellent work!

  • @dembandure891
    @dembandure891 10 หลายเดือนก่อน +2

    Greetings from the Gambia🇬🇲. Im a plumber in my 5th year apprenticeship. You can follow nice meeting my fellow plumbers😊❤

    • @SmedleyPlumbing
      @SmedleyPlumbing  10 หลายเดือนก่อน +1

      Welcome!

    • @dembandure891
      @dembandure891 10 หลายเดือนก่อน

      @@SmedleyPlumbing thanks. Nice works you got there I really appreciate your efforts

  • @kevinh9262
    @kevinh9262 ปีที่แล้ว +1

    If you are responsible for the plumbing setup in your video... 👏👏👏! Beautifully done!

  • @0ddSavant
    @0ddSavant ปีที่แล้ว +6

    I used to live in the Midwest, now I’m in East Phoenix. Almost all residential water distribution is above ground out here. I can remember when I’d only been out here a few months, I was home in the middle of the day and tried to take a shower when it was ~115° outside.
    On full cold the water was just shy of scalding, 120°+. It was at the extreme upper limit of tolerable for me - and then only for exceedingly short periods.
    So yeah, no doing laundry or showering in the middle of the day unless you’ve got some MacGyver projects already in flight.
    Another piece of trivia showing Arizona is not a suitable environment for humans: there’s a phenomenon of people in motorcycle/traffic accidents, or pedestrians struck by vehicles, wherein the victim ends up on the blacktop and suffering more serious injuries from having laid or fallen on the ground than from the collision which threw them to the ground.
    Stay where there’s trees & grass & seasons & most of the people on the interstate aren’t from LA. Where using your turn signal isn’t considered a sign of weakness. I’ve wandered off topic and into a nostalgic rant, my apologies.
    Enjoy your content.
    Cheers!

  • @stevebabiak6997
    @stevebabiak6997 ปีที่แล้ว +4

    To add a few things that might help those who aren’t quite aware of symptoms and causes …
    First, don’t do testing like that in your own home. Learn by watching the video, not by being a copycat.
    Residential plumbing codes in most jurisdictions in the USA have an upper limit of 80 PSI as the maximum pressure to feed plumbing fixtures. In many places the incoming municipal water will have a pressure well above that (my house had 105 PSI when I last measured it), so a pressure reducing valve (PRV) is installed just past the water meter. As far as I know, all PRVs for residential water prevent back flow to the water meter; and many water meters also prevent back flow into the water service lines. So expanded water isn’t able to flow back into the water service lines in most cases.
    So where does it go if there is no expansion tank and the T&P isn’t dripping?
    Old ball float toilet valves were good for letting the expanded water flow through them and then down the overflow tube ;)
    Old faucets with washers and seats would often have a wear point that would let the expanded water drip through.
    So it’s quite possible that a dripping faucet or running toilet is an indicator that you need an expansion tank.

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว +1

      Yes sir. Some prv's allow for back flow but the interior pressure must exceed the incoming pressure before it can happen. In those situations, you're right back to the elevated pressure you were trying to prevent by adding the PRV.

  • @slomotrainwreck
    @slomotrainwreck ปีที่แล้ว +4

    I've taught apprentices in the past and your presentation is excellent! I have one tip and one question:
    TIP - I've used something called a "bottle bushing", it's a plastic adapter bushing that you glue into a PVC socket and it uses an O-ring to seal the joint between the bushing and bottle, I've not used mine under system pressure but for my use it's been leak free. A simple google search will take you to the website where I got mine from.
    QUESTION - Can you mount the expansion tank above the system piping (essentially up-side down) to help with system drain down i.e. when closing and winterizing a cottage for the winter?

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว +3

      Thanks for the tip!
      Yes expansion tanks can be installed in any direction. Some have commented on here that they prefer installing them on the top of the pipe so sediment doesn't build up in them.

  • @thomasgersitz338
    @thomasgersitz338 ปีที่แล้ว +2

    Really explained the purpose of a thermal expansion tank. Fine job.

  • @berkscatbill5582
    @berkscatbill5582 6 หลายเดือนก่อน +1

    Good show. I have an old house with many old copper connections throughout. I just replaced my 1985, A.O. Smith gas 50 gal with the same make and size. What a difference this new one makes.
    Even though I have an open system ( no backflow or check valve at the meter) your video has convinced me to install an expansion tank AND a supply regulator. The last thing I need is an old solder joint breaking loose in a 100 year old house. Thanks again

  • @firstlastnamehere6972
    @firstlastnamehere6972 ปีที่แล้ว +4

    Wow! What a great lecture and demo! Thank you.

  • @integr8er66
    @integr8er66 ปีที่แล้ว +11

    This is all very simple, but what is usually missed is that you do NOT need one of these unless you have a backflow preventer. most old houses do NOT have such a thing, so when the water begins to expand it simply pushes the extra volume back into the water main. Water supply systems use centrifugal pumps, and thus water can be pushed backwards through them, and on a huge city system, there is always a tap open somewhere.

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว +3

      Having a pressure regulator valve would also require the need for a thermal expansion tank.

    • @integr8er66
      @integr8er66 ปีที่แล้ว +2

      @@SmedleyPlumbing Nope, not unless it has an integral backflow preventer which I can tell you mine doesn't. A regulator alone doesn't stop backflow. I added a regulator 20 years ago because my water pressure is 125 psi, no issues at all, in just the last couple months I added an exp tank because the stupid local inspector doesn't know his ars from a hole in the ground, and the pressure still rises about 15 psi after you stop running water as the tank heats, but at least it doesn't have to reach the 125 psi main pressure before it has relief.

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว +2

      @@integr8er66 if incoming pressure is elevated (say 120 psi) and then the reducing valve brings that pressure down to 70 psi, the interior pressure would need to build up to over 120 psi before a bypass PRV will allow reverse flow. So you're right back to the elevated pressure you were trying to protect against with the prv until someone opens a faucet.

    • @-.__.__.-Rad
      @-.__.__.-Rad ปีที่แล้ว +2

      So… no danger of 155psi pressure buildup when water is supplied from the city with no back flow obstruction
      In my case, the water comes in at 60psi

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว +2

      @@-.__.__.-Rad all depends if the city has a check valve in their meter.

  • @keithq.s.c9284
    @keithq.s.c9284 ปีที่แล้ว +10

    Wow! A rare and great lecture by a plumber who knows the "how" of the trade and also understand the "why" of the theory behind it.
    Would love to see you shine some light on how to properly charge a thermal expansion tank. Is the factory charge of 40? psi good for all residential houses?

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว +1

      We could do a video on that soon!
      1. Measure your water pressure
      2. Turn off water to the home
      3. Remove existing expansion tank
      4. Using a tire pump, air up new tank yo match water pressure.
      5. Apply thread tape and or pipe dope to threads.
      6. Install new tank
      7. Restore water service making sure to open faucets and flush toilets to bleed out the air.

    • @balint133
      @balint133 ปีที่แล้ว +2

      @@SmedleyPlumbing I'm just a DIY-er but last time I installed an expansion tank I installed it then measured the pressure then closed the inlet valve of the water tank itself and left a hot water tap open in the bathroom. I simply aired the tank to the correct pressure then turned everything back on. I think it's faster/easier than shutting the main valve off :)

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว +1

      @@balint133 yeah that works also. The most important thing is that you are airing up the expansion tank without water pressure pushing against the other side of the bladder

    • @josevazquez1042
      @josevazquez1042 ปีที่แล้ว

      @@balint133 how did you come up with that on your own? 😊

  • @jamescoberly
    @jamescoberly หลายเดือนก่อน +1

    This is the absolute best video on thermal expansion. Thank you

  • @GrandmasFolly
    @GrandmasFolly ปีที่แล้ว +1

    This is the perfect explanation. This guy could teach calculus to an infant.

  • @harrydoherty8299
    @harrydoherty8299 5 หลายเดือนก่อน +4

    i’ve had water heaters in the same house with the same water meter and no expansion tank . lived here 35 years . never had anything other than the vacume relief valve and the pressure and temp relief valve . period.

    • @SmedleyPlumbing
      @SmedleyPlumbing  5 หลายเดือนก่อน

      Not all homes need them. Consider yourself lucky!

    • @miker.1804
      @miker.1804 29 วันที่ผ่านมา

      Just BS.. I worked in restaurants for 40yrs and we had pressurized tanks on equipment forever. It was there to smooth out the pressure on equipment so it was steady. This guy just proved himself wrong, you can pressurize air, so the tank is useless when the heated water “expands” it there to keep your house pressure from hammering. The TPI pressure relief valve is there as safety valve for high pressure from over heating.

  • @TheReal1953
    @TheReal1953 ปีที่แล้ว +3

    Historically, this wasn't an issue in municipalities. What has happened since is that the water companies have installed new meters that are 'tighter' internally. The excess pressure from residential WH's formally used to travel towards the city's meters and beyond. This caused them all kinds of issues on their pumping side. Now, the excess pressures can no longer pass into the city systems. However, residential customers didn't understand why their T&P valves were suddenly seeping/leaking one day.
    And in the beginning, when this started to be a problem, municipalities were silent to the plumbers and the public about what was happening. I remember this well. Now it's common knowledge, but it wasn't always so. The municipalities didn't want to be blamed for leaking, in house HW services when all they were doing was protecting their pumping stages/equipment.

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว +1

      Also the EPA started requiring more check valves in the municipal water system. Those check valves help ensure that water only leaves the system and can't return.

    • @TheReal1953
      @TheReal1953 ปีที่แล้ว +1

      @@SmedleyPlumbing Yes, I see this a lot in municipalities now; check valves right against the meters. Required too if you have a separate meter for irrigation as a fight against back-siphonage.

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว

      @@TheReal1953 yep. And thus the need for more thermal expansion control.

  • @ikepatrick9154
    @ikepatrick9154 ปีที่แล้ว +4

    This is really a "compression" tank, not an "expansion" tank. There's a difference. The compression tank compresses the trapped air in the tank, separated from the water by the diaphragm, while an expansion tank is open to the atmosphere. FYI 🤔

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว +2

      I see where you can think that. However, you'll never find one by calling it a compression tank. The code book doesn't even use that terminology.

  • @JavaJazzMusic
    @JavaJazzMusic 10 หลายเดือนก่อน +2

    Holy smokes that was one of the best demonstrations I've ever seen... thanks you so much for that brilliantly detailed example!

  • @31raleigh
    @31raleigh 6 หลายเดือนก่อน +2

    Yes my friend , you did wonderful job for mechsnical contractor

  • @tripjet999
    @tripjet999 6 หลายเดือนก่อน +3

    Please look at the camera while speaking . Sometimes, it appears as if you don't know where the camera is.

    • @SmedleyPlumbing
      @SmedleyPlumbing  6 หลายเดือนก่อน

      We filmed this one with multiple cameras. So sometimes we flip to the other camera. But that k you for your feedback!

  • @walterholzer939
    @walterholzer939 ปีที่แล้ว +8

    Shame shame, First of all you did not tell all your viewers weather or not you were on city water or well water or if you had a pressure reducing valve on your city water and you know what a difference that would make The only time you would need a expansion tank on a hot water system other than a heating Boiler is if you had a closed heat system. When you are connected to the city water there will never be a pressure rise from a water heater heating up because it will expand to the city water system and if you were connected to a well system you would have a well expansion tank on that also, which will also work for the heat expansion of the water heater heating up. In most cases dam near all you will not need a expansion tank on your water heater. Waste of you money.

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว +2

      If only you were correct. Aside from being required by code, they are more commonly needed and not.

    • @AuditAmplifier
      @AuditAmplifier 10 หลายเดือนก่อน +1

      Why do people rant like this about things they don't fully understand. "Shame, shame..." 🤦
      And it's, "whether," not, "weather."

    • @JB-gr6om
      @JB-gr6om 10 หลายเดือนก่อน +3

      I have lived in 4 homes in modern suburbia with many water heaters…. And never had an expansion tank.

    • @miker.1804
      @miker.1804 29 วันที่ผ่านมา

      People who write codes and the rules sometimes are just academics, who just read the book and have no common sense.

  • @ericsplicer
    @ericsplicer 6 หลายเดือนก่อน +1

    Outstanding video that teaches the plumbing. Good job i learned a lot from you.

  • @mikeyp947
    @mikeyp947 2 หลายเดือนก่อน +1

    This is a great video! I also noticed that the blue ring on the cold water line was a little melted, that means it was backdrafting.

    • @SmedleyPlumbing
      @SmedleyPlumbing  2 หลายเดือนก่อน

      Yes we have an attic fan. So every once in a while, the family will not have enough windows open and it forces the water heater to backdraft.

  • @jayaddison8032
    @jayaddison8032 6 หลายเดือนก่อน +1

    One of the best educational videos ive ever seen on youtube. You explained it perfectly sir. If only my highschool teachers would of had your teaching skills. Or possibly I wasn't paying attention back then. Thank you for the great lesson.

  • @moonjee505
    @moonjee505 9 หลายเดือนก่อน +2

    Thanks for the training. There was no such training back 10 years ago. I have been lacking such info. Your training gives me good tips in Plumbing. Thanks.

  • @blh3741
    @blh3741 ปีที่แล้ว +2

    perfect explanation! Our home has 30lb city water pressure and we have never had a water pressure release(knock on wood) Our last home had city pressure that could easily have 120psi without a pressure regulator. Those regulators didn't last long and you could hear neighbor's regulator failure with loud whistle/groan

  • @johnlysic6727
    @johnlysic6727 ปีที่แล้ว +2

    Excellent demonstration and explanation - thank you very much - my son bought an older home and the water heater pressure valve was leaking - I replaced it with a new one and now it is leaking again - now I know why - heading to buy an expansion tank and another pressure valve - very cool indeed

  • @zeeryos102
    @zeeryos102 5 หลายเดือนก่อน +2

    This is an awesome explainer video! Thank you! Now I am educated and can educate 😊

  • @arthouston7361
    @arthouston7361 7 หลายเดือนก่อน +1

    All of the work I do is applied physics. I do commercial HVAC. This was a good demonstration. Thanks for helping those kids to get a clue.

  • @laneburgess1643
    @laneburgess1643 ปีที่แล้ว +1

    Best video I have seen explaining the expansion tank operation and purpose.

  • @sme7725a
    @sme7725a 4 หลายเดือนก่อน +1

    Perfectly answered this homeowner's question of, do I need to replace my reportedly broken expansion tank and what does it actually do. Thank you!

  • @Thad811
    @Thad811 7 หลายเดือนก่อน +1

    The best video explaining thermal expansion tanks and water heating functions! Excellent work!

  • @certifiedpersonaltrainer1173
    @certifiedpersonaltrainer1173 8 หลายเดือนก่อน +1

    Great video, plumber told me about an expansion tank and I had an idea but didn't really know how it worked. Thanks.

  • @karenstein8261
    @karenstein8261 4 หลายเดือนก่อน +1

    I was under the impression that water heaters were an “open” system, so did not need expansion tanks. By contrast, hot water heating systems were “closed” and thus needed the expansion tanks., Thank you, and other commenters, for educating me. I plan to add an expansion tank as a result.
    I have asked this question - to tank or not to tank - of a number of professionals and none seemed confident in their responses. Their answers were limited to “what they’ve seen.”
    Your point about the anti-corrosion glass liners cracking, exposing the tank metal to corrosion, makes a lot of sense. It seems to me that it should be possible to detect such a breakdown, which would give you some warning that the water heater was living on borrowed time - unless the liners are frequently defective from the start.
    Indeed, I wonder why expansion components re not integral to the water heaters.
    I begin to understand why my first water heater split a seam after less than seven years. The replacement heater just passed the four year mark.
    Based upon your videos, I should replace the anode and add an expansion tank as soon as I can - if I want this heater to last.

  • @BeeTreeGuy
    @BeeTreeGuy 10 หลายเดือนก่อน +1

    Awesome video. My brother-in-law is a plumber and he was trying to explain a lot of this to me, I wasn't quite sure what he was talking about. Now I totally understand after seeing it in action. Thanks for the outstanding and very educational video.

  • @choimdachoim9491
    @choimdachoim9491 7 หลายเดือนก่อน +1

    The explosive spurt of hot water at first use in the morning in old homes always caught my attention. So simple. It occurs to me that with PEX systems this tank in not needed because the PEX expands throughout the home.

    • @SmedleyPlumbing
      @SmedleyPlumbing  7 หลายเดือนก่อน

      The tank is still needed because that expansion running the pressure over 80 psi exceeds the designed limits of the code.

    • @choimdachoim9491
      @choimdachoim9491 7 หลายเดือนก่อน +1

      @@SmedleyPlumbing Seems like that would depend upon the total length and sizes of the PEX system. I live in a mobile-home with a cpvc and grey tubing system and don't have this pressure problem. However, you have convinced me that installing an expansion-tank will relieve stress on my plumbing. My home is 70 feet long and it takes forever for hot water to reach the kitchen and other bathroom so we recently decided to add a smaller water heater in the corner cabinet in the kitchen. I've now included the expansion tank in my plans.

  • @michaelboyle1983
    @michaelboyle1983 9 หลายเดือนก่อน +1

    Thanks for showing this, and God bless you!

  • @bryanmoss9015
    @bryanmoss9015 10 หลายเดือนก่อน +1

    Great job. I'm electrically inclined and hate plumbing. You did an amazing job explaining this to me in a basic and simple way. Thank you!

  • @danrhoads2831
    @danrhoads2831 ปีที่แล้ว +1

    I came across this video and thought it was so cool I showed my brother-in-law who is an electrical engineer and has many patents I just wanted to let you know! Thank you for the information

  • @John-dp3ln
    @John-dp3ln 11 หลายเดือนก่อน +1

    One of the best demonstrations I’ve ever seen. Very well done!

  • @johnledger3010
    @johnledger3010 ปีที่แล้ว +1

    Superb video, explains why I had a problem with the release valve expelling water and why I needed a new expansion vessel.

  • @steve7875
    @steve7875 11 หลายเดือนก่อน +1

    Awesome demonstration. Just purchased a home built in 2009, and surprisingly the newly replaced water heater in 2019 had no expansion tank. Going to get one installed right away. Thank you!

  • @scubabeme
    @scubabeme ปีที่แล้ว +2

    All true if the house has a PRV or some form of backflow prevention (i.e., check-valve, not all do!) as that won't allow water to expand back into the system, causing the excess pressure. If the house doesn't have a a PRV or check valve an expansion tank is NOT needed. My home has neither a PRV nor a tank. That being said, good explanation of why many homes DO need a tank!

  • @willl3712
    @willl3712 ปีที่แล้ว +1

    The best demonstration about the purpose of an expansion tank, and how it functions. Job well done, well done!!!!!!!

  • @LTVoyager
    @LTVoyager 10 หลายเดือนก่อน +1

    Two comments from a retired engineer:
    1. I can’t believe you were questioning whether the engineers were correct about the amount of water expansion with temperature. 😂
    2. Even though I understand this principle very well, it is always fun to watch a good experiment. Nicely done. It is nice to see a tradesman who takes the time to understand the science involved in their trade.

  • @pepawspostings9231
    @pepawspostings9231 ปีที่แล้ว +2

    What a great video for understanding how an expansion tank works and why I need to install one on my water heater.

    • @SmedleyPlumbing
      @SmedleyPlumbing  ปีที่แล้ว

      Thanks!

    • @MikeNaples
      @MikeNaples ปีที่แล้ว

      Agree with your sentiments about the vid. I've lived in the same house for 33 years. Three water heaters inside along with a fourth heater in the detached garage. All have never been maintained and usually failed (slow leak or quit heating) between 10 and 20 years. I don't have any expansion tanks and never (to my knowledge) had a relief valve open up nor a pressure related issue. Either it's not that big a problem or my increase in pressure is being "relieved" back into the city water supply. Not sure if there is a one way valve at the meter since I don't know what it would look like.

  • @briansmeback8912
    @briansmeback8912 10 หลายเดือนก่อน +1

    Probably one of the best TH-cam videos on anything I’ve ever seen. Ever. If you don’t teach or hold instruction classes, you should. Fantastic video. Well done sir. 😎

  • @edwardluhn8556
    @edwardluhn8556 26 วันที่ผ่านมา +1

    Excellent job. Very informative. Thanks for making.

  • @ahbelhealy3665
    @ahbelhealy3665 6 หลายเดือนก่อน +1

    Thank you man. This was so educational. It helped me better understand the workings of an expansion tank and a water heater. I just started my apprenticeship program so I was really glad I found this video.

    • @SmedleyPlumbing
      @SmedleyPlumbing  6 หลายเดือนก่อน

      Love it! Stick with it and you'll do great things!