old boiler with major issues fixed

แชร์
ฝัง
  • เผยแพร่เมื่อ 5 ก.ย. 2024
  • old boiler with major issues fixed
    www.valueteste...
    merch = teespring.com/...
    / stevenlavimoniere
    lavimoniere productions llc
    subscribe to my channel
    / @stevenlavimoniere
    web site
    lavimoniereplum...

ความคิดเห็น • 107

  • @7islander
    @7islander 5 ปีที่แล้ว +20

    That internal pipe wrench just paid for itself. The right tools can save your skin.

  • @edjackful
    @edjackful 5 ปีที่แล้ว +7

    Not luck, its experience and knowing what your doing. Good job.

  • @timhendley1950
    @timhendley1950 5 ปีที่แล้ว +5

    Steve’s got every tool known to man, up in that work truck of his...

  • @FrankRuiz66
    @FrankRuiz66 4 ปีที่แล้ว

    Holy crap that thing was a turd. I'm surprised you even worked on it.
    I'd have shut it down.
    You're a better man than I am..

  • @KYHB-q2i
    @KYHB-q2i 5 ปีที่แล้ว +2

    Good lord ... It looked like they had salvaged that relief valve off of a sunken ship & had barnacles on it. Great job on replacing it!

  • @MegaGeorge1948
    @MegaGeorge1948 5 ปีที่แล้ว +7

    That relief valve looks like it came off of the Titanic boiler.

  • @jakeandrus690
    @jakeandrus690 5 ปีที่แล้ว

    That internal pipe wrench saved your ass! Right tool for the job

  • @joedugas9462
    @joedugas9462 5 ปีที่แล้ว +3

    I was yelling at my computer " please dont touch that relief valve!!".....Nice recovery Steve!...I've had that nightmare A few times.

    • @stevenlavimoniere
      @stevenlavimoniere  5 ปีที่แล้ว +7

      i took a big chance touching it but ,,,this is what seperate the men from the boys...it will make a good video i was thinking ......might of turned into a real shit show very quickly

    • @joedugas9462
      @joedugas9462 5 ปีที่แล้ว

      @@stevenlavimoniere those internal nipple extractor's 50/50 on a good day... It could have killed that boiler if the threads broke off. You are a brave man!

    • @tonysova4687
      @tonysova4687 5 ปีที่แล้ว

      Steve is correct That's a good sign of a excellent tech always check safety's

  • @Longeno55
    @Longeno55 5 ปีที่แล้ว +1

    Damn. You masterfully coaxed that rusted nipple off like a boss.

  • @VinylToVideo
    @VinylToVideo 4 ปีที่แล้ว +1

    Steve fixes this "old shit" so good there's no point in replacing it! And damn.. that basement finished around here would rent for like $1000+ a month!

  • @SilverCymbal
    @SilverCymbal 5 ปีที่แล้ว +8

    Amazing job! Next level for sure! The best is the end scene with the Nest, running a 1920 boiler with rotted fittings 😂

    • @cutrara7
      @cutrara7 5 ปีที่แล้ว +1

      @@Guillotines_For_Globalists its at least 50 years old

    • @erikj.2066
      @erikj.2066 5 ปีที่แล้ว +1

      Blaine Bugaski Oh yeah, that looks like it was a fresh install in ‘99. Some plumbing supply house had a deal on a boiler, and fittings that had been forgotten in the warehouse since the early 60’s.

    • @cutrara7
      @cutrara7 5 ปีที่แล้ว +1

      Blaine Bugaski well that is a bet you would lose. steve titled the video is “old boiler with issues”. 20 years is not old. If it was less than 20 years old they would have replaced the old expansion tank up between the floor joists with a diaphragm expansion tank. Also I grew up in an early post-war home (late 1940s) and it had a poured concrete foundation. She’s a crusty one, Mr. Grinch!!!

    • @cutrara7
      @cutrara7 5 ปีที่แล้ว

      Blaine Bugaski the fact that all the tradesmen here are telling you the same thing... that you’re not even in the same flippin ballpark, yet you are so adamant to save face. We work with this stuff everyday. You don’t even know the difference between the old expansion tanks and modern diaphragm tanks. They were a game changer, were invented in 1954 by Amtrol (industry leader in ex tanks) and used exclusively since the 60s. You should probably just stick to real estate because you’re way out of your element here. This boiler ain’t no spring chicken y’all!

    • @rskalisky
      @rskalisky 4 ปีที่แล้ว +1

      @@Guillotines_For_Globalists Thanks buddy, when we need dogs videos we know exactly where to look.

  • @johnracek7633
    @johnracek7633 2 ปีที่แล้ว

    I even enjoy the repeats. Good stuff. Go Steve !

  • @johnracek7633
    @johnracek7633 2 ปีที่แล้ว

    Most guys would sell a new boiler. Really amazing !

  • @TX2200000
    @TX2200000 5 ปีที่แล้ว +1

    The right tools for a challenging job.

  • @mickmclovin3020
    @mickmclovin3020 3 ปีที่แล้ว

    I havent seen a circuit setter like that in a long time, Wow you sure work on some old stuff

  • @brianmahoney154
    @brianmahoney154 5 ปีที่แล้ว +3

    The differential was better at 20. It effects the low side of the control. At 10 the temp will drop 10 below set point and come back to where it was set. When set at 20 it will still come on when it drops 10 but won’t shut off until it’s 10 above set point. Set at 25 it will override set point by 15 degrees.

    • @brianmahoney154
      @brianmahoney154 5 ปีที่แล้ว +2

      @@jcstevegigs so on both the high and the low side aquastat settings they will break at the temp set at and then make when the temp drops 10 degrees below set temp. This is fixed on a triple aquastat high side and can not be adjusted.
      But on the low side you can make changes. the low side will always make when it drops 10 degrees from the dial setting. The thing is that by raising the differential you will change the temperature it breaks at.
      Normally the differential is set at 10. This makes it operate as we expect it to. Let's say we have it set at 160. It will break when running from the low side at 160 and make at 150.
      Here's the thing. If we raise the differential to 15 and leave the temp setting at 160 it will still make at 150. But it will over ride and brerak at 165. That's where the extra 5 degrees go.
      If you set the differential to 25 it will again make at 150 but won't break until it climbs 25 degrees which is 175 degrees.
      This is a way to correct a not enough hot water call in the summer. Once the shower starts and drops the boiler temp to 150 it will make and stay running until it reaches the over ride set by adjusting the differential.
      If the differential is set to 25 the burner will run until the boiler temp reaches 175. So the shower problem should be solved. And the boiler will not come back on until the temp drops to 150.

  • @stanhankins3175
    @stanhankins3175 5 ปีที่แล้ว +10

    That old relief valve had barnacles on it.

  • @johnkrim8377
    @johnkrim8377 5 ปีที่แล้ว +3

    That had to be one of the worst relief valves I've ever seen , great job Steve !

  • @markf350s
    @markf350s 5 ปีที่แล้ว +1

    That's why you're the best buddy nice save used to be heavy equipment mechanic and I thought I was the only one that ran into shit shows nice job and I never knew they had an internal wrench like that pretty cool once again thank you for sharing

  • @phillipjennings8935
    @phillipjennings8935 5 ปีที่แล้ว +1

    Dr. Steve cutting out the cancer!

  • @timshields5308
    @timshields5308 5 ปีที่แล้ว +1

    Wow that relief valve looks like it was off the titanic, that's was so bad. I thought that nipple was just gonna crumble, I hate when that happens, it's the worst. I've used a hacksaw and a chisel to get the piece out, it sucks.. that internal pipe wrench is amazing, I can't believe I've never seen them before.. I am ordering a set right now. That's such a lifesaver of a tool to have.. thanks for that steve!! You da man...

  • @CraftyDus
    @CraftyDus 5 ปีที่แล้ว +3

    That expanding nipple getter-outter is really sneaky and cool. Get’s you right out of a jam !

  • @ljevans5993
    @ljevans5993 5 ปีที่แล้ว +1

    A master at his craft !

  • @johnerway7255
    @johnerway7255 5 ปีที่แล้ว

    Good demo,showing valve open to solder into system, prevents damage. Thanks Steve, great job.

  • @ed6837
    @ed6837 5 ปีที่แล้ว +1

    Good job but I MA boiler inspectors insist that now all relief and safety valves be installed stem up. Only exception is T & Ps

  • @rcdogmanduh4440
    @rcdogmanduh4440 5 ปีที่แล้ว +1

    I think the last ten guys did look the other way lol. Keep eating those Wheaties Stevie!

  • @montygram
    @montygram 5 ปีที่แล้ว +3

    No Taj Mahal mama, oh Yeehaw next level.

  • @rtoweprojects9072
    @rtoweprojects9072 5 ปีที่แล้ว +1

    I like that internal pipe wrench tool never seen that before. That nipple and relief valve should be put in a museum of worst rusted out fittings. 😂
    Are you bidding on the new boiler replacement?

  • @55098
    @55098 5 ปีที่แล้ว +1

    Steve at it again mama next level next level

  • @Novisk58
    @Novisk58 5 ปีที่แล้ว +1

    how'd you get that job? Finally working in the Taj Mahal, nicest basement so far with a boiler from the 1800's. that safety had trouble written all over it.

  • @Gr8thxAlot
    @Gr8thxAlot 5 ปีที่แล้ว +3

    It looks like you're working on the Titanic.

  • @happyirishman4683
    @happyirishman4683 5 ปีที่แล้ว +2

    Nice Job Steve , I would have tagged it out and sent it to the scrap yard before taking that r valve off

  • @tomdale1313
    @tomdale1313 5 ปีที่แล้ว +1

    good touch(your years of experience), lucky but great touch with the pipe extractor (internal) i was going to try some heat also

    • @eracer350
      @eracer350 5 ปีที่แล้ว

      Penetrating oil could help also

  • @rides8087
    @rides8087 5 ปีที่แล้ว +1

    I am out of Woodstock ct. I got it.

  • @donnierobertson3088
    @donnierobertson3088 5 ปีที่แล้ว +1

    Good job

  • @Eddy63
    @Eddy63 5 ปีที่แล้ว +3

    Are you gonna do the new install ... Just wondering ... I shall do a shot in your and Miss Molly's honor ...

  • @superiorcomfortheatingairl3373
    @superiorcomfortheatingairl3373 5 ปีที่แล้ว

    You handled that relief valve good, now if I was there and that happened to me, I would of automatically have said “F***”

  • @Bob.W.
    @Bob.W. 5 ปีที่แล้ว +2

    96th, lol. another reason to have a separate water heater imo.

  • @robras8805
    @robras8805 5 ปีที่แล้ว

    Do it on the fly mama!

  • @theoldbigmoose
    @theoldbigmoose 5 ปีที่แล้ว +2

    Whats the attack plan if the nipple had broken off flush with the boiler casting? ... and the ID wrench wouldn't bite in the stub left in the boiler? Pondering what plan "C" would be?

    • @69thebroken
      @69thebroken 5 ปีที่แล้ว +1

      As a pipe fitter in the fire industry we would grab our ridged nipple extractor (A.K.A Easy-out) as it very common that fittings break at the threads on old systems at the control valves.

    • @johnkrim8377
      @johnkrim8377 5 ปีที่แล้ว +2

      Had many nipples break off flush , you sometimes have to saw a groove in the piece and use a small chisel to get it out. Chemicals in the steam would eat the nipples away. Have a set of internal pipe wrenches for a long time.

  • @Bunch007
    @Bunch007 5 ปีที่แล้ว +2

    And I thought Pennsylvania had the worse roads in the country.

  • @jeremygrove3177
    @jeremygrove3177 5 ปีที่แล้ว

    "That's what they call a shit show!!" 😂😂No truer words have ever been spoken! Lav is the man momma.

  • @MrBooMY3
    @MrBooMY3 5 ปีที่แล้ว

    You should do a review on a cheap chinese diesel heater. You might like one for your truck.

  • @winkhvac62
    @winkhvac62 5 ปีที่แล้ว

    Awesome job

  • @lcampm2
    @lcampm2 5 ปีที่แล้ว

    wow nice job.

  • @xX_Kryptis_Xx
    @xX_Kryptis_Xx 5 ปีที่แล้ว +1

    oh mama, shes a leaker!

  • @williamdyckman9704
    @williamdyckman9704 5 ปีที่แล้ว

    Good to have those inner pipe wrenches, for situations as you had. Do you use tape along with pipe dope or just dope alone on those pipes going into furnace?

  • @richardprice713
    @richardprice713 3 ปีที่แล้ว

    Wow!

  • @Skoot61
    @Skoot61 4 ปีที่แล้ว

    - Steve, what is the significance for adjusting the differential control dial from 20 back to 10?

  • @happyirishman4683
    @happyirishman4683 5 ปีที่แล้ว

    Damn Ol Grich strikes again

  • @ReparadorAficionado
    @ReparadorAficionado 5 ปีที่แล้ว

    That was a crusty one, Mr. Grinch

  • @webbac8491
    @webbac8491 4 ปีที่แล้ว

    Looks like the valve suffered from dezincification.

  • @kylebass4635
    @kylebass4635 5 ปีที่แล้ว +3

    That value was a crusty one Mr Grinch 😅🤣😂 That boiler would probably last another 30 years; Oil Heats Best!

  • @shupe1907
    @shupe1907 5 ปีที่แล้ว

    Should do the trick for a while. Wonder if you will be putting in new system?

  • @mathewnelsonjr3321
    @mathewnelsonjr3321 3 ปีที่แล้ว

    could you not just lower the cold waters flow there fore causing more hot water to stem up for bathing , dishes, etc

  • @ckm-mkc
    @ckm-mkc 5 ปีที่แล้ว +1

    Ah, yes - let's add an expensive piece of bling (Nest) to a completely worn out dangerous system, that will fix it..... :rolls eyes: Lipstick on a pig.

  • @gregbouchard8353
    @gregbouchard8353 4 ปีที่แล้ว

    Keep up there good work on TH-cam how are u ok mate u do a relly good job on TH-cam well done mate hove a good day mate form Greg Bouchard hove a good one mate hove a good day mate am a big fan of u on TH-cam u do a relly good job on TH-cam

  • @ed731pdh
    @ed731pdh 4 ปีที่แล้ว

    Damn lucky the pipe didn't fold up on itself, would have been major grief all round.

  • @dburto13
    @dburto13 5 ปีที่แล้ว +1

    Nice work Steve! I like those nipple extractors, best one's I have seen.

  • @dewittarchibald7191
    @dewittarchibald7191 5 ปีที่แล้ว

    and the carbon dating on the relief valve was certainly mezozoic era.

  • @martinf.3455
    @martinf.3455 5 ปีที่แล้ว +1

    First, thanks steven!
    Excellent work =)

  • @iftakharmohammed1942
    @iftakharmohammed1942 5 ปีที่แล้ว +1

    Steve you showed some real talent there in ref to the extraction of that crusty nipple, top notch skills on another level!

  • @roberthudanish7405
    @roberthudanish7405 5 ปีที่แล้ว +1

    does tempering the cold side reduce the water pressure at the fixture?

  • @marktombasco4400
    @marktombasco4400 5 ปีที่แล้ว

    do you ever use SharkBite connectors?

  • @hrdworkin7633
    @hrdworkin7633 5 ปีที่แล้ว +3

    That WAS a shit show! I see you brought your golf clubs to the party. Great Job....better you than me

  • @reese8752
    @reese8752 3 ปีที่แล้ว

    It’s got barnacles on it...

  • @commonsense3673
    @commonsense3673 5 ปีที่แล้ว +1

    Scammer call really Steve Run !!! It's been on the world news !! Sounds like you could use the app called Tru caller !

  • @josephcarino5829
    @josephcarino5829 3 ปีที่แล้ว

    Candkeman. Lmao

  • @p.thadeushornswoggler4987
    @p.thadeushornswoggler4987 5 ปีที่แล้ว +2

    Worst Relief Valve Ever Mama ! lol That nipple coming out was a beautiful thing.

  • @boulangm
    @boulangm ปีที่แล้ว

    My buddy could be a double

  • @gyver471
    @gyver471 5 ปีที่แล้ว +3

    I swear that’s my saying for everything “it turned into a shit show”🤣🤣

  • @markpowell1031
    @markpowell1031 5 ปีที่แล้ว +1

    4th

  • @cutum
    @cutum 5 ปีที่แล้ว +1

    Welcome to the shit show, Mr. Grinch!

  • @J-Colt
    @J-Colt 5 ปีที่แล้ว +3

    Only one mama's boy so far has thumbed this video down because he ain't got no hot wadda mama! Thanks Steven. A bit of a shit show but could have been worse.

  • @coolbluelights
    @coolbluelights 5 ปีที่แล้ว

    doesn't anyone bother to change their default ringtone? yeesh... I hate that ringtone so much

  • @timj5367
    @timj5367 5 ปีที่แล้ว

    What a hush your mouth show mama....

  • @mustangdbest220
    @mustangdbest220 5 ปีที่แล้ว +1

    I am the 100th like

  • @rubinsd2007
    @rubinsd2007 5 ปีที่แล้ว

    First