Transducer replacement for Graco and Titan

แชร์
ฝัง

ความคิดเห็น • 274

  • @benschlotte8242
    @benschlotte8242 ปีที่แล้ว +3

    Love the video !! I was able to scavenge a transducer off an older 440 that I own and was able to fix my rig and now I’m back to the job at hand. I ALMOST Aniston went out and spent $1200 or so on a new one. 1 hour including watching you video did the trick !! Really ! THANK YOU for this video !!

  • @87Lowbird
    @87Lowbird 5 ปีที่แล้ว +2

    I just took a job as a sprayer tech. Some of these things can be intimidating to a newbie. Thanks for the info! I've subbed, hope you make more videos about sprayer repair 👍

  • @jfb09able
    @jfb09able 6 ปีที่แล้ว

    Thanks a lot bud! Your so knowledgeable with these sprayers!

    • @jfb09able
      @jfb09able 6 ปีที่แล้ว

      Could you maybe do a video on repacking a graco contractor gun or the Titan guns? The way you explain things really click

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  6 ปีที่แล้ว +1

      jfb09able I will be happy to do this. Give me a few days.

    • @jfb09able
      @jfb09able 6 ปีที่แล้ว

      Brian Shumack thanks man

  • @seymourbuttz3817
    @seymourbuttz3817 5 ปีที่แล้ว +1

    Thanks dude. I just left my rig out in my freezing truck and I think this is exactly what happened.

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  5 ปีที่แล้ว

      Hopefully this will help you out.

    • @johnboyjohnson4315
      @johnboyjohnson4315 2 ปีที่แล้ว

      I did the same thing left it in the van and it froze it the transducer

  • @CHUNKYCATSFISHING
    @CHUNKYCATSFISHING 6 ปีที่แล้ว +1

    Fantastic Video Nicely Done Thank You

  • @courtney727ray
    @courtney727ray 5 ปีที่แล้ว

    Love your video. I am a local paint contractor in Raleigh NC. I have 2 440's and 1 840. The 440,s are more than three times the age of the 840 yet they have less trouble. Needless to say I would love to see an 840 packed and rod replacement. I am trying to learn this stuff on my own. Repair bills are expensive, takes forever and aren't cheap.

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  5 ปีที่แล้ว +1

      Thank you for watching. I have a video of an 840 rebuild. If this is not the model you have, let me know which model you have and I will try to locate one for a video.

    • @kerinmendez6641
      @kerinmendez6641 2 ปีที่แล้ว

      Where do you order parts for your titan 440

  • @NigthRod
    @NigthRod 3 ปีที่แล้ว

    tanks for the video i just clean Transducer and now work normol but have 1 have extra new Transducer

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว +1

      Save it. You will need it one day. I am glad the machine is working

  • @pgrickly
    @pgrickly 6 ปีที่แล้ว

    my titan 440I is a little different ser # 21241693 it does not screw into the block. It has a set screw and the stem is shorter than the ones I am seeing to order.Just would like to make sure I am getting the right one. Thanks again good clear instructions.

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  6 ปีที่แล้ว

      The part you need is 704-251. When you install the transducer press it into the block by hand. Replace block tighten set screw. Check for leak by slowly building pressure. If a leak appears, drop pressure and reset the transducer.

  • @MrAyarza
    @MrAyarza 2 ปีที่แล้ว +1

    Thanks Brian

  • @larryogkushnoriega7776
    @larryogkushnoriega7776 2 ปีที่แล้ว +1

    Good video man really helpfull

  • @saenzlovo
    @saenzlovo 3 ปีที่แล้ว +1

    Thank You Very Much!!!

  • @BobSoloMan
    @BobSoloMan 6 ปีที่แล้ว

    In my business of painting apartments, I MIGHT use my rig once a month. I have a few skid based rigs like a 440i and an old school SprayTech (sherwin) - is there a product I should run thru the pump section after using the rigs - that will keep the caged ball inside the fluid section from sticking? Seems I'm having to do a quick removal of the inlet hose section and pushing a spudger (hard plastic awl-like tool) to pop the caged ball loose. Would RV antifreeze or a product of that sort work the same as the Graco blue liquid? (looking for economical here as well). Thanks for your vids. I love seeing how these things work and how to repair them since my local shop takes 3-4 weeks for a repair.

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  6 ปีที่แล้ว +2

      Bob SoloMan if you use latex for the most part, RV antifreeze is superior to most anything else. If oil base is your most often used product, then use a mix of kerosene and oil 50/50. Run through the machine. Turn pressure down as low as possible where it still strokes. Once it builds pressure, turn it off. Pull the trigger to drop pressure. Nothing will stop the balls from sticking every time. I have found these two work best and are reusable.

  • @salr5272
    @salr5272 ปีที่แล้ว

    Good information I have a graco linelazer II . My machine sometimes overpressizes and if I take the plug from the transducer off and replug it fixes it and sometimes it takes a couple of tries. Does the plug on the board loosen up or is the transducer plug wear?

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  ปีที่แล้ว

      Yes, the socket for the the plug can loose connection. Sometimes using hot glue to reset the socket works.

  • @albertomendez4485
    @albertomendez4485 5 ปีที่แล้ว

    Thanks this is probably what happen to my Rent Spray 600, 6:18

  • @MrAyarza
    @MrAyarza 2 ปีที่แล้ว

    Hey Brian, I’ve the push in transducer on my 740! The pump is at least 18 years old and want your advice if I should get a new one and be prepared in case it gets discontinued. EBAY has one oem for around $200 . As always your videos are very helpful and we appreciate it. Thanks

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  2 ปีที่แล้ว +1

      I would definitely do that. The part will not go bad just storing it. I would not get anything that is not Titan manufactured. Be careful, some items list as OEM, but are not.

  • @jorgprok3915
    @jorgprok3915 4 ปีที่แล้ว

    Hi, have a Graco GMax 3900 gas powered, didn't use it for a while and now prime good but when build pressure stall the engine. Someone told me that can be the clutch but with the switch the clutch engage and disengage. Could be a bad transducer?
    Thanks

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  4 ปีที่แล้ว

      You need to find out what pressure you are getting. If you are building too much pressure, that can stall the engine. High pressure can be caused by a bad transducer. The clutch seems fine.

  • @reflectance_bcs
    @reflectance_bcs ปีที่แล้ว

    Hi Brian.
    I have a Titan 440i and when I took it apart I realized that the Transducer is not like the one that comes with most of these machines.
    How I can contact you to send you photos of the pieces?
    Best regards

  • @ruisousa125
    @ruisousa125 2 ปีที่แล้ว

    Hi there, is it possible to upgrade a machine that as mechanical pressure control for this eletronic Control?
    Is only needed to buy the PCB and the transducer ?
    Thanks !

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  2 ปีที่แล้ว

      If it is a Graco, you would need a new filter manifold, control board and transducer at the minimum. The Titan would be much more difficult if it was even possible.
      There would be no cost advantage.

  • @mariomontiel8097
    @mariomontiel8097 2 ปีที่แล้ว

    Got a 395 ultra control board flashing 5 times and my sprayer power shut off so I have to turn on and off the power switch to make it work but as soon as I pull the gun trigger stop running again so I have to on and off the power switch. What will be the problem

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  2 ปีที่แล้ว +1

      Seems that there is an electrical problem between the board and the motor. Unplug the machine, then unplug the motor from the board. Plug the machine in and turn the machine on. Turn the pressure all the way up. The motor will not operate because it is unplugged from the board. If everything else continues with out shutting down (in other words the board stays lighted) then you may have a motor problem.
      Code 5 states motor not turning or high current.

  • @robertmcginn3542
    @robertmcginn3542 4 ปีที่แล้ว

    I’ve got a linelazer II 3900, and I get fluctuations in the pressure. I thought it was the paint at first, now I think it may be either the transducer, pc board or potentiometer . Can someone help, please!

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  4 ปีที่แล้ว

      When you say that there is a fluctuation, try to explain exactly what you mean please.

  • @conytorres6210
    @conytorres6210 5 ปีที่แล้ว +1

    I want to know why my graco 395 when it reaches the pressure I set it to doesn’t stop once it reaches the pressure I set It to . Doesn’t turn off at all. I replace the transducer because it might be that but still doesn’t stop.

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  5 ปีที่แล้ว +1

      Without a pressure gauge to tell us what the pressure is as the machine pumps, it is a little harder to say.
      My guess is one of two things. You may have a piece of trash stuck in the upper or lower ball.
      Or, you have a pressure leak caused by bad packings of prime valve.
      Pull the lower inlet housing off. Make sure the lower ball is free of debris. Look up into the upper section. There is a small hole. Slide a thin screw driver in the hole and move the upper ball around with force. Do not hit he screw driver. The ball should move freely.
      Put the machine together and try it. If it builds and stops, you are done.
      If it does not, pull the prime hose out of the water while the prime valve is off or set to spray. If you have fluid that comes out at this point. The prime valve needs to be replaced. If these do not take care of the issue. Contact me back.

    • @shanejackson3433
      @shanejackson3433 3 ปีที่แล้ว

      Hey Brian, I’ve tried what you suggested but no luck. I have a graco 210 es. Any suggestions?

  • @laurorodriguez2160
    @laurorodriguez2160 2 ปีที่แล้ว

    Excúsame if pressure control switch is bad in a graco 390 could be a reason to won’t start thanks

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  2 ปีที่แล้ว +1

      Yes. If pressure control is bad, the machine will not start

  • @kennethswearingen7196
    @kennethswearingen7196 ปีที่แล้ว

    my 390 graco stays pumping at full max but when i turn the pressure down to make it stop it want come back on when i turn it back up it starts pumping at max pressure but want stop when gun trigger is released,gun hose all new what could be my problem

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  ปีที่แล้ว

      You either have bad packings or the prime valve is leaking.

  • @hugoinfante1
    @hugoinfante1 4 ปีที่แล้ว

    I have A titan 440 impact, the manifold is licking, i already got the o ring but can't find Where exactly it goes,? Also Where do i need to go to get certified to fix sprayers, for graco and titan,,,thank you.

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  4 ปีที่แล้ว

      There is a grove toward the bottom of the base, not on the removable body. The groove is a continuous circle, not part of the threads. It is a pain to get in without damage. Titan and Graco can direct you to a certified technician from their website.

  • @johnnyrosales830
    @johnnyrosales830 3 ปีที่แล้ว

    Question I changed out the transducer on my titan 440 and the pressure not still doesn’t adjust pressure it stays the same no matter if I turn it all the way to the right or in priming mode what can it be ??

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      If this is a 440 impact, the little computer board under the machine could be back.

    • @johnnyrosales830
      @johnnyrosales830 3 ปีที่แล้ว

      @@Brian_the_repair_guy ok thanks for the reply I’ll look into it and replace it thank you

  • @bryanthunders2046
    @bryanthunders2046 4 ปีที่แล้ว

    I have a Titan 440i, the unit primes and sprays fine, but it has way to much pressure that doesn't change at all when set at a different setting, when I switch the prime valve to spray, it builds up alot of pressure that leaks from the prime spray valve, and filter. So much pressure it blew a hole in a new hose, what could this be? It has new packings and new transducer

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  4 ปีที่แล้ว +1

      It is possible the new transducer is faulty. You can try another. If the transducer you installed is faulty, it does have a warranty.
      If that is not the issue, then the board has a fault. New board is needed.

    • @alexulloa118
      @alexulloa118 ปีที่แล้ว

      El mismo problema tengo que ay que cambiar

  • @j3al3yi3oy5
    @j3al3yi3oy5 ปีที่แล้ว

    Excellent video mate very hopeful, just wondering my graco 595 I’m getting code 02 saying high pressure detected when I start priming it and won’t work so you reckon it’s the transducer needs replacing? Thanks

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  ปีที่แล้ว +1

      That would be my first thought. That is most common. There are a couple other possibilities, but transducer is the first stop

    • @j3al3yi3oy5
      @j3al3yi3oy5 ปีที่แล้ว

      @@Brian_the_repair_guy thanks mate 👍🏻

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  ปีที่แล้ว

      @@j3al3yi3oy5 I hope it is helpful

    • @j3al3yi3oy5
      @j3al3yi3oy5 ปีที่แล้ว

      @@Brian_the_repair_guy it was mate, it was exactly what’s wrong with it, by the way do you reckon it’s ok to use a After market transducer for it? I know it’s always good to use genuine one but I’m not a professional painter so the
      Machine won’t get use much. Thanks

  • @davidram1974
    @davidram1974 5 ปีที่แล้ว

    On my new titan 440. I have continuaty on the motor and everything, even 110v power but motor sound like it's wants to slight turn but it doesn't. Could it be the transducer because it was stored for a long time?

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  5 ปีที่แล้ว

      It could be the transducer. The transducer can be damaged by freezing or long term storage. The transducer could be sending the wrong signal and the computer thinks it is under pressure when it is not.

    • @davidram1974
      @davidram1974 5 ปีที่แล้ว +1

      @@Brian_the_repair_guy yes sir I spent about 4 hours searching online and someone else had the same issue as me and the answer was bad thansducer. Thank you for replying to me sir.

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  5 ปีที่แล้ว +1

      @@davidram1974 no problem. Any other questions feel free to ask.

    • @davidram1974
      @davidram1974 5 ปีที่แล้ว +2

      @@Brian_the_repair_guy thanks so much sir

  • @jeffhaman9010
    @jeffhaman9010 4 ปีที่แล้ว

    This is off subject- I'm looking at a 1st Gen Graco Ultra Max 1595 for $500. Pump is still working. Should I be worried about a $3000 repair bill down the road?

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  4 ปีที่แล้ว

      There is always a possibility of an expensive repair down the road. When buying used, you want to check availability of repair parts based on the age.
      Test the machine. Allow the machine to build pressure with water, bleed off air. Once the system is loaded and holding pressure you want to see how long before the motor reengages to maintain pressure. Allow it to sit holding the pressure. It will stroke periodically to maintain the pressure, that is normal. The time between the strokes is what you are looking for.
      If there is a 4 second or less between strokes then there is a pressure leak in the system somewhere. More than 4 seconds and longer, then there should be no issue with pressure leaks. Watch the machine for about 2 mins and take note over that time period. Not just for the first 20 seconds.

    • @jeffhaman9010
      @jeffhaman9010 4 ปีที่แล้ว +1

      @@Brian_the_repair_guy Thank you for your reply. Very much appreciate your expertise. I repacked my 440 after watching your video just a couple of days ago. It had a small leak afterwards. I searched the comments, and took your advise to make sure the bottom nut was tight enough, and that fixed it right up. You should have a patreon or a venmo linked so that the benefactors of your videos can buy you a beer or two for your advise.

  • @brideramirez4210
    @brideramirez4210 2 ปีที่แล้ว

    My titan keeps tripping the breaker any idea what could be wrong breaker works good for everything reps saws and everything but soon as I turn the sprayer on trips the breaker

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  2 ปีที่แล้ว

      What titan are you using?

    • @brideramirez4210
      @brideramirez4210 2 ปีที่แล้ว

      440

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  2 ปีที่แล้ว

      @@brideramirez4210 unplug the motor from the board. Turn the machine on, turn the pressure up. With the board unplugged from the motor, see of the breaker trips.

  • @seacoastrising
    @seacoastrising 3 ปีที่แล้ว

    I have a 8900 Titan paint sprayer. It was purchased in July 2020. It was powered on today and very little pressure to the guns. From your video looks like the transducer. How is it replaced?

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      There is no transducer on an 8900. You have low pressure on the machine and the pressure knob is turned counter clockwise fully?

    • @seacoastrising
      @seacoastrising 3 ปีที่แล้ว

      @@Brian_the_repair_guy yes it is fully turned.

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      @@seacoastrising did you purchase the machine new?

    • @seacoastrising
      @seacoastrising 3 ปีที่แล้ว

      @@Brian_the_repair_guy yes bought it in July 2020 brand new

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      @@seacoastrising my suggestion would be take it to a certified service center. The machine is still under warranty. If you were to attempt repairs, it can void the warranty.
      With that said, check your filters from the machine to the gun.
      Does the machine stop pumping when the triggers are released?
      Do you get a burst of pressure when the trigger is pulled and then fade or is the pressure low from the start?

  • @juangallardo7712
    @juangallardo7712 3 ปีที่แล้ว

    I got a 640 titan said low voltage replace it now it don't start any idea what the problem may be ?

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว +1

      If you turn the machine off, then back on before the screen goes dark, it will say "low voltage". Tou must wait for the screen to go dark before you turn it back on.
      If this is not the problem, I would remove the surge protector from the switch and connect the switch without the surge protector. If the machine works, replace the surge protector. If these do not work, let me know and we will move forward.

    • @juangallardo7712
      @juangallardo7712 3 ปีที่แล้ว

      @@Brian_the_repair_guy thanks a lot

  • @bt8831
    @bt8831 3 ปีที่แล้ว

    Question: I picked up a titan epic and repacked with a new piston and packing; the suction valve had to be cleaned and now getting some suction: however, the motor still runs at full speed and is not priming........can this be the transducer? if i turn the transducer all the way off the motor stops......................Thoughts?

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      I do not think the trans ducer is the issue. Pull the pick up hose off, remove the pressure hose. Immerse the lower end of the pump where the pick up tube connects in water and turn it on. It should pick up the water and spray out of the pressure hose connection.
      Keep extra water handy to refill the container as it runs.
      After a couple seconds of moving water, reattach the pressure hose and repeat. Make sure to keep the water container full as it runs. Do not let it run dry.
      If the machine runs and builds pressure then stops, all is well. If the machine does not stop running and fails to build pressure, there is an issue in the pump. Keep the pressure down to about 1/3. You do not need the pressure turned high to do this.

    • @bt8831
      @bt8831 3 ปีที่แล้ว

      th-cam.com/video/Eb2LGwFqeYs/w-d-xo.html

    • @bt8831
      @bt8831 3 ปีที่แล้ว

      th-cam.com/video/8_Jgc9BIDK0/w-d-xo.html Hey Brian thanks for your help this one might help

    • @bt8831
      @bt8831 3 ปีที่แล้ว

      Hi Brian: turned out to be two things: 1. clogged foot valve used the ultrasonic cleaner; it was holding wasunder tap from both sides now clear on inlet side but holding from pump side 2. primer valve was bad too. Used one on from my other titan and it primed right away and shut off Tip for all those out there with old 440 epic.......cut and tube with clamps the intake pipe for easy removal if needed.................Thanks Brian for your help regards

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      @@bt8831 I am very glad you were able to resolve the problem

  • @richardhernandez8659
    @richardhernandez8659 5 หลายเดือนก่อน

    Hey. I have a question? Why my 1140 it doesn't turn on. Im mean its dead .

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  5 หลายเดือนก่อน

      My first thought is the transducer. Pull the cover and see if there is lights on the board

  • @jeffryhernandes6608
    @jeffryhernandes6608 2 ปีที่แล้ว

    Hi I have a problem with my graco 7900 first generation when I start spraying loss pressure but after 5 to 10 minutes pressure is good

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  2 ปีที่แล้ว

      When you say pressure loss, does than mean you begin spraying and the machine is pumping but can't keep up or you spray and the machine does not pump for a short period then begins to pump?

    • @jeffryhernandes6608
      @jeffryhernandes6608 2 ปีที่แล้ว

      @@Brian_the_repair_guy yea it’s pumping but can’t keep up but after 5 minutes it’s all good what could be the problem?

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  2 ปีที่แล้ว +1

      @@jeffryhernandes6608 could be a couple things. Check the packings and the 2 balls for damage.

  • @MrPembo15
    @MrPembo15 ปีที่แล้ว

    hin Bri love the vid dude my 495 is flashing red on the Bluetooth sign and I've took the hose of and realleist the pressure. but its still in pressure on the gauge

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  ปีที่แล้ว +1

      How many blinks before it repeats? The light will blink, then have a short pause, then repeat the blink.

    • @MrPembo15
      @MrPembo15 ปีที่แล้ว

      @@Brian_the_repair_guy just 2

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  ปีที่แล้ว

      @@MrPembo15 turn the machine off, open the prime valve and turn the machine back on. If it runs, you should be good. If it goes back to the 2 flashes, you will need a transducer.

  • @albertomendez4485
    @albertomendez4485 3 ปีที่แล้ว

    hi I have a 640 impact, and i have some liquid going through the return hose, I have change everything packings, piston rod, pressure valve. Can you tell me if it may be a transducer going bad? Machine blinks check transducer and disappear!!! it build pressure up to 125 bars (of 221) and then motor don t stop running and I have that leak by the return hose, can you help Thanks

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      If you have liquid coming from the return line then it can only be one of 3 things. Replace the prime valve, replace the transducer (excessive pressure) of the aluminum block has pressure cutting in the prime valve base (there will be a non circular hole in the base of the prime valve block).

    • @albertomendez4485
      @albertomendez4485 3 ปีที่แล้ว

      @@Brian_the_repair_guy Thank you so much Brian, now i am pretty sure its the transducer as it say check transducer and when i tried to spray it was saying High Pressure....last thing to change

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      @@albertomendez4485 I hope this helps. Good luck.

  • @joshlittleton7423
    @joshlittleton7423 2 ปีที่แล้ว

    Just replaced to switch on my tighten 840 can’t remember how the wires plug into the back black on top white on bottom or white on top black on bottom if anybody help let me know

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  2 ปีที่แล้ว

      The whites go on one side top and bottom the black goes on the other side one on top and one on bottom

  • @TheIpadiphone
    @TheIpadiphone 4 ปีที่แล้ว

    I have a Titan IMPACT 1140 in the display it’s showing low voltage and I’ve plugged the machine to a different outlet but still nothing, any ideas what it could be?

    • @georgezeins1958
      @georgezeins1958 3 ปีที่แล้ว

      Did u figure it out? I'm having the same problem right now.

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      Sorry I did not see your message. I sincerely apologize.

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      @@georgezeins1958 I didnt notice your message. Have you resolved the issue?

    • @georgezeins1958
      @georgezeins1958 3 ปีที่แล้ว

      @@Brian_the_repair_guy No problem, I'm almost certain bad rocker switch. Found a way to make it work tho. What I have been doing is leaving the rocker switch on the on position at all times. Just plug it in and unplug lol.

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      @@georgezeins1958 ok. I get lots of questions and half never give a notification. So I have to scroll through all messages on all videos. I am glad you are up and running.

  • @chancenebeker4481
    @chancenebeker4481 ปีที่แล้ว

    i have a 490 would it be the same thing?

  • @mrfajita1542
    @mrfajita1542 4 ปีที่แล้ว

    What is the main sign of bad transducer in a Graco 695,?hi

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  4 ปีที่แล้ว +1

      Depending on the age of the machine you can get different signs.
      Newer unit, you will get an error code of E02 or E03
      Older, take the cover off the control box. Turn the machine on. There is an LED that will blink 2 or 3 times then pause. Then repeat the blink.
      If you don't have this, turn the machine on and prime. If the motor does not turn on, the transducer could be bad. If the motor turns on and your pressure goes very high the transducer could be bad. If the pressure goes low and the motor stops even when the pressure is turned high, the transducer could be bad.

  • @maximodiaz5016
    @maximodiaz5016 3 ปีที่แล้ว

    Hi I have a titan I'm not sure what model but it's a high boy the rental ones, maybe 440 the motor turns on and piston moves like its working but would not pump, can u help me please

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      Did this just happen? Was it working properly and then just not pick up? Has it been sitting up unused for a few weeks or more?

    • @maximodiaz5016
      @maximodiaz5016 3 ปีที่แล้ว

      It was sitting in the storage for more than 2 years

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      @@maximodiaz5016 I have a video titled loss of pressure. Take a look at that, try what I show and see if that fixes the problem.

    • @maximodiaz5016
      @maximodiaz5016 3 ปีที่แล้ว

      @@Brian_the_repair_guy thanks man I will check that video out

  • @enduro7722
    @enduro7722 3 ปีที่แล้ว

    I have a switch on/of for a epx2155 I did pull it ut but i can remember how the wires goes and the manual is confuse

    • @enduro7722
      @enduro7722 3 ปีที่แล้ว

      If you can help let me know

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      @@enduro7722 is it a 4 wire or a 2 wire switch?

    • @enduro7722
      @enduro7722 3 ปีที่แล้ว

      @@Brian_the_repair_guy 4 wires thanks for answering

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      @@enduro7722 black and white wire from the power cord attach to the top of the switch. Black and white wire to the board attach on the bottom of the switch. White over white, black over black

  • @mikelujan5141
    @mikelujan5141 3 ปีที่แล้ว

    Hey Brian I bought a Titan impact 440 on ebay in October last year when I got it I turned it on it worked so I put in the closet until I got a full time job to use it when I did it started smoking and then it blew the circuit breaker on the pump what can I check to fix it I have a 3/4 inch wrench

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      If you have smoke, you either have bad brushes of bad motor. Depending on the model.

    • @mikelujan5141
      @mikelujan5141 3 ปีที่แล้ว

      @@Brian_the_repair_guy Titan impact 440 model 805-016 thank you where would I buy brushes ?

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      @@mikelujan5141 most Sherwin William's can order them or any certified repair shop. I have seen many places online, but I wont suggest any of them

  • @jessedolan9158
    @jessedolan9158 3 ปีที่แล้ว

    hi hows it going i have a ultra max 2 lowboy looks same as 1 u r working on i change transducer new 1 n still doesnt power up i did all procedures brushless motor good all is good but transducer thats what code i got n troubleshooting came too like i said new n stll no go any ideas ???

    • @jessedolan9158
      @jessedolan9158 3 ปีที่แล้ว

      btw no code no more after i changed it no codes at all but still no go ???

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      @@jessedolan9158 you have a Graco Ultra max 2. What model? You replaced the transducer and the motor has no power? Are there any lights on the board?

    • @jessedolan9158
      @jessedolan9158 3 ปีที่แล้ว

      @@Brian_the_repair_guy hi Brianso its a graco ultra max 2 490 smart control 2.0 i beleive they call it a stand model i thought it was a low boy which it isnt it doesnt have the wheels lol i no the motor is good i tested it out n have resistance in it with every combination blk 2 red blk 2 blu red 2 blu so i no that that end of it is good at 1st i did have a light flashing i beleive it was 3 if im not mistaken which was transducer so i ordered 1 up put it in no code flashing anymore but still no go go n i tryed every way they tell u to do in the step by step troubleshooting snakes n ladders game of instructions lol what im not getting is it says if there isnt the right pressure it wont start now i no im not the brightest can of checkered paint out there but i no 1+2=12 n as i c it if u need the right pressure 4 it 2 run shouldnt the motor turn on ?????? 2 get 2 the right amount of pressure lol; ???
      i got it outta the garbage bin at my buddies job site it was running he came in next morning n wouldnt go mind ya his SOB puppy making employees dont no how to clean anything n it was plugged up solid i took it apart cleaned her up n got everything like brand new 2nd hand loln thats when i seen light flashin n like i said earlier changed part no code flashin no more nothing flashing at all n like i said i went threw all steps n it all good took apart boards n tested caps resistors etc etc n from my knowledge it all seems to test out ok ?????? idk bro im stumped im a mechanic not a painter sorry house painter sorry mechanic/bodyman/painter jack of all trades master of none lol any word of wizdom u can guide me to common lil problems with them tricks of the trade ???? n all ppl that i know that r painters n use these fine quality tools say it should go if no codes n all tests well ??????

    • @jessedolan9158
      @jessedolan9158 3 ปีที่แล้ว

      @@Brian_the_repair_guy if u have messenger maybe be a lil easlier that way to talk idk but ya just facebook me on messenger Jesse Dolan my pic is just me got a mohawk no shirt tattoos on neck n chest cant m,iss it lol

  • @AlexLopez-dt5gx
    @AlexLopez-dt5gx ปีที่แล้ว

    Hey Brian my uncle wants to repair a titan 640 what happen is that he plug it in a house where there was something wrong with the electricity and almost everything burned from the inside of the display

    • @AlexLopez-dt5gx
      @AlexLopez-dt5gx ปีที่แล้ว

      And some pices brake down I would just like to see how is it from the inside and the pieces I need for the machine thenks

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  ปีที่แล้ว +1

      @@AlexLopez-dt5gx this would be very hard to tell you what to replace. There is a surge protector behind the display, that will most likely need to be replaced first

  • @canal10sp
    @canal10sp 2 ปีที่แล้ว

    I have a problem with titan 440i I don’t know if is the case to replace the translucent sensor. The sprayer hold pressure only with water when I switch for paint it not pressure at all. Anyone can help me out? 😃

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  2 ปีที่แล้ว

      This would not be a transducer problem. When you say it holds pressure with water but no paint does this mean your machine will run, prime, build pressure and STOP running only with water?

    • @canal10sp
      @canal10sp 2 ปีที่แล้ว

      @@Brian_the_repair_guy The machine was used daily. Maintenance was done regularly. When I use the machine I always wash it with water first and then I switch for the paint.With the water the machine works normally and when I switch to the paint the machine does not hold the pressure.

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  2 ปีที่แล้ว +1

      @@canal10sp so with water, the machine will build pressure and stops running and does not run again until you pull the trigger or open the prime valve under full preasure?

  • @dylanizac1
    @dylanizac1 ปีที่แล้ว

    Hey guy...good day to you! I have a graco 695 with the self cleaning gun attached feature. (Never used it). Just sprayed 72 gal fine...loosing pressure on last 8. Pumps up to 950-1250 then stops. Went through everthing... found you transducer video but have that cleaner mechanism, unlike your example here. Any ideas for me? Thanx for your videos brother!

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  ปีที่แล้ว

      If you set the pressure control to maximum and the pressure is less than max and the machines stops pumping, then you most likely have a transducer problem.
      I would attach an analog gauge if you have one to ensure the screen display is correct.
      The transducer is the cheapest and easiest solution as well as the likely problem. The alternative is the control board or slight possibility the potentiometer.

    • @dylanizac1
      @dylanizac1 ปีที่แล้ว +1

      No error codes...

  • @Maria-Corona
    @Maria-Corona 3 ปีที่แล้ว +1

    how do i find out the pressure transducer model number on my 795.the only numbers i see on part 2-223

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      Not sure which model 795 you have. The most common model of 795 uses part number 243222.
      If you look on the ID plate and get one of these; model number, part number or unit number from the machine then I can tell you the part number for the transducer.
      More than likely it is the number I provided above.

    • @Maria-Corona
      @Maria-Corona 3 ปีที่แล้ว

      @@Brian_the_repair_guy graco 795 serial#BA510 series#B03A part#245022 this was the info under the airless .now that im here i also have a 455 serial#BA374 series#C00A part#232-931 what repacking kit do recommend for this type. thanks for the help.

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว +1

      @@Maria-Coronathe Transducer is 243222. The packings are 244194 but are now listed as 18B260 for the 455.

    • @Maria-Corona
      @Maria-Corona 3 ปีที่แล้ว

      @@Brian_the_repair_guy thanks brian great help i really appreciate.i will write down this info for my future we just never know when old blue here might need it again. ive owned my 455 for 20 yrs me old blue have seen alot and plan on seeing lot more after i repack it thanks to your videos...ive always paid for service on old blue but we will make an exception thanks you!thanks again

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว +1

      @@Maria-Corona no problem. I am glad to help. Be sure to subscribe.

  • @jorgesolis5236
    @jorgesolis5236 3 ปีที่แล้ว

    Hey man I seen your Transducer video really good man it helped me out. But can you make it a little bit more clear? I have a 440i & my motor light is not turning on & the pressure is not working at all what do I need to change on it boss?

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      Is the motor running at all?

    • @MarcosOliveira-fw9gv
      @MarcosOliveira-fw9gv 3 ปีที่แล้ว

      @@Brian_the_repair_guy I'm in the same situation, the motor is working but no pressure enough !
      😥 you think is transducer ?
      Thanks..

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      @@MarcosOliveira-fw9gv no, it wouldn't be the transducer. The transducer would either give you too much pressure, or low pressure. If you have no pressure, then the first thing I would check is the upper or lower ball. Make sure there is no obstruction. If you are not sure how to check this, let me know and I can make a video on how to check it.

    • @chrismccrea6043
      @chrismccrea6043 ปีที่แล้ว

      @@Brian_the_repair_guy
      My titan 440 is not working.
      It has a solid yellow or orange light on.
      I turn the pressure switch up and down and get nothing.

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  ปีที่แล้ว

      @@chrismccrea6043 have you replaced the transducer? That would be the first thing I would look at.

  • @mckjimmy3802
    @mckjimmy3802 4 ปีที่แล้ว +1

    Hi mate the protection knob on top of the pressure control box seems jammed.
    Can I fix this.

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  4 ปีที่แล้ว

      I am not sure what the "protection knob" is. Could you clarify exactly what part you are referring to?

    • @mckjimmy3802
      @mckjimmy3802 4 ปีที่แล้ว

      Hi mate sorry predictive texting. Arrgghhhh.
      The pressure control box has the switch and the pressure control knob.
      I bought a graco GM3500.
      The knob won’t turn. It looks kind of corroded but in place there’s not a lot of room to try free it.

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  4 ปีที่แล้ว

      @@mckjimmy3802 to be clear, the pressure control knob will not rotate? Your pressure does not increase or decrease, correct?

    • @mckjimmy3802
      @mckjimmy3802 4 ปีที่แล้ว

      Brian Shumack correct

    • @mckjimmy3802
      @mckjimmy3802 4 ปีที่แล้ว

      Pretchiometer

  • @brushbrothers3758
    @brushbrothers3758 5 ปีที่แล้ว +1

    I’d like to see one of a motor replacement specifically 640 impact titan

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  5 ปีที่แล้ว +1

      I will make a video this week on a 640 Impact motor replacement

    • @brushbrothers3758
      @brushbrothers3758 5 ปีที่แล้ว

      Brian Shumack I just love your videos man very instructional. Might seem like a silly question but when you redo the brushes how do you reattach them back

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  5 ปีที่แล้ว +1

      @@brushbrothers3758 I use a butt joint splice. Crimp it and heat shrink

    • @brushbrothers3758
      @brushbrothers3758 5 ปีที่แล้ว

      Brian Shumack thanks bud

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  5 ปีที่แล้ว

      @@brushbrothers3758 no problem

  • @seacoastrising
    @seacoastrising 3 ปีที่แล้ว

    i will take the machine in tomorrow to an authorized repair shop. i will post the end results to help others.

  • @laurorodriguez2160
    @laurorodriguez2160 2 ปีที่แล้ว

    Sir I really need your help I have a graco 390 that motor is not running I tested the motor with a 9v battery and fan is working that means motor is good I replaced pressure control board and still not working do you think pressure control switch could be the reason that my sprayer won’t start thanks a lot hope you answer

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  2 ปีที่แล้ว +1

      Have you checked the fuse?

    • @laurorodriguez2160
      @laurorodriguez2160 2 ปีที่แล้ว

      @@Brian_the_repair_guy yes fuse is good and brushes olso that’s why I asked you if pressure control switch could be a reason to motor won’t start thanks a lot for responding

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  2 ปีที่แล้ว

      @@laurorodriguez2160 grab a paper clip. Bend it so the 2 ends are close together side by side. Unplug the pressure control from the board. Insert the bent paper clip. Plug the machine in and turn the machine on. If it runs, the pressure control is bad. If it still does not run, then the board is bad. Make sure the paper clip is NOT touching any part of the machine.

    • @laurorodriguez2160
      @laurorodriguez2160 2 ปีที่แล้ว

      @@Brian_the_repair_guy okay after bent the paper clip I have to insert the two ends of paper clip in the two Orefice of pressure control wire

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  2 ปีที่แล้ว +1

      @@laurorodriguez2160 you will insert the paperclip into the clip on the board where the pressure control attaches

  • @aveumartinez9167
    @aveumartinez9167 2 ปีที่แล้ว

    My 695 starts and shuts off...Can l run the sprayer with out the transfucer just to check if the motor runs

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  2 ปีที่แล้ว +1

      The motor will not operate without a transducer.
      Tell me exactly what is happening

    • @aveumartinez9167
      @aveumartinez9167 2 ปีที่แล้ว

      Thanks again for the time to reply....stars but turns off after maybe 5 sec.... l put a transducer after market but its doing thesame

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  2 ปีที่แล้ว +1

      @@aveumartinez9167 disconnect the hose from the pump section and turn the machine on. Does it run or stop?

    • @aveumartinez9167
      @aveumartinez9167 2 ปีที่แล้ว

      I been doing it with no line on it

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  2 ปีที่แล้ว +1

      @@aveumartinez9167 not your pressure hose. The line on the back of the pump or fluid section. Disconnect that one

  • @russelljenkina4960
    @russelljenkina4960 5 ปีที่แล้ว

    GOOD MORNING, THANKS FOR THE VIDEO ...I HAVE A AIRLESSCO 540 AND IT HAS A TRANSDUCER AS WELL,MY QUESTION IS THE PRESSURE ON THE DIGITAL STAY ON AT 1500 PSI AND WILL NOT TURN ON UNTIL I MOVE THE PRESSURE KNOB ABOVE THE 1500 PSI AND THAN IT WILL TURN ON AND HOLD PRESSURE ALL THE WAY TO 3300 PSI BUT WHEN I GO TO TURN BACK DOWN TO LOWER SETTING TO 1500 PSI IT TURNS OFF AGAIN.... CAN THIS BE A TRANSDUCER PROBLEMOR SOMETHING ELSE/ IT WORKS FINE AND HOLDS PRESSURE ABOVE THE 1500 PSI , THANKS!

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  5 ปีที่แล้ว +1

      The only wau to know what pressure you have is with a pressure gauge. I would check tjat first and make sure you are getting 3000+ psi at max. If not, then more than likely you have a transducer problem.

  • @rafaelherrera5710
    @rafaelherrera5710 ปีที่แล้ว

    Anybody know how to replace the power cord?

  • @ismaeltrinidad4439
    @ismaeltrinidad4439 3 ปีที่แล้ว

    Hi i have a 640 and i replace transducer and dont control pressure it builds highly pressure wath woulb be the problem

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      You replaced the transducer with a new one and the pressure is building very high?

    • @ismaeltrinidad4439
      @ismaeltrinidad4439 3 ปีที่แล้ว

      Yes the new one dont control the pressure thanks for reaching

    • @ismaeltrinidad4439
      @ismaeltrinidad4439 3 ปีที่แล้ว

      It builds very high yes I have to turn if of

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      @@ismaeltrinidad4439 if you turn the pressure knob down, will the pressure drop?

    • @ismaeltrinidad4439
      @ismaeltrinidad4439 3 ปีที่แล้ว

      @@Brian_the_repair_guy no it doesn't soon as i turn pressure on it keeps building will not stop unless i turn knob to 0 pressure

  • @spackspuiten715
    @spackspuiten715 2 ปีที่แล้ว

    Hi , maybe you can tell me how you can replace a circuit board for a graco 695
    The old one is all glued
    Tnx

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  2 ปีที่แล้ว

      The board that is glued in requires complete replacement. What makes you feel the board is bad?

    • @spackspuiten715
      @spackspuiten715 2 ปีที่แล้ว

      @@Brian_the_repair_guy because if I turn the sprayer on , he is doing nothing.
      He turns on but nothing happens.
      Is it possible that it is something else?
      Btw Tnx for your response and your time

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  2 ปีที่แล้ว

      @@spackspuiten715 when you turn the machine on, there should be lights on the board. Do the lights come on? If they do, is there flashing? If it flashes, how many times before it repeats?

    • @spackspuiten715
      @spackspuiten715 2 ปีที่แล้ว

      Hi it flashes 3 times and then again

    • @spackspuiten715
      @spackspuiten715 2 ปีที่แล้ว

      Can it be the transducer?

  • @brushbrothers3758
    @brushbrothers3758 5 ปีที่แล้ว +1

    Can you do a video replacing the brushes

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  5 ปีที่แล้ว

      I have a video in the can. Just looking for better software to edit for You Tube. Be sure to follow, you will be notified when it is released.

    • @brushbrothers3758
      @brushbrothers3758 5 ปีที่แล้ว

      Brian Shumack I hope so. Need to do it soon plus I miss your vids man

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  5 ปีที่แล้ว

      @@brushbrothers3758 yeah You Tube is a pain when is comes to publishing videos.

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  5 ปีที่แล้ว

      Brushes for Graco or Titan?

    • @brushbrothers3758
      @brushbrothers3758 5 ปีที่แล้ว

      Brian Shumack Titan 640 impact

  • @joettebarreras7195
    @joettebarreras7195 3 ปีที่แล้ว

    Have a titan 740i is it normal if it gets hot

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      Exactly what is getting hot?

    • @joettebarreras7195
      @joettebarreras7195 3 ปีที่แล้ว

      @@Brian_the_repair_guy the housing around the motor. fan is working

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      @@joettebarreras7195 is it too hot to touch?

    • @joettebarreras7195
      @joettebarreras7195 3 ปีที่แล้ว

      @@Brian_the_repair_guy almost .gana pull the housing make sure its getting enough air

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  3 ปีที่แล้ว

      @@joettebarreras7195 clean the over spray off the motor. Spin the fan and make sure it is not slipping on the shaft

  • @markgonsoulin2852
    @markgonsoulin2852 2 ปีที่แล้ว

    440. pressure recovery normal and will hold. when trigger is pulled pressure slowly drops. release trigger pressure rebuilds normally. ??? I'm thinking transducer. Yea -Nay?

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  2 ปีที่แล้ว

      The difference in set pressure and pressure drop is called the dead band. If your dead band exceeds about 200 psi I would look directly at the transducer first. If you have a 440 IMPACT, then there is also a circuit board under the machine that could be the problem. There is no way for you to know which. My suggestion is replace the transducer and see if it corrects the problem. If it does, then happy days. If it does not, then replace the pressure control board under the IMPACT series and save the new transducer for later.

    • @mdmd-mf3bg
      @mdmd-mf3bg 2 ปีที่แล้ว

      @@Brian_the_repair_guy @Mark Gonsoulin got the same issue titan 440 impact.... it runs at full bore when the knob is set at its last 2 highest settings no issue.... but at lower setting it sprays and slowly loses all pressure at gun then builds back up like if it where a pump quirt gun

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  2 ปีที่แล้ว

      @@mdmd-mf3bg my first go to is the transducer. If that isn't the fix, it would be the pressure control board under the impact machine

  • @tomhepple1799
    @tomhepple1799 2 ปีที่แล้ว

    Titan 740, starts for a second then stops, What could that be

  • @tevinthompson4676
    @tevinthompson4676 4 ปีที่แล้ว

    Have a sprayer that has no power to the motor

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  4 ปีที่แล้ว

      Which sprayer?

    • @tevinthompson4676
      @tevinthompson4676 4 ปีที่แล้ว

      Its the titan 440

    • @Brian_the_repair_guy
      @Brian_the_repair_guy  4 ปีที่แล้ว

      @@tevinthompson4676 my first thought would be the transducer. If it is not working, it will not activate the motor. Depending on the model, the brushes may need to be checked.

  • @alexroberts7641
    @alexroberts7641 5 หลายเดือนก่อน

    Don’t pry the pump out like he says.