How to use a ductulator?

แชร์
ฝัง
  • เผยแพร่เมื่อ 7 ก.ย. 2024
  • I have to use a ductulator on almost every job estimate that I go to.
    Air Flow is the Number 1 problem in the HVAC field..
    FPM Feet Per Minute is measured with a anemometer
    CFM Cubic Feet Per Minute is 350 to 400 CFM per ton residential
    Static Pressure/Total External Static Pressure measured with a Magnehelic
    are all super important.
    HVAC Videos
    How to size Ductwork?
    • How to Size Ductwork?
    How to size HVAC Equipment?
    • How to size HVAC Equip...
    HVAC Tools I use
    Yellow Jacket 42004 Series 41 Manifold with 3-1/8" Gauge
    amzn.to/3yaYAd3
    Fieldpiece SC440 True RMS Clamp Meter with Temperature, Inrush Current, Capacitance and Backlight
    amzn.to/3SNaC4e
    Fieldpiece - TC24 - Pipe Clamp Thermocouple
    amzn.to/3ftVWbD
    Fieldpiece SPK2 Folding Pocket in-Duct Thermometer
    amzn.to/3HlEH7h
    Fieldpiece SC440 True RMS Clamp Meter
    amzn.to/3PP7XVQ
    Fieldpiece SRH3 In-Duct Digital Psychrometer
    amzn.to/3wuPZki
    Testo Digital Pocket Vane Anemometer
    amzn.to/3RJypkJ
    Ductulator
    amzn.to/3UVt78d
    Join this channel to get access to perks:
    / @taddydigest
    Wanna learn more about hvac? Check out my hvac tips for technicians playlist.
    • HVAC Tips for Technicians
    Taddy Digest Website
    taddydigest.com/
    Click this link to get your website consultation.
    moderncontract...
    Modern Web Studios has Built, hosted and maintained my Website.
    modernwebstudi...
    Fill out the contact form at modern web studios
    modernwebstudi...

ความคิดเห็น • 86

  • @junjun972
    @junjun972 8 หลายเดือนก่อน +16

    0.1 friction loss to calculate supply duct size and .05 friction loss to calculate return duct size

  • @Parabellum-X
    @Parabellum-X 3 หลายเดือนก่อน +2

    This is the best video on How To Use a Ductulator, the shortcut method.
    Hands down.
    Unless you're trying to do a Manual J with its Heat Load calculations, Total Effective Lengths, and Friction Loss bullshit in all of its glory, this is the way to go.
    Either method has the same output; it just depends how much time and money you want to spend on it (and the software).
    Some people will argue that you need to set a particular static pressure. While that is true, to some degree, there is also a small range of static pressure available that you have to play with. It all depends on the design specs of that indoor blower motor, and how loud/quiet you want that unit to run when you're finished.
    Experience alone is the only thing that's going to enable you to find that sweet spot that you prefer when installing the ductwork that you choose to install.

  • @danamyrocket
    @danamyrocket 6 หลายเดือนก่อน +1

    After spending 35 years in engineering, while using only SI units, it’s still shocking to encounter “freedom“ units in the wild. Thanks for this video. It’s nice to see a professional using the right tools for the job. Keep up the good work.

  • @joshl90
    @joshl90 3 ปีที่แล้ว +8

    I used one of these in engineering school when I took an HVAC design class. Was a super useful tool

    • @TaddyDigest
      @TaddyDigest  3 ปีที่แล้ว +1

      Wow very cool Josh 😎
      Engineering School sounds fun

  • @andrewmcdonald4519
    @andrewmcdonald4519 ปีที่แล้ว +7

    I usually use .01 friction loss at 500 cfm per ton for heat pumps, 400 cfm per ton for ac only, for return if your velocity is higher then 500fpm you will blow the water off the coil in cooling but like what you did my friend , Q=VA, you can check your equation cfm on equipment before u start, CFM=Btu output/1.08*delta t before you start a project as well

    • @MmxiXciv
      @MmxiXciv 7 หลายเดือนก่อน

      what is *delta.?

    • @loganswadley5332
      @loganswadley5332 7 หลายเดือนก่อน +1

      * is for multiplying instead of using the x symbol. And it’s delta t - for temperature difference between supply and return

  • @andrewmcdonald4519
    @andrewmcdonald4519 ปีที่แล้ว +5

    Usually on most air handler there will be a maximum external static pressure stamped but that take into account evap coil loss, cabinet loss, and filter loss, the static using a manometer cannot exceed that or you may have to reduce speed or gain speed of blower depending, most installation manuals have a chart and when you figure out your total external static with a manometer at least you know where ur sitting

  • @MinaFahil
    @MinaFahil 4 หลายเดือนก่อน +1

    I am learning lot with you , you are my best teacher.thanks

    • @TaddyDigest
      @TaddyDigest  4 หลายเดือนก่อน

      Thank You for watching

  • @TonyRodriguez-ok2ix
    @TonyRodriguez-ok2ix 3 หลายเดือนก่อน +3

    the air conditioning system is only as good as the air distribution that its serving.

  • @kevinpearce3281
    @kevinpearce3281 ปีที่แล้ว +1

    I really need to start knowing this kinda stuff

  • @luotero8473
    @luotero8473 2 ปีที่แล้ว +2

    Thank you for helping me with understanding this a lot better.

    • @TaddyDigest
      @TaddyDigest  2 ปีที่แล้ว

      You're welcome I'm so glad that you watched and I'm glad that you learned.
      Continue to learn you will be thankful for the result

  • @JLV-l4c
    @JLV-l4c ปีที่แล้ว +2

    Great work thank you so much buddy. God bless you. Super helpful.

    • @TaddyDigest
      @TaddyDigest  ปีที่แล้ว

      You're welcome
      Glad it was helpful

  • @robertpalmatier2699
    @robertpalmatier2699 9 หลายเดือนก่อน +1

    Trimmed the beard Tad! Nice.

    • @TaddyDigest
      @TaddyDigest  9 หลายเดือนก่อน

      You know it!

  • @ducharmehvactraining925
    @ducharmehvactraining925 7 หลายเดือนก่อน +1

    good job, thanks Tad

    • @TaddyDigest
      @TaddyDigest  7 หลายเดือนก่อน

      You're welcome my brother

  • @Review-This
    @Review-This 7 หลายเดือนก่อน +1

    This helped a lot thank you.

    • @TaddyDigest
      @TaddyDigest  7 หลายเดือนก่อน

      You're welcome my friend thank you so much for watching

  • @biblebloopers946
    @biblebloopers946 2 ปีที่แล้ว +3

    My way of learning is like a domino effect. If I don't get the very first thing then everything else doesn't matter.
    At the beginning you said you use .05
    That's the part you kind of just went over real fast. So what is that 0.5? Is that what the air handler or furnace total external static pressure rating is? I'm not sure what that .05 is referring to
    Thanks

  • @Papasquatch73
    @Papasquatch73 3 ปีที่แล้ว +1

    I use the ACCA one. It separates metal, duct board and flex.

  • @JDT738126
    @JDT738126 ปีที่แล้ว +1

    Great videos Tad

  • @karelalonso3875
    @karelalonso3875 11 หลายเดือนก่อน +2

    Good afternoon, why we use 0.5?

  • @donaldpape1435
    @donaldpape1435 7 หลายเดือนก่อน +1

    Why are you using .05 friction loss? If you calculate tel and asp the math usually leads to .08 to 1.3 friction loss for determining the size of the ductwork. I'm curious where you get such a low friction rate(metal duct?).

  • @r.llynch4124
    @r.llynch4124 ปีที่แล้ว +1

    how to size supply when the blower is in middle of the house? 3 bedrooms 1 bath in one end 1 bath, kitchen/living room in other end

  • @TonyRodriguez-ok2ix
    @TonyRodriguez-ok2ix 3 หลายเดือนก่อน +2

    easy piezzy lemon squeezy

  • @sdsd4284
    @sdsd4284 ปีที่แล้ว +1

    Ran across this vid u mentioned RT FPM SHOULD NOT BE MORE THE 500 ,HOW DO U ADDRESS THAT ISSUE IF IT IS MORE THE 500 ?

  • @arthurterrazas4816
    @arthurterrazas4816 ปีที่แล้ว +1

    Great info

  • @cookieAC
    @cookieAC 2 ปีที่แล้ว +2

    Hey Tad. Great videos! Could you let us know why you've decided to use .01 instead of .05? On another brand of equipment it says to use .2 I know to follow specs for each equipment. But I'm just curious

    • @TaddyDigest
      @TaddyDigest  2 ปีที่แล้ว +2

      Hey Caleb Thank you for watching 👀 😀 I can definitely make a video about static pressure and manufacturers equipment.

    • @cookieAC
      @cookieAC 2 ปีที่แล้ว

      @@TaddyDigest that's awesome! Look forward to watching brother. You have a excellent way of explaining

    • @jesrudder1988
      @jesrudder1988 2 ปีที่แล้ว

      Great video boss!

  • @nohmadbaker5449
    @nohmadbaker5449 4 หลายเดือนก่อน +1

    Thanks! This video helped me

    • @TaddyDigest
      @TaddyDigest  4 หลายเดือนก่อน

      Glad it helped!

  • @RISHIRAJ-xc7tu
    @RISHIRAJ-xc7tu 3 ปีที่แล้ว

    Pl advise best software or manuals
    Round / circular process duct calculation including, Expansion joint, Stiffner, development, pressure drop, Load calculation on each support

  • @maxrovira7315
    @maxrovira7315 9 หลายเดือนก่อน +2

    Hi tad where can I get a book like this reading material

    • @TaddyDigest
      @TaddyDigest  9 หลายเดือนก่อน

      Check out the link in the description

  • @karelalonso3875
    @karelalonso3875 11 หลายเดือนก่อน +1

    ¡Gracias!

  • @ajbeck2121
    @ajbeck2121 5 หลายเดือนก่อน +1

    Why not calculate your actual FR?

    • @TaddyDigest
      @TaddyDigest  5 หลายเดือนก่อน

      On existing jobs, you should
      When you're planning on building duck work for your job, you have to have an FR.

  • @ricardoleslie9811
    @ricardoleslie9811 2 ปีที่แล้ว +1

    From my understanding, odd number duct sizes require a custom job, but this was not covered in the videos

    • @ricardoleslie9811
      @ricardoleslie9811 2 ปีที่แล้ว +2

      custom orders

    • @TaddyDigest
      @TaddyDigest  2 ปีที่แล้ว

      Yeah usually there is square duct which has to be custom built or round pipe you can get all the fittings you need for that at most supply places
      I have a In depth video on diy ductwork if your interested

    • @ricardoleslie9811
      @ricardoleslie9811 2 ปีที่แล้ว

      @@TaddyDigest From my classes in this area, it was suggested that instead of going for the odd number, size up or down by one unit.
      As money was usually an issue, it was normal to size down one unit. Example, instead of using a 13", one would size down one unit to 12" or up one unit to 14". As it is cheaper to size down one unit, in this example, 12" would be chosen instead.

  • @travisanderson6127
    @travisanderson6127 ปีที่แล้ว +1

    Wouldn't reducing pipes mess with the fps just like water pipes when you reduce it it ads pressure

  • @martinheatingcoolingmartin4693
    @martinheatingcoolingmartin4693 ปีที่แล้ว +1

    Hey there,
    What if it’s only for heating? A new gas furnace, single zone, 60,000 btus. I know all my room dimensions and requirements . I’m adding heat for the first floor only, ducted. Do you still go by tonnage? I’m m trying to figure my trunk size. I’m sure it’s the total of all the taps down the line. Plus I need the specs on the furnace I’m sure.

    • @martinheatingcoolingmartin4693
      @martinheatingcoolingmartin4693 ปีที่แล้ว

      Basically, in short, my question is, isn’t that CFM for cooling return what is CFM for heating BTUs?

    • @martinheatingcoolingmartin4693
      @martinheatingcoolingmartin4693 ปีที่แล้ว +1

      Scratch the word return that was voice texting. I know is that CFM for COOLING. What is the CFM for HEATING?

    • @TaddyDigest
      @TaddyDigest  ปีที่แล้ว +1

      I'll do a video about this in a week or so

  • @justinbelleville1392
    @justinbelleville1392 3 ปีที่แล้ว +2

    How do you size ductwork where each room requires a specific CFM based on the Manual J? Currently using Cool Calc and some rooms require specific CFMs.

  • @coolramone
    @coolramone ปีที่แล้ว +1

    How do you determine supply plenum size?

  • @Karnol428
    @Karnol428 ปีที่แล้ว +1

    So I’ve been trying to figure this answer out for a couple days now. Why do you use .05? And I hear others use .1 and others .01. What factors go into choosing your friction loss?

    • @jodykershaw7701
      @jodykershaw7701 ปีที่แล้ว +1

      A load calculation needs to be done. Then you need to figure out what your ASP available static pressure. Then you must figure your TEL Total equivalent duct length. Then you take that ASP and multiply it by 100 then divide that by your TEL that gives you the correct Friction rate for the system being designed. All these other people using .05, .01, .1, etc are just playing the guessing game and giving that customer a generic factored system that will never be effective nor efficient!

  • @reno5939
    @reno5939 2 ปีที่แล้ว +1

    Is the static pressure different from sheet metal to fiberglass duct?

  • @ernestoignaciovierasifonte714
    @ernestoignaciovierasifonte714 2 ปีที่แล้ว +1

    Great !!!

  • @riazmalik2956
    @riazmalik2956 2 ปีที่แล้ว +1

    How do you place this particular anemometer to measure the velocity?

    • @TaddyDigest
      @TaddyDigest  2 ปีที่แล้ว

      I have another video you should check out that show you how

  • @JC-sc9rx
    @JC-sc9rx ปีที่แล้ว +1

    You said you used to use .01 for static pressure now you use .05. What prompted the change?

    • @TaddyDigest
      @TaddyDigest  ปีที่แล้ว +1

      went from R22 to 410A

    • @JC-sc9rx
      @JC-sc9rx ปีที่แล้ว +1

      @@TaddyDigest different refrigerants cause different static pressures in the duct work?

    • @JC-sc9rx
      @JC-sc9rx ปีที่แล้ว +1

      @@TaddyDigest I'm still new so I'm trying to figure out how to find and set static pressures when using a duculator..

    • @TaddyDigest
      @TaddyDigest  ปีที่แล้ว

      duct sizes increased with the change in equipment

    • @JC-sc9rx
      @JC-sc9rx ปีที่แล้ว +1

      @@TaddyDigest ahh. The static pressure is set to what you would like it to optimally be

  • @tttota5421
    @tttota5421 3 ปีที่แล้ว +2

    If we have 800 sf house and we have 2 rooms 1 living room , 1 bathroom,and 1 laundry room,and we have 1.5 ton unit how we gonna calculate the amount of air for each room and how many returns we need ?

    • @TaddyDigest
      @TaddyDigest  3 ปีที่แล้ว +3

      Good question I need to do a video to be able to explain this
      I will do a live video or a recorded video very soon

  • @eugeneb3682
    @eugeneb3682 ปีที่แล้ว +2

    Romans 8:31
    if God is for us who can be against us?

  • @biblebloopers946
    @biblebloopers946 2 ปีที่แล้ว +1

    I'm visiting this video again. Very frustrating watching this.
    You used to use .01
    You now use .05
    Others use .08
    and even others use .1
    Whatever you choose will dramatically change the size of the duct.
    So without any explanation of why you choose .05 when you use to choose .01, I am left more confused than ever.
    So I guess we could pick what we want? I pick....hmmmm 🤔🤔🤔... I pick 3.5. heck why not?
    Do you get where I'm going with this? I like your videos but nobody really truly explains this part.

    • @TaddyDigest
      @TaddyDigest  2 ปีที่แล้ว +1

      I will do a video and explain my friend

  • @quengaskhan7171
    @quengaskhan7171 2 ปีที่แล้ว +1

    Thanks man 🤙🏽

    • @TaddyDigest
      @TaddyDigest  2 ปีที่แล้ว

      your welcome 🙏 🤗 ☺️

  • @jodykershaw7701
    @jodykershaw7701 ปีที่แล้ว +1

    Where is your load calculation? Where is your ASPx100 divided by your TEL to get your correct friction rate. You are giving those people bombed information. Got to do better if you are going to try to give other tech’s advice man!

  • @jodykershaw7701
    @jodykershaw7701 ปีที่แล้ว

    Where is your load calculation? Where is your ASPx100 divided by your TEL to get your correct friction rate. You are giving those people bombed information. Got to do better if you are going to try to give other tech’s advice man!

    • @TaddyDigest
      @TaddyDigest  ปีที่แล้ว

      A load calculation is a great idea and it's a must
      I have more videos where I speak about Such load calculations
      Really appreciate you sharing your knowledge my friend.