Duct Sizing Explained - Why Ducts are undersized sometimes

แชร์
ฝัง
  • เผยแพร่เมื่อ 5 ต.ค. 2024
  • In this video, Joshua Griffin explains a few theories and misconceptions when it comes to duct sizing. The hope is with more understanding of how ducts are sized, homeowners and contractors alike will not have any issues when sizing ductwork and understanding why certain sizes are significantly larger, or only somewhat larger. Joshua uses a graphic to show the differences between a 6, 8, 10, and 12-inch duct. He also explains the CFM levels of each size and the understanding of a 6 vs a 12-inch round duct.
    To purchase the ductulator that Josh shows in this video, click here: amzn.to/419urIr
    For more information on New HVAC Guide, visit www.newhvacgui...
    *Need Financing for your HVAC? Visit www.newhvacgui...
    *Own a Service Biz and want to grow? Visit www.newhvacgui...
    *******Our favorite products?*******
    Favorite Air Filter here: spn.so/l/j7tyujh1
    Favorite Thermostat click here! amzn.to/4eluZ3F
    Favorite Air Cleaner here: amzn.to/3JuWfyU
    Air Tester/Monitor here: amzn.to/3oJ3LvD
    Dehumidifier here: amzn.to/3ZIdOVp
    Humidifier here: amzn.to/4eGJOO4
    Smart Vent here: amzn.to/3JDfGDX
    HVAC Soft Start: amzn.to/3kMXlwT
    HVAC Guide for Homeowners is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program to provide a means for sites to earn advertising fees by advertising and linking to amazon.com. Amazon offers a small commission on products sold through their affiliate links. Each of your purchases via our Amazon affiliation links supports our cause at no additional cost to you.
    Griffin Air and Joshua Griffin have partnered with Daikin on multiple projects. FTC requires disclosure of these relationships due to the compensation received.
    #hvac #ductwork #ductsizing

ความคิดเห็น • 39

  • @AudiophileTommy
    @AudiophileTommy 10 หลายเดือนก่อน +8

    Can you do a video on return sizes ? Thanks !

    • @NewHVACGuide
      @NewHVACGuide  10 หลายเดือนก่อน +4

      I’ll add it to the list! 🙂

  • @waalwink
    @waalwink 3 หลายเดือนก่อน +1

    Flow is directly related to cross sectional area. A little bit of geometry says the cross sectional area is pi times the radius squared. This is why air flow is not linear related to the diameter.

    • @Steven-mm7gb
      @Steven-mm7gb 2 หลายเดือนก่อน

      And static pressure.

  • @allandavis6116
    @allandavis6116 หลายเดือนก่อน

    So for 4 ton system - it generates a flow of 1600 cfm - so off the main box I should have, for example 4 10'' ducts = 4x400 cfm, or 2 12'' ducts and 1 10'' duct = 2*600 + 1*400 = 1600 cfm. Then at the room vents there could be 8 8'' ducts = 8*200 = 1600 cfm. Correct?

  • @brianchadwick9405
    @brianchadwick9405 10 หลายเดือนก่อน

    I have always used the NCI cheat sheet. Until complicated systems need technical details.

  • @Inkling777
    @Inkling777 10 หลายเดือนก่อน +2

    For ductwork in unconditioned space wouldn't a small duct with a powerful enough fan push the air through quickly enough to reduce the loss of heating or cooling and thus save money?

    • @ironmatic1
      @ironmatic1 5 หลายเดือนก่อน +1

      The pumping energy required to overcome the increased friction loss would far offset any negligible thermal loss.

    • @Steven-mm7gb
      @Steven-mm7gb 2 หลายเดือนก่อน

      the higher the static pressure the noisier it gets also

  • @jordapen
    @jordapen 10 หลายเดือนก่อน

    My new Daikin mini split sydtem has been working well, but there has been times when it is set to 22 C, it can only make it 21 C. The temperature had been -6 C, and it could hold 22C, then a week later when it it was - 6 C again, it could only hold 21 C. The contractor has checked it out, and found things in order. He will be back with his diagonistic device to check out the circuitry.

    • @ABChgdyhh
      @ABChgdyhh 6 หลายเดือนก่อน

      Open your manual and check minimal temperatures for this unit. Also check how much square footage you have in that room , multiple it by 30 and compare it to unit BTUs. Probably it would be lower than your unit

    • @jordapen
      @jordapen 6 หลายเดือนก่อน

      @ABChgdyhh I've made a lot of headway since then. It involved moving things to give the downstairs unit unrestricted airflow for both intake and output. Also, if it is going to get very cold, I set the temperature up to 24 C, and it now will maintain 22 C right down to -12 C. It hasn't gotten any colder to try it at a lower temperature.

  • @marksatalino2225
    @marksatalino2225 5 หลายเดือนก่อน

    Looking for a good hvac company in Nassau county forced air. Not getting enough air in the second floor bedrooms.

  • @trainsdawgz
    @trainsdawgz 4 หลายเดือนก่อน +1

    I was told my duct work is too small for the tonnage of my system and that this would cause damage to the system. They recommend new duct work. Does this sound right? Thank you!

    • @peterdarlington4117
      @peterdarlington4117 3 หลายเดือนก่อน +1

      Yes, ma’am, if it truly is undersized, it will destroy your system

    • @peterdarlington4117
      @peterdarlington4117 3 หลายเดือนก่อน +1

      And your electric bill

    • @Steven-mm7gb
      @Steven-mm7gb 3 หลายเดือนก่อน +1

      you wont get enough flow of air across the coil and it will gather ice, freeze up and then no air will flow can set fan speed to high but your unit will only produce so much static pressure and may not be able to push the air. If you increase static pressure more air will flow through a smaller duct

    • @Steven-mm7gb
      @Steven-mm7gb 3 หลายเดือนก่อน +1

      rule of thumb is 1 cfm per sq foot so can figure out if your tonnage of cooling and duct correct size and can use duculater to confirm duct size per room...400 cfm per ton of cooling

    • @raymondblakley3731
      @raymondblakley3731 10 วันที่ผ่านมา

      Yes true I went to one that had a dryer duct attached to the system

  • @dnell6854
    @dnell6854 10 หลายเดือนก่อน

    Great video!!

  • @enriqueramirez6199
    @enriqueramirez6199 10 หลายเดือนก่อน +1

    Why not size the ductwork to the system recommended static pressure? .05

    • @Steven-mm7gb
      @Steven-mm7gb 3 หลายเดือนก่อน

      rule of thumb 1 cfm per square foot

    • @JOIHIINI
      @JOIHIINI 2 หลายเดือนก่อน

      ​@@Steven-mm7gbfrom what I've seen the friction rate to have 1cfm per square foot would have to be well below .05 for supply which would be on longer ductwork applications. In shorter ducts friction rate can be around the 1 range which would make those ducts way oversized. It'd be the difference between a 6 and an 8 round

    • @JOIHIINI
      @JOIHIINI 2 หลายเดือนก่อน

      Coil + filter takes away about .15 before it leaves the gate

    • @Steven-mm7gb
      @Steven-mm7gb 2 หลายเดือนก่อน

      @@JOIHIINI I think my original post left out what i meant to say , "rule of thumb 1 cfm per square foot" I should have said ....rule of thumb 1 cfm per square foot of room size, duct should be sized to the room served. This info given to me 35 years ago when I started the trade in Commercial Sheet metal from multiple HVAC engineers as a rule of thumb for my home system. 1cfm per SQ foot of area in a room. These are professional cal poly graduates with engineering stamps.

    • @JOIHIINI
      @JOIHIINI 2 หลายเดือนก่อน

      @Steven-mm7gb yeah I figured u meant room size in the first place. Just seems like a lot, I don't have that experience tho. I was just sizing a central heat pump unit and they rate a 4 ton for 1500-2000 square feet but 1cfm per square foot would only work on the very low end of that spectrum

  • @sensen3095
    @sensen3095 11 วันที่ผ่านมา

    Can someone explain this in electrician terms?

    • @convictednotconvinced
      @convictednotconvinced 11 วันที่ผ่านมา

      There are certainly parallels between fluid mechanics and electrical theory, and I'll do my best to make some of those connections, however I don't think that's the best way to explain what's at the core of this. First off, the relationship of duct size to CFM is the fluid mechanics version of Olms law. A pressure is exerted on some fluid (air in this case) which is the equivalent of Volts., the system has some intrinsic resistance to the motion of the fluid, the Olms equivalent, and the proportion of these two will determine the current, CFM in this example, and Amperes in electrical... thank you captain obvious! This is all about selecting the appropriate conductor AWG based on current requirements, voltage drop, environmental factors, blah blah blah.
      Just like with different wire gages, duct size inversely changes the resistance component of the equation, and while total resistance to air flow is a sum of many factors (impedance in electrical), friction caused by air molecules rubbing against the interior sides of the duct is the major source of the resistance. The reason the change is nonlinear has to do with a simple concept in geometry, specifically the ratio between the circumference of the duct and its cross sectional area. Interestingly this same concept, but in three dimensions, is the reason the cells in our bodies have to be small.
      So as the duct diameter increases, it's cross sectional surface area increases at a faster rate than the length of circumference, and since surface area dictates CFM while circumference/ perimeter dictates resistance, not only is the CFM increasing but so is the efficiency. Your buying your CFM in bulk and therefore getting a better price. In the case of our cells, the ratio of cell surface area to volume is important because water and nutrients are absorbed through the cell walls in order to feed the cell volume. For this purpose smaller is better such that there is ever increasing area for absorption while having to sustain an ever decreasing amount of volume. You can prove this yourself by calculating the the surface area and circumference of a circle given a random diameter, and then take the ratio of the two. You see how that ratio changes with its radius and that's all that's happening here.
      - Whew fuck! Time for work.

  • @jevells
    @jevells 3 หลายเดือนก่อน

    Now how do you k ow what cfm you need/vent/sqft?

    • @Steven-mm7gb
      @Steven-mm7gb 2 หลายเดือนก่อน +1

      rule of thumb 1 cfm per square foot of living space...can adjust for a full sun or no insulation etc..

    • @jevells
      @jevells 2 หลายเดือนก่อน

      @@Steven-mm7gb thank you!

  • @joew6107
    @joew6107 3 หลายเดือนก่อน +1

    I don't see how a 6 in, carrying 100 cfm, can transition a 8 in, and then there is 200 cfm. Wouldn't the 6 in restrict the flow to 100 cfm? Where did the additional 100 cfm come from?

    • @mrteuy
      @mrteuy 2 หลายเดือนก่อน

      You’re increasing the cross section which cfm increases due to the volumetric increase. Velocity changes (slows) that will affect the time of moving air giving you the cubic feet per minute.

    • @JOIHIINI
      @JOIHIINI 2 หลายเดือนก่อน

      ​@@mrteuyit just seems odd. By that logic I could run a 6 inch, increase that to 8, then branch to 2 6 inches a foot later and there would be 100cfm at each 6 inch?

    • @jeffb6276
      @jeffb6276 หลายเดือนก่อน

      Keep in mind, I don't know a lot, but his measurement is with the same static pressure in thr 6 and 8 inch supply, which to my under educated guess means the 8 inch gets a bigger blower to create the same pressure within the system as the smaller blower with the 6 inch. He's not saying just swap the duct diameter, he's saying bumping up to an 8 inch system, which brings the volume from 28 square inches to 50 square inches (I'm writing this just as much to retain it as to help)

    • @JOIHIINI
      @JOIHIINI หลายเดือนก่อน

      @jeffb6276 in a standard system though the ducts branch off a large trunk so I don't really get the blower size thing. The trunk is sized based on the required cfm the unit can provide and then the duct runs are distributed based on the cfm of the trunk. From what I can tell this logic is pretty much saying you could have a 6 inch get the same air flow as an 8 inch which just doesn't make sense. Then you may as well have a 6 by 6 trunk and branch off of it. The static pressure is obviously important but it doesn't make a difference if the duct is too small, and the unit itself has a max static pressure that it can operate at so you can't really increase it that much to make up for loss in sizing to deliver that cfm.

    • @howardsmith5474
      @howardsmith5474 หลายเดือนก่อน

      To answer your question it doesn’t. He is only talking about maximum capacity of cfm of each size pipe. I am not aware of a situation where you would start with a 6” pipe and then increase the size downstream of the air handler, in fact its the opposite- it gets smaller because with each branch off your main trunk the cfm requirement goes down.

  • @kennethbubser9601
    @kennethbubser9601 10 หลายเดือนก่อน

    .07 supply .05 for return .07 now code in nj

    • @NewHVACGuide
      @NewHVACGuide  10 หลายเดือนก่อน +1

      Nice. That’s not a bad thing.