-6°F Out... Now They Both Don't Have Heat

แชร์
ฝัง
  • เผยแพร่เมื่อ 17 ต.ค. 2024

ความคิดเห็น • 273

  • @MaximumEntropyLLC
    @MaximumEntropyLLC ปีที่แล้ว +26

    "It's negative 6 today and I'm not wasting time.... " hahahahahaha... Stay warm my friend!

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +8

      I edited so much out of this video 😂... Your not hearing a 1/10 of what I said.

    • @ryans413
      @ryans413 ปีที่แล้ว

      Normal day in Canada actually it gets colder then that’s believe it or not. Right now it’s really warm for January it’s 15 Fahrenheit about -10 Celsius

  • @chaseherigstad8576
    @chaseherigstad8576 10 หลายเดือนก่อน +3

    I appreciate that you don’t sugar coat anything. I can empathize with your thought process, and have learned quite a bit from you. Between you and Chris from HVACR, you guys saved my bacon in my first couple years. Hard to imagine you can get mentors from TH-cam.

    • @HVACRSurvival
      @HVACRSurvival  10 หลายเดือนก่อน

      Thanks Chase, I needed a little boost when I got into refrigeration full time and NorCal and Jim Pettinato were my helpers.

  • @chatrkat
    @chatrkat ปีที่แล้ว +14

    That’s beyond brutal, I’ve worked up on my roofs over the last 30 years as a tech fixing other than mechanical equipment. You do just what is required to make it work. No deluxe repairs when it’s that cold.

  • @pizzapale
    @pizzapale ปีที่แล้ว +6

    2:57 gotta make sure to kick some fresh snow over that yellow snow to hide the evidence this time of year 😂😂

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +2

      Normally I do but I forgot to cut that out...lol

  • @MileticPVP
    @MileticPVP ปีที่แล้ว +5

    The good old quick piss on the roof @ 5:20 . I'm always having to piss at the worse time too lol

    • @m9ovich785
      @m9ovich785 ปีที่แล้ว +2

      I usually look for a vent Pipe or a Roof Drain and Pee down that.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +5

      No one's going up there other than the 10,000 plus viewers that have watched it😂

    • @Rollerguitar96
      @Rollerguitar96 หลายเดือนก่อน

      its 60‘000 now! :D - even from switzerland

  • @Brisket9392
    @Brisket9392 ปีที่แล้ว +5

    "Obviously you can't leave it like this unless you wanna die." Good stuff. LOL.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      I'd have the HVAC TH-cam police on me if I didn't say it🙈🤣

  • @MikeB9771
    @MikeB9771 ปีที่แล้ว +12

    For a while there I thought that old furnace was just toying with you. One thing I hate is having to brave the cold to get others warm. Good job Rick.
    Would love to see the unedited version of this video.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +8

      You would think differently about me after seeing it. I had to cut a lot of shit out.

    • @donaldpainter956
      @donaldpainter956 ปีที่แล้ว +2

      @@HVACRSurvival I know your frustrations I had a couple of those outbreaks myself over the weekend

    • @jsmith7286
      @jsmith7286 ปีที่แล้ว +1

      @@HVACRSurvival I personally love rheem furnaces but I have had my run around with the ol 90% Achievers. No doubt the pressure issues are trouble.

  • @watermanone7567
    @watermanone7567 ปีที่แล้ว +3

    Thanks for a good video. I changed a compressor for a computer room on Christmas Eve. many years ago in an alley way up on a mezzanine .It was about 10F. Never again. Thanks

  • @markh.6687
    @markh.6687 ปีที่แล้ว +2

    Nice work! Especially the Scotty "I can jury-rig the furnace, but I canna tell ye how lang it will last, Captain!" job in that basement.

  • @stephenwolinski4651
    @stephenwolinski4651 ปีที่แล้ว +3

    Mikey pipes said hvac is the road to riches , days like this give me a second thought on that 🥹

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +2

      Depends where you are and what you charge.

  • @michaelcoonts6253
    @michaelcoonts6253 ปีที่แล้ว +2

    I worked through that winter storm as well. Was at a kfc with no heat. One unit went off on roll out when birds nest that was in it caught fire. Lol😂

  • @roberthayes6654
    @roberthayes6654 ปีที่แล้ว +3

    Yeah been doing hvac for 25plus years . Have to do what you have to do in this cold. New subscriber stay warm brother..

  • @Kangenpower7
    @Kangenpower7 ปีที่แล้ว +3

    During the hour long drive to get parts, the home warmed up to 58F 15C, it will take a long time to reach a comfortable 68F or 20C.
    With certain Cities wanting us to install the very smallest furnace to keep the home warm, they seem to forget on very cold days it will take hours to reach a comfortable temperature when starting at 30F. My guess is that the home has very little insulation between the very cold basement and the living space? That does not help at all!
    If they have a electric stove, I would recommend running the oven, but not with a gas oven.

  • @carolinafrog4365
    @carolinafrog4365 ปีที่แล้ว +3

    totally sucks to be out there in that kinda weather doing that kinda work, but Thank You for being The Man with The Plan and The Skills to git r dun! i can only imagine what a man of your skill will be able to earn in another 10yrs as the industry ages up with less ppl to fill the need!

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      Thanks frog, there is a lot to learn and not enough people willing to learn it is a real issue👍👍

  • @coldking8383
    @coldking8383 ปีที่แล้ว +2

    My hat goes off to you Rick! Was 33 degrees here in Florida -I didn’t even want to get out of bed. But work never stops ……..Stay warm

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +2

      😂😂33*👍👍. That's perfect weather, but we would go broke if it didn't get cold like it does.

    • @TheFrenchPug
      @TheFrenchPug ปีที่แล้ว +1

      50 here in So Cal and I'm not getting out of bed. Lol

  • @spencerdelossantos9373
    @spencerdelossantos9373 ปีที่แล้ว +8

    anyone notice the yellow snow at 5:28 ..... haha

    • @throttlebottle5906
      @throttlebottle5906 ปีที่แล้ว +1

      blame it on a flying roof dog... 🤣

    • @jgren4048
      @jgren4048 ปีที่แล้ว

      I did at 3:26

    • @paulbryant68
      @paulbryant68 หลายเดือนก่อน

      haaaaa!!! did now!!! thats def me! gota go!

  • @leosthrivwithautism
    @leosthrivwithautism ปีที่แล้ว +2

    I am beyond grateful for all who work in HVAC. And service contractors too. Long story short I want on vacation in the mountains during Christmas. The Well pump was frozen shut when the heater breaker tripped out on the pump. So No water for a week. And half way through, the Aux. Heat on the AC tripped out too. Very nice sleeping in a cabin that was 48 degrees at night. The heat pump just couldn't keep up. The people called where not happy but we understood and provided them with some food to show gratitude otherwise the entire Trip would of been ruined for us in a frosty cabin.

    • @leosthrivwithautism
      @leosthrivwithautism ปีที่แล้ว +1

      The Pump company was scheduled out over a week in advance. The owner begged them to place this as emergency and even so they where still out more than 3 days due to the large number of emergencies and low number of crews available. HVAC company was more than 3 weeks booked out. And Emergency calls where the same. This cold causes a really bad situation for everyone in those fields.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      Thanks for sharing your story, I'm glad they were able to get it going.

  • @stevencossaboon3237
    @stevencossaboon3237 ปีที่แล้ว +5

    Great work Rick. I hope you and the family had a good Christmas. Stay warm brother.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      Thank you, hope yours was as well! It was good 👍. I'm very blessed.

  • @rcstl8815
    @rcstl8815 ปีที่แล้ว +2

    For those playing along at home... make sure the port at the inducer casing is clear. It is the first place for FOD (like drywall dust), to try to get out and if blocked, even partially, It will not have the draw to close the pressure switch(es). If it is clogged, it will make the switches look bad. I carry small bits, orifice sized, to clear the port.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      That's why I checked the actual draft being created by the IDM with the monometer, it was about 50% higher than needed to close the switch.

    • @rcstl8815
      @rcstl8815 ปีที่แล้ว +1

      @@HVACRSurvival When the port is restricted, it will not allow enough suction to pass quick enough to close the switch. The draft will look great but it can't draw through the port orifice. I had a spider web stop one, the kind of spider that clogs grill orifices.

  • @Djcarp83
    @Djcarp83 หลายเดือนก่อน +1

    It’s a Rheem the heat exchanger is stainless so failure is very low with them

  • @Eddy63
    @Eddy63 ปีที่แล้ว +2

    I admire all you guy's that brave this kind of weather ... My hat's off to you ... I almost feel guilty enjoying a cold 🍺 and a shot of Tequila ... I said '' Almost '' 🤣😅😂 Thx Rickster

  • @jhill.7216
    @jhill.7216 ปีที่แล้ว +2

    Oh my ! Man oh man I’m about to Graduate hvac school upcoming may 2023 ! I’m from the south but this is absolutely something watching this! Thanks for what you do 👏🏽👏🏽

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      Congrats! I appreciate the feedback!

    • @markh.6687
      @markh.6687 ปีที่แล้ว +1

      Don't worry; with climate change soon you'll be working in snow and cold as well as heat and humidity down South.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      @@markh.6687 yep we're all gonna die 7 years ago thanks to stupid humans living on earth👍👍.

  • @randomrefrigeration4564
    @randomrefrigeration4564 ปีที่แล้ว +2

    Enjoy your videos Rick
    Just watched one on the Generac with lose throttle screw and bad compression
    Man your super thorough
    Appreciate you man

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      Thanks for the feedback! I have a lot of different types of videos if you liked those.

  • @fredlogan3849
    @fredlogan3849 ปีที่แล้ว +1

    tHANKS FOR THE WARNING LOL

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC ปีที่แล้ว +1

    I don't miss the cold and snow....i moved to TX from Buffalo....so i definitely know about the cold and snow. We had 1 day, that was cold (13°) the rest have been 60°+. Today was 75° and glorious.....sorry wasn't trying to rub it in.....well maybe a little bit. Lol. Great video as always Rick.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      lol I was inside all day today and it was warm at 35*

  • @philipmariaegeanga7984
    @philipmariaegeanga7984 ปีที่แล้ว +2

    sometimes pressure switches shows good in tester but due to carbonization on contacts they dont really close the circuit when in operation same as amplifier relays they dont have an output yet when you test them they are ok

  • @joehead1294
    @joehead1294 ปีที่แล้ว +2

    Got cold in Texas, 16 degrees F. Lennox heat pump kept up, 79 degrees for my mum. She's 90 years old.

  • @retsbew8954
    @retsbew8954 ปีที่แล้ว +2

    Thanks for the videos. BTW, I ordered that exact same manometer from Tru-tech using your code. Keep up the great work!

  • @Willy12927
    @Willy12927 ปีที่แล้ว +1

    I know it is an efficiency thing, but they make everything so complicated. You would think that someone could manufacture a simple, high efficiency furnace. During my 75 years on this earth I can't remember having to have a service call on a furnace. All that was required was to change the air filter and an occasional fan belt. Also, the blower fan and motor had oil cups, which if oiled periodically, would very rarely fail. Hey, times change, and I guess we have to be thankful that there are people like you that understand these new systems and are willing to brave the elements in order to keep us warm in the winter and cool in the summer.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      Thanks for checking it out Willy!

  • @theunit5939
    @theunit5939 ปีที่แล้ว +1

    Wow crazy how the flue was not glued in, playing with fire on that one,

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      Not really, I rather see it siliconed then glued for easier service.

  • @ianicus123
    @ianicus123 ปีที่แล้ว +1

    Man working like that with the blower running, risky wow.

  • @hugh007
    @hugh007 ปีที่แล้ว +2

    Great video. Thanks. Your alligator clip lead looks just like the ones I used years ago from Western Electric. Looks like the same label too.
    Happy New Year.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      I built them from silicon test leads and added my name on a label.

    • @markh.6687
      @markh.6687 ปีที่แล้ว +2

      "Keeping your phone system the best in the world" -- Bell System ad slogan, 1970's. I just took a photo of an old Bell System ground-level buried cable tag on a utility pole; most of it was still readable. Quality?? THAT was quality!

  • @christopherkidwell9817
    @christopherkidwell9817 ปีที่แล้ว +3

    Bad thing is that many people who call in for their next fuel delivery like myself are at a higher chance of running out of fuel due to the cold snaps making us use much more fuel.

  • @jasontexter1721
    @jasontexter1721 ปีที่แล้ว +2

    So I know on the nests, idk about the ecobee, but if you jumped out red to white or yellow or green it would cause the thermostat to error out, and it would open the circuit. They use transistors/solid state switches instead of mechanical relays and they read the resistance/voltage drop on the circuit and when you jump it out it freaks them out and they'll lock out when you change resistance it was used to seeing

    • @jasontexter1721
      @jasontexter1721 ปีที่แล้ว +1

      The nests are notorious for the cooling circuit failing if you have a loose connection to the contactor or any chattering that can cause high amp draw on the y wire or even if it's trying to run a large contactor or multiple contactors or had any thing close to a short to ground it would fry the transistor/solid state relay. So when you read voltage at the contactor control side it when it's connected you'd get 50-500 MV but if you disconnect and read sometimes it would be 9-24V but the current carrying capacity would be severely reduced when it fails. I think they even list the maximum amps each control leg coming out of the nest at like 200-500 MA and it's a hard rating... I've even had a sticking reversing valve fry one once that was a kick in the butt, after changing the valve and getting ready to run in cooling nothing happens 🤣🤣

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      You would think it wouldn't be like that being these technically are not a power stealing thermostat because they have a common wire but this was a huge issue when they didn't have Commons required. The old power stealing stats were able to be powered off just r&w, total pieces of crap usually, I wouldn't be surprised if they used a capacitor to keep the display up and going while that circuit was closed.

  • @Boodieman72
    @Boodieman72 ปีที่แล้ว +2

    Bearings on my house furnace sounded like that and within 2 days it locked up and ended up with a whole new furnace.

  • @vampirel1983
    @vampirel1983 ปีที่แล้ว +2

    Great video Rick. I just replaced a pressure switch on one of my houses because it throws a code saying switch is bad and i can visually see the error. I still couldnt quite follow how you determine the one on the left is faulty. is it because that one is on the pressure switch circuit? so the one on the bottom will never be a problem?

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      Because only one of the pressure switches were on the pressure sensor circuit, the other one just broke power to the gas valve.

    • @JP-sd2cw
      @JP-sd2cw ปีที่แล้ว +1

      @@HVACRSurvival hey sorry to bug you I was trying to understand this as well

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      The best way to check a pressure switch is to put a tee in line with the pressure switch and draft motor, then measure it with a manometer. If you're lucky the pressure switch will have a rating on the side of it, you normally want to be one and a half times more than what it is rated at but that's just something I've noticed. You definitely don't want to be right at the rating.

  • @thesilentonevictor
    @thesilentonevictor ปีที่แล้ว +1

    Good touch on the old lady Rick

  • @shifter8207
    @shifter8207 ปีที่แล้ว +2

    I had to take many a piss on the roof this week too😂😂😂

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      There's something about the cold that brings it out🤣

    • @joehead1294
      @joehead1294 ปีที่แล้ว +2

      @@HVACRSurvival But you didn't autograph it.🤣🤣🤣👍

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      @@joehead1294 This was my first edit with my new computer and I had several issues, also this was my first 4k video, I stayed up until 2am correcting things that got screwed up.

    • @joehead1294
      @joehead1294 ปีที่แล้ว +1

      @@HVACRSurvival Didn't you ever write your name in the snow as a kid? 😆

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      @Joehead1294 I probably peed outside more times than I have inside, I'm pretty sure I did 😁👍👍

  • @danielprose5878
    @danielprose5878 ปีที่แล้ว +2

    Which mini splits would you recommend as a pro service mecanic in terms of reliablility and quality ? Are the daikin models a good choice ? Servus from Germany

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      Mitsubishi is what we sell, I don't like anything I have seen from Daikin

    • @danielprose5878
      @danielprose5878 ปีที่แล้ว +1

      @@HVACRSurvival Thanks. What uyou dont like on Daikin ? I thought Daikin and Mitsu are near the same quality and reliablility?

    • @natepeterson7145
      @natepeterson7145 ปีที่แล้ว +1

      @@danielprose5878 Most techs don't like Goodman which Daikin is a part of. They can be ok if this install is done properly.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      Technical support is the big thing with any of those mini splits, I don't like working on them because I don't know them very well, I do too many different things to be specialized in it. Each guy at our shop has a niche that they're really good at and that's not one of mine. Mine is the ice cream related machines and generators but even generators I'm not that great at anymore because I don't work on them very often.

  • @johnwalker890
    @johnwalker890 ปีที่แล้ว +1

    Good job Rick, Merry Christmas and Happy New Year.

  • @elBusDriverKC
    @elBusDriverKC ปีที่แล้ว +3

    Any time I take on a commercial account, or even a residential account, I start labeling everything. I service 200 units over 5 locations (large commercial buildings) and have spent a lot of time labeling the units so I don't have to guess. I craft spreadsheets and unit maps with all unit information. Don't get me wrong it definitely takes a long time, but definitely worth it.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      I fully agree, I think some people believe keeping that information hidden makes it easier to confuse others later but even if I don't have it, I'll get it eventually, people are just jerks

    • @elBusDriverKC
      @elBusDriverKC ปีที่แล้ว +1

      @@HVACRSurvival Sometimes I'm too busy, or maybe sick, and we have others go out there and work on units. I always e-mail them my unit sheets and get very cheerful responses. Keep up the good work out there!

    • @markh.6687
      @markh.6687 ปีที่แล้ว

      Looks like his paint marker froze trying to label the unit; Sharpies work better because they're alcohol-based. (Come to think of it, so are some HAVCR techs). :)

  • @4D0m45
    @4D0m45 ปีที่แล้ว +2

    3:25 yellow snow storm :D

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +2

      I forgot to cut that out... whoops 😂😂

  • @gregbowman3598
    @gregbowman3598 ปีที่แล้ว +1

    Good one Rick👍

  • @caidhg
    @caidhg ปีที่แล้ว +2

    You know a telecom tone generator/wand would be a great way to figure out which unit goes to what thermostat

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      I showed how to use a toner in an earlier video where I did just that.

  • @donaldpainter956
    @donaldpainter956 ปีที่แล้ว +2

    14 of the calls were high efficiency gas furnace the drain lines were frozen easy fix but driving around to all of them took alot of time I had bad inducer fans bad boards bad indoor blower motor bad capicater

  • @goldie1088
    @goldie1088 ปีที่แล้ว +1

    I'm having flashbacks to my Friday while watching this.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      How would you like to live inside the video...lol

    • @m9ovich785
      @m9ovich785 ปีที่แล้ว +2

      Digging Satellite Antenna's out of 3 Feet of Snow drifts too.

    • @goldie1088
      @goldie1088 ปีที่แล้ว +1

      @@HVACRSurvival unfortunately I lived it too! I'm still a pretty new service tech, only been at it for about a year. I appreciate guys like you putting up content and sharing knowledge and experience! It really helps us new guys out. Keep up the great work and thanks for all that you do!

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      @Steven cool to hear👍👍. I wish I had this tool called TH-cam back in 95. I had only a few people that were willing to help me learn, a lot of them just faked it till they made it 😂🤦🏻

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      @m9 You work for dish?

  • @harrydickson4575
    @harrydickson4575 ปีที่แล้ว +4

    Excellent work 👍👍👍

  • @EverythingHVACR
    @EverythingHVACR ปีที่แล้ว +1

    Nice job Rick! We got hit hard as well

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      Any video? It's not true without it🤣🤣🍺🍺🍺

  • @berylwhite2983
    @berylwhite2983 ปีที่แล้ว +1

    God bless you my friend no one really appreciates you like they should

  • @bassman34516
    @bassman34516 ปีที่แล้ว +1

    Yeah that day it was not fun whatsoever, it never is when it’s that cold. I spent 3/4 of it un gelling diesel reefers, trucks, jumpstarting and thawing ice in air brakes not a treat. Glad you made it through the deep freeze as well.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      Yeah that would suck too 🤜🤛👍👍

  • @ThatFlyinRyan
    @ThatFlyinRyan ปีที่แล้ว +1

    oh hell no im a florida boy i would be charging arm and legs and a Tooth lol

  • @bbasham46
    @bbasham46 ปีที่แล้ว +1

    I used to live in Columbus Ohio and I have one word of advise for you, Florida! : )

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      Yeah Columbus is only 90 minutes away, the wife won't let me leave this god forsaken state. At least for now until more things change of course I probably won't be in the field by then 🤦🏻😂

  • @marknaravas318
    @marknaravas318 ปีที่แล้ว +2

    You have a high tolerance for screechy belts and inducer motors!😊

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      A little. Probably losing some more hearing 🫣. I would have rather aligned the belt but not when it's that cold 😁

  • @ToyManFlyer1100
    @ToyManFlyer1100 ปีที่แล้ว +3

    Now, if only Auto mechanics could actually know what they doing and actually fix stuff like you do...

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +2

      If it doesn't have a computer many of them are lost.

    • @ToyManFlyer1100
      @ToyManFlyer1100 ปีที่แล้ว +2

      @@HVACRSurvival ....True dat...True dat....Auto mechanics want $100/hr to fix my car, but, in the end...It's still broken....Clueless as to what the problem is....

  • @joshwf41
    @joshwf41 ปีที่แล้ว +1

    I'm in Manitoba, Canada and -6F is nothing to me. I was out on a roof trying to fix a York this winter in -30C with a windchill of -40C(-40F)

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      👏👏👏🙌🙌🙌👍👍👍

  • @toetagsbodybags
    @toetagsbodybags ปีที่แล้ว +1

    i was on the roof on that day -28 windchill i was like running nope ok lets guess and come back later... dropped portable heaters. heating board was the issue the following week had it on the truck....... I fell ya

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      🤜🤛👍👍 your not alone🍺🍺

  • @natepeterson7145
    @natepeterson7145 ปีที่แล้ว +2

    Heat wave coming today, going to be 59. My in laws are kinda close to you and usually get our weather a day later. Beats that deep freeze from last week.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      It's 46 right now @ 8:13am est 12/29/22👍👍

  • @henrybucki7813
    @henrybucki7813 ปีที่แล้ว +2

    cut the thermostat off and see if the blower stops /make sure you number the rtu before leaving job

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      I mentioned that but cut that out of the video

  • @sterlingarcher46
    @sterlingarcher46 ปีที่แล้ว +7

    Hats off to you guys , man .
    The week before last it got to around 25-30 F and the only thing people could talk about was how " cold " it was 😄
    On a more serious note though, extreme cold is still not an excuse to be using them bloody channel locks to undo flat sided nuts Sir !!
    🤣🤣 please don't kill me ...

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +2

      You bloody Yanker! 🤣🤣🤣🤣

    • @throttlebottle5906
      @throttlebottle5906 ปีที่แล้ว

      yeah, rounded off nuts and bolts are bad 🥳

    • @jarikoltuniak1181
      @jarikoltuniak1181 ปีที่แล้ว +2

      Channel locks??! First off he's using the correct tool. A Knipex flat jaw pair of pliers that I also have in every size, you can buy four pairs of "channel locks" for the price of those Knipex. Secondly they are called slip joint pliers, Channellock brand pliers have blue handles. Channellock is a brand.

  • @walkingfreak
    @walkingfreak ปีที่แล้ว +1

    Glad i'm not the only one whos grumpier than shit in cold nasty weather.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      Nope I had to cut so much shit out of that video.

  • @mikropower01
    @mikropower01 ปีที่แล้ว +1

    That he used some oil for the motor to fix the noise of the bearings temporary, this is nice.
    But he should give the owner a list with some tips how they can improve their system.

    • @markh.6687
      @markh.6687 ปีที่แล้ว +1

      Item 1: Remove old furnace and bury in abandoned mine shaft. :)

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +2

      @Mike I know I talk fast but if you listen to what I said you'll hear me say I told the customer about it and he said it's been like that forever and he did not want it repaired beyond what it took to get it running. I don't go into all the details in the video so give me the benefit of the doubt, he also told me that he wanted to sell the house next year, not that that makes it right but there's nothing I can do if these people don't want to spend the money. How about just being glad I made the video.

  • @donaldpainter956
    @donaldpainter956 ปีที่แล้ว +1

    I did learn Rheem furnace doesn't have the safety on it. That shuts the burners off if it can't drain like a Trane and Goodman and I think carrier Rheem will back up and drain out of the furnace whoever installed this furnace put a small pan under AC coil but not under furnace so his ceiling had water pouring from it

  • @fredlogan3849
    @fredlogan3849 ปีที่แล้ว +1

    that add a wire, are never friendly when they work ok but when they do not good luck! in some cases that is all you can do, guys use 8 wire or more it helps the next tech out of a jam in the future the cost is minimal it could be you. thanks. this one was a pistil multiple issues good work

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      I agree, I prefer one or two extra conductors for future repairs or accessories

  • @donaldpainter956
    @donaldpainter956 ปีที่แล้ว +1

    That's what I tell the customer that motor is gone I'll have the office order one

  • @davidtillwach5542
    @davidtillwach5542 ปีที่แล้ว +1

    The wind-chill way colder than -6 outside.Rtu you freeze your butt off in the winter fixing them

  • @stephenbullock1443
    @stephenbullock1443 ปีที่แล้ว +1

    Good fix on the residential furnace.I never liked 90% efficiency furnace the heat exchanger fail to soon and when the warranty ends they so pricey

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      Most have a limited lifetime on the HX, at a minimum 20 years usually.

  • @throttlebottle5906
    @throttlebottle5906 ปีที่แล้ว +1

    who was chipper in that nasty howling wind and sub zero schmutz? I stayed in the house except for Christmas day, the poor old furnace here was fighting a losing battle, at one point it hit 65F inside running non stop. too many walls open and insulation out during construction work. 😬🥶

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      People can be aholes and they judge me for everything I say and I know I'm pissed off and negative while I'm doing this kind of bull

  • @roberttraylor1392
    @roberttraylor1392 ปีที่แล้ว +1

    awesome video i enjoy your video new subscriber happy holidays

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      Thanks for saying hi Robert! Thanks for the sub!

  • @donaldpainter956
    @donaldpainter956 ปีที่แล้ว +1

    I had a few calls last Friday but Saturday it started at 2 am and I worked till 11 pm Saturday night no heat calls wouldn't stop coming in

    • @guytech7310
      @guytech7310 ปีที่แล้ว +1

      The nerve of old man winter enabling a freeze right before christmas :)
      I am not in the trades, but I when to Lowes on Monday that the plumbing section was packed with people dealing with busted pipes. Lots of people still buying CPVC pipes. I am sure they be back when the next freeze hits again.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      Luckly I just ran that Friday, my on turn on call was a week or two earlier

  • @picklerix6162
    @picklerix6162 ปีที่แล้ว +3

    It’s hard to be chipper at -6 degrees. Most people wouldn’t want to get out of bed.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      What I didn't say was they cancelled work that day but we had to run the emergency calls, Its just life for a service guy but it still sucks,

  • @josht593
    @josht593 ปีที่แล้ว +1

    3:43 I bet that was cold to do ;)

  • @hvacrnortheastern2110
    @hvacrnortheastern2110 ปีที่แล้ว +1

    Great job yep nobody label any equipment l remember those days in winter not any more l operate a utility plant inside work.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      Someday I'll likely have to change over. I got a few years to go yet, God willing.

  • @jackdaniels615
    @jackdaniels615 ปีที่แล้ว +2

    If they keep the fan in auto just use the "G" wire as your common wire.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      That is an option if the customer is willing. 👍👍

    • @rambos420
      @rambos420 ปีที่แล้ว +1

      This does work

  • @chrisduck685
    @chrisduck685 ปีที่แล้ว +1

    Did you find the source of the yellow snow on the roof?

  • @donaldpainter956
    @donaldpainter956 ปีที่แล้ว +1

    I hate finding multiple units and none are marked I mean put a number on it when you install it I always label them when I either maintenance them or work on one I'll label that one then a simple number on the tstat a number on the unit

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      You're a good man 👍👍👍

  • @donaldpainter956
    @donaldpainter956 ปีที่แล้ว +1

    I agree I've found rollout switch bypassed hi limit bypassed alot of stuff the neighbor got my unit running is what they say then I tell them how dangerous they left the unit then they want to get mad

    • @natepeterson7145
      @natepeterson7145 ปีที่แล้ว +1

      People don't realize how a dead homeowner affects a business but what do we know. I bypassed an electric furnace temp cutout and learned my lesson when the customer didn't answer the phone when the part came in. Never again, don't care how cold it is. That bothered me for a while until I had to tell myself I was just trying to help someone out in - wind-chill.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      @Nate are you trying to do a confession here on the internet? Did you already do the time?

  • @SoutheastHVAC
    @SoutheastHVAC ปีที่แล้ว +1

    I don’t see how y’all handle that weather. It got down to 16° in Florida last week and I didn’t think I was gonna make it

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      Not many options but put on extra clothes and work fast.

  • @m.koehler7716
    @m.koehler7716 ปีที่แล้ว +1

    For some reason it was acceptable to reduce flues at the wall.

  • @christian4567ish
    @christian4567ish ปีที่แล้ว +1

    I saw yellow snow 😂

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      Yep, a couple people lost there minds over it.

  • @Bob.W.
    @Bob.W. ปีที่แล้ว +1

    Why wouldn't the maintenance men have diagrams of which units feed which ducts? Seems elementary.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      Each place I work at has maintenance people with a wide range of skills, some might know where everything is and others are just janitors.

  • @tonychristianson9186
    @tonychristianson9186 ปีที่แล้ว +1

    Was this in Minnesota?

  • @throttlebottle5906
    @throttlebottle5906 ปีที่แล้ว +1

    ecobee and other inline trash delete and regular t-stat on the wall, solved. the power going out while trying to diagnose it, would have made me blow a gasket 100%.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      Yeah he wanted me to pick up another one while I was getting parts, I was like aaaaa...no,

  • @liam3284
    @liam3284 ปีที่แล้ว +1

    surprised enthalpy wheels are not used

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      Normally heat recovery units are dedicated systems ducted into the system. Some places have them and others don't.

  • @billmiller5075
    @billmiller5075 ปีที่แล้ว +1

    Great job, miserable temperatures

  • @SoCaL884
    @SoCaL884 ปีที่แล้ว +1

    Wow, I was cold for you in California. COVID happened

  • @christiansommer914
    @christiansommer914 ปีที่แล้ว +2

    Time code 2:58😉

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      When you Got to go you got to Go😂

    • @christiansommer914
      @christiansommer914 ปีที่แล้ว +1

      @@HVACRSurvival true story.. I see it as my duty to mark my territory on the roofs😂😂

  • @itwasthepudding
    @itwasthepudding ปีที่แล้ว +1

    Lol i just walk outside in shorts and bare feet. It works

  • @BobKemp
    @BobKemp ปีที่แล้ว +1

    great video, where are you located with a -6 degree temp outside?

  • @mikechasse1016
    @mikechasse1016 ปีที่แล้ว +1

    Looks like someone peed on the roof! 😄

  • @matthewfasullo4983
    @matthewfasullo4983 ปีที่แล้ว +1

    Where in the states are you from?

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      Ohio

    • @matthewfasullo4983
      @matthewfasullo4983 ปีที่แล้ว +1

      Nice im in Ontario Canada I work in hvac as well I install and service water heaters. I'm thinking about doing TH-cam videos as well. What do you use to film?

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      @@matthewfasullo4983 I've used my phone and go pro the most also used the DJI action camera 2.

    • @matthewfasullo4983
      @matthewfasullo4983 ปีที่แล้ว

      Ok great thanks for the info and you probably need a video editing program as well right

  • @jeffgrant6914
    @jeffgrant6914 ปีที่แล้ว +1

    Good video 👍 buddy

  • @theashgamer400
    @theashgamer400 8 หลายเดือนก่อน +1

    what state

    • @HVACRSurvival
      @HVACRSurvival  8 หลายเดือนก่อน

      This was 2023 in ohio

  • @lilpbass
    @lilpbass ปีที่แล้ว +1

    That draft motor is NOT ok and you know it. You should have replaced. Yes I know Rheem draft motors are expensive but that thing could fail anytime.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +2

      I'll remember that next time 🤔...I'll punch the customer in the face, take his wallet out of his pocket and tell him you said your gonna replace it👍👍🤦🏻🤦🏻. People have the right to be an idiot, it's not my problem if it fails after I told him to replace it.

    • @lilpbass
      @lilpbass ปีที่แล้ว +2

      I don’t recall you stating that the customer refused the repair. I wouldn’t have commented if I knew that. After going 1.5 hrs to get a pressure switch…

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      Go back and watch it again. I said the customer said it's been doing that for a long time and he just wants to make it run and make it make heat. I didn't use proper grammar, but it is what it is and that's exactly what I said. You got a listen close, I talk fast. Why would I not want to sell him a new part?

  • @roberts.3712
    @roberts.3712 ปีที่แล้ว +1

    The heating systems are being taxed to the max during the big freeze....I don't envy your job...lol...

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว +1

      We're 35* today🤣... crazy weather!

  • @rockystelone21
    @rockystelone21 ปีที่แล้ว +1

    The extreme cold or heat will break a weak HVAC system.

  • @illestk24civic
    @illestk24civic ปีที่แล้ว +1

    Is hard to stop a trane, -6 degrees let me take care of that for ya

  • @danielprose5878
    @danielprose5878 ปีที่แล้ว +2

    WTF is this unit? it burns what ? Gas to warm the heat exchanger thats warms the air ventilated into the hotel ? Never seen some of that units here in Germany ! America is the badest Mofo in co2 emissons wow ! These units must be so ineffective in using energy ! Lossing so much on exhaust heat , blow by heat and so on . Crazy these engineers 🤣
    Your videos are nice ! And u are really a specialist service mecanic. Firms here in Germany for air conditioning, and heating would pray for specialits like you ! Really ! We have so bad problems finding good staff on these jobs. Its really bad.

    • @guytech7310
      @guytech7310 ปีที่แล้ว +1

      LOL! Germany burns coal to make electricity or imports electricity from eastern Europe coal fired plants. That's like burning a home down to keep warm! Without Russia energy Germany & most of the EU economy will be going kaputt soon!

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      BINGO Brother!

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      Wow, thanks for all the compliments after telling me how bad we are to the earth...You have to take a step back and think to yourself, are we really having all these problems from fossil fuels... & Don't forget how the government has lied about so many things. They want to control everything and I believe the energy is just another way to control us, and don't forget how your country has allowed themselves to be held over a barrel for energy,

    • @danielprose5878
      @danielprose5878 ปีที่แล้ว +1

      @@guytech7310 Man thats all right! I only meant that on these climate control units in the video. And yes after 2022 Germany does a lot Co2 too. Everything right .

    • @danielprose5878
      @danielprose5878 ปีที่แล้ว +1

      ​@@HVACRSurvival Climate change and all these problmens which come with it we have from burning fossil fuels thats clear. But yes u are right, the Government is a mess. The German Government since years ...absolute aweful horroble too.

  • @blankmans8908
    @blankmans8908 ปีที่แล้ว +1

    white vinegar works to dissolve that blue corrosion stuff

    • @throttlebottle5906
      @throttlebottle5906 ปีที่แล้ว +1

      in this case, that was likely already "acidic" corrosion, from condensate. so it would likely not do anything to it or speed up the corrosion. so you'd probably want an alkali or other neutralizer(baking soda). something far more acidic would clean it, but probably do more damage than good :)

    • @blankmans8908
      @blankmans8908 ปีที่แล้ว +1

      @@throttlebottle5906 ive used it on leaked batteries and it breaks it down pretty well makes it easier to clean off

    • @throttlebottle5906
      @throttlebottle5906 ปีที่แล้ว +1

      @@blankmans8908 small cell type batteries are often alkaline type (potassium hydroxide) which is an alkali on ph scale, and standard white vinegar is an acid on ph scale, so it neutralizes and helps clean the alkali material off. to neutralize something acidic, use something like plain baking soda or mix it into a thick paste with plain water. it will fizz and foam, possibly making a mess.(vinegar and baking soda mixed = volcanic foamy mess) lol
      always flush with plain water/rubbing alcohol afterwards.

    • @blankmans8908
      @blankmans8908 ปีที่แล้ว +1

      @@throttlebottle5906 dunno the nerd aspect im just stating what worked for me

    • @markh.6687
      @markh.6687 ปีที่แล้ว +1

      What about contact cleaner?

  • @naturekid1335
    @naturekid1335 ปีที่แล้ว +1

    Zoom spout oiler

  • @quickshticksstreaming6539
    @quickshticksstreaming6539 ปีที่แล้ว +1

    you can tell you do more comercial then residential because you were testing the WRONG pressure switch that is the condensate switch the one at the bottom was the actual primary switch and used a damn wire bursh on a board like wtf

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      Keep talking out of your ass 👍👍

    • @quickshticksstreaming6539
      @quickshticksstreaming6539 ปีที่แล้ว

      @HVACR Survival lmaoo he's mad asf I'm right. I've been doing residential hvac for 10 years and that's exactly why at the end of the video you see him replacing the black and white pressure switch instead of the all black one that his headass was testing at the start of that call imagine sounding so confused over a simple pressure switch call and ready to condem the whole damn furnace all the way from the eco bee to the slight hum on the inducer all cuz ur ass didn't want to deal with it like a man. They truly will let just about anybody do this job. And if I'm wrong then why did the all black pressure switch open and close just fine when testing with your Metter? It wasn't dropping voltage cuz the contacts were working properly on that one. Your ass went to a parts house got a universal pressure switch realized you were wrong in your diag and eventually ended up replacing the right one and just hoped we wouldn't notice hack job thru and thru just firing rhe parts cannon at it and hope it works lmao and don't get me started on u peeing on the other guys roof in the first call

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      All right, genius, obviously, you don't know how to pay attention, if you only have 10 years of experience that IS NOT a A lot of anything to brag about. NOW, if you were paying attention, and your comments tell me you were NOT! which show what a shit technician you are because you're not paying attention (LISTENING IS KEY TO BEING A GREAT TECH) to what I'm telling you in the video, but here's the facts bud. Listen good because you surely didn't listen to me in the video. That black and white switch was the one for the condensate. I never said it wasn't, what I did was use that condensate switch temporarily for the true draft motor pressure switch while I went and got him another pressure switch..... I even mentioned in the video that if the power would've went out while I was gone, the furnace would have locked out! You're such a cocky little bitch that you CANT even pay attention to WHAT WAS DOING, but you wanna run your mouth...LOL all you did was show me your a total dumbass NO credibility... The pressure switch on the condensate drain was in line with the gas valve. I even told you it was in line with the gas valve. Therefore, if it didn't open and close, it would never give you a pressure switch failure code because it's not on the pressure switch circuit. Man, I LOVE people like you because all you do is confirm I'm worth even more money than I'm already paid. GO back and watch it a few more times....I did have to mount the switches a little higher to make them fit due to the brackets not fitting the same, You can still see the correct wires are going to the correct switch. I worked for a Rheen dealer for 4 years and have done hundreds of Rheems. I can tell you right now where I stated just a few of these things I said they were at 16:02 and a 21:55. ALSO FYI the black/white switch is the condensate switch and has BLUE WIRES, The draft motor switch is ALL BLACK and has PURPLE WIRES. You can say sorry or just craw away once you go back and see I'm correct. Either way I could care less. I admit when I'm wrong but once again I had to go back and watch this carefully and write down the colors so I can be confident.... Later!