How To Set Up Multiple Motors On One Drive - A GalcoTV Tech Tip | Galco

แชร์
ฝัง
  • เผยแพร่เมื่อ 23 ต.ค. 2024

ความคิดเห็น • 16

  • @aneedahmad6130
    @aneedahmad6130 4 ปีที่แล้ว +1

    Thanks and good to see you i was looking for this video thanks once again

  • @MASAD-sw8th
    @MASAD-sw8th 2 ปีที่แล้ว

    Is this is possible in 880 VFD

  • @mosharofhossen1666
    @mosharofhossen1666 7 ปีที่แล้ว +1

    First time this devic is parameter no 0.48 cl vector and pr 0.42- 6
    pole,0.43-.920, 0.44-380, 0.45-950.Than look open and pr 1.00 write 1253
    than reset.now parameter auto setting 0.42-4pole,0.43-0.920, 0.44-400,
    0.45-1450.please help me.0.42 -2pole?

    • @GalcoIndustrial
      @GalcoIndustrial  7 ปีที่แล้ว +2

      That's because 1253 is a Standard Default configuring value. USE 1001 TO SAVE Parameters. Do you need a copy of the manual?

    • @rickywilson715
      @rickywilson715 4 ปีที่แล้ว

      Hi there I’m going back right after the meeting

  • @omnamahshivaya4611
    @omnamahshivaya4611 7 ปีที่แล้ว +1

    how to control 2 vfd by single controller I have been using 1vfd -3phase ac motor in different frequency and other one geared ac motor in other vfd in different frequency my problem start those two vfd in same time .plz tell me how start both vfd in similar time

  • @electricaltech4u45
    @electricaltech4u45 6 ปีที่แล้ว

    How to possibly in abb acs550 ???

    • @GalcoIndustrial
      @GalcoIndustrial  6 ปีที่แล้ว +1

      The principle is exactly the same, average the speed of the motors and add the FLA rating of each motor for a total current value. Remember the total current can not exceed the drive rating in amps, and you will need individual overload protection for each motor.

    • @electricaltech4u45
      @electricaltech4u45 6 ปีที่แล้ว

      Thanks allot .but both motor run in each and same time it's damage the vfd????

    • @GalcoIndustrial
      @GalcoIndustrial  6 ปีที่แล้ว +1

      As long as the total HP (motor 1 + motor 2) does not exceed the drive HP rating you should be ok to run both at the same time, ok?

    • @electricaltech4u45
      @electricaltech4u45 6 ปีที่แล้ว

      Thanks allot for your best help.galco is best.

  • @TractorWrangler01
    @TractorWrangler01 7 ปีที่แล้ว

    How do I hook up 2 dissimilar 3ph motors to run off a single VFD that is converting a 50 amp 220 single ph supply to 220 3ph and run them at the same time? Need to run 1hp and a 1/8 hp motor running at the same time without having to spend $700 on 2 seperate motor starters?

  • @joseluissalasesteban3732
    @joseluissalasesteban3732 5 ปีที่แล้ว

    I have a scheineder electric driver it has the second motor option and l have programmed the settings required by the driver, but when a switch it for the second motor any command is received in the driver. Could you tell me please what could be happening to my driver?

  • @mohammadmobin6971
    @mohammadmobin6971 7 ปีที่แล้ว +1

    can you please tell me how to run/ take motor trial on siemens drive mm440/siemens mc/siemens vc drive by Siemens pg using drive monitor
    pleaSe revert me

  • @agent70vids3
    @agent70vids3 ปีที่แล้ว

    I cant run two motors at the same time with one vfd, I need to run one motor first, once it reaches the setpoint speed, that is the time I will run the next motor.

  • @Good-Enuff-Garage
    @Good-Enuff-Garage 4 ปีที่แล้ว +1

    I did not hear a words she said, yes I am a pig