Current Transformer Polarity Test || Hindi
ฝัง
- เผยแพร่เมื่อ 28 ต.ค. 2022
- Hello friends,
Welcome to insight tecs, in today's video we are here with current Transformer Polarity Test.
Let us know if you have any queries in comments below.
keep watching 👍
also, you will get other equipment testing in the link provided below.
like, battery, transformer,
• Testing of Equipments
Hello friends,
Welcome to insight tecs, in today's video we are here with current Transformer Polarity Test.
Let us know if you have any queries in comments below.
keep watching 👍
also, you will get other equipment testing in the link provided below.
like, battery, transformer,
th-cam.com/play/PLx0rjIgzpjZnhEV2CnRwWVqJkiK86hfDu.html
Sir You Show at first that if the current flows from P1 to P2 than in secondary current will flow from R1S2 to R1S1 which is correct.
But in practical we saw that if current flowing from P1 to P2 than in secondary current flowing from R1S1 TO R1S2 & galvanometer is also showing +ve deflection.
This is i think incorrect you may check once and reply please
You have the best way to teach in simplest way
Super se bhi uper
Thanks Sir 🙏🙏🙏🙏🙏🙏🙏
Thank you Sir
Excellent knowledge distribution 🤗
Thank you for the wonderful videos
Thanks sir
Thanks 🙏
So simple method to explain
Gr8
thank you for your words...
this gives us inspiration for making more informative article....
Namaskar, your every video is so unique. Really easy to understand.
thank you for your words...
this gives us inspiration for making more informative article....
1) verification of terminal marking and polarity test
2) power frequency dry Western test in primary winding (HV)
3) power frequency Western test on secondary winding (3kv)
4) intertain over voltage test
5) determination of error
6) partial discharge measurement test
7) measurement of capacitors and Ten Delta test
8) temperature rise test (sample test)
9) lightning impulse test (sample test)
Good information sir
Please update video on acb relay settings selection
Vcb relay settings selection
Please make video for PT polarity test if it so in Hindi . thank You sir.
🤝
Great. Thank you sir
Nice explanation
Sir please make video on ct hv test
🙏 Thankyou Sir ji 🙏
Transmission line ke baare mein bataayein
Sir You Show at first that if the current flows from P1 to P2 than in secondary current will flow from R1S2 to R1S1 which is correct.
But in practical we saw that if current flowing from P1 to P2 than in secondary current flowing from R1S1 TO R1S2 & galvanometer is also showing +ve deflection.
This is i think incorrect you may check once and reply please
Thank u sir . Kindly make a video on testing of sensitivity and stability of REF protection of transformer
Sir, PT testing video provide.
Please make testing commissioning of all substation equipment
Vahi kar raha hu, testing karne do phle
Sir, can you make a video about the design of the current injection kit?
kindly watch
th-cam.com/video/nyrVofZ_Guk/w-d-xo.htmlsi=HJvwtZBDWIkrOs-U
@7:50
Please make a video on drawing study of MR V ,CTR ,CIRCUIT BREAKER (ABB,SIMENCE),MARSHALLING BOX etc .please sir
CT ok hi ya failed es test se pata chal ja ta kay sir ji
Sir pt ka polarity test kaise kre ?
Sir which principle we use to check ct Polarity
Sir other methods if not available gelenometer
think like "rencho" you will get something...
you need mili amp. meter
Sir, registance & loop registance.
Thank you sir