Hello friends, In the testing series of transformer today we are here with a video on one of the most important testing of transformer, STABILITY Test of transformer. We hope you can learn from this video about the test and clear all your concepts. Thank you for watching!! important links 1.current transformer working and wiring connection. th-cam.com/video/ZwHEOb0sGE8/w-d-xo.html - hindi th-cam.com/video/dZ32zqoUW1M/w-d-xo.html - English 2.current transformer wiring from CT to CT MK box th-cam.com/video/11avOP2ANiE/w-d-xo.html - hindi th-cam.com/video/SL9_hgfGPs0/w-d-xo.html - English 3.current transformer wiring from CT MK Box to Control panel th-cam.com/video/eCBqVp5XYJM/w-d-xo.html -hindi th-cam.com/video/yXturdZ3FFQ/w-d-xo.html -English 4.Differential protection in single phase transformer. th-cam.com/video/Q2sKobYEe-U/w-d-xo.html - Hindi th-cam.com/video/D5squs7IFjc/w-d-xo.html - English 5.Differential relay in three phase transformer. th-cam.com/video/lCn8kY-XG90/w-d-xo.html - hindi th-cam.com/video/tIjgvKsPBNo/w-d-xo.html - English
Thanks a lot sir. Your presentation skills and teaching skills are awesome. please make informative videos like this in future for AC circuits and switchyard equipments testings and working
Good sir ji very useful information Sir if we connect LV 415 volt supply to SF 6 breaker then breaker working also test And we also operation it from C and R panel
Sir, 1.Why Battery Bank 1.2V Volt Cell Use . (1)Sir Humko Industrial me 110V DC Control Supply ki Requirement Hoti hay to Hum 1.2 Volt ka Cell Use karke Pura Battery Bank banate hai. Uske Jaga hum 12 Volt ki battery ko Series me Use karke bhi 110 Volt kar sakte hai to 1.2 Volt ka Cell ka Setup Kayu karte hai. (2) Battery ka AH Series aur parallel me kese calculation karte Hai. Series me aur parallel me Same Backup Dega.
Series connection hone pe Ah har ek cell k sath same ata hai, sirf voltage aur internal resistance barta jata hai. Parallel me Ah barta hai aur load current capacity bar jata hai, internal resistance ghaat jata hai, aur voltage same rehta hai agar same no of cells series me lage ho. Powerbank open karne se usko dekhne se samajh jaoge parallel connection se kaise power bank bante hai.
Jab secondary short kar k test kar rhe h toh primary mei voltage adjustment k liye koi device use nhe Kiya h apne. Kyuki jab secondary short hogi toh bare minimum voltage par bhe high current flow ho jiega toh hum rated voltage transformer ko nhe de sakte na ?
Aapne lv earth karke current different hua a to relay ka action bataya nahi .relay tripping nahi bataya .polarity apposit hobe ki koi baat nahi batai .
Hello friends,
In the testing series of transformer today we are here with a video on one of the most important testing of transformer, STABILITY Test of transformer.
We hope you can learn from this video about the test and clear all your concepts.
Thank you for watching!!
important links
1.current transformer working and wiring connection.
th-cam.com/video/ZwHEOb0sGE8/w-d-xo.html - hindi
th-cam.com/video/dZ32zqoUW1M/w-d-xo.html - English
2.current transformer wiring from CT to CT MK box
th-cam.com/video/11avOP2ANiE/w-d-xo.html - hindi
th-cam.com/video/SL9_hgfGPs0/w-d-xo.html - English
3.current transformer wiring from CT MK Box to Control panel
th-cam.com/video/eCBqVp5XYJM/w-d-xo.html -hindi
th-cam.com/video/yXturdZ3FFQ/w-d-xo.html -English
4.Differential protection in single phase transformer.
th-cam.com/video/Q2sKobYEe-U/w-d-xo.html - Hindi
th-cam.com/video/D5squs7IFjc/w-d-xo.html - English
5.Differential relay in three phase transformer.
th-cam.com/video/lCn8kY-XG90/w-d-xo.html - hindi
th-cam.com/video/tIjgvKsPBNo/w-d-xo.html - English
Too much hard work you have done to make everything easy and understandable,
Thanks a lot Sir.
One plateform for Substation information.
Aapke vedio se bahut jankari milti hai
Thanks for watching 👍..we are glad to know that we have helped you to learn concepts..keep watching.
Kindly make a video Primary injection and secondary injection testing of relays and circuit breakers
Sir please make video about busbar stability and testing process
nicely explained. thoda bay ke baarey mein bataye please
Excellent work sir...please mention the supply voltage value in 66kv side during the test..
440v 3-ph power supply....
RYB phase me 415voltage dete hai to use short link se short karenge toh flash nahi hoga?
iam watching ur vedios the information is too helpfull to us sir
Thanks for watching 👍..we are glad to know that we have helped you to learn concepts..keep watching.
Good morning sir,We are ver much thankful to you sir for sharing us a lot of information which is very useful in our work places.🙏
Thanks for watching 👍..we are glad to know that we have helped you to learn concepts..keep watching.
Sir very thanks for this type of informative videos pls make videos for synchrones genrator testing.
Thanks a lot sir.
Your presentation skills and teaching skills are awesome. please make informative videos like this in future for AC circuits and switchyard equipments testings and working
sure...
Thanks for watching 👍..we are glad to know that we have helped you to learn concepts..keep watching.
Please make a video on complete panel testing
Sir please directional over current and directional ef ke liye ek video banaiye bhaut confusing topic hai
Very nice explain and very informative video's keep it up.
Thank you very much
Thanks for watching 👍..we are glad to know that we have helped you to learn concepts..keep watching.
Super sir ji 🙏
Sir, please do a video explaining the commissioning tests to be performed before taking Capacitor bank into service
Very good. Thanks 🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏
Good sir ji very useful information
Sir if we connect LV 415 volt supply to SF 6 breaker then breaker working also test
And we also operation it from C and R panel
yes sir, you can do the same...
technicaly we need to give minimum requirements of the test...
thank you for your veluable comments...
Differential relay ka practical wiring pe video bnaye
very gd information
keep of the good work
Commissioning and relay and scarda testing ke liye mujhhe aapka paid class chahiye
Plz sir rply soon
Awesome video sir. thanks
Sir tan delta test pe bhi ek video banaye...ek bhi video sir nahi bana hai ....usme bahut confuse ho raha hai🙏🙏
Can you explain calculations. How convert. 9a. To. 63 and. 55a to 300. Pls. Make a video on this concept
Tq
Good information 👍
Please make video on PLCC
Sir can you make video on pole discrepancy relay, with 220 kV breaker pannel wirring
Respected Sir,
Please explain Generator stability testing.
Very well information
Sir kindly make video on REFR stability
Sir please explain about auxiliary switch wiring in detail and also how to use spare contacts with "U" series nomenclature.
It worked for me.
Good video sir ji
Sir,when you supplied a three phase supply to mccb , please mention how much voltage you applied? Is it 415V or else?
415V
Informative
sir jab short karenge to protectin oprate ho jayega
Sir,
1.Why Battery Bank 1.2V Volt Cell Use .
(1)Sir Humko Industrial me 110V DC Control Supply ki Requirement Hoti hay to Hum 1.2 Volt ka Cell Use karke Pura Battery Bank banate hai. Uske Jaga hum 12 Volt ki battery ko Series me Use karke bhi 110 Volt kar sakte hai to 1.2 Volt ka Cell ka Setup Kayu karte hai.
(2) Battery ka AH Series aur parallel me kese calculation karte Hai. Series me aur parallel me Same Backup Dega.
For better longivity of battery pack, i think we use individual cell with nominal voltage in series connection.
Series connection hone pe Ah har ek cell k sath same ata hai, sirf voltage aur internal resistance barta jata hai.
Parallel me Ah barta hai aur load current capacity bar jata hai, internal resistance ghaat jata hai, aur voltage same rehta hai agar same no of cells series me lage ho. Powerbank open karne se usko dekhne se samajh jaoge parallel connection se kaise power bank bante hai.
sir why we do transformer low voltage testings and what purpose,
plz explain the reason
Please explain lbb protection for 11kv bus system
Thanks Sir.. Pl make a wats app group also.
Sir CT ke bad PT bhi ayega..
Sir please make a video 132/33kv ka
Thanks 🙏🙏🙏
Helpful...
Jab secondary short kar k test kar rhe h toh primary mei voltage adjustment k liye koi device use nhe Kiya h apne. Kyuki jab secondary short hogi toh bare minimum voltage par bhe high current flow ho jiega toh hum rated voltage transformer ko nhe de sakte na ?
this is the LV test of transformer,you need to give only 440v on HV side. not rated voltage.
Sir Make MM30 Relay Make setting parameters calculation
❤️❤️❤️
Sir ct ko kitna voltage denge....
440v 3-ph.. supply
Testing k vedio aap banao
11kv panal. Nu. Wiring
Stability test of NCT...
Transformer high voltage test name ?
Aapne lv earth karke current different hua a to relay ka action bataya nahi .relay tripping nahi bataya .polarity apposit hobe ki koi baat nahi batai .
Not replied
very informative video
Thanks for watching 👍
❤️❤️❤️