Sir your videos very helpful for all civil engineers but not only for civil engineer also for those who are involved in construction works..... Thank you sooo much sir .....
Very Good you have explained very nicely but many peoples are asking about the difference between T and concrete starter better you should explain it briefly. Wish you all the best
Sir, it is really a helpful video. Pls tell how many days curing is to be done after we have prepared the PCC and how many days of curing is needed for column footing and after the column is casted, do we have to fill the hole with big stones & sand or anything else ? Regards,
You need to make sure that the installed forms are properly fit to the kicker if not there will be feather edge. We don't use this because of a few reasons. Another reason is that there will be no monolithic column (if you can imagine).
Sir.. Few days ago you uploaded a video on Civil engineering interview questions. But now its not showing on your channel. Either it got deleted or may be its removed. Please sir, provide me the link in my reply section. Please sir. 🙏🙏
Sir your videos very helpful for all civil engineers but not only for civil engineer also for those who are involved in construction works..... Thank you sooo much sir .....
Patiala punjav sa hu sir ap sa bhout idea milta ha🙏🙏
Your channel is the best.
Very Good you have explained very nicely but many peoples are asking about the difference between T and concrete starter better you should explain it briefly. Wish you all the best
Wow good work love it so much ...
Very informative..kindly make video on Billing
Thanks for this video..
Please make a video on how to calculate quantity of steel on roof beam and slab... please make this video
ofcourse umer soon keep watching please share our video
@@civilsitevisit Thanks sir
Asslamu alikum bhai can you help bhai plz 9667801148 this is cantact no plz
Very useful video sir.. thank you so much
Very helpful video sir
Thanks sir
Sir, it is really a helpful video. Pls tell how many days curing is to be done after we have prepared the PCC and how many days of curing is needed for column footing and after the column is casted, do we have to fill the hole with big stones & sand or anything else ? Regards,
Sir,
At many sites I saw that, they used reinforcement T as a starter what is differences between reinforcement T and concrete starter..
In rectangle there are two diagonals, Ek hi diagnal check kr na hai?
Sir thanks for this video...
keep watching brother
Sir column shuttering ke liye concrete ka kya ratio hona chahiye
Brother,pls explain what is the role and responsibilities of civil permit to work foreman in oil and gas
Column starter ke liye mortar use karte hai kya concrete use karte hai?
Hlo sir, good work....pls tell k kitna variation allowable rhega ..jese 749mm perfect hona chahiye ya thoda upr niche chlega? agr chlega to kitna?
Sir ek bar me kitne height tk ki casting ki jati hai column me
Sir BBS pe ek video bana do
vijay 10-15 videos hai uspe playlist dekho
Sir Keya aap curve setting ke upar video Bana sakte ho?
Slab and beam volume calculate ka video banaiye sir site drawing ke anusar
You need to make sure that the installed forms are properly fit to the kicker if not there will be feather edge. We don't use this because of a few reasons. Another reason is that there will be no monolithic column (if you can imagine).
Sir right angel starter aur kinare k steel k beech cover kuch rahega ya nahi
kuch smja ji kya pusch rahe ho
Sir total station samjh me nahi aa raha hi...
Isme kinte mm ka rod or stirrup LGA huaa hai sir ji
Sir.. Geotechnical Soii report ko kaise samjha jata hai is par koi Video bnaye plzzzz
I think maximum height of starter should be 50mm.
Minimum should be 75mm
Sir, starter krane ke baad kitane tim ke baad form work krana start krana hota hai?
After casting starter how to check column formwork is in right angle on upper side also in if we have float column
Tq sir
5:50 khichekane chance rahte h, no brother achhe se foam work kroge. nhi move hoga
At my site Surveyor provide the reference points by total station for starter and footing.
How to read Layout drawing?
Please make video
Nice
Good
Thanks brother keep watching
Dada ratio kitna diya please bolega
Thanks sir
Column size Kiya hai
We can see column lapping zone is incorrect ( tension zone m lapping provide h but provide krna tha compression zone m )
But sir starter me rightangle kese check krne ka because Bars bichme aajate he so properly nahi check ho pata..☹️
Yes.. I also want to ask this sir please tell us
starter bethene se phele check kar lo
Bhai site pr chhoti gunia hoti h use use kro otherwise both outer lines ko aage badhakar jha dono lines crossect kregi wha se check krlo
👌👌👌
Ye 7.5 mm kaha se measure karna hai?
Bro ye to batao k starter me Concrete grade kya hoga??
jo column liye houga M30 dalo
Sir mere 600x1200 guniya nikal ka hai
Rocker or kicker
Sir I have a big confusion in starter height 50mm and 75mm who is right
50 mm
Can anyone explained why they lapped in tension zone in this video? This is not right
Do not use starter-Control form from outside
1 meter 2 mtr 3 mtr k sath
Bich vale colum add krne padate hai🤦
Sir what is the approx cost of DMC pilling excluding material
Column laps are in no lap zone.
What are you teaching
Sir.. Few days ago you uploaded a video on Civil engineering interview questions. But now its not showing on your channel. Either it got deleted or may be its removed. Please sir, provide me the link in my reply section. Please sir. 🙏🙏
which one check playlist for it ....interview Playlist
civilsitevisit.com here
Tamil video please
Stater banane ki kya jarurat hai only time pass, without starer more than 20 building complete.
Copy paste😌😌
Great knowledge😊
Thank you so much for this video....
Thanks sir