MK LOGIC RAPID FIX - Double socket with SCREWLESS terminals.

แชร์
ฝัง
  • เผยแพร่เมื่อ 12 มิ.ย. 2024
  • We posed the question last year, when will UK sockets have Wago style screwless terminals?
    Here we have the worlds first 13A Double Socket which complies with BS1363. The MK Logic Plus Rapid Fix is the first double socket to incorporate screwless terminals.
    This game-changing product reduces installation time and ensures a more reliable electrical connection.
    Developed in partnership with Wago, installing the MK Rapid fix is just like using the popular Wago 221 terminals.
    Are these sockets really Rapid fit? - we put them head to head with the traditional MK screw double socket.
    📺 👉 • MK RAPID FIX SOCKET- V...
    == AD ==========================
    ** Available now from SCREWFIX **
    hub.efixx.co.uk/mk-rapid-fix
    ==============================
    ================================
    00:00 MK Logic Plus Rapid Fix
    00:18 The first UK 13A socket with screwless terminals
    00:52 BS1363 Screwless terminals & socket outlet
    01:12 MK first to market
    01:38 Conductor capacities
    02:20 Logic plus features - 3 Pin safety shutter
    03:57 Mk Rapid Fix socket - Wago style terminals
    04:40 Screwless terminal conductor types
    07:19 Back box size requirements
    08:18 How to fit a Rapid Fix 13A double socket
    12:30 More reliable and faster electrical installations
    =================================
    📍SUBSCRIBE TO THE CHANNEL eFIXX helps electricians, electrical contractors, building services engineers, and electrical apprentices. Watching our videos, you'll discover new products, explore new applications and find answers to your technical questions. So if you've been on the tools for years or just starting your electrical journey, we'll help you stay up to date with the latest regulations and developments in the electrical industry.
    hub.efixx.co.uk/youtube-subscr...
    ================================
    📺 NEW TO THE EFIXX CHANNEL Watch our essential videos playlist hub.efixx.co.uk/essentials​
    📺 CATCH UP ON THE LATEST VIDEOS
    hub.efixx.co.uk/latest​
    📺 ELECTRICIANS' TOOL REVIEW
    hub.efixx.co.uk/tools​
    ================================
    🔴 eFIXX LIVE Join us for our youtube live stream twice a month - features product sneak peeks, challenges, giveaways and live electrical banter. NEXT STREAM HERE
    👉hub.efixx.co.uk/next-live-stream​
    Catch up on previous episodes
    👉hub.efixx.co.uk/livestream​
    ================================
    🆕 FREE CPD Learn about new applications, regulations and best practice with our FREE CPD modules. - New modules released every month covering everything from surge protection to lighting hub.efixx.co.uk/CPD​
    ================================
    📝 APPRENTICE HUB If you're an electrical apprentice, retraining as an electrician or looking to refresh your knowledge, then please check out our apprentice hub. It contains thousands of multiple-choice questions to help prepare for electrical installation exams. hub.efixx.co.uk/apprentice​
    ================================
    📩 eFIXX NEWSLETTER Sign up to find out about our live events, competitions and product giveaways.
    www.efixx.co.uk/sign-up​
    ================================
    FOLLOW US on your favourite social networks for behind the scenes action, breaking news and competitions.
    🟠 INSTAGRAM hub.efixx.co.uk/Instagram​
    🔵 LINKEDIN hub.efixx.co.uk/linkedin​
    🟣 FACEBOOK hub.efixx.co.uk/facebook​
    🟡TWITTER hub.efixx.co.uk/twitter​
    ==================================
    ❌ This content on this channel is for electrical professionals.❌ ==================================
    📹 Presented by
    Gary Hayers - Editor eFIXX
    Gordon Routledge CEng MIET - Technology Editor eFIXX ===================================
    #efixx #electricians #wiring
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 467

  • @_Miner
    @_Miner 2 ปีที่แล้ว +31

    Now we just need them to do this with all the different finishes like chrome, flat etc.. and with other things like light switches, isolators, fsu etc..

  • @timahad5165
    @timahad5165 2 ปีที่แล้ว +11

    "I wasn't ready for you doing that!"
    These two should have there own sketch show!🤣

    • @efixx
      @efixx  2 ปีที่แล้ว +1

      😆

  • @johnlloyd3377
    @johnlloyd3377 2 ปีที่แล้ว +12

    Well done MK. Finally a UK socket with Wago style connectors. A transparent connector similar to the Wago 221 connector would have been even better. I have used French sockets with screwdriverless connectors but they were only suitable for solid conductors and once connected the conductor was almost impossible to remove. From this presentation it appears that the MK connector can accept solid, stranded or fine stranded conductors and the conductor can be withdrawn by simply lifting the lever. I cannot wait to try them out.

    • @johnlloyd3377
      @johnlloyd3377 2 ปีที่แล้ว

      @@wagodraper4201 Thanks, that is good to know.

  • @acespark1
    @acespark1 2 ปีที่แล้ว +4

    About time a few makers of commando plugs and sockets have been on this for ages

  • @geraldelwood9660
    @geraldelwood9660 2 ปีที่แล้ว +3

    A welcome step forward. Now we just need them to take that terminal block and locate it in the back box, (with a suitable flexi fly led to the socket.) So at first fix we can complete and test the ring before the kitchen fitters come along and screw through our rings. And socket faces can be unscrewed for EICR's, with much less risk of causing a broken conductor as we push back the face plate.

  • @Leodis.Leather
    @Leodis.Leather 2 ปีที่แล้ว +8

    These look like a great idea to me. I'm not a professional electrician but I think for people doing bits themselves at home (where appropriate, I'm not a numpty!) this should be a lot safer as well since they remove the chance of making a bad termination that might come loose when the socket is fixed back. Price wise a single one of these is currently £6 on Screwfix and the standard one is £3.77 so they cost ~60% more which is a hefty increase though I think it's worth it for the convenience and safety factor.

  • @alanwilliams4835
    @alanwilliams4835 2 ปีที่แล้ว +13

    All our company use is them mk logic range and we just love this . The golden rule is never ever fit a 25 mm box for a socket . Why you may ask ? If the client asks you for a flat plate socket to be fitted it will not fit in a 25mm box you will need a 35 mm box .. more room for the wiring too. Come on guys it takes 5 min more to cut a 35 mm box in ..

    • @darylsavage119
      @darylsavage119 2 ปีที่แล้ว +6

      Takes no extra time to chase in when a tracking company are being paid to do it instead.
      35mm for spurs, switches and sockets, 47mm for cooker and shower boxes

    • @alanwilliams4835
      @alanwilliams4835 2 ปีที่แล้ว +3

      @@darylsavage119 Exactly couldn’t agree more

    • @efixx
      @efixx  2 ปีที่แล้ว +2

      👍

  • @davidmack610
    @davidmack610 2 ปีที่แล้ว +14

    Definitely the way forward. A slight improvement would be to provide 4 CPC connections, to allow connection of a spur and a back box fly lead too...

  • @mikeselectricstuff
    @mikeselectricstuff 2 ปีที่แล้ว +75

    I'd be interested to see thermal images of these compared to screw terminals when passing 32A from wire to wire

    • @sparkey1958
      @sparkey1958 2 ปีที่แล้ว +6

      seen so many of 16 A and 32A sockets [trailing type] where the push in connections have got so hot and burned the insulation back.....wait a few years and the fires will start on fully loaded 32A radial circuits with plastic fast fix boxes.

    • @johnburns4017
      @johnburns4017 2 ปีที่แล้ว +6

      @@sparkey1958
      What push in wire sockets do you refer to?

    • @michaelboyes4948
      @michaelboyes4948 2 ปีที่แล้ว +1

      @@johnburns4017 think he's on about commando sockets and I fully agree with him seen to many burnt out maintenance free commando sockets

    • @sparkey1958
      @sparkey1958 2 ปีที่แล้ว

      @@johnburns4017 commando sockets...

    • @technic550
      @technic550 2 ปีที่แล้ว +9

      @@sparkey1958 I've seen far more issues with screwed terminals tbh. Whatever the terminal type of a trailing lead they should always be regularly inspected due to the nature of its use. That and bad practice I believe is the main reason for most issues.
      I personally like the idea of the lever connections, they don't damage the conductors like screw terminals.

  • @thomasbonse
    @thomasbonse 2 ปีที่แล้ว +9

    I think there should be one more lever position, specifically for the the CPC. This would allow for a conductor to connect to a metal box, even when you have both a ring and radial connecting in the same box, without the need for an additional connector for the CPCs.

    • @johnburns4017
      @johnburns4017 2 ปีที่แล้ว

      Use a metal backbox with a solid lug, then an earth tail to the box is not needed. Why do something you do not need to do!

  • @guffermeister
    @guffermeister 2 ปีที่แล้ว +23

    Should really have 4 terminals for the earths. This would allow for the two (eugh!) ring legs, a spur and then also the obligatory flylead for the metal back box

    • @darrentremain2670
      @darrentremain2670 2 ปีที่แล้ว +3

      Glad you have also spotted this issue. 👍🏻

    • @mattylad8035
      @mattylad8035 2 ปีที่แล้ว

      4 terminals? like on a standard socket where you have 4 terminals also? think not.
      On many sockets you only have 1 terminal and stuffing 4 leads in it is extremely hard.

    • @12000gp
      @12000gp 2 ปีที่แล้ว +2

      @@mattylad8035 is it that hard?

    • @guffermeister
      @guffermeister 2 ปีที่แล้ว +1

      Aye. As its a screwless connector its one conductor per connection terminal. This is to ensure a good connection due to the way the connectors work. And 4 conductors is an issue - most outlets say max of 3 for 2.5mm cable, although the CPC is 1.5mm so a little more space available.

    • @ExtrakzCrunch
      @ExtrakzCrunch 2 ปีที่แล้ว +2

      Nothing obligatory about fly leading a backbox with a fixed lug

  • @TheAdamEdward
    @TheAdamEdward 2 ปีที่แล้ว +2

    Brilliant design! Can’t wait to test these out 👍🏻

  • @harryhoudini9826
    @harryhoudini9826 2 ปีที่แล้ว +2

    I wasn't ready for you doing that!...savage!.....

  • @DIYJourney1
    @DIYJourney1 2 ปีที่แล้ว +1

    Looking forward to watching this and seeing the thoughts of these 👍🏻

  • @FFT_Electrical
    @FFT_Electrical 2 ปีที่แล้ว +7

    Would be good to see a comparison of an average sized circuits continuity between these and standard screw terminal sockets

  • @martinw245
    @martinw245 2 ปีที่แล้ว +3

    As soon as I came across Wago connectors this occured to me. Great stuff.

    • @wagodraper4201
      @wagodraper4201 2 ปีที่แล้ว +3

      And these use the WAGO springs inside so you can be sure of a quality connection :-)

    • @rodgerq
      @rodgerq 2 ปีที่แล้ว

      It amazes me how long it's taken someone to bring these to market.

    • @martinw245
      @martinw245 2 ปีที่แล้ว +2

      @@rodgerq
      Hopefully MK will extend the range to light switches and FCU's.

  • @spanishmarc
    @spanishmarc 2 ปีที่แล้ว +3

    In Spain where I work, my preferred sockets and switches (Simon 27 Play) are all push fit. It's definitely the way to go.

  • @1bigsyd
    @1bigsyd 2 ปีที่แล้ว +5

    About bloody time

  • @Mark1024MAK
    @Mark1024MAK 2 ปีที่แล้ว +3

    In regards to screw terminals damaging the copper conductors, I don’t understand why premium electrical switches, sockets, etc don’t use rising clamp terminals. Lots of industrial equipment uses rising clamp terminals, as do some MCBs.

  • @alanjones3873
    @alanjones3873 2 ปีที่แล้ว +1

    Just what I needed, most modern outlets are difficult to use with 3 old stranded cables never mind mixing with solid . I had to extend a ring for socket on wall just behind existing single outlet. Old stranded including an existing spur. Fitted this double outlet in standard backbox. Broke in to ring with two 2 cables through wall. Fitted it all in including 3 Wagos. No lifting floor for a junction box!!

  • @jonty2020
    @jonty2020 2 ปีที่แล้ว +5

    Great for a spur off a 4mm radial circuit which is quite hard to achieve with the traditional screw connector.

  • @GrahamDIY
    @GrahamDIY 2 ปีที่แล้ว +5

    Thank GOD these are FINALLY here !!! I will be only buying these kind of faceplates from now on.
    Why has it taken so long ???
    Great video, as ever, guys 🥰

    • @efixx
      @efixx  2 ปีที่แล้ว +1

      Standards needed to change first, then navigating the various patents!

    • @GrahamDIY
      @GrahamDIY 2 ปีที่แล้ว +1

      @@efixx yep. The wheels turn slowly....

    • @cuebj
      @cuebj 2 ปีที่แล้ว +2

      @@barnabybot Considerably less than the minutes of labour doing good job with screw down sockets. Maybe not cheaper than sloppy use of screw down. As DiYer, I've had to reset all my screw down sockets as jobs done by several registered and recommended professionals came loose, earth sleeving had slipped into the screw down, or too tight so cable broke, etc.

    • @jordankidd8789
      @jordankidd8789 2 ปีที่แล้ว

      @@barnabybot £30 for 5 in Screwfix

    • @GrahamDIY
      @GrahamDIY 2 ปีที่แล้ว

      Just bought one today from SF. Had a play with it. Looks really well made.
      I like it!!!

  • @craigemmott4976
    @craigemmott4976 2 ปีที่แล้ว +1

    Was working at Kwik-fit Skipton today and had a bit of a nosey at e-Fixx HQ with the dog once I'd finished there. I should have been cheeky and popped in for a cuppa, was parched. Sadly, work had to come first.
    Still loving the videos chaps!

    • @efixx
      @efixx  2 ปีที่แล้ว

      You should have popped in - kettle always primed!

  • @andrewbutcher3391
    @andrewbutcher3391 ปีที่แล้ว

    Really helpful this…thanks

  • @Cablesmith
    @Cablesmith 2 ปีที่แล้ว +5

    Just used one of these myself today, quite like it

    • @DstandsforDoomed
      @DstandsforDoomed 2 ปีที่แล้ว

      Standard 25mm back box sean? How’d it screw back if so?

    • @Cablesmith
      @Cablesmith 2 ปีที่แล้ว

      @@DstandsforDoomed very easily, but the cable entry was my friend on that one, as well as only 1 cable 😀
      There’s a video, have a look 😁

  • @alexandercarney1305
    @alexandercarney1305 ปีที่แล้ว

    4:07 That’s all I needed to know 😅. Thanks guys ✌️

  • @jonathanrose456
    @jonathanrose456 2 ปีที่แล้ว

    35mm are my go to for back box, but nice to know for existing.
    Be great when more manufacturers & brass/chrome versions come out.

  • @camerongray1515
    @camerongray1515 2 ปีที่แล้ว +4

    Been wanting something like this for so long, hopefully they extend it across more products such as FCUs and switches, although the design would probably need to be changed to make the terminals small enough to fit on a single gang product. If they're keeping the screwless terminals exclusively to the double sockets, it would at least be good to see more widespread adoption of cage clamps like on the Crabtree instinct range, at least then you don't have the issue with damaging conductors by overtightening. Makes for a tough decision when deciding on a range to go for - Logic Plus for screwless sockets but regular screws on everything else, or Crabtree Instinct for cage clamps on everything but no screwless option.

    • @efixx
      @efixx  2 ปีที่แล้ว +1

      The range will be expanded. - stay tuned

  • @tennicktenstyl
    @tennicktenstyl 11 หลายเดือนก่อน

    the safety shutter makes the wire-to-socket connection more sturdy when it closes and pinches the wires tight. highly recommend

  • @user-wy4oy6di4x
    @user-wy4oy6di4x 2 ปีที่แล้ว +13

    I use wagos as a lift engineer, they should be standard in all industries.

  • @almondchristopher
    @almondchristopher 2 ปีที่แล้ว +1

    These types of quick fix/release have been on the back of European sockets for years. I am surprised to see they have only now been introduced in the UK.

  • @mars6394
    @mars6394 2 ปีที่แล้ว +7

    Have they final made what you was saying all along

  • @zjzozn
    @zjzozn 2 ปีที่แล้ว +1

    Well done chaps

  • @bobrose7900
    @bobrose7900 2 ปีที่แล้ว

    Can't believe this hasn't been done before. Spring loaded connectors are infinitely more reliable... but the down side will be cost on the contracting front, unless specified by a forward thinking client. Well done MK..

  • @brianhewitt8618
    @brianhewitt8618 2 ปีที่แล้ว +1

    exellent, inovation moving forward

  • @giorgos424
    @giorgos424 2 ปีที่แล้ว

    Hi! Could you please share the video regarding conductor classification? Thank you for your content!!

  • @iknowmyfootball3901
    @iknowmyfootball3901 2 ปีที่แล้ว +5

    Angle of entry is good rather than going directly into the back that lower entry point allows it to fit comfartbaly in a 25 mm backbox

  • @asadbabilbabil7791
    @asadbabilbabil7791 2 ปีที่แล้ว +1

    Very good

  • @markyd2633
    @markyd2633 2 ปีที่แล้ว +1

    Great vid boys.......

    • @efixx
      @efixx  2 ปีที่แล้ว

      Thanks

  • @ratsalive
    @ratsalive 2 ปีที่แล้ว +1

    Has anyone asked, what do you do with a spur and a cpc fly lead to the back box. I assume there's a metal face version. Maybe that's double insulated? You'd need four cpc terminals or do you squeeze a wago in the back or can you put two conductors in one lever?

  • @roblewis730
    @roblewis730 2 ปีที่แล้ว +2

    I think price is a big factor with these. Clients generally won't care what's behind a socket and will only see the socket front on the wall as such, so £6.50odd a socket could on say a rewire send the price upwards.
    However it is the future, and when more brands do the same across the range of accessories I think it'll become more affordable.
    Just need to get Wago Consumer Units now!

    • @jablot5054
      @jablot5054 ปีที่แล้ว +1

      This could be off set by reduced time fitting, especially if using Wago

  • @PatonCavaney
    @PatonCavaney 2 ปีที่แล้ว +3

    Now for all Isolators (FCUs, Lights)and networking to have this

  • @dsesuk
    @dsesuk 2 ปีที่แล้ว +3

    Tomorrow's technology.... TODAY! I'm liking it.

    • @efixx
      @efixx  2 ปีที่แล้ว

      Cheers David … it’s like Tomorrow’s World !

  • @helmanfrow
    @helmanfrow 2 ปีที่แล้ว

    13:35 Yes, this, and I can't believe nobody in North America has a similar product yet.

  • @arfanjhangir8465
    @arfanjhangir8465 2 ปีที่แล้ว

    Great idea. Any link to the cable stripper please?

  • @johnallen8808
    @johnallen8808 2 ปีที่แล้ว +16

    How long before we have posidrive 3.5 fixing screws rather than slotted screws?

    • @TimmyBoja
      @TimmyBoja 2 ปีที่แล้ว +1

      I’ve started to appreciate the slotted-pozi. Makes me feel important 😆

    • @adrianking6309
      @adrianking6309 2 ปีที่แล้ว +3

      Torx would be even better

    • @daniellittle7846
      @daniellittle7846 2 ปีที่แล้ว

      @@adrianking6309 yeah it would help prevent the cowboys but torx is becomming really quite common nowadays
      Its really difficult to keep people from getting their hands on screwdrivers

    • @poulhenne
      @poulhenne ปีที่แล้ว

      @@adrianking6309 : Watching from Denmark where everything is Torx10, seeing the oldfashioned fixing screws really gave me a nostalgic feeling. We changed to pz in 1985 away from the flat blade. And actually at that time we also went away from screws on terminals of wall sockets.

  • @oliverriall
    @oliverriall 2 ปีที่แล้ว +1

    Awesome, so will this be maintenance free. Will the EICR be forever changed!?

  • @DickieBird888
    @DickieBird888 ปีที่แล้ว

    These sockets are the future along with every other device using this method eventually...

  • @jeffmoye
    @jeffmoye 2 ปีที่แล้ว +11

    Why not 4 cpc connectors? Would allow for a spur and back-box strap. Or could you put 2 1.5’s in a single terminal?

    • @buckshee
      @buckshee 2 ปีที่แล้ว +3

      You’d put the cpc into the back box first then onto the socket. No need for four earth terminals at the socket.

    • @josephkent9475
      @josephkent9475 2 ปีที่แล้ว

      It’s a plastic socket no need for the fly lead tho

  • @TeamSimpsonRacing
    @TeamSimpsonRacing 2 ปีที่แล้ว

    Great video guys. This is the future but also the future where customers will start doing more and more themselves 😪

    • @efixx
      @efixx  2 ปีที่แล้ว +1

      The 🧞‍♀️ left the bottle on that one long ago - just look at how many you tube electricians title their videos “how to” …. Change a consumer unit etc

  • @gmeadowcroft84
    @gmeadowcroft84 2 ปีที่แล้ว +2

    I’m really impressed with them, quick question for you guys though.
    On stranded cable how do the terminals hold up with a feral in the terminals? I’m guessing they should be fine and and there is probably no need to feral them in these types types of connectors

    • @DstandsforDoomed
      @DstandsforDoomed 2 ปีที่แล้ว +1

      Stripping length is 10mm, normally get 10mm on a bootlace ferrule, so in reality it should marry up to the shoulder of the ferrule. Gonna have to try this myself…

  • @iknowmyfootball3901
    @iknowmyfootball3901 2 ปีที่แล้ว

    What a time to be alive honestly u could blast 100 sockets 2nd fix nip up the faceplates with the Speed E .
    What's your thoughts on this type of connection for shower pull cords, that pesky neutral is usually cooked

  • @johnbrown-so3vz
    @johnbrown-so3vz 2 ปีที่แล้ว

    About bloody time. How many times do I see burnt out terminals?

  • @danf6491
    @danf6491 ปีที่แล้ว +1

    Still waiting for the wago fuseboard. One place that could definitely do with the technology is shower isolators . Might save a few neutrals. Wonder if crabtree will update there already amazing isolator

  • @brucerobson8767
    @brucerobson8767 2 ปีที่แล้ว +2

    I’m surprised that so many responders think they need a 4th terminal for a back box ‘fly lead’. With these sockets the faceplate fixing screws give a perfectly adequate earth connection to the back box.

    • @thomasbonse
      @thomasbonse 2 ปีที่แล้ว +1

      There's generally adequate, then there's guaranteed; and they're mutually exclusive. With the 4th terminal for CPC, the box remains earthed even if something happens to the screws, or when the cover is removed for testing.

    • @johnburns4017
      @johnburns4017 2 ปีที่แล้ว

      Yes Bruce. No need for an earth fly lead if at least one lug is solid.
      Also the adjustable lug also gives an earth. Pretty well guaranteed to earth the socket to the metal box behind.

  • @barrie5852
    @barrie5852 2 ปีที่แล้ว +2

    This has be the way forward, putting 2 sometimes 3 (for a fused spur) conductors into a single screw fixed connector has always been a flaw of the ring main method because of not nowing if both conductors are evenly secured.

  • @Chris-hy6jy
    @Chris-hy6jy 2 ปีที่แล้ว +3

    Finally!! And now one for the cable manufacturers... T&E with insulation on the earth conductor! No need for bloody earth sleeve anymore!!

    • @100tinsoldiers
      @100tinsoldiers 2 ปีที่แล้ว +2

      They used to do it in the 70s, Crabtree also had screwless terminals in the 80s

    • @efixx
      @efixx  2 ปีที่แล้ว +6

      Irish ☘️ Twin and earth has all three cores insulated.

    • @Chris-hy6jy
      @Chris-hy6jy 2 ปีที่แล้ว +2

      @@efixx ah didn't know that. I guess the only downside is the cable's overall thickness would be slightly thicker. Also the price would be a bit higher but I'm sure most sparks would gladly pay a small premium to not have to use earth sleeving at every single termination.

    • @efixx
      @efixx  2 ปีที่แล้ว +3

      Other issue is the earth conductor in the Irish T&E is equal (2.5mm ) to the others - more copper, more £££ - www.wesco.ie/news/new-twin--earth-wiring-rules.html

    • @Chris-hy6jy
      @Chris-hy6jy 2 ปีที่แล้ว +1

      @@efixx is this reg likely to come in for the UK? If not, we could still use an insulated 1.5mm version.

  • @BLOCKsignallingUK
    @BLOCKsignallingUK 2 ปีที่แล้ว

    Can you wire the CPC via the terminal in the backbox (ie two ends in that terminal) ?

  • @johnchown3539
    @johnchown3539 2 ปีที่แล้ว

    What’s the cable strippers called, and where can I purchase them, great videos always look forward too them,

  • @vwes
    @vwes 2 ปีที่แล้ว

    Cool, at last :-) Looks like its only available in white and for indoor use. Hopefully the range will expand to outdoor sockets and other finishes

    • @cuebj
      @cuebj 2 ปีที่แล้ว

      That's all I need for now at home. Tempted to replace all my sockets. Would be nice to have grid switches like this

  • @davidpenn2518
    @davidpenn2518 2 ปีที่แล้ว

    Nice to see you placed the the line & neutral in the wrong socket holes....

  • @islandhopperstuart
    @islandhopperstuart 2 ปีที่แล้ว

    Sorry Gaz, I'm not overly convinced by your trial where the cables came up into the back box. Looking closely, whilst in contact with the 'plasteboard' at the top, the socket appeared to stand-off a little at the bottom when tight. I can't help thinking that the double thickness of conductor was being trapped between the levers and the box. Please can you take a closer look? Specifically, how does the minimum gap from levers to back box compared with 2x, or 3x diameter of, say 4.0mm^2 conductors over the insulation?

  • @owent2032
    @owent2032 2 ปีที่แล้ว

    Well it's about time someone listened to the consumer

  • @tonystewart6592
    @tonystewart6592 2 ปีที่แล้ว

    About time too...

  • @jacksonroad9263
    @jacksonroad9263 2 ปีที่แล้ว

    nice video like the close up view.
    can we put two 1.5mm wires into one hole?

    • @efixx
      @efixx  2 ปีที่แล้ว +1

      No one cable per hole 🕳

  • @dominicdodd9759
    @dominicdodd9759 2 ปีที่แล้ว +5

    I'd used these - well worth the minutes saved when crawling around you my old knees, fitting dozens. Not sure I'd want to switch to all accessories from MK Logic - may have wait for Scolmore to catch up! As an aside - old MK socket "Made in UK", new MK socket "Made in Malaysia" - shame we don't make anything anymore!

    • @efixx
      @efixx  2 ปีที่แล้ว +1

      85% of MK's products are still made in the UK.

    • @calmeilles
      @calmeilles 2 ปีที่แล้ว

      @@efixx Beautiful kit…
      For budgets that hire interior designers… 13A Twin Switched Socket Outlet *£61.21* exclusive of VAT, naturally. Free delivery on orders over £1,500 which is nice. 😀

    • @jackyleong9553
      @jackyleong9553 2 ปีที่แล้ว +1

      Don’t forget the legendary MEM brand.

    • @Messimagician83
      @Messimagician83 2 ปีที่แล้ว

      You can't believe anything these days with Made in Britain. I use to work for a company that made GAS smart meters that said made in England. All we did was upload the software to the meter but all the build was made in Greece.

  • @chriscollins1704
    @chriscollins1704 2 ปีที่แล้ว +1

    So if you want to earth the back box with a wire and you have a spur on a ring, you'll have to put one of the cpc's in the back box terminal

  • @patrickbishop4099
    @patrickbishop4099 2 ปีที่แล้ว +1

    Looks good on a twin socket, but will they fit on the back of a single? How about a spur or dp switch?

    • @efixx
      @efixx  2 ปีที่แล้ว

      More on the way

  • @garethgordon9141
    @garethgordon9141 2 ปีที่แล้ว +1

    Can you fit 2 cables into one lever if you have 3 cables and back box flying lead? Do the screw housings connect back to the earth circuit in the socket?

    • @johnrhodes3350
      @johnrhodes3350 2 ปีที่แล้ว

      I would think so, and a double/twin ferrule end connector would facilitate that

  • @markrainford1219
    @markrainford1219 2 ปีที่แล้ว +1

    After nearly forty years of 'doubling over' I don't think I could cope.

  • @roberthardy2013
    @roberthardy2013 2 ปีที่แล้ว

    All we need now is a better fixing arrangement to the back box, locating lugs and better screw guidance would be a great thing.
    Crosspoint not flat and with the plain end bit should be standard.
    Just removed loads to decorate a whole house then replaced them - a pain of a job.

  • @tcpnetworks
    @tcpnetworks 2 ปีที่แล้ว

    We have insulation displacement sockets. You can put up to 4mm2 conductors - strip the middle piece of TPS, lay cable in, tighten one screw - no stripping of the primary insulation.

    • @edc1569
      @edc1569 2 ปีที่แล้ว

      Funky, got a link?

  • @shilks8773
    @shilks8773 2 ปีที่แล้ว

    Why no fourth CPC lever / clamp to allow for RFC and Spur and Earthing for metal back box ?

  • @stewartmaclachlan3220
    @stewartmaclachlan3220 2 ปีที่แล้ว +1

    Thomas Nagy has been calling for a product like this for ages.

  • @calvinhale9913
    @calvinhale9913 2 ปีที่แล้ว +2

    I wonder how big the back will be when they introduce USB sockets with this feature ? just a thought ! Great review as always guys :) I think you missed your Dragon's Den moment a couple of years ago, could all be smoking a ciger in your swimming pools by now :))))

    • @efixx
      @efixx  2 ปีที่แล้ว

      😉 we’ve got a few more ideas in the hopper!

    • @HenryLoenwind
      @HenryLoenwind 2 ปีที่แล้ว

      They could use the push-in mechanism that's usually used by German sockets. Those take 2 wires and are smaller than a screw connector. (They are also annoying to use, as you have to push and hold down a plate with quite some force to open them. On the other hand, there's no lever that could snag open.)

  • @claudioscola
    @claudioscola 2 ปีที่แล้ว +2

    Just having a hole for each wire sells it to me

  • @christastic100
    @christastic100 2 ปีที่แล้ว +1

    About time

  • @dalriada842
    @dalriada842 2 ปีที่แล้ว

    Why don't they use slotted-pozi screws for fixing it to the backbox?

  • @uiscebeatha9476
    @uiscebeatha9476 3 หลายเดือนก่อน

    I like MK sockets because of the reinforced faceplate, which stops them from cracking on uneven boxes.

  • @jontownsend8090
    @jontownsend8090 2 ปีที่แล้ว

    I have the same problem, i tend to over tighten the screw terminals, screw less is the new normal.
    Perhaps at some point we will get to see a 100% screw less distribution board.

  • @mrh2602
    @mrh2602 2 ปีที่แล้ว +3

    Guess you would have to go to a 35mm bax box for 4mm cable

  • @Stuart_Johnson_Solutions
    @Stuart_Johnson_Solutions ปีที่แล้ว

    I guess if you need the fourth cpc option then you go to the back box where you can then also connect the spur's cpc in.

  • @izzystuart7798
    @izzystuart7798 ปีที่แล้ว

    I want to see these standard how much easier would it be if RCBOs, light switches, sockets ect... where all screwless

  • @scottjking4
    @scottjking4 2 ปีที่แล้ว

    I see a problem, if you have a loop and a spur off said socket, you will not have enough earth connections to connect the earth to the back box. ??

  • @emlockwood
    @emlockwood ปีที่แล้ว

    I like the fitting but having trouble getting wires in with my installation probably have to strip cable back as supply a little too aggressive but prefer to screw ones as those just kept blowing up in my face

    • @christopherlester4793
      @christopherlester4793 ปีที่แล้ว +1

      My experience too. With 4mm^2 twin+earth I twice had the live pop out of one of the brown terminals and arc over to a (sheathed) CPC on account of the difficulty of these connectors accepting the bend radius needed even in a 35mm back box. Have gone back to screws ... Maybe it would be fine with 2.4mm^2 twin+earth. But I don't trust these with 4.

  • @christopherhume8896
    @christopherhume8896 2 ปีที่แล้ว

    Not used mk for a long time, didn't know you couldn't get the pin covers down using the earth. That would be really annoying when trying to stick my probe tester in. Yes there are times when I just want to stick a probe tester in rather than getting out a big tester and leads.

  • @MyNameWasTecho
    @MyNameWasTecho 2 ปีที่แล้ว

    They look great. Out of curiosity, to they have a testing point that you can probe onto? A socket adapter is my usual go to, but one day it will be missing.

    • @Cablesmith
      @Cablesmith 2 ปีที่แล้ว

      Yep they do 👌🏼

    • @MyNameWasTecho
      @MyNameWasTecho 2 ปีที่แล้ว +1

      @@Cablesmith Good news 👍

  • @1williey
    @1williey 2 ปีที่แล้ว

    What about earthing the box if you have 3 cables in the box.?

  • @looking9175
    @looking9175 2 ปีที่แล้ว +2

    Are there back of socket terminals where can test from without removing the conductors?

    • @efixx
      @efixx  2 ปีที่แล้ว +2

      Yes - small probe points near top of socket

  • @Ad-gn8pl
    @Ad-gn8pl 2 ปีที่แล้ว

    Take my money. And being MK, lots of money

  • @bbwolf9925
    @bbwolf9925 2 ปีที่แล้ว +1

    I love this idea and I've been wondering for a few years when we might see them in the UK. My only problem is that I still can't see them: my favourite wholesaler can't even tell me a price and they've never actually seen one. I have half a dozen holes in a kitchen wall just begging to be filled by these but I guess I'll have to use the plain vanilla screwed terminal type sitting in my toolcase if I want the job finished by Christmas. Or maybe MK can tell me where to look . . .

    • @efixx
      @efixx  2 ปีที่แล้ว

      Available from Screwfix

    • @samjburns07
      @samjburns07 2 ปีที่แล้ว

      @@efixx and CEF, Toolstation, etc!

  • @cal5566
    @cal5566 2 ปีที่แล้ว

    Why is it some mk equipment is UK made and others are not.(Malaysia I think). Is there a way to tell what you're getting. Because I've seen the same components such as metal clad module frames both UK and Chinese made arrive in the same order.

  • @esfae8250
    @esfae8250 2 ปีที่แล้ว

    Looking at a purchase on these and they work out to be double the price. Box of 5 Logic £15 ish - Box of 5 Rapidfix £30. How much is plastic worth :)

  • @raywelshman
    @raywelshman 2 ปีที่แล้ว +1

    Hi all, a great idea at last, however what if you have three T&E conductors and a flying lead to the backbox for the earth, you now have four earth wires but only three earth levers, can you put two earth wires into one lever or would that cause a problem with correct termination? Ok I have just edited my post after trying two earth wires from a 2.5mm T&E cable into a Wago and I gave them a good tug test and they can't easily pulled out..

    • @johnrhodes3350
      @johnrhodes3350 2 ปีที่แล้ว

      Speaking as a non-electrician, could you put a 4mm ferrule on two, or even a twin/double ferrule end connector maybe?

  • @dansheppard2965
    @dansheppard2965 2 ปีที่แล้ว

    Not an electrician here, so sorry if this is a dumb question. What do you do if you with CPCs if you want to use this as the start of a radial spur but you also need a fly-lead because you've got a metal backbox? I imagine it's a bit of a squeeze even with traditional screw terminals. How does it work with maintenance-free connectors with only three holes?

    • @efixx
      @efixx  2 ปีที่แล้ว

      Loop one of the Cpcs via the terminal in the back box.

  • @marcwilliams3921
    @marcwilliams3921 2 ปีที่แล้ว +1

    Bit of topic but what camera are you using Gary ?

    • @efixx
      @efixx  2 ปีที่แล้ว

      We use a range of kit and even our iPhones 📱

  • @exwhyz33
    @exwhyz33 5 หลายเดือนก่อน

    Have MK since produced these sockets including USBC connections?

  • @trishakeaveny8565
    @trishakeaveny8565 2 ปีที่แล้ว

    I would recommend four wago terminals for the cpc's should you require to spur off.

    • @johnburns4017
      @johnburns4017 2 ปีที่แล้ว

      Only needs three Wago terminals if a metal backbox has at least one solid lug.

  • @effervescence5664
    @effervescence5664 2 ปีที่แล้ว +1

    I saw this pop up on IG a few months ago, wondered when it would be released. The best thing about this is it's a game changer when you have no choice but to work live, nursing/care homes and hospital environments where people can't be turned off without risks to their lives. I wonder if it'll have the same anti-bac properties their current basic range has that we were asked to fit as standard for care/nursing homes. Time to get some literature on them I think.

    • @efixx
      @efixx  2 ปีที่แล้ว

      Its the same type of plastic Urea - so antibac properties are the same.

    • @effervescence5664
      @effervescence5664 2 ปีที่แล้ว

      @@efixx Ended up fitting some not 2 hours after posting. Brilliant kit, had a nursing home call come in, bed ridden resident on oxygen. What would take a team of nurses to move them so we could isolate power and replace a busted socket (basically a minimum of 2 hour prep) took less than 5 minutes with no need to turn the power off and being lever connectors with triple inlets far safer than holding cables in to screw. I thought their new basic antibac would be our go to range but this is now the go to socket for all call outs.

  • @mr8ball1st
    @mr8ball1st 2 ปีที่แล้ว

    Would you think there's a potential for screwless connections to ever come into consumer units, and if that would be a good idea?

    • @efixx
      @efixx  2 ปีที่แล้ว +2

      Yes - they already have them in Europe