how to check Ac Rotary compressor pumping 3 Type step by step || Ac कंप्रेसर की पंपिंग कैसे चेक करें
ฝัง
- เผยแพร่เมื่อ 6 ส.ค. 2023
- compressor ki pumping kaise check karen
how to test compressor pumping compressor pumping test
how to check compressor pumping Compressor ki pumping kaise check karen ac compressor pumping testing
how to check compressor pumping and leak back pressure
Excel cool
Compressor ki pumping kaise check karte hain
Compressor ki pumping kitni hoti hai
Great sir bahut achhi information di aapne
Bahut badiya se sir👍 aap samjhate hai thanku sir
Sir aap na bahut acha sa samjhaya hai ... nice 👍🏻 video
Bhut accha samjaya apne very good
Bohot khoob
Sab kuch clear hai
Sir thanks bahut badiya mera ac ka yahi Piroblam hai jab legaya tha to acch se cool kar rha tha par ab nahi kar rha hai yahi tirik karta hu subhe sir lokale ges ka bhi fark pad sakta hai kiya
Good information
Bahut achi trah bataya apne SIR.
❤❤❤❤❤❤❤❤❤बहुत,अच्छा से आप ने समझाया
Very nice
Very good
Very Excellent
Thanks sir ji
👌👌👌👌👌👌👌👌👌👌👌👌👌
Bahut acche se samajh Aaya Lekin dopahar Mein Thanda Nahin Hota aur sham ko Thanda Ho Jata Hai Aur Subah ke time Mujhe iska Karan bataen
Aap ne sahi tharike se samjhadiya.Good Job;very nice &useful class.hum bhi jiska inthzaar me tha.Aap ka bahth sukriya.❤❤
Good Information👍
Awesome great explanation
Really good information sir.
Yes
thanks bhyya
Good information sir.
Super sir gaed karne ke liye
Nice information👍
Good information brother
Good information👍
Thanks vai
Nice
Bhai aapki video acchi hai aap ek video out door to indoor wiring pe banaye please
Thanks sir 👍
System choking par video banaiye please sir.
Nice video sir
Nice explen ❤❤
👍 thanks
Nyc sir
Nice welcome sir
Very nice 👍
Nice work
Gazab ❤
check split AC invater model compressor pumping test
Good nowledge video
Very nice
Good 💯
Nice videos
❤🎉❤❤
Good 🌹
Good ❤❤
Sir Ac ke wairing ke bare mab batayen
Sir kya inverter ac ka bhi aise hi check krenge
आपकी वीडियो देखी बोहत अच्छी लगी और जानकारी भी मिली हमारा सवाल ये हैं की हमारी स्प्लिट ac जो की डेढ़ टन की हैं गोदरेज r 22 नंबर की गैस डालती हैं उसमे उसको ज़ब चलाते हैं तो कंप्रेशोर तीन मिनट चलकर बंद हो जाता हैं और फिर 6 मिनट के बाद कंप्रेशर चलता हैं और जून जुलाई मे तो हमें ऐसा लगता हैं मानो बस पंखा ही चल ही रहा हो
Phla answer.... compressor hota hoga koi problem hoga jo dekhne ke baad pta chlega....dusra......jun July me grmi bahot hoti h yishliya ye problem sav ke sath hota h kyuki grmi bahot krti h agr ye problem se bachna h to room ki capacity ke hisav se agr room me 1ton ac ki requirement h to 0.5 ton ka badha kr lagao fir July August me bhi mst colling kregi 👍☺️☺️☺️
sir third wala process inverter ac ke liye bhi apply hoga kya
Good
Or acha se btaye sir
Brother Dc compressor ko ya DC moter ko direct chla kr kaise check kr skte hai
कंप्रेसर की पंपिंग चेक करने के लिये refregrent उड़ाना पड़ेगा...?
Yes
Choking me amp, status kya rahega
Is outdoor me jo Realy wire connection Hai o samjao please
A bhi ho skta h. Suction line ka pin valv kharab ho skta h isi liye fak rha h
Sir self pressure kya hai
kon sa ball bund kiya tha sir app ne discard ball ya charge ball
Agar hamare copper pope me leakege hai to uuse brazing karne ka kya process hona chahiye.
Sir apki baat sub sahi hai par y baat saqte ho 410.gess hai ur gess chali gayi 80 parshent ur dhanda ek parshent bhi nahi hai Kiya problem ho saqti hai jawab de kar jana
Choking ki problem ho sakti hai
Sir aap na ya compressor ko alag kar ka bataya hai par ya charging line 450 prasser ghal Lage es Mai daut hai batao bake to sab theek hai
Sar Maine Ek Bar ac chalaya usmein pressure R 32 ka 120 point tha Uske bad Ek Bar compresser trip Ho Gaya FIR Dobara chalaya tha to uska pressure 150 batane Lag Gaya iska kya Karan ho sakta hai calling kam kar raha hai
Bhai pressure uda ke fir se vacuum karke acche se gas dalo aur 110 115 dalo r32 hai
You told in chocking psi will reduce but u didn't mention about the ampere conditions . It will increase or decrease?
Good🇺🇸🇹🇷🇺🇸🇹🇷
Standing pressure 22 150 Psi
Sir kisi samaya pumping down me compressor heatup vi ok amp vi badega
Compressor heat hoga amp down hoga
Sir compressor start nhi ho Raha hai to kaise short kar ke start karte ispe video banao plz
Sir R. 22. Gas paser 60 1.5ton.unit.windo.a.c amplJada. 12amp 10mint. Ka. Bad. Band. Ho. Ja raha hay fer dobara. 20mint. Ka bad start Ho raha hay
Chalu machine par aap na cheque Kiya tho aap na konsa wall band Kiya
Compressr.hett.ho.rha.h.service.kar.diya.back.p.60.h.cooling.nahi.kar.rha.h.amps.5.&6.le.rha.h.
Gaze meter 15 dikha raha he kya compressor thik he
है
No dot sir
Mujhe samajh nhi aaya hai acha se pamping kya huta hai or q krte hai
Pumping check karne m guage ka preassure pura hone pr pehle guage k value ko band krna chhaiye ya compressor ko band krna chhaiye
Jab app pumping check karenge to gauge band rahega gauge band kar ke hi pumping check hota hai gauge ka valve khula rahega to pressure bahar nikal jayega
@@excelcool6811 aur ac k system m preassure de rhe h to
Chokup hone par kya ampir bhi badege
Yes
compressor ki pumping kaise check Karen
Gas balb khula rahega tabhi system chala sakte hain balb band rahega to compressor nahi chala sakte hai to gas to udana padega na
😢❤❤❤❤❤❤❤❤❤🎉
sir aapne hme ye to bta fiya ke choking ka esa pta chle ga aapne theek btaya he pr ek smjh nhi aa rhi aapne ye btaya ke gej ka preshr 65 nhi dkhayega 50 ti ya 40 ya 30 dikhaye ga sir gej ka to bta diya mitr kiya btaye ga sir mitr kiya dikhaye ye or btao choking me dubara btayye sir hme accha se pta chle sir
Ampier tab Kam hota jayega
Chowk up kya hota h sir
Kahi pe gas rukta hai usko chok up kahte hai
Good job
Indoor me oil Chad Gaya ho to kaise pata chalega??
Indoor me cooling kam karenge indoor me oil chock hone suction pressure kam ho jata
Ek AC hai non inverter jiska running pressure sahi hai, outdoor fan heat bhi fek Raha hai, par andar cooling nahi hai aur customer keh Raha hai oil Chad Gaya hai full unit flashing karo. Kya problem ho sakti hai?? Usme Jo gas thi usi se indoor flash mara par thoda sa hi Oil nikla outdoor marna baki hai
AC chauk ho to kaise solve Karen
Service kar do thik hojaega but check v kar Lena bhai
My 2 compressor cheque kiya Mera compressor fail ho gya
R 22 ka standing pressure 150 rahta hai aur machine on karne ke bad bhi compressor ka standing pressure 150 hi rahta hai to bhi pumping Fail hota h
Bhai on karne ke baad jo pressure milta hai vo back pressure hota hai
@@shaileshkumarb9740अरे भाई वो क्या पूछ रहे हैं और तुम क्या बता रहे हो ध्यान से पढो की सामने वाले इंसान ने क्या पूछा हैं
@@vrcvlogger kehna kya chahte ho bhai explain
@@shaileshkumarb9740 मतलब ये की जिस को तुमने बोला की वो बैक प्रेशर होता हैं उसने ये पूछा हैं की अगर प्रेशर एक जैसा हो तो क्या पंपिंग फ़ैल मानी जाएगी क्या कंप्रेशर की
@@vrcvlogger are bhai compressor on hone ke baad jo pressure milta hai vo back pressure hota hai
Choack. Kaise pata chale ga
Sir agar gas ka pareshar bhi badh raha ho or compressor ke ampyar bhi badh rahe ho or compressor trip kar raha ho har 5 mint me to kya ho sakta h
Gas extra ho sakti h ya out condentior chowk ho sakta h
Or kuch iske alawa ho sakta h kya
Compressors kharab he
Unit ko alag alag nitrogen flush kro uske bad v amp jyada lerha hai to compressor kharab hai
Bad pirectis Compressor continue mosture suction karraha he
Sar Maine compresser change kiya tha r22 gas Thi usmein to 1 sal ki maine uski guarantee Liya Tha Ab usko fitting vagaira Sab maine kiya tha perfect chal raha tha aathvan dasvan Mahina 25 tarikh ko kiya tha abhi 2 din pahle mujhe call aaya ke compressor Fail Ho Gaya Karke main bola aapko Kaise Bulaya Maine outdoor niche Rakhe kam kiya tha usne dusre technician bulakar Upar Karke liya aur FIR vah Kuchh Khatna problem ki vajah se usne dusre technician ko Wapas Bulaya bad Mein Kabhi Usne To bolata compresser Gaya uska ab main uski guarantee 1 sal ki diya tha usne 1 Sal Mein Do Bar dusre technician Ko Bulaya Mujhe Nahin Bulaya uska guarantee Loom guarantee mein hai main karke de dunga Agar compresser ka lekin Sar usne Do Bar dusre technician se bulakar kam Kiya Hai to Mujhe uska Kuchh reason batao Sar Taki main Unse baat kar sakun unko bolu maine to unko bola bhai Jab kam tha to Mujhe Kyon Nahin Bulaya aapane upar Lagana tha outdoor ko niche se khol ke upar to aapane mere se Paisa poochha aur mere Se Koi dobarategi Nahin Kiya dusre se Karva ke liya ab Wapas band Hua Wapas Tumne dusre technician ko bola ke liya to Meri Kai ki guarantee hai to Sar batao Main Kya Karun unko check Karke Jao check Karu ya unko bolun jisse karaya usse karao
Bolo jis ko bulaya tha app ne unse hi kam kar ke lijiye Kyu ki ac pump down Kiya hoga ho sakta hai us time kharab hua ho
Jane ki jarurat nahi
Nice video sir
Good ❤❤❤
Thank you
Sir inhone 1st compressor me gauge mitter 250psi lo pressure lagaya hai or 350 Psi ka explain kar rahe hai or AAP good coment kar rahe hain please clear My dauat
Bhai dono gauge 500 psi ka hai
@@Bikaneriboydono gauge 500 psi ka hai ek bar chek karo
@@Bikaneriboybhai dhyan se dekho 500 psi ka gauge h
Nice
Amp 6 se 12 aur back pressure 50 se 100 ...10 minuts bad compressor band ho ja rha hai aur vale gauge se pressure niklne lag rha hai jab gess hata rhe h to plese batao koi kiya problm hai