Eng farman khan sahab maine suna hai compressor ka hwa m nhi chlana chaiye poor pumping chek krne k liy best sabse best trika hai systam m lge hue comprssor ko section line bnd krdo nitrogen ka 5 psi vecum krke daalo our condenssor m jha drier filter lga hota hai wha apna guge lgao agr 5 psi daalkr nitrogen ka pressur 140 k kreeb dikhara hai to hmara systam top kaam kr rha hai kiuki new compressor m bhi 7 psi nitrogen daal kr deti compny
Bhai Maine ye smjha thaa nitrogen Ka pressure bhot zyada hai blast ho jayaga but ESA nhi system ko vecum krke 5 psi bus issue zyada nhi our wo 150 dikhayga thik mana jayga
Sir please tell is there any difference between R22 1.5ton and R410a 1.5 ton capillary of air conditioners and as a whole difference between R22 and R410a capillary of ac
Yes of course, Capillary Tube in both ACs can be slightly differ from each other. For example for 1.5 TR AC R22, the capillary tube Length is slightly less length as compared to 410A. I will try to make video on overall difference b/w both R22 & R410A soon
@@FKmechofficial thank you so much can you you tell me the number of capillaries for 1ton r22 and r410a. 1.5ton R22 and r410a and for 2ton R22 and R410a capillaries please 🙏
@@prakashgotame8875 Rotary compressor back pressure air density ki waja se stand nhi kar pate, Leken reciprocating me back pressure stand karna zarori hai
Very nice video sir thanks
Thanks Dear Sir ❤️
Aoa farman bahi bht achi information di ha ap n jazak allah
Shukarya Bhai ❤️
It's useful for us
Thanks Dear brother ❤️
Please make a video about nitrogen pressure testing limits in split unit
Indoor and outdoor separately.
Ok Dear no problem
Good
Thanks Dear brother ❤️
Masha Allah sir very nice video
Aap gide Kary Kia R410 compresor my R22gas dal sakty Hy.
No brother, ye both gasses different properties wale hain, islie ye good practice nhi hai
Good video. Thankyou
You are welcome Dear
Eng farman khan sahab maine suna hai compressor ka hwa m nhi chlana chaiye poor pumping chek krne k liy best sabse best trika hai systam m lge hue comprssor ko section line bnd krdo nitrogen ka 5 psi vecum krke daalo our condenssor m jha drier filter lga hota hai wha apna guge lgao agr 5 psi daalkr nitrogen ka pressur 140 k kreeb dikhara hai to hmara systam top kaam kr rha hai kiuki new compressor m bhi 7 psi nitrogen daal kr deti compny
Bhai air pressure se pump testing acha practice nhi hai, but Kabhi majboori me agar ap karte hain, to no problem
Bhai Maine ye smjha thaa nitrogen Ka pressure bhot zyada hai blast ho jayaga but ESA nhi system ko vecum krke 5 psi bus issue zyada nhi our wo 150 dikhayga thik mana jayga
Excellent video
Thanks Dear Sir ❤️
Nice job
❣️
Good
Excellent good explanation
Thanks Dear brother for your valuable comments ❤️
Good information sir.
Thanks Dear
Sir please tell is there any difference between R22 1.5ton and R410a 1.5 ton capillary of air conditioners and as a whole difference between R22 and R410a capillary of ac
Yes of course,
Capillary Tube in both ACs can be slightly differ from each other.
For example for 1.5 TR AC R22, the capillary tube Length is slightly less length as compared to 410A.
I will try to make video on overall difference b/w both R22 & R410A soon
@@FKmechofficial thank you so much can you you tell me the number of capillaries for 1ton r22 and r410a. 1.5ton R22 and r410a and for 2ton R22 and R410a capillaries please 🙏
Sir my 3/4ton window ac bnana chahta hoo.
G brother ap bana sakte hain leken iske liye apko compressor, condenser, awr evaporator coils chote karne honge
Nice video
Thanks
R22 COMPRESSOR MA R410 gas fill kar sakta han
@@sohaib.s1573 no brother
Mashaallah
Thanks Dear brother
Are bhai Air or Refrigrent k presure mai fark hota hai isliye compressor presure back leraha hai .
Exactly brother, yahi to me bhi keh raha hon
Compressor pumping kese samajh koi notification ya formula hai
Discharge Pressure SE 100 Psig km tk agar air pressure se check Karne hai
Assalamu alikum
Wa Alaikumussalam
Ampair kam kana chahtahoo
Sir refrigerant k sath kaise pressure check kare
Agar R22 Ka compressor air pressure testing me 250 Psig tk pohnchta hai...
To refrigerant bhi teek hi hoga...
R407 ka kitna ma standing hoga chahiye back hona naii chahiye sir and 134 and 404 ka kitna hona chahiya
@@prakashgotame8875 R407C awr R22 same Hain...
Awr
R134a, R404a kelie Reciprocating compressor use hote hain
@@prakashgotame8875 Rotary compressor back pressure air density ki waja se stand nhi kar pate,
Leken reciprocating me back pressure stand karna zarori hai
R22hermatic compressor pumping pressure
Back pressure hai to thik kaise hai.
Air pressure ki density high hai Bhai islie back pressure ho Raha hai
❤❤❤❤❤❤
❣️❣️
❤❤❤
❤❤❤
❤❤❤
❣️❣️
Aoa
Thanks
Thanks
H.B.P COMPRESSOR KA PUMPING PRESSURE LYA HOTA JAI
HBP awr LBP dono me same tariqa Kaar hai.
Aoa
G