  • Wye-Delta starter Motor control Circuit.
    if you press start button,”wye contactor energize same time with omron timer on delay after 5 seconds, wye de energize and delta contactor energize.
    Wye connection is soft start the motor to prevent over current, and not damage the belt,coupling shaft, keyway, pully.

ความคิดเห็น • 38

  • @thatsmydogbuddy
    @thatsmydogbuddy 6 หลายเดือนก่อน +1

    I love it! You made this 2 years ago and I just found it now that I have a need for it. Another great video! Thank you for sharing your knowledge!!!

    • @tmelectricaltutorials2851
      @tmelectricaltutorials2851  6 หลายเดือนก่อน

      thank you finally you found my channel you will learn motor control wiring installations

  • @mohamedboulakhrif6602
    @mohamedboulakhrif6602 6 หลายเดือนก่อน +1

    Good teacher and good technicus thnk you

  • @cdalisayvlog9811
    @cdalisayvlog9811 2 ปีที่แล้ว +2

    Nice diagram master i learn a lot to your tutorials

  • @leondioquino4241
    @leondioquino4241 2 ปีที่แล้ว +2

    Thank you professor all videos you shared I learned a lot . I try to instaĺl motor control Wye delta starter.

  • @danielbartolome8807
    @danielbartolome8807 2 ปีที่แล้ว +1

    Maraming salamat sa Motor control na ito master malakeng tulong ito , god bless po.🙏

  • @stonedsloth6367
    @stonedsloth6367 ปีที่แล้ว

    great explanation and demonstration. Thanks.

  • @joewebb4836
    @joewebb4836 ปีที่แล้ว

    I believe soft startearnlers have removed the need for this configuration, but important to learn in case you have to repair.

    • @tmelectricaltutorials2851
      @tmelectricaltutorials2851  ปีที่แล้ว

      we some startvalve motors we use soft start seimens and allenbradly. instead wye delta connection. but better you must know and learn how to connect specially for the beginners.

    • @tmelectricaltutorials2851
      @tmelectricaltutorials2851  ปีที่แล้ว

      this motor control wye delta connection is very important to learn mostly used on big motors. if you know the connection you know how to troubleshoot and install or connect.

    • @garbo8962
      @garbo8962 ปีที่แล้ว

      No VFD'S have replaced them. They save an enormous amount if power whenever they are running at less then full speed. We had hundreds if VFD'S from 2 to 1,759 HP. All of the air a handlers ( 50 to 150 HP & Return air fans ( 20 to 125 HP ) were able to run at only 50 to 60% of full speed at nights & weekends thus only using maybe a third amount of a full speed motor.

  • @morrismaneae3634
    @morrismaneae3634 2 ปีที่แล้ว +1

    Very helpful.thnkz

  • @yousefalmuzini7150
    @yousefalmuzini7150 ปีที่แล้ว

    thank you for effort , really appreciate it

  • @victordelacruz4906
    @victordelacruz4906 2 ปีที่แล้ว

    Very useful this motor control and motor connection sir thank you

  • @ilopez7372
    @ilopez7372 2 ปีที่แล้ว +1

    Professor paki gawa ng video ng overhead cranes na gamit ang VFD . Paki explain ng circuit diagrams at pag program ng VFD. Salamat .

    • @tmelectricaltutorials2851
      @tmelectricaltutorials2851  2 ปีที่แล้ว

      Makakawa ako ng video tutorials nyan wiring installation pero wala VFD . Hindi pwedeng lagyan ng vfd drive ang hoist or crane. Ibat ibat company pinang galingan ko walang may variable drive ang hoist.
      Not safe with vfd drive ang crae or hoist.

  • @steveochieng6517
    @steveochieng6517 2 ปีที่แล้ว +1

    Great

  • @chidiemelobe1044
    @chidiemelobe1044 ปีที่แล้ว

    Thank you.

  • @tadiosnyamuziwa5679
    @tadiosnyamuziwa5679 2 ปีที่แล้ว +1

    Thank you Master once more for the lecture. I have two questions:
    Are 8 and 5 the normally closed timer connections?
    Are 8 and 6 the normally open timer connections?

    • @tmelectricaltutorials2851
      @tmelectricaltutorials2851  2 ปีที่แล้ว

      Yes you’re right,” terminal 8 and 5 is normally cloes and terminal 8 and 6 is normally open.

  • @tadiosnyamuziwa5679
    @tadiosnyamuziwa5679 2 ปีที่แล้ว

    Many thanks Master for the excellent presentation. How is the time delay calculated in a Star-Delta set up? What I am trying to say is that how did you come up with 5 seconds? Why didn’t you select 7 sec for example.

  • @tadiosnyamuziwa5679
    @tadiosnyamuziwa5679 2 ปีที่แล้ว

    Great video Master. Is it okay to also use (1;5), (3;4) and (2;6) on the delta connection instead of using (6;1), (3;5) and (2;4) ?

  • @dodst.v4833
    @dodst.v4833 2 ปีที่แล้ว +1

    sir tama ba 1&6/2&4/3&5 delta po paano po pag letter po ang marking sa delta