Hello Friendz I will back with a new video in which I will show how to check transformer using some simple tips and tricks
Hope You like
A N D
Do not forget to Subscribe our Channel - วิทยาศาสตร์และเทคโนโลยี
You shouldn't hold the wires with your hands when you measure ohms. Your body is a resistor and can affect the results. Alligator clips on your multimeter are better.
Thank you just what I needed to know. My transformer doesn't have any markings on it to say which is power in & out. Thanks again !!
thank you .your video was the best for me to understand.
THX you helped me
Well done
5 ways it seemed like. Thanks
very good checking
question: I have a 100W soldering gun, I seemed to stop heating up. I changed the tip and still nothing. I tested for current going in, It has. I tested the light bulb for current, It works. But I fear its perhaps the transformer part, How can I test that part?
nice...
Thanks
Well done bro
Nice starting
Thnxx
Well done Sir it is ok to use voltage transformer for battery charger assembly for motorcycle?
Sir I got 13.8v while testing in current. Is there any problem in my transformer
What ???
You got 13Volts.......... While testing in Current Mode
How is that possible ?
if your Multimeter is set to A then you cannot get a reading that reads V AC or V DC
for that to happen your Multimeter must be set to V AC or V DC
if you thought you were testing the current but had the meter in Volts mode then YOU WERE ACTUALLY TESTING VOLTS
also, Were you testing IN-SERIES or IN-PARALLEL
Because In-Parallel is a VOLTAGE Test
Current Must be Tested In-Series
which did you do ?
from iraq thanks for your explantion
Kalo cara cek transformer input 380v dan auoput 36 v itu gmn pak
I've checked transformers which in primary have about 1.4Kohms. 1st test should be done with the 2Kohms scale. A test of 0ohms is for shorted coil, and 1 or L in the left si de of the display (infinite) is for opened/broken coil. Thanks for the video.
resistance of primary and secondry coil of transformer can't be a scal of KOHMS. the only explanation is that your coil is cut off
oven transformer k bary m kush btae
How could I know whether the transformer is 12volts or 17volts output ?
measure it with the multimeter on AC setting
jab load daalo gy transformer py tou pory 12v dc milty hen....jaahil
bhai background music ka name kyah ha
Sir please tell me what is the amp of the transformer
pro tip: watch movies at Flixzone. I've been using them for watching all kinds of movies during the lockdown.
@Lorenzo Jabari yup, have been using Flixzone for since december myself =)
Mere paas old philips company ka DR 579 stereo radio recorder hai.
Bhai ismai out put mai positive or ground wire kon see hai,kya hum koi b wire positive mai use or skte h
Yes
Thanks and
17 volts on the secondary side is ok?
video dalte raha karo
Hello sir
Mera ek sawal hai aapse, ki Mere paas purane radio ka transformer hai to use check kaise kare.
Aur ek issue hai usme, ki use wire bhi nahi lagi hai.
Mujhe plz upay batao, ya fir ek video send karo.
need check tranformer if value vmc-1 need change to
tell me background song
Excellent video.Does all transformer of speaker gives same value on primary sec?..I am getting 442 ohms.
Is transformer OK?
Please guide.
4.1 home theatre aata
Sir ye
karent nhi Marta h
On me testing karna hai
HELLOW S KUMAR, maine aapko ak mail kiya hai, akber check karlijia...
Why you are selecting Ac
OK
TRANSFORMER BASICS...
1. A Transformer is an inductor
2. Watch a you tube video on HOW DOES AN INDUCTOR WORK
3. An inductor is basically a wire and if you feed DC Voltage into it it will behave like a dead Short
because the wire has low resistance
4. However if you feed AC Voltage into it it will store Current in the magnetic field
5. Now if you bring another inductor with less windings close to the first one, THE ENERGY WILL BE INDUCED INTO THE SECONDARY COIL
6. Therefore DC VOLTAGE CANNOT FLOW THROUGH A TRANSFORMER.
ONLY AC VOLTAGE CAN FLOW / INDUCE FROM ONE SIDE (THE PRIMARY SIDE) TO THE OTHER SIDE (THE SECONDARY SIDE)
7. Since Only AC can pass through the Transformer YOU SELECT AC VOLTS on your Multimeter to Measure the output voltage on the secondary side
THAT'S WHY YOU SELECT AC
My trnsfrmr output showing 1 volt to 2 volt so how to repair or what is falt
Omg this video is too dangerous take care thire voltage is 17 some transformer give more than this 24 48 110 which is not a joke to catch it like this
Bhai, mere 6v transformer me secondary side me reading dikha raha ha par primary side me nahi dikha raha ,what's the problem ?
Это что было?
What language is this?
@@velmurugans8076 chuvash language
what you checked. what is the purpose. your subject . and you checked ok ok ok . wwhat you are teaching to the society.
Bro he Just taught Us To Check Transformer Is Working Or Not
If It Working, This Show like above Video
Aur If It Is Not Ok
Only For Those who want To Check His Transformer if he Found it in his/her old radios aur amplifier
If Got That Like
😅
pessimo esempio attaccare i fili alla 220 volanti
not safe ur check
వాయిస్ లేకుండా వీడియో ఎందుకు చేస్తారు , మీకు మాటలు రావా?
Bakwas hai
tell me background song