  • @kctyphoon
    @kctyphoon 4 ปีที่แล้ว +36

    I’m just impressed someone finally knows which is the right way to apply pressure with channellocks. BTW - i love all the armchair critics that sit around looking for stupid things to pick apart - like “tearing up a fitting” (cause teeth marks were left on it) that will probably be turned twice over the course of 30 years. Not to mention the guy CLEARLY stated this was a video guide to make something that might seem intimidating for a homeowner, look easier by using the most simple tools around... Given the choice of paying somebody hundreds to hook up 3 lines, and getting ripped off on the water heater itself, ill go out on a limb and say the homeowner will be happy someone showed them how easy this can be.

    • @bigblue3568
      @bigblue3568 4 ปีที่แล้ว +2

      Farmers Insurance... commercial. "Installed your own natural gas hot water heater with TH-cam Instructions skipping gas leak check?" We covered that. Kaboom!

    • @buzzincalifornia
      @buzzincalifornia 4 ปีที่แล้ว +1

      I don’t believe that not checking for gas leaks is a “stupid thing to pick apart” Paying someone “hundreds of bucks to hook up three lines” to save your family’s lives in an explosion and fire at 3 A.M. if you don’t know what your doing is a great investment. in. My opinion, So many errors in this video presentation makes it almost useless

    • @kctyphoon
      @kctyphoon 4 ปีที่แล้ว +12

      @@buzzincalifornia you have a better chance of hitting the lotto 3 times in a row, then a house 'exploding' from a gas leak so small you need to check and see if it's even there. So please stop with the fantasy scenarios. Keep your California opinions in California ;)

    • @nickbinetti3796
      @nickbinetti3796 3 ปีที่แล้ว

      @@bigblue3568 &

  • @paulafantulin7152
    @paulafantulin7152 6 ปีที่แล้ว +20

    Thank you !! My son and I watched your video several times, made notes, bought what we needed and had 100% success for a couple of newbies. We use the Teflon tape, we checked for. gas leaks with soap ( no bubbles!) I finally got my hot shower after 2 weeks of cold ones. Thank you!!

  • @gman8260
    @gman8260 5 ปีที่แล้ว +37

    You can leave the plastic sleeve in the Sharkbite when using copper. From the Sharkbite Installation manual "The PEX Stiffener is not required for use with CPVC and copper tubing, however these two types of tubing fit over the PEX Stiffener easily and hold it against the tube stop". So you can leave them in. Should have deburred the inside of the copper pipes where they were cut.

    • @wilowilo9462
      @wilowilo9462 2 ปีที่แล้ว

      Can I ask you something do you know where is the anode rod on the tank he is putting in I got that same tank

    • @69ztang
      @69ztang 2 ปีที่แล้ว +2

      @@wilowilo9462 check for a 1 1/16? bolt head on top. Should be the anode.

    • @mabahokano7567
      @mabahokano7567 4 หลายเดือนก่อน

      ​@wilowilo9462 weld spot at the center of the bolt indicates magnesium (best) vs aluminum (acceptable)

  • @NorthlanderMN
    @NorthlanderMN 2 ปีที่แล้ว +2

    This is the best video explaining the details. Excellent video!

  • @jackonthefarm5540
    @jackonthefarm5540 2 ปีที่แล้ว +10

    You said the cold water pipe is connected to an anode rod. Actually, the cold water is connected to a pipe that delivers the incoming water to the bottom of the tank so you don't disrupt the thermal stratification in the tank. The hot water rises to the top, and the cold water should always be at the bottom. The house draws from the top of the tank where the hot water is due to stratification. The sacrificial anode is usually another fitting on the top of the tank.

  • @Rayram555
    @Rayram555 5 ปีที่แล้ว +3

    This man knows what he is doing. He is using the correct materials for this job. I use this method all the time and I never had a problem.
    shark bites are tested and approved. Soldering is time consuming and cost a lot of money in labor. That is why there are shark bits pex fittings and crimp on.
    Thank you sir for the video.

    • @addictedgamer8833
      @addictedgamer8833 5 ปีที่แล้ว

      You are either unlicensed, or have had horrible training. This video is absolute trash.

  • @ericengstrom8207
    @ericengstrom8207 2 ปีที่แล้ว +2

    Craig, you are fantastic! Your video is the best instructional video I've ever watched on TH-cam.Our hot water tank is shot, and it quit on a Saturday. We used Angie'slist to help find a Plumber; their prices were ridiculous. Your video helped immensely. Also, Thank you for your service to our country!

    • @dorothysatterfield3699
      @dorothysatterfield3699 2 ปีที่แล้ว +3

      The prices ARE ridiculous! I tried getting the tank and installation at Lowe's in Wilmington, Delaware, today. They arranged for their installer to call me -- he would be doing the delivery as well. I had chosen the A. O. Smith 40-gallon short gas HW heater, which Lowe's sells for $579. He quoted me a price of $1,481. That's $900 for installation! Hah! No way. I'm a 69-year-old woman, but I've always done all my own plumbing. I installed a HW heater about 25 years ago and at that time I sweat-soldered the copper pipes -- it's actually kind of fun to do, but the shark-bite connections look a lot easier. Just replaced my old iron toilet flange and installed a new toilet last week. So I think I'll be able to save myself 900 bucks. This video was great!

    • @RICDirector
      @RICDirector 2 ปีที่แล้ว +1

      Thank you for posting; you and the video give me hope that a young friend and I can do this despite my physical issues. Enjoy your hot watet, heres hoping Im doing the same by next week!

  • @alimaleki217
    @alimaleki217 4 ปีที่แล้ว +8

    Not sure if you did this but you have to remove burrs from the copper tube you cut before you insert the SharkBite connector or you could damage rubber seal.

  • @brianwhitis9390
    @brianwhitis9390 ปีที่แล้ว

    Great instructor.

  • @GPa141fe
    @GPa141fe 3 ปีที่แล้ว +2

    Hey Army, thanks for the simple to follow, basic instructions for replacing a gas hot water heater. Do some of the commenters have valid points? Absolutely, but I for one never rely solely on any one youtube video or google searched set of instructions to attempt a project I've never done before. I would say, learn from their informed points, but ignore the juvenile, condescending remarks which aren't helpful to anyone.

  • @jaimecordon9511
    @jaimecordon9511 ปีที่แล้ว

    Thank you you just made all my insecurities go away and saved me about $500 🎉😂😅

  • @dilippatel3268
    @dilippatel3268 4 ปีที่แล้ว +1

    excellent video

  • @ginobean737
    @ginobean737 4 ปีที่แล้ว +9

    Did you consider using compression fittings instead of sharkbite? The compression fittings would be just as easy to put together, cheaper, and generally more reliable than sharkbite fittings, over the long run..

    • @briankoeler2417
      @briankoeler2417 2 ปีที่แล้ว +1

      I used compression fittings on mine.

    • @dominictam9293
      @dominictam9293 ปีที่แล้ว +1

      I used compression fitting on mine.

    • @ginobean737
      @ginobean737 ปีที่แล้ว +1

      That being said, I am actually using a sharkbite with a ball valve attachment, to connect to my hot water heater cold inlet side. No issues so far. I think the trick is to following the installation directions carefully, and only use them in easily accessible, easy to monitor locations.

  • @barryspindler8342
    @barryspindler8342 7 ปีที่แล้ว +5

    Thanks for the clear audio, good visuals and overall high quality in this video.

  • @huongyn8808
    @huongyn8808 9 หลายเดือนก่อน

    Awesome!!! The best video on TH-cam for natural gas water heater installation!! Could you tell what part number at Home Depot for the fitting without soldering ? Much appreciated for your sharing!

  • @dave1uofm
    @dave1uofm 5 ปีที่แล้ว +17

    I thought when using the Teflon tape with gas lines had to be the yellow tape. Great video very helpful.

    • @WhiteFox011
      @WhiteFox011 5 ปีที่แล้ว +1

      I know that the yellow tape is required on propane gas lines, not sure about natural gas. I have been towing and maintaining RV's for over 40 years, one tends to learn a thing or two along the way. Gas lines, water lines, 120 VAC wiring, and 12VDC wiring. Thankfully most RVs have gone to using PEX TUBING FOR PLUMBING.

    • @edsfb
      @edsfb 2 ปีที่แล้ว +2

      White - Basic Thread Seal Tape. ...
      Pink - Thread Seal Tape For Water Lines. ...
      Yellow - Thread Seal Tape For Gas Lines. ...
      Green - Thread Seal Tape For Oxygen Lines. ...
      Grey - Thread Seal Tape For Stainless Steel.

    • @rodgraff1782
      @rodgraff1782 2 ปีที่แล้ว +2

      Actually, you should never use Teflon paste or Teflon tape on gas lines. If you are not careful it gets into the gas control valve and cause it to malfunction. I would use yellow rector seal pipe dope. That’s the code in our area. No Teflon on gas.

  • @yourfavoriteforeignmovie4167
    @yourfavoriteforeignmovie4167 5 ปีที่แล้ว +3

    Awesome video. Thanks for helping us all out. Dig the reggae too.

  • @warriorfreedom4755
    @warriorfreedom4755 ปีที่แล้ว

    Thanks for your great video. I didn't see you tightened the connectors for the water lines. You don't need to tighten them?

  • @dinokarakostas6407
    @dinokarakostas6407 2 ปีที่แล้ว

    Thanks for the tutorial. I have the same Bradford white tank and you saved my life with this video.

  • @joeflanagan174
    @joeflanagan174 3 ปีที่แล้ว +2

    Hey great video. Thanks for your time. I've seen a few options for R and Ring a tank. There is your demonstration with shark bite and flex gas line. There's the anti-burst SS H and C lines, with flex yellow gas line, and finally, the tried and true old fashioned hard plumbed, soldered. I used to believe the best was the hard plumb, but recently hearing the the braided SS lines and flex gas line are SAFER, given the earthquake considerations, vibration and danger of tipping. I am able to solder, but is there a "best" method you would recommend, as a pro plumber, taking into consideration the above concerns? Thanks again for your time!

  • @lrob1420
    @lrob1420 3 ปีที่แล้ว +1

    Well put together. Best I’ve seen. TY.

  • @jameskelly2777
    @jameskelly2777 3 ปีที่แล้ว

    You have a gift for teaching my brother very thorough

  • @ronh9384
    @ronh9384 4 ปีที่แล้ว +2

    Good video! Also noticed the hat. Go Army! 😊
    Ron

  • @smithwesson4522
    @smithwesson4522 4 ปีที่แล้ว +2

    Like the Video,just wondering why gas water heater was layed on its side and slid off the Truck? it says on the box "DO NOT LAY ON ITS SIDE" Must be transported/stored in Vertical Position? Does it matter/make a difference???

  • @fasteddie9475
    @fasteddie9475 4 ปีที่แล้ว +2

    Great video, you do a good job explaining, probably should check the flue pipe to make sure it is drawing gases out properly, don't want to kill anyone LOL.

    • @rodgraff1782
      @rodgraff1782 2 ปีที่แล้ว

      That flue pipe seems to be oversized for the water heater. Should be a 3”. That affects the draw. Better get a draft gauge and check that.

  • @3Dprint4you
    @3Dprint4you ปีที่แล้ว +1

    One of the best videos on TH-cam for doing a hot water heater. I love how you present theings and are very thorough and clear in your directions. Thank you very much for getting me through the change!

  • @genesis80247
    @genesis80247 7 ปีที่แล้ว +12

    thank you for the video really good how you explain the process

    • @MechanicMike64
      @MechanicMike64 5 ปีที่แล้ว +1

      please do not take this twit at his word he is a hack and gives good tradesmen a bad name this is coming from a 24 yr lisn. tradesman and teck teacher now retired but no matter what state you are in this moron needs to go to jail or something, there are only 2 pros in this world that have to take a hippocratic oath and they are docs and plumbers to protect the health and well being of the nation! look it up !

    • @MechanicMike64
      @MechanicMike64 5 ปีที่แล้ว

      i'm not good at this u tube help me to know how to help better!

    • @jameskitzmann6268
      @jameskitzmann6268 5 ปีที่แล้ว +2

      @@MechanicMike64 What is so terrible with this install? I see not reaming his copper. Expansion tank and drip leg may not be required in his area. T and P may not be required to drain outside. Could it be better? Yes, Is it awful or dangerous? Not in the least unless you see something else.

  • @dansklenicka8403
    @dansklenicka8403 4 ปีที่แล้ว +1

    Well spoken video Thanks !

  • @ffinkral
    @ffinkral 4 ปีที่แล้ว +2

    This video was so useful! Thank you!

  • @pm1035
    @pm1035 5 ปีที่แล้ว +3

    Hey thanks for that great video! Do you have to remove the plastic thing in the Shark Bite? or is that just your prefernce?

  • @johneasterbrook7877
    @johneasterbrook7877 5 ปีที่แล้ว +4

    Excellent job!!! Nice and instructive video. Good stuff!!

  • @jamessang5027
    @jamessang5027 4 ปีที่แล้ว +1

    Good video, it was detailed!

  • @fishongethenet
    @fishongethenet 2 ปีที่แล้ว

    Great video! Thanks!

  • @sprogbog1197
    @sprogbog1197 5 ปีที่แล้ว +28

    Did you take out a permit? A few mistakes to boot I am a licensed gas fitter the B vent your on about is actually C vent and looks like hell after you connected it. Yellow tape is for gas white is water and air only the white tape is permeable to Natural gas and will leak. Always always soap up your fittings after turning on the gas not sure where your nose was trained but its just standard practice to soap the fitting up a fitting may be cracked due to over tightening. You are required 18 inches of copper pipe connected to the tank the heat will affect the plastic pex piping. And I hope to hell you didn't use the old draft hood off the old tank. I was called out to a house a women and baby where being poisoned by carbon monoxide the plumber had installed the old draft hood on the new tank and the gas was not combusting properly inside the new tank and spilling into the house causing a major Hazard could of killed the occupants. Also you should have piped the relief line over the drain hole if it goes off it will cause a major flood. And I would never use those shark bites expensive and not necessary soldering a couple of couplings is easy.

    • @FredD63
      @FredD63 2 ปีที่แล้ว +1

      Exactly 👊🏼 many shortcuts that we get called back to repair the right way … use pipe dope not Teflon tape and never reuse the old hood

    • @KnowingGodExplorers
      @KnowingGodExplorers 3 หลายเดือนก่อน

      Finally ....thank you.
      Absolutely agree with your statement. I've been coming behind this guys videos trying to advise people to be careful. Why people would trust their families lives and home damage just because they want to save a few bucks. Then they go on line, find videos like these and risk their safety. Trust a certified installer.

  • @TonyWadkins
    @TonyWadkins 5 ปีที่แล้ว +18

    The anode rod on a Bradford White is part of the hot water outlet not the cold inlet. All other manufacturers use a separate bung hole for the anode only.

    • @rawbacon
      @rawbacon 5 ปีที่แล้ว +2

      No wonder I don't see one on mine, It's over 15 years old, not sure it's worth changing now.

    • @RayleighCriterion
      @RayleighCriterion 4 ปีที่แล้ว +1

      @@rawbacon The sacrificial rod usually needs to be changed after 5 to 6 years, my hot water tank is 21 years old now and I've never changed the rod.

    • @rawbacon
      @rawbacon 4 ปีที่แล้ว

      @@RayleighCriterion I think I'll just leave well enough alone.....Everything is working A-OK no point in messing with it after all these years.

    • @mabahokano7567
      @mabahokano7567 4 หลายเดือนก่อน

      ​@@RayleighCriterionmagnesium lasts a few years longer than aluminum

  • @tboneproductions2453
    @tboneproductions2453 3 ปีที่แล้ว

    Great video. Straight to the point. You da man!

  • @Thatplumberguy1995
    @Thatplumberguy1995 6 ปีที่แล้ว +23

    I wouldn’t put my name or company name on that job. Take some damn pride in your work man.. Way to make us good plumbers look bad..

    • @mikechirhart8840
      @mikechirhart8840 5 ปีที่แล้ว +4

      There's no way this guy has a plumbing license

    • @mikechirhart8840
      @mikechirhart8840 5 ปีที่แล้ว +2

      @Rusty Neither is operating a motor vehicle but one still has to take a test and obtain a license to operate one. If I didn't have license and wanted to make a "how to" video, I'd make damn sure that I was doing everything correctly and following code/law. I don't think I could live with myself if I found out somebody got hurt or died after watching a video that I created. Making a video like this is just plain irresponsible and potentially dangerous.

    • @mikechirhart8840
      @mikechirhart8840 5 ปีที่แล้ว +3

      I'm a licensed plumber. In the trade for over 30 years. Most codes are or are in the process of becoming Universalized nationally. I know the codes. That's my job. So , yes, I do say this installation is not up to code. It would not pass inspection. The installer could be fined and warned never to perform such work without the proper licenses or face legal prosecution. You see, these codes are put in place to protect the public from hacks like this. It's also the reason licenses are required for someone to perform this type of work. A homeowner has every right to his own work on his own property. And there are plenty of videos on TH-cam that are great and show a proper, code compliant, and safe way of installing such equipment. This is not one of them. And by looking at the vast amount of negative comments for this video, I'm not the only one who has this opinion. I'm not a drama,queen. I'm a professional tradesman looking out and trying to help and protect people who want to save a few bucks by installing their own plumbing and plumbing equipment. And if I see a video that I think is not of goid standards, I'm going to let the public know it. I feel that it's not only a good idea to do so, it also my responsibility. This guy is a moron. He talks the talk but he don't walk the walk. You can argue all you want with me. It just shows you're not very knowledgeable about this sort of thing.

    • @karenflowers9711
      @karenflowers9711 4 ปีที่แล้ว +5

      @Rusty I am a 63 y.o woman who has learned how to fix my own boiler, replace copper pipe and now will be replacing my hot water heater. I laugh my ass off when I think how I used to believe this stuff was hard. Anyway.....

    • @blue03r6
      @blue03r6 4 ปีที่แล้ว +2

      @@mikechirhart8840 you realize that there is no codes stating a homeowner isn't allowed to install a hot water heater right? for you code means job security. that's why you guys push for it. some places make you obtain a final inspection like where I live. however I doubt that would fail. you know how I know? my hot water heater looked about like that with the flu crooked because of a beam above. my home passed a home inspection done by a inspector from the FHA and a hired private inspector that was doing the upgraded more strict inspection. sharkbite fittings are also the new codes. pex, cpvc, pvc etc, thats all fittings, glue and plastic too. so when I see you guys bitching about guys using this stuff makes me laugh. you're using it too but think you required special training to use simple shit. those push together fittings are also all over cars. have been for decades. from water hoses, brake lines, fuel lines, clutch lines. my old truck you was just a plastic coupling for the heater core. you could literally move the pipe around but it never leaks. and 99% of these videos the plumbers found the easiest one to work on to show off their mad skills. lets see you all do one in a closet around a bunch of other pipes and beams that cannot be moved. or one that some hack has 2 different line sizes in it. all you guys do is make videos of the 1% installs you ever do. the rest of them probably look like hack jobs. why would the flue need checked if it was already working in the first place? that house looks less than 20 years old. I'm sure it was built with all this in mind. although I'm surprised its not a power vent water heater.

  • @Timothyrucker12
    @Timothyrucker12 3 ปีที่แล้ว

    I’m a new subscriber

  • @erwinbenally8027
    @erwinbenally8027 6 ปีที่แล้ว +12

    Hey man, good job, I appreciate your time and effort

  • @thensr2011
    @thensr2011 หลายเดือนก่อน

    Will crossed supply lines prevent the discharge of Hot water from a newly installed full electric water heater?

  • @bjjbrawler1
    @bjjbrawler1 3 ปีที่แล้ว +1

    So helpful! Thanks so much for making this! I already did my install/ replacement but this is such GREAT info for the future.

    • @briankoeler2417
      @briankoeler2417 2 ปีที่แล้ว

      Same here. More detail than many others I watched prior to doing mine. I used compression fittings instead of shark bites.

  • @Dhi-fe5eu
    @Dhi-fe5eu 5 ปีที่แล้ว +1

    Great video, what could happen if u left the plastic sleeve in the shark bite fitting when attaching to copper?

  • @glendurant911
    @glendurant911 ปีที่แล้ว

    Is the teflon tape o,kay for Gas fittings or is there tape for gas specificaly.

    • @realexperiences8748
      @realexperiences8748 ปีที่แล้ว

      Gas fittings get Yellow Gas PTFE tape. I also like to lubricate it with Rector Seal No. 5, which is also yellow and good for gas. A little pipe dope like that will help you twist in on tighter.

  • @andydavis1679
    @andydavis1679 5 ปีที่แล้ว +2

    The best video I have ever watched on TH-cam - very complete in his descriptions and easily understood because he doesn't talk "above" the average homeowner. Thanks.

  • @josephtorres4139
    @josephtorres4139 6 ปีที่แล้ว +3

    Appreciate the video. Thanks!

  • @4KDisneyTV
    @4KDisneyTV 6 ปีที่แล้ว +23

    I’ll save you the 29 minutes. Go buy shark bite water heater flexible braided hoses. Comes with new shut off valve also on them.

    • @crand20033
      @crand20033 5 ปีที่แล้ว +1

      Do those hoses have to be made of copper to avoid the dielectric response causing corrosion between the hoses and the copper pipes?

    • @4KDisneyTV
      @4KDisneyTV 5 ปีที่แล้ว +1

      Don’t know. Shark bit has been around for a long time now and haven’t heard of anyone saying they failed.

    • @anthonywilliams3048
      @anthonywilliams3048 5 ปีที่แล้ว +5

      As a plumber i have seen several of the braided hoses fail. And with water pressure shot holes thru the sheetrock causing a lot of damage. Would never use them.

    • @bigweiner92
      @bigweiner92 5 ปีที่แล้ว +4

      This guy didn't even install the tank to code and sharkbites are garbage. I've seen them fail numerous times

    • @williamknighton7416
      @williamknighton7416 5 ปีที่แล้ว +2

      Real plumbers don't use shark bites or braided supplies lines on water heaters. Those are only used by lazy amateurs

  • @VideoNOLA
    @VideoNOLA 7 ปีที่แล้ว +15

    Sharkbite and other manufacturers strongly recommend deburring (not done in this video) and cleaning (also not done) the ends of cut copper tubing before inserting into their connectors. They also stress the importance of marking the insertion depth (typically 1 inch) with a permanent marker so that (a) you know you've (re)inserted it deeply enough (#1 mistake!), and (b) a plumbing inspector can readily see that you've done so (and knew what you were doing).

    • @farmeunit
      @farmeunit ปีที่แล้ว +1

      @K.M.V S What failed on them?

  • @computergeeksrepair
    @computergeeksrepair 5 ปีที่แล้ว +2

    no sediment trap required?

  • @glennsmith6380
    @glennsmith6380 4 ปีที่แล้ว

    Great video

  • @smartplumber5570
    @smartplumber5570 5 ปีที่แล้ว +1

    Very nice!
    Thank you!

  • @bonnieebrown
    @bonnieebrown 6 ปีที่แล้ว

    Thank you for this well-done video. I'm not going to change out a water heater, but I'm going to install a hot water recirculator pump on my few-months-old heater, and this has given me the courage to attempt it. When I got a quote for the water heater, I also got an estimate for the recirculator, and that alone with labor was going to be about $1,000. I just bought a recirculator for $160 from a hardware store that's going out of business. My heater's hot water outlet has one of those flexible copper tubes, so the installation won't be too difficult, I think.

    • @eirizarry2568
      @eirizarry2568 4 ปีที่แล้ว +4

      Same here.....new water heater $340......labor $ 1,000 removal of old tank $ 60, total $1400......labor is crazy....And I thought my attorney charged me a lot.

  • @anthonybatshon3715
    @anthonybatshon3715 3 ปีที่แล้ว

    Your very good

  • @kajekage9410
    @kajekage9410 ปีที่แล้ว

    I'm confused about the sediment tap. Is that just the hose connection at the bottom? And did you keep the water on to keep pressure? If you did that how did the tank fully empty?

  • @younggypaik8927
    @younggypaik8927 6 ปีที่แล้ว +6

    You have explained the process very well. Thank you for posting the video!

  • @michaelt721
    @michaelt721 6 ปีที่แล้ว +1

    Great video, very informative. I was wondering what the valve on the cold water line was for, or what is that called. Not the water valve but the other one with the black handle. Thank you

    • @critterwhisperer
      @critterwhisperer 5 ปีที่แล้ว +1

      That’s not a valve that turns on and off, it is what’s called a vacuum breaker. Without going into a long explanation, what it does is prevent the water from being sucked back out of the tank the wrong direction should a negative pressure happen somewhere in the water system. It’s a cross contamination prevention device and is required by code.

  • @twolfe4295
    @twolfe4295 2 ปีที่แล้ว +2

    The cold inlet is a dip tube. The hot outlet is the anode. Also, there may be an additional anode in the top.

  • @S_a_n22
    @S_a_n22 7 ปีที่แล้ว +1

    Nice and shinny tools...

  • @Mukundanghri
    @Mukundanghri 3 ปีที่แล้ว

    Thanks, brother!

  • @honestycounts9352
    @honestycounts9352 5 ปีที่แล้ว +3

    Most people never have any leaks with a SharkBite fitting at a hot water heater, but 1 out of 10 homeowners will experience a SharkBite failure at the water heater after only 10 years, and that leak will cause a lot of damage if there is not a floor drain nearby. If you are using a Sharkbite like that, then ALWAYS pressure-wrap the SharkBite fitting and the copper pipe itself with self-fusing silicone tape that is designed to seal pinhole leaks in pipes. That way 'WHEN' the o-rings on the SharkBite fails, the high-pressure wrapping of tape over the fitting will hold in the water and prevent any leaks. But you really have to pull HARD on that silicone tape when you are wrapping it around the pipe, you have to pull hard to create the pressure on the pipe and fitting from the tape that will be greater than the water pressure inside the pipe. It's a lot easier to simply use solder (or ProPress fittings if you've got the expensive tools already).

    • @rodgraff1782
      @rodgraff1782 2 ปีที่แล้ว +2

      Why is everyone so afraid of soft shouldering?

    • @mabahokano7567
      @mabahokano7567 4 หลายเดือนก่อน

      ​@@rodgraff1782most DIY folks use propane instead of MAP gas and this causes issues.

  • @dennisleblanc7933
    @dennisleblanc7933 2 ปีที่แล้ว +2

    A great video for DIYers. Personally I avoid sharkbites and thus learned how to sweat copper! Thanks for serving!

  • @suaibochosuta7595
    @suaibochosuta7595 6 ปีที่แล้ว +4

    I've used them with 100% success but I pay great attention to deburring and even sanding the fresh cut Copper's edge then I put a small amount of Dow Corning 111 silicone grease on my finger and reach up into the fitting and apply a small amount directly to the o ring.

  • @JRig2Stx
    @JRig2Stx 6 ปีที่แล้ว +10

    Do You Need To Sand The Pipes Before Using Shark Bite? And Don't You Use The Yellow Teflon Tape For Gas

    • @crand20033
      @crand20033 5 ปีที่แล้ว +9

      Use pipe dope.

  • @VideoNOLA
    @VideoNOLA 7 ปีที่แล้ว +12

    I think it should at least be mentioned that most local plumbing codes require at least 18" total pipe length between the water heater and plastic tubing like Pex (seen crimped onto copper assemblies just above unit). Something work taking into account when arbitrarily shortening those metal stubs! Sharkbite makes great flex connectors (with or without built-in ball valves) just for this purpose.

    • @eddiemata3now
      @eddiemata3now 5 ปีที่แล้ว +6

      Also, he used white tape on gas instead of the yellow tape..🤷‍♂️. Not sure if its code just here in texas but..

    • @brianbushay8283
      @brianbushay8283 2 ปีที่แล้ว

      18" above the top of the tank before transitioning to plastic as well as 6" from the flue pipe

  • @monmixer
    @monmixer 2 ปีที่แล้ว

    Great job. shark bites are wonderful and amazing.

  • @eirizarry2568
    @eirizarry2568 4 ปีที่แล้ว +5

    Great video.....excellent demonstration and explanation of each phase of the replacement. Thank you....this helped me immensely

  • @francomacedo2025
    @francomacedo2025 3 ปีที่แล้ว

    Very helpful thank you

  • @kwasihjohnson2667
    @kwasihjohnson2667 2 ปีที่แล้ว

    Please what is the size of the sharp bite ( cooper connector) .. thank you

    • @kwasihjohnson2667
      @kwasihjohnson2667 2 ปีที่แล้ว

      I meant shark-bites

    • @kwasihjohnson2667
      @kwasihjohnson2667 2 ปีที่แล้ว

      Also, I would like to mention that my water heater is a A. O Smith 74 gallons - would the installation be the same as the one presented in the video ? Thank for any hints

  • @im12runb4trouble
    @im12runb4trouble 5 ปีที่แล้ว

    I cant drain mine. I broke the little part that holds the valve handle off. Can that whole drain faucet be replaced? If not i'm looking at getting another hot water heater huh? Its only 3 to 4 years old but only been drained once.. Second time there was to much crap inside and i couldn't break it loose enough to drain faster then a dripping so didn't get much out after 3 hours and gave up. third time I broke handle and piece it attaches to off. So what happens now if I cant clean it out? water wont get hot? It does have a pressure relief valve up top to keep it from exploding on me and thats working good.Thanks

  • @danielvelezdiaz5851
    @danielvelezdiaz5851 4 ปีที่แล้ว +1

    Most of residential plumbing work,it just common sense!!! and new products are made with diy in mind.In the trades universe,you'll find everything!!! honest and dishonest,and this applies for everything in life.

  • @scottb_02
    @scottb_02 2 ปีที่แล้ว

    Is there an electrical hook up or is it battery? Not deburring the IDs or cleaning the ODs of the cut copper before shark bite install bugged me a little, but otherwise very good!

  • @wilowilo9462
    @wilowilo9462 2 ปีที่แล้ว

    Does someone knows where is the anode rod on that tank he is putting in I got the same tank

  • @gammatnt
    @gammatnt 3 ปีที่แล้ว

    nice video. I have a question . Is a 55 gallon water heater enough for 6 adults? or should i get a 75 gallon?

    • @gammatnt
      @gammatnt 3 ปีที่แล้ว

      i would recommend a 75 gallon

  • @theyenvy.shay_544
    @theyenvy.shay_544 5 ปีที่แล้ว +1

    I enjoyed watching this ...... thanks

  • @davidjeffreys9063
    @davidjeffreys9063 5 ปีที่แล้ว +3

    Hello. Now i have to do heating and plumbing work when the need arises and one of the small things you pick up over time, and is what i do as well is, as an example is to work on the 22mm copper first and then the smaller 15mm pipe second because it's easier to bend an alter 15mm pipe around a 22mm pipe rather than the other way round. The reason i say this is because this applies to the flue and the copper in this video. Firstly that flue doesn't look vertical and seems to be catching or being obstructed by the copper work. What would have been better is to get the flue vertical and right first and then do the copper work after using pulled bends and any soldered joints to work round the flue, although your point is not to solder, i think if you had used elbows, bends etc the pipework would look better.
    I say 22mm and 15mm as that's what we use in the UK but it might be half inch and three quarter where you are maybe

    • @normfromga
      @normfromga 2 ปีที่แล้ว

      Only where there are 30mm in an inch...🤔

  • @mdschererco
    @mdschererco 5 ปีที่แล้ว +1

    Thank you . Very helpful video.

  • @cliffperrino3015
    @cliffperrino3015 7 ปีที่แล้ว +1

    thanx for making the job doable

  • @CapitalWheeler
    @CapitalWheeler 5 ปีที่แล้ว +1

    New products sure make it easier

  • @karenfrye4546
    @karenfrye4546 6 ปีที่แล้ว +1

    Great info!

  • @nunyabidness2111
    @nunyabidness2111 5 ปีที่แล้ว +1

    Umm... Were you using *white* teflon tape for water pipes instead of the *yellow* teflon gas tape on the flexible gas lines?

  • @luisbernardez4853
    @luisbernardez4853 2 ปีที่แล้ว +1

    Excellent work buddy!!

  • @joesmith5302
    @joesmith5302 6 ปีที่แล้ว +23

    A lot of pros in these comments nit picking this guy. Could it be that the pros that charge $400 or $500 for this job don't want to be bypassed by the homeowners that are finding out that they can do it themselves?

    • @rayluna9860
      @rayluna9860 6 ปีที่แล้ว +5

      Following code and steps are a must. A Waterheater is a bomb if not plumbed properly.

    • @purplepill2024
      @purplepill2024 6 ปีที่แล้ว +1

      SharkBite fittings are a wonderful tool for a DIY or people who don't know how to solder. But, him not showing as the correct steps is a disservice. Need to clean the copper pipe, debur the copper, and use the SharkBite depth tool to see if you've pushed the fitting correctly. This half assed install can cause leaks and make people hesitate to use SharkBite.

    • @letzburn1779
      @letzburn1779 5 ปีที่แล้ว +1

      Joe, I would hope you hire this guy or take his advice so a simple water heater replacement costs you thousands in damage to your home. And really, telling the public that he can just check for leaks with his nose. THAT'S YOUR FAMILIES LIVES YOUR PUTTING IN THIS GUYS HANDS!!!

    • @purplepill2024
      @purplepill2024 5 ปีที่แล้ว +1

      @@rayluna9860 , water heater cannot bomb if not plumbed correctly. Water has nothing to do with explosions. Its the gas connection that needs to be leak-free.

    • @beanstyx2732
      @beanstyx2732 5 ปีที่แล้ว

      Yes sir they don’t want u to do it your self 👍

  • @brucecartwright4760
    @brucecartwright4760 6 ปีที่แล้ว +6

    I'm only going to get a couple of points because I could go on for a while he needs to learn the difference between a dip tube and a Anno rod you're supposed to have 18 inch of copper pipe between the top of the tank and the pex or cpvc pipe because you could melt the line you should never run a dryer line to a hot water tank and someone else mentioned details buring the pipe we definitely have to do that because there's a chance of the fitting shooting off the pipe thank you.

  • @cybco
    @cybco 5 ปีที่แล้ว +3

    Yes, a really good instructional guide. Very professional.

  • @kidalwys
    @kidalwys 6 ปีที่แล้ว +16

    This guy is going to kill someone not checking gas. Using Teflon tape on gas. The exhaust vent pipe looks like it was on half assed I have seen homeowner install better than that.

    • @crand20033
      @crand20033 5 ปีที่แล้ว +2

      He said he is experienced enough to know it won't leak.

    • @Whisgers
      @Whisgers 5 ปีที่แล้ว

      I thought the same no burner,soundness or flue analysis testing

    • @blueg3027
      @blueg3027 4 ปีที่แล้ว +1

      Lol there’s nothing wrong with Teflon on gas. Just don’t use it outside and make sure it’s certified for gas. Not sure why this dude used white though. I use both Teflon and dope and have never had a leak on either.

  • @kikibellebubba1248
    @kikibellebubba1248 7 ปีที่แล้ว +44

    The pipe was not properly deburred prior to installation.

  • @JosePadilla-yj1jm
    @JosePadilla-yj1jm 3 ปีที่แล้ว

    Good jod my fiend thank help me nise video

  • @lqdxoni1
    @lqdxoni1 5 ปีที่แล้ว +4

    2 pipe wenchs work better then 2 channel locks
    also is that always make sure you use gas rated Teflon tape gas rated or pipe dope.

  • @statenmh123
    @statenmh123 6 ปีที่แล้ว +1

    Thank you for your patience you made my job so much easier 😎

  • @dellex12
    @dellex12 9 หลายเดือนก่อน

    On the sharkbite website, it says these can be used with copper and the o ring can stay

  • @mtsflorida
    @mtsflorida 2 ปีที่แล้ว +3

    I didn't hear you say anything about burs that may be created when you cut the copper tubing lines. Some pipe cutters that cost over $40 may prevent burrs but the cheaper kind for $15 could be a problem so you need a de-burring tool or oval file and steel wool or round brush to smooth the cut pieces about a half inch inside and out especially around the cut to taper the end a little if not the bur will create a vortex that will erode about an inch from the connect to give you a pin hole leak over time.

  • @mikespain8655
    @mikespain8655 6 ปีที่แล้ว +1

    Really good informative video that sends the right stuff you need to know. When my 18 year old gas water heater takes a crap, I will go buy one and DIY.

  • @FPAZUSA
    @FPAZUSA 6 ปีที่แล้ว +1

    great tips.

  • @kim99may
    @kim99may 2 ปีที่แล้ว

    Date is good idea!

  • @thomastommy1192
    @thomastommy1192 5 ปีที่แล้ว +1

    Great video thanks for sharing. I live in an old Apartment house. Every few years the water heater goes up. The repairmen have started using the Shark links. I wanted to see how everything works. So if I ever needed to do this by myself. I could do it. The repairmen here tell me just enough to not know what I am doing one hundred percent. I will look forward to your new videos. I truly hope you have a blessed New Year.

  • @honolulu1476
    @honolulu1476 7 ปีที่แล้ว +1

    Very informative video. Thanks

    • @thomasquinn5481
      @thomasquinn5481 7 ปีที่แล้ว +1

      a real sloppy looking job, he said b vent, it wasn"t, flue pipe not cut square, thats why my cost is always more

    • @ICooke11
      @ICooke11 7 ปีที่แล้ว +1

      Thomas Quinn he called it B vent, when it is C vent, he called it a braided hose, and it's a corrugated stainless steel gas appliance connector, venting is a hack job....be careful who you let into your home to do work.

  • @NK-bc5xw
    @NK-bc5xw 5 ปีที่แล้ว +1

    Best video on TH-cam. Great job!

  • @gogaton
    @gogaton 7 ปีที่แล้ว +1

    Thanks, you make look so easy.

  • @Runfastgo
    @Runfastgo 5 ปีที่แล้ว

    Great vid

  • @Yophillips3272
    @Yophillips3272 5 ปีที่แล้ว +4

    The guy at home depot tried to sell me on the shark bites. I told him heck no. I already had sharkbites in my house 3 out of 4 were leaking. Soldering is actually super easy. Plus cheaper. And that little blue propane tank has lasted me 5yrs! I've used it for seized bolts, starting bonfires, and even powering a small grill when I ran out of propane. And it's still kicking.

  • @frankt2429
    @frankt2429 3 ปีที่แล้ว +1

    Why not Dielectric fittings for no corrosion??

    • @realexperiences8748
      @realexperiences8748 ปีที่แล้ว

      Pretty much all water heaters sold now come with dielectric nipples pre-installed. Whether or not they actually work well is a raging debate.