Ideal Logic L2 / F2 Fault Code | Gas Boiler Breakdown | How To Repair A Gas Boiler

แชร์
ฝัง

ความคิดเห็น • 89

  • @davegardner6253
    @davegardner6253 2 ปีที่แล้ว +9

    Allen, Your a god send mate, Been watching your videos for a few years and the amount of times you've helped is unbelievable. I've now moved house and have the ideal logic boiler and on filling, turned the wrong valve which stopped the flow to the rads. Couldn't understand why I couldn't get heating on lol. watched one of your videos and boom, saved another call out. Cheers mate, keep up the great work.

  • @wild_greebo
    @wild_greebo 2 ปีที่แล้ว +20

    Based on this video I poured a kettle of warm water over my consender pipe and reset my boiler and it fixed my L2 error code. Many thanks!

    • @KEC0001
      @KEC0001 2 ปีที่แล้ว +4

      Same, my condenser pipe leads outside so I had a feeling it might be frozen over. Had to get the ladder out as my boiler is upstairs but it's better than having to call the boiler man!

    • @Paola11852
      @Paola11852 ปีที่แล้ว +3

      Hi Allen OMG tried to reset boiler for central heating since yesterday, read your advice, also wild_greebo Thought this water pouring over the outside pipe is silly!!! Last tip to check and I’m amazed….lReally poured warm water from kettle, waited a few minutes and magic…low and behold it starting working……I’d never think of trying this…..absolutely freezing since yesterday now I can relax not havin to call out a repair guy..🤦‍♀️🤔which I can’t afford
      A massive thank you Allen for this video..👋🏻🫂😀👍

  • @royanderson2282
    @royanderson2282 ปีที่แล้ว +8

    Hi Allen. Thanks for the video mate. I'm not a plumber or gas engineer. I had a L2 fault on my Ideal logic combi es35. It turns out it was the condense, but not the pipe. The outside drain was blocked that the condense flows in to, not allowing the condense pipe to empty.
    Cheers mate, appreciate it.

  • @hellokhan2303
    @hellokhan2303 2 ปีที่แล้ว +6

    I’m currently 17 year’s old and doing my gas course at College this video really helped me out thanks you for the vid

    • @pauls826
      @pauls826 ปีที่แล้ว +1

      You have to be 18 to start doing your gas mate my sons just doing his

  • @sarahjanecollins8838
    @sarahjanecollins8838 29 วันที่ผ่านมา +1

    You are an angel! Thank you for your video. With your video I’ve managed to get our boiler to work as the outside pipe was frozen. Call out waiting time is 24hr and it’s currently -6 and I have a 3 yr old. Thank you so much ❤

  • @JavedsYT
    @JavedsYT 2 ปีที่แล้ว +2

    I’m still stuck but this video was very useful thank you. Having an L2/F2 fault, might be time to get a gas safe engineer in.

  • @GoldenGateNum9
    @GoldenGateNum9 ปีที่แล้ว +3

    1:38 You said it Allen 🤑🤑🤑, these bas*** are sucking us dry, thank you so much for your expertise it is much appreciated, I just wanted to ask 1 Q, when my pre paid meter money runs out I get cut off, my boiler shows the L2 due to no gas, what I wanted to know is can it damage my boiler having the sudden loss of gas in this way? It is an Ideal C30, thanks again ❤️‍🔥❤️‍🔥

  • @letsbye
    @letsbye 4 หลายเดือนก่อน +1

    2 year old boiler, started making a huge vibrating noise a week prior, but still worked. Eventually, it stopped this morning with a L2 code. temp doesn't go up more than 23, makes a gurgling noise on top. The gas engineer, listened to the symptoms and correctly guessed the patients name 'Ideal logic Combi'.

    • @lijosid
      @lijosid 4 หลายเดือนก่อน

      Have you fixed the problem? I have the same issue with same boiler

    • @letsbye
      @letsbye 4 หลายเดือนก่อน

      @@lijosid turns out it was a drain block. The boiler sends condensation water through a drain pipe, that sends out to drain. in our case is merged with the kitchen sink drain pipe. Not sure if it has a s trap to it. We cleaned the drain pipe as much as we can, that cleared the rumbling sound.
      It still has a noisy fan sound every time it turs the heat.

    • @solimankhan3291
      @solimankhan3291 หลายเดือนก่อน

      @@letsbyeinjector sounds like it needs cleaning

    • @givemeabreak8784
      @givemeabreak8784 หลายเดือนก่อน

      ​@@solimankhan3291Does have an injector?

  • @paulkennedy5953
    @paulkennedy5953 ปีที่แล้ว +1

    Very interesting Allen, just watching the video, just to know whats in there in the cabinet. Don't think I'll attempt it, not yet any way...👍

  • @trampham8603
    @trampham8603 ปีที่แล้ว

    Life saver! Thought I'd need to fork out a few hundred quid to call an engineer or replace the boiler but I just needed to top up the meter and restart. Thanks 👍

  • @DaveSimkiss
    @DaveSimkiss ปีที่แล้ว +2

    Great video, many thanks! I have an L2 warning and it’s not cold weather, in-fact it’s boiling out! So, this video confirmed what I suspected - that I’m not qualified to sort anything above unfreezing a frozen pipe!

    • @AllenHart999
      @AllenHart999  ปีที่แล้ว

      Thanks very much for your comment, please consider subscribing to support the channel 🙂

  • @davidmillar5067
    @davidmillar5067 ปีที่แล้ว +1

    Thankyou Alan got my boiler fixed today thanks for your advice

    • @AllenHart999
      @AllenHart999  ปีที่แล้ว +1

      Fantastic!

    • @AllenHart999
      @AllenHart999  ปีที่แล้ว +1

      Thanks very much for your comment, please consider subscribing to support the channel 🙂

  • @joetucker561
    @joetucker561 7 หลายเดือนก่อน +2

    Good video but the only issue is, how far do you go and how many parts do you replace before you get too deep in.. I’ve been to a 10 year old logic today with an L2, evidence of sump leaking and ideal said it “might” be the gas valve. I told customer it’s not been looked after or serviced and there’s no certainty I can get it working after changing 1 part.

  • @ItsAmberplays
    @ItsAmberplays 10 หลายเดือนก่อน +1

    Hi there
    I have ideal logic esp135 and i had gas engeneer to service it regularly but he couldn’t help me, my boiler make banging noise when start its very loud and few people was here to check it and every one said that is ok but every time its fire up is loud banging noise any advice?

  • @fabiochrist
    @fabiochrist 11 หลายเดือนก่อน +1

    So, ideal logic heat 12. Sudden f2, l2 only once popped up... engineer has changed gas valve, electrode and lead, cleaned condense container, checked gas pressure at the boiler and the meter, cleaned venturi and injector, condense pump works... water pressure topped up...f2 comes on around 5 minutes in operation. Any ideas?? Boiler is 12 years old but not used a lot (good epc?

  • @SuperBlackguard
    @SuperBlackguard 6 หลายเดือนก่อน

    Brilliant Video always informative and well summed up Cheers again Alan.

  • @kolamthuk5942
    @kolamthuk5942 2 ปีที่แล้ว +3

    Hi what I have to do when keep flashing PH

  • @asdreww
    @asdreww 2 หลายเดือนก่อน +1

    I have an interesting fault - repeated L2 fault when the boiler tries to reignite when it's warm, so if it's been on in say the last 20 minutes. If I leave it longer & reset boiler, it fires right up.

  • @steventhomas487
    @steventhomas487 2 ปีที่แล้ว

    Just poured water over our outlet pipe & hey presto l2 code gone & everything working again, thank you so much.

  • @atifdiyal
    @atifdiyal 2 หลายเดือนก่อน

    You are a soul saver. Thanks so much

  • @zooj4902
    @zooj4902 3 หลายเดือนก่อน

    I'm in an air bnb and it seems that the L2 error code is there. Question is, is it ok to just leave it until the air bnb host sorts it or should I turn something off?

  • @cyricstruth
    @cyricstruth ปีที่แล้ว

    My hero

  • @francescamiddleton9644
    @francescamiddleton9644 2 ปีที่แล้ว +1

    Thank you Allen! You're a lifesaver 😊

  • @ausrajank4552
    @ausrajank4552 ปีที่แล้ว

    Thank you so much I wake up this morning and my boiler not working showing L2. Helps hot water and it's working again 😊

  • @stevenbateman9597
    @stevenbateman9597 10 หลายเดือนก่อน

    Hi Alan I have a 10 year old ideal logic. It hasn't. Been used for 6 months. It was working fine before, now every time the heating tries to come on the boiler fires then cuts out and the f2 fault code comes up. But the hot water side works fine every time I checked the water pressure just over 1 bar the gas supply should be ok as the hw side is OK we had it serviced about 1 Yr ago. Any ideals thanks

  • @pauls826
    @pauls826 ปีที่แล้ว

    What was the Worcester tip Allan I’m dying to know 😂😂

  • @romeogauthier9637
    @romeogauthier9637 2 ปีที่แล้ว

    My vismannm 100 goes to F2 time to time! I have lesson and watch your video! I have check all the possibles and all is good! so now what do I have to check?

  • @marisataylor2408
    @marisataylor2408 6 หลายเดือนก่อน

    Thanks, L2 fault was ok after I reset 😊

  • @descamm9313
    @descamm9313 2 ปีที่แล้ว

    Top man, cheers Allen, very useful video again.. 👍🏻

  • @jane-iu2by
    @jane-iu2by 2 ปีที่แล้ว

    Thanks I have a pre payment meter and i was able to rest the gas easily after topping it up

  • @gerardodoherty7625
    @gerardodoherty7625 2 ปีที่แล้ว +1

    How would you locate your condenser pipe?

  • @mariehaikal3048
    @mariehaikal3048 ปีที่แล้ว

    thank you, you helped me solve my problem.

  • @bizanskentsoylusu354
    @bizanskentsoylusu354 2 ปีที่แล้ว

    Adam anlatıyor, sanki boiler ustasıyız 😂😂

  • @Raj-ul9my
    @Raj-ul9my ปีที่แล้ว

    Which fluke do you use for fault finding on gas boilersv

  • @dave83x
    @dave83x ปีที่แล้ว +1

    hi great vids. can you please drop a recommended gas course web link, many thanks

  • @maudya555
    @maudya555 4 หลายเดือนก่อน

    Thank you so much, you are STAR!

  • @samanthahollingsworth7189
    @samanthahollingsworth7189 ปีที่แล้ว

    @samanthahollingsworth7189
    0 seconds ago
    I have a logic combo boiler c24 and it’s on an L2 fault, I had no gas but it’s now been delivered but it’s still not working, I reset it and checked the pipe isn’t frozen but I don’t know what else to do! Help! Please!

  • @munnstar12
    @munnstar12 2 ปีที่แล้ว

    @Allen and all gas knowledge folks here, I have an ideal logic c30 base model. I notice that the main selected knob for CH on the boiler itself only shows a digital range from 30 to 35 degrees C when the spec sheet shows it being min 30 C max 80 C .The DHW is fine and shows min 40 C and max 65 C, which matches spec sheet. (More warmth rubbing hands together than the rads) Have you ever encountered something similar.

    • @davidhowell2269
      @davidhowell2269 ปีที่แล้ว

      Sounds as if the control knob shaft is not correctly positioned into the control potentiometer on the control board. I expect you have had this fixed by now.

  • @christophersherratt7299
    @christophersherratt7299 2 ปีที่แล้ว

    Allen are you from the North West I would love to have a look at my boiler it's crap in the system it's only 6year old viessmann and for you to service the boiler every year

  • @AcousticNRG
    @AcousticNRG 4 หลายเดือนก่อน

    Had no hot water or heating today cleaned out the condenser container fired straight up n1 ;D

  • @MrMarkski
    @MrMarkski 2 ปีที่แล้ว

    Hi Allen when i call for hot water the boiler makes a boom sound, but only twice then fine can you help

  • @rootyroot
    @rootyroot ปีที่แล้ว

    I keep getting the F2 and L2 one after another, after resetting one or twice it comes back on (the boiler has been doing it for nearly a year). Just ordered the hive rad valves so need the faults fixed so it doesn't keep tripping once the flame goes out.
    Just ordered a Flame sensor and Ignition electrode hoping it's one of them.

    • @rootyroot
      @rootyroot ปีที่แล้ว

      @MrMaxFreeze I changed both mate, and it worked only cost £25

    • @rootyroot
      @rootyroot ปีที่แล้ว

      @MrMaxFreeze mine sparks straight away but it has a bit of a delay on the spark, and sometimes makes a loud bang when it sparks for some reason, so I'm tempted to change mine

  • @mrseb99
    @mrseb99 2 ปีที่แล้ว

    Could you do a video on those cards? I’m interested on how to use them

  • @kevincranfield5235
    @kevincranfield5235 2 ปีที่แล้ว +2

    Well explained 👍

    • @AllenHart999
      @AllenHart999  2 ปีที่แล้ว

      Thank you sir.

    • @AllenHart999
      @AllenHart999  2 ปีที่แล้ว

      I have this setup and also a WB4000 if you ever fancy a trip to Leeds

    • @kevincranfield5235
      @kevincranfield5235 2 ปีที่แล้ว

      Is the 4000 functioning?

    • @AllenHart999
      @AllenHart999  2 ปีที่แล้ว

      @@kevincranfield5235 it’s not but I could connect it in

  • @davebirmingham3415
    @davebirmingham3415 2 ปีที่แล้ว +1

    Hi Alan great videos and really helpful tips and tricks .I'm a gas installer in Dublin and I've noticed since September last year the two buttons on the front of panel one being the restart button normally I use them to go into low/high fire mode and change pump to p1 .Now I've got three boilers from three different suppliers and each time I get the same result it's like as if the buttons aren't lining up but have no joy at I've been in touch with ideal UK but no one knows . Would appreciate your help if you could help me many thanks again Dave

  • @abdullahal-saadi6455
    @abdullahal-saadi6455 2 ปีที่แล้ว

    Thank you very much, well explained

  • @khurramiftakhar2226
    @khurramiftakhar2226 2 ปีที่แล้ว

    Hello, I am new in this field and want to buy multimeter. Is Fluke multimeter 115 is good enough for gas trade. Thanks

  • @SURAH267
    @SURAH267 2 ปีที่แล้ว

    I have hot water , but no heat , pressure is correct , what can be wrong

  • @SuperMoscow111
    @SuperMoscow111 2 หลายเดือนก่อน +1

    Fault. 05?

  • @xinshi2517
    @xinshi2517 หลายเดือนก่อน

    what that e on the temp

  • @valericacimpeanu1800
    @valericacimpeanu1800 ปีที่แล้ว

    I have 1 boiler i mini from ideal , i have 1 strange sound i have 2 specialist in 2 days and same problem i have 1 strange sound and 1 sound like 1 car when he want to start and f2

  • @zinashalemayhu5961
    @zinashalemayhu5961 หลายเดือนก่อน

    Thanks

  • @rorytinsley
    @rorytinsley ปีที่แล้ว

    I have a ideal that goes to F2 when fan speed drops. Could anyone give me some help

  • @JME_C
    @JME_C ปีที่แล้ว +1

    Did exactly as suggested and absolutely nothing happens

  • @paulbird5851
    @paulbird5851 3 หลายเดือนก่อน

    Thanks for telling us you got the Ideal card on the training course then digressing and not telling us what the card does haha - must do better Allen ha

  • @frazzzz1066
    @frazzzz1066 2 ปีที่แล้ว +2

    Ideal the boiler with more faults than I’ve ever seen they really are crap

  • @patrikpokuta650
    @patrikpokuta650 ปีที่แล้ว +1

    Hello my boiler is allways showing f2

    • @AllenHart999
      @AllenHart999  ปีที่แล้ว +1

      I suggest you call someone out to check it. Thanks.

  • @bigcahoonaburger8550
    @bigcahoonaburger8550 2 ปีที่แล้ว +1

    These are a poor boiler. Simple in design and to fix. Im binning mine as the board went, heat exchanger, ignition, pressure switch, make sure the diverter cartridge doesn’t stick by cleaning it, pre heat option a waste of time being on it, hot water is rubbish it cannot keep up with water flow to heat it quick enough… had trouble since year 7 of it life and limped on until 10.
    Only bit I never touched was gas side, the rest any clown can do as long as you are methodical. Board is plug n play! £70 don’t fall for £250! pressure switch pulls out just make sure depressurise the system, oh n pay £350 for one off payment direct to ideal repair if it’s a major job over that price, it’s a one off fee, not a repair contract though.

  • @jamesmincher3435
    @jamesmincher3435 ปีที่แล้ว +1

    Just realise it weren’t my boiler I had to open valve back up by pressing A/B on gas meter silly me forgot you had to do that when you run out of gas credit stupid me lol

  • @ajkarpov4608
    @ajkarpov4608 ปีที่แล้ว +1

    Where's the label saying "INCLUDES PAID PROMOTION"?

  • @deano-qj9tj
    @deano-qj9tj 2 ปีที่แล้ว

    What does the card do? You never said 😊

  • @ashleyunderwod5877
    @ashleyunderwod5877 8 หลายเดือนก่อน

    Very poor, didn't learn anything I know . But he seems a nice bloke . Give up the utube kid

    • @AllenHart999
      @AllenHart999  8 หลายเดือนก่อน +1

      My channel raises about £30k a year for children with cancer so I think I will continue

  • @giuseppetrento1229
    @giuseppetrento1229 2 ปีที่แล้ว

    Amaxin better impossible