Growatt SPF 3500-5000 ES Off-grid Inverter Installation Introduction

แชร์
ฝัง

ความคิดเห็น • 140

  • @joseseelen
    @joseseelen 6 หลายเดือนก่อน +1

    I have a Growatt SPF 3500 ES off grid inverter. I'm very sad to say it is not a good experience! The first one I got installed on April first (no joke) 2022. It stopped working, January 2023. I live off grid in Portugal and after 4 months without electricity or running water, I finally received a new one. A friend (solar ingenier) installed it and "looks after" it. Now since last week without a clue, the inverter broke down again! So here I am, again with no electricity or running water. I send e-mails, called and try to contact them to solve this predicament! Hopefully this helps to get the ball rolling to get me out of this awful situation and into power!

  • @mbafamily193
    @mbafamily193 3 ปีที่แล้ว +2

    EXCELENTE INVERSOR

  • @restfulplace3273
    @restfulplace3273 3 หลายเดือนก่อน

    @7:00. Solar only mode.
    If you want to setup an ev charger, how do I setup ev charger to talk to inverter and only draw what the solar can provide?
    Which ev chargers are suitable?

  • @zoran3180
    @zoran3180 8 หลายเดือนก่อน

    Hello i have only two 12.8 V Batteries at the Moment.
    Can i use this iverter or need at least 40v Batteries?

  • @abambac
    @abambac 2 ปีที่แล้ว +1

    A question about connecting 2 strings.
    It’s marked as max 18A. How strict is that?
    I was thinking to connect two strings with panels specified 11,2 isc/A 10,58 imp/A.

    • @Growatt
      @Growatt  2 ปีที่แล้ว

      Hello, for technical support, please contact our service team at service@ginverter.com, or you can call our service hotline at +86 755 2747 1942. Thank you!

  • @godblessthelessfortunate3175
    @godblessthelessfortunate3175 3 ปีที่แล้ว

    Are you working on a new model or have one already for N. America to include 120VAC input and 120/240VAC output with the other specs pretty similar? I like the 5KW inverter and 450VDC solar input specs but the lack of 120VAC on both the input and outputs is a deal breaker.

    • @Growatt
      @Growatt  3 ปีที่แล้ว

      Hello, for more product offerings in the US, please visit our US website at www.growatt-america.com/list-42.html#product42. Thank you!

    • @Lawiah0
      @Lawiah0 3 ปีที่แล้ว +1

      @@Growatt
      use transformer to split the 240V into 120V
      th-cam.com/video/NzrYyDEbaHY/w-d-xo.html

  • @Xxxcappie23
    @Xxxcappie23 3 ปีที่แล้ว

    Quick observation, i noticed there is only one PV input, should there not be a positive and a negative input from the pv panels?

    • @Growatt
      @Growatt  3 ปีที่แล้ว

      Hello, there's positive and negative input to the inverter. If you have more product inquiries, please feel free to contact our sales team at info@ginverter.com. Our team can provide assistance for you. Thank you!

  • @seanmoon1444
    @seanmoon1444 3 ปีที่แล้ว

    SPF-3000 TL LVM-24P do you have a video for this model? having trouble monitoring my battery capacity is it just the battery icon with the 4 bars?

    • @Growatt
      @Growatt  3 ปีที่แล้ว

      Hello, you can check out the product user manual at our website: www.ginverter.com/Off-Grid-Storage-Inverters/44-589.html. If you need further technical support, please feel free to contact our service team at service@ginverter.com. Our team can provide assistance for you. Thank you!

  • @HoshMultinational
    @HoshMultinational 5 หลายเดือนก่อน

    Can i use a tubular battery on your product ?

  • @markrocketmangrimstead
    @markrocketmangrimstead ปีที่แล้ว

    Hi i have just purchased a spf 3500es,i dont want to connect batteries at the moment, can you explain how i can program the inverter for without battery mode as i am not connecting batteries.
    Also tge display is showing my panels at 179volts i have run the panels in series but the inverter is not showing wattage

    • @margarita8442
      @margarita8442 ปีที่แล้ว +1

      it shows KV on the left bottom screen , which is same as watts

  • @damueller
    @damueller 2 ปีที่แล้ว

    Does this inverter have Rcmu protection installed, or do you also need an FI Type B?

    • @Growatt
      @Growatt  2 ปีที่แล้ว

      Hello, for technical support, please contact our service team at service@ginverter.com, or you can call our service hotline at +86 755 2747 1942. Thank you!

  • @VeraVeraniego
    @VeraVeraniego 2 ปีที่แล้ว +1

    Is this inverter appropiate for on grid photovolataic systems?

    • @Growatt
      @Growatt  2 ปีที่แล้ว

      it is only for off-grid PV solutions

  • @alex06059
    @alex06059 4 หลายเดือนก่อน

    Hello! Can it be tied to both panels and mains? In case the plans do not produce enough to take the difference from the network?

  • @orosupplycontact3332
    @orosupplycontact3332 3 ปีที่แล้ว +1

    could we use it to correct grid voltage drop issues ?

    • @Growatt
      @Growatt  3 ปีที่แล้ว +2

      Hello, this off-grid inverter can not be used to correct voltage drop of the grid. It's can be used for backup power and energy storage. You can visit our website at www.ginverter.com/Off-Grid-Storage-Inverters/44-625.html or contact our sales team at info@ginverter.com for more product info. Thank you!

  • @Blobs10
    @Blobs10 2 ปีที่แล้ว

    When using the inverter without battery, and supposing load is 1000w and PV production is 500w, will it switch to grid and grab all the load? or will it use 500 from PV and 500 from grid?

    • @Growatt
      @Growatt  2 ปีที่แล้ว +2

      it use 500 from PV and 500 from grid

    • @Blobs10
      @Blobs10 2 ปีที่แล้ว

      @@Growatt nice. Thanks 👍

  • @rromero2924
    @rromero2924 3 ปีที่แล้ว +1

    Can these inverters work with non lithium batteries. Such as lead acid or nickel iron?

    • @Growatt
      @Growatt  3 ปีที่แล้ว

      Yes, it can work with common batteries in the market. If you have further product inquiries, please feel free to contact our sales team at info@ginverter.com. Thank you!

    • @user-rx6th2hj5z
      @user-rx6th2hj5z ปีที่แล้ว

      @@Growatt i have your inverter and i have by one wulills lifepo4 48v 120ah battery can you help me to connect the battery with your inverter, i can give you my email if you want

  • @Bulgabb
    @Bulgabb 2 ปีที่แล้ว

    Hello, how to connect to Felicity Solar battery BMS?

  • @hildanioviana
    @hildanioviana ปีที่แล้ว

    fiquei interessado nesse de 5000 mas minha rede de energia e 127v! tem previsão de lançar 127v?

    • @Growatt
      @Growatt  ปีที่แล้ว

      Olá, você pode conferir nosso inversor off-grid SPF 3000TL LVM-ES: www.ginverter.com/Off-Grid-Storage-Inverters/44-639.html
      Para mais perguntas sobre produtos, sinta-se à vontade para entrar em contato com nossa equipe de vendas em info@ginverter.com. Obrigada!

  • @venceslaubr
    @venceslaubr 3 ปีที่แล้ว +1

    Here where I live, we have 220 V phases, two 110 V phases. Is it possible to install this inverter?

    • @Growatt
      @Growatt  3 ปีที่แล้ว

      Hello, for technical support, please feel free to contact our service team at service@ginverter.com. Thank you!

    • @jimmyjackson9090HVAC
      @jimmyjackson9090HVAC 3 ปีที่แล้ว

      yes with the 3000watt unit

    • @Nobody_Famous
      @Nobody_Famous 3 ปีที่แล้ว

      th-cam.com/video/NzrYyDEbaHY/w-d-xo.html

  • @chuxxsss
    @chuxxsss 2 ปีที่แล้ว

    Why does you system not turn on with batteries connected or solar. Only works with grid connect to turn on display? Why with it no supply AC to load or use batteries for load?

    • @Growatt
      @Growatt  2 ปีที่แล้ว

      Hello, for technical support, please contact our service team at service@ginverter.com, or you can call our service hotline at +86 755 2747 1942. Thank you!

  • @wongsabarchannel1335
    @wongsabarchannel1335 3 ปีที่แล้ว

    Hi.. For Growatt Grid Tie In Inverter, Can you explain when in the sunny that condition PV is producing Electricity Power, then when Grid is shut down, Is there any internal sensor in Growatt inverter to shutdown the Inverter? Or Inverter will cut circuit to Grid Connection only, mean while inverter work as Off Grid Inverter.. so PV can still supply energy to the loads at Home?
    Thank you for your answer..

    • @Growatt
      @Growatt  3 ปีที่แล้ว

      Hello, for technical support, please feel free to contact our service team at service@ginverter.com. Thank you!

  • @thingswithlloyd4581
    @thingswithlloyd4581 ปีที่แล้ว

    Can the 5000 ES only be connected to a 48V LifePO4 battery or can it be connected to 12v/24v also

    • @semelgarejo
      @semelgarejo ปีที่แล้ว +1

      the SPF5000ES will be conected to 48Vcc.

  • @louisdiedricks7110
    @louisdiedricks7110 3 ปีที่แล้ว +2

    My rooftop solar array with microinverters produces 240VAC. Can I use my 240VAC solar output to the Growatt AC input?

    • @Growatt
      @Growatt  3 ปีที่แล้ว

      Hello, for technical support and customer service, please feel free to contact our service team at service@ginverter.com. Thank you!

  • @gxmario_13jf94
    @gxmario_13jf94 2 ปีที่แล้ว

    hello sorry if I disturb you or just installed my growatt 5000es or connected the lithium battery 48 volt 100ah with voltage 52.5 volts or tried to turn on and it did not turn on you can help me please thank you.Then or connected the 230volt network and it turned on but at the output it did not give me the 230volt to power the loads, and despite the battery is connected as soon as I remove the 230volt utility

    • @Growatt
      @Growatt  2 ปีที่แล้ว

      Hello, for technical support, please contact our service team at service@ginverter.com, or you can call our service hotline at +86 755 2747 1942. Thank you!

  • @etiaztan
    @etiaztan ปีที่แล้ว

    Hello, i want to ask about 3 phase system using 5000 ES, is that possible using 2 inverters in 1st phase, and 1 inverter in others phase?

  • @horiinthephilippines6760
    @horiinthephilippines6760 2 ปีที่แล้ว

    Hello I have a Growatt 3500ES. I have not connected it to a battery. I have "19" and Flashing red triangle in the bottom right hand corner of the display... What does this mean?
    In "program mode 1" I have it set to SUB

    • @Growatt
      @Growatt  2 ปีที่แล้ว

      Hello, for technical support, please contact our service team at service@ginverter.com, or you can call our service hotline at +86 755 2747 1942. Thank you!

  • @davidskelton1559
    @davidskelton1559 3 ปีที่แล้ว

    Hi, Is this inverter available from Growatt in Australia?

    • @Growatt
      @Growatt  3 ปีที่แล้ว

      Hello, this inverter is being offered in Australia. You can check out more about the product at our Australian website: www.ginverter.com.au/Off-Grid-Storage-Inverters-44-632.html. For further product infor and assistance, please feel free to contact our Australian service team at 1800 476 928/australia@ginverter.com. Thank you!

  • @ismailkarolia284
    @ismailkarolia284 2 ปีที่แล้ว

    I am using the 5000 ES. Solar energy is being generated, however the dashboard is showing 0 kwH for . I am using the inverter without batteries. Is there setting or configuration I am missing. please assist.

    • @Growatt
      @Growatt  2 ปีที่แล้ว +1

      Hello, for technical support, please contact our service team at service@ginverter.com, or you can call our service hotline at +86 755 2747 1942. Thank you!

  • @dibeerwolf1645
    @dibeerwolf1645 ปีที่แล้ว

    ask yourself: if the SPF5000es is connected via AC output and via AC input and the following conditions apply: all consumers are off, the battery is already 100% charged, i.e. fully charged, and there is full sun on the PV modules at 12:00 p.m.: what happens to the EXCESS electricity from the PV system then ? (does it flow back into the public grid via AC output or AC input?) thank you

  • @alaahussein7305
    @alaahussein7305 3 ปีที่แล้ว

    Hi I just buy new spf 5000es which android appe is convenient with this inverter?

    • @Growatt
      @Growatt  3 ปีที่แล้ว

      Hello, our monitoring APP is ShinePhone. If you need further assistance, please feel free to contact our service team at service@ginverter.com. Thank you!

  • @malikhassan5002
    @malikhassan5002 2 ปีที่แล้ว

    Hi . how can switch of the green flesher in the wi fi / gprs card because I dont need to use the wi fi / gprs

    • @Growatt
      @Growatt  2 ปีที่แล้ว

      Hello, for technical support, please contact our service team at service@ginverter.com, or you can call our service hotline at +86 755 2747 1942. Thank you!

  • @dinoonsoe8003
    @dinoonsoe8003 3 ปีที่แล้ว

    good afternoon, do you perhaps also have had error code 122 on Growatt spf5000 , bus voltage too high and know how solved it?

    • @Growatt
      @Growatt  3 ปีที่แล้ว

      Hello, for technical support and customer service, please feel free to contact our service team at service@ginverter.com. Thank you!

    • @SkyMobi
      @SkyMobi 3 ปีที่แล้ว

      First of all, get the right model number, this video is about the SPF5000ES

  • @markuss.7615
    @markuss.7615 3 ปีที่แล้ว

    Hallo, is this a new hybridinverter?

    • @Growatt
      @Growatt  3 ปีที่แล้ว +1

      Hi, it's a new off-grid inverter. You can check out more about the inverter at our website: www.ginverter.com/Off-Grid-Storage-Inverters/44-625.html. If you need further product inquiries, please feel free to contact our sales team at info@ginverter.com. Thank you!

  • @alicethun1655
    @alicethun1655 2 ปีที่แล้ว +2

    Can I use this to power 3 phase 400v

    • @Growatt
      @Growatt  2 ปีที่แล้ว +1

      Yes, you can also check out more about the product on our website: www.ginverter.com/Off-Grid-Storage-Inverters/44-625.html

  • @salarhadi2988
    @salarhadi2988 3 ปีที่แล้ว

    Can shareing sun power energy with grid to home load?

    • @Growatt
      @Growatt  3 ปีที่แล้ว

      Hello, for technical support and customer service, please feel free to contact our service team at service@ginverter.com. Thank you!

  • @ZangetsMugetsu
    @ZangetsMugetsu 2 ปีที่แล้ว

    Hi there, is this pure sine wave low frequency? Can you direct me to a sale person? I'd like to buy in bulk. Regards.

    • @Growatt
      @Growatt  2 ปีที่แล้ว

      Hello, for product inquiries and business collaboration, please feel free to contact our sales team at info@ginverter.com. Thank you!

    • @rossawood5075
      @rossawood5075 2 ปีที่แล้ว

      I belive thes are high frquency Mosfet type, not transformer type low frequency units as with Palstar or AIMS type inverters.

  • @christoperdeypalubos2302
    @christoperdeypalubos2302 2 ปีที่แล้ว

    why pv input port here is 8awg, in the manual is 12awg for the 5000ES model

    • @Growatt
      @Growatt  2 ปีที่แล้ว

      Hello, for technical support, please contact our service team at service@ginverter.com. Thank you!

  • @jazzcam2799
    @jazzcam2799 ปีที่แล้ว +2

    Can I export to the grid with this model

  • @PyjamasBeforeChrist
    @PyjamasBeforeChrist 3 ปีที่แล้ว

    Will this inverter feed the grid after the battery is full?

    • @Growatt
      @Growatt  3 ปีที่แล้ว +1

      Hello, SPF 3500-5000ES is an off-grid inverter. It can not feed power into the grid after the battery is fully charged. If you have further product inquiries, please feel free to contact our sales team at info@ginverter.com. Thank you!

    • @PyjamasBeforeChrist
      @PyjamasBeforeChrist 3 ปีที่แล้ว

      @@Growatt cheers. Is there a similar inverter that can as well?

    • @Growatt
      @Growatt  3 ปีที่แล้ว

      @@PyjamasBeforeChrist Hello, you can check out our storage hybrid inverters here: www.ginverter.com/Residential-Storage-Inverters.html#product43. There're a variety of product offerings available to meet your demand. For further product pricing and inquiries, you can contact our sales team at info@ginverter.com. Thank you!

  • @mohammadfarshoukh
    @mohammadfarshoukh 2 ปีที่แล้ว

    Can i switch on and off the different outputs via wifi (App)?

  • @micheleliaaoun
    @micheleliaaoun 2 ปีที่แล้ว

    Facing problem connecting my Felicity lithium battery through BMS, any solution ?

    • @Growatt
      @Growatt  2 ปีที่แล้ว

      Hello, for technical support, please contact our service team at service@ginverter.com, or you can call our service hotline at +86 755 2747 1942. Thank you!

  • @tiaan1587
    @tiaan1587 3 ปีที่แล้ว

    I want to use can bus,what cable can i use between inverter and battery and between two batteries,the battery is lithium

    • @Growatt
      @Growatt  3 ปีที่แล้ว +1

      Hello, for technical support, please feel free to contact our service team at service@ginverter.com. Thank you!

    • @tiaan1587
      @tiaan1587 3 ปีที่แล้ว

      @@Growatt thank you

  • @thirskel
    @thirskel 3 ปีที่แล้ว

    How do I operate with two units at the same phase?

    • @Growatt
      @Growatt  3 ปีที่แล้ว

      Hello, for product inquiries, please contact our sales team at info@ginverter.com. Our representative can provide assistance for you. Thank you!

    • @SkyMobi
      @SkyMobi 3 ปีที่แล้ว

      It is in the manual how to link the 2 units

  • @jeffreyumeh8580
    @jeffreyumeh8580 7 หลายเดือนก่อน

    I would like to go for the 3500W version of this inverter, but the MPPT startup voltage is TOO DAMN HIGH!!! Yeh you have a 3000W inverter that has a 60V MPPT startup voltage, and another 3600W inverter that has a 70V startup or something like that, but the frist is 3000W and I really would like that extra 500 - 600W and the second only works with your own brand batteries, which sorry but I am not gonna get locked into your ecosystem.
    For a proprotary battery to be fair it's competitively priced with server rack batteries and if I was just going to set and forget I would probably go with you guys, but I eventually want to move to a victron 5kVA inverter, although the main reason I want to go victron is for the low self consumption, the data sheet does say "Self-Consumption night:

  • @dsuse3949
    @dsuse3949 ปีที่แล้ว

    I do not want ac input
    I only want ac output to consumer box
    Do I need to disable Ground earth bonding?????? And use an earth rod ???

    • @Growatt
      @Growatt  ปีที่แล้ว

      Hello, for technical support, please contact our service team at service@ginverter.com, or you can call our service hotline at +86 755 2747 1942. Thank you!

  • @musakhan174
    @musakhan174 ปีที่แล้ว

    Hello i have a new growatt 5000 es it drains batteries to fast i have 4 12v 200a batteries with only 2 fans on at night plz answer

    • @Growatt
      @Growatt  ปีที่แล้ว

      Hello, for technical support, please contact our service team at service@ginverter.com, or you can call our service hotline at +86 755 2747 1942. Thank you!

    • @thingswithlloyd4581
      @thingswithlloyd4581 ปีที่แล้ว

      How are your batteries wired, parallel?

  • @Fritsvrolijk
    @Fritsvrolijk ปีที่แล้ว

    Hello if you have a 10 kw inverter can you make it by software a 8 kw inverter ????

    • @Growatt
      @Growatt  ปีที่แล้ว

      Hello, for technical support, please feel free to contact our service team at service@ginverter.com. More contact info can be founded on our website here: www.ginverter.com/support/contact. Thank you!

  • @micheleliaaoun
    @micheleliaaoun 2 ปีที่แล้ว

    Where to check lithium battery compatibility list and communication protocol?

    • @Growatt
      @Growatt  2 ปีที่แล้ว

      Hello, for technical support, please contact our service team at service@ginverter.com, or you can call our service hotline at +86 755 2747 1942. Thank you!

  • @bennibenni1700
    @bennibenni1700 2 ปีที่แล้ว

    Hello waht is the maximal Ac output with the Bypass

    • @Growatt
      @Growatt  2 ปีที่แล้ว

      Hello, for technical support, please contact our service team at service@ginverter.com, or you can call our service hotline at +86 755 2747 1942. Thank you!

  • @wtrey333
    @wtrey333 3 ปีที่แล้ว

    with the ES 5000, am i able to Charge my 48v Li battery with my Generator when I plug in my generator to the AC Input????

    • @Growatt
      @Growatt  3 ปีที่แล้ว

      Hello, for product inquiries, please contact our sales team at info@ginverter.com. Our representative can provide assistance for you. Thank you!

    • @SkyMobi
      @SkyMobi 3 ปีที่แล้ว +1

      Yes

  • @Z-add
    @Z-add 2 ปีที่แล้ว

    only has one AC output. Their should be a backup only AC outlet.

  • @acephyo7222
    @acephyo7222 2 ปีที่แล้ว

    Can Growatt SPF5000TL HVM work without battery?

    • @Growatt
      @Growatt  2 ปีที่แล้ว

      No it needs to be connected with batteries to work

    • @acephyo7222
      @acephyo7222 2 ปีที่แล้ว

      Whats the difference between growatt SPF5000TL HVM vs SPF5000ES ?

    • @Growatt
      @Growatt  2 ปีที่แล้ว

      www.ginverter.com/ hello, please find the info you want on our website

  • @loveworldnationcyber9695
    @loveworldnationcyber9695 3 ปีที่แล้ว

    Good afternoon do you have dealerships in Nairobi Kenya where one can buy?

    • @Growatt
      @Growatt  3 ปีที่แล้ว

      Hello, for product inquiries and business collaboration, please feel free to contact our sales team at info@ginverter.com. Thank you!

  • @DoDoBedStory
    @DoDoBedStory ปีที่แล้ว

    how to install 2 5000 es with 3 51.2v 200ah batteries

    • @Growatt
      @Growatt  ปีที่แล้ว

      Hi, for technical support, please contact our service team at service@ginverter.com or call our service hotline at +86 755 2747 1942. Thank you!

  • @andrewkingsley7221
    @andrewkingsley7221 3 ปีที่แล้ว +3

    Morning there. These unit have to many faults and there is very little support on them here is South Africa. They restart when they want and flash the output power 4 or 5 times a day or night. There is no support on them I will stay with a known brand here in the country. very dispondant about the Growatt 5000. not a happy chappy me.

    • @Growatt
      @Growatt  3 ปีที่แล้ว

      Hello, for technical support and customer service, please feel free to contact our service team at service@ginverter.com. Thank you!

    • @ckp3118
      @ckp3118 3 ปีที่แล้ว

      Agree. Received my 3rd Growatt inverter today. Trying a High Voltage inverter.
      Inverters did not switch to solar automatically in the morning and at 10h05 it gives "Bus Voltage High" and trips all power. If you are not at home or on holiday your house has no power at all.

    • @Growatt
      @Growatt  3 ปีที่แล้ว +1

      @@ckp3118 Hello, for technical support and customer service, please feel free to contact our service team at service@ginverter.com. Thank you!

    • @SkyMobi
      @SkyMobi 3 ปีที่แล้ว

      I dont understand the problem? why would they restart if not overloaded "flash the output power "?

    • @SkyMobi
      @SkyMobi 3 ปีที่แล้ว

      @@ckp3118 Are you saying it stays on grid power and not using solar? Also what is your solar array voltage?

  • @easylooker
    @easylooker 3 ปีที่แล้ว +1

    Beware north american buyers. If you see at 4:45 mark this unit is a N/G/Hot.
    On my Chinese unit from a different company it is the same thing and I can't make it work because I need 120v/N/120v to make 240v. They sent me a unit that has 1 leg of 240v like European style. Bought 5 of the 5.5kw and can't use em. I don't know why its beyond the level of understanding to the Chinese that we need 120/N/120 to get 240v.

    • @Growatt
      @Growatt  3 ปีที่แล้ว

      Hello, you can seek technical support from our service team at service@ginverter.com and check what can be done to solve the issue. Thank you!

  • @Drakkan-pn5lh
    @Drakkan-pn5lh ปีที่แล้ว

    ich verstehe kein Wort. Gibt es das Video auch in deutsch?

  • @toninobeltrante211
    @toninobeltrante211 หลายเดือนก่อน

    Buongiorno esiste un video o un pdf in italiano

  • @TheFillmoremauro
    @TheFillmoremauro 3 ปีที่แล้ว

    firmware update??? where??

    • @Growatt
      @Growatt  3 ปีที่แล้ว

      Hello, for technical support, please feel free to contact our service team at service@ginverter.com. Thank you!

  • @tunenetrabieso85
    @tunenetrabieso85 3 ปีที่แล้ว

    I have this inverter is possible work with this baterry . I like to know before buy this baterry .
    SAMSUNG SDI 94A 80.9V 7.61KW LITHIUM BATTERY MODULE - DIY SOLAR POWERWALL

    • @Growatt
      @Growatt  3 ปีที่แล้ว

      Hello, you can check the user manual on our website for the inverter ( www.ginverter.com/Off-Grid-Storage-Inverters/44-625.html ). If you need further technical support, please feel free to contact our service team at service@ginverter.com. Our team can provide assistance for you. Thank you!

  • @RandomPsychic
    @RandomPsychic ปีที่แล้ว +1

    the music is soooo distracting....

    • @Growatt
      @Growatt  ปีที่แล้ว

      Thank you for your suggestion.

  • @monsieurd.6890
    @monsieurd.6890 3 ปีที่แล้ว +1

    Beware. What is not said is that this inverter has a 70w void self consumption. So it mean 1.7 kw a day, 3.36 kw a day for a 2 inverter parallel system for a standard house configuration. 1 226 KW per year !
    This is for me the biggest issue.
    You need 1.5 (single) to 3 KW (2 in parallel) batteries only to make the inverters working during night (16 hours in winter) !

    • @Growatt
      @Growatt  3 ปีที่แล้ว

      Hello, for all off-grid inverters, there's always energy loss//power consumption by the inverter. This is normal and unavoidable. For SPF 3500-5000 ES inverter series, the energy loss/consumption by the inverter is around 1%, which is a bit below average of the industry. Combined with other features, this off-grid inverter is a very competitive choice in the market. If you need further product details, you can visit our website at www.ginverter.com/Off-Grid-Storage-Inverters/44-625.html. Thank you!

    • @simonb6110
      @simonb6110 2 ปีที่แล้ว

      Hi Monsieur, I've been looking at one of these and wondering about that. Is 70W a number you know from experience or is it from the specs? The specs I have list "

    • @gregor.potrebujes
      @gregor.potrebujes ปีที่แล้ว

      Good point! I just bought it, but have not yet installed... Has anyone checked the actual power consumption of that inverter? What I would like to know is how much does it consume when powering say 250W load. If it draws 60W with such small loads, that's a huge waste! I hope that's not the case.

    • @monsieurd.6890
      @monsieurd.6890 ปีที่แล้ว +1

      @@gregor.potrebujes my growatt 5000ES eat during night about 75 watts each which is massive I think. As I use 2 of them, 150 watts. 3.6 KW each day. This means we have to add more panels and more batteries. I recommend to add 20 to 30% panels to the maximum that can be produced (because this maximum is never reached). And a big battery.

  • @gramos9115
    @gramos9115 2 ปีที่แล้ว

    Why is there music playing ? this is about information not entertainment , awful

  • @radivojmilin3829
    @radivojmilin3829 ปีที่แล้ว