Troubleshooting AC Servo Drives

แชร์
ฝัง
  • เผยแพร่เมื่อ 16 ม.ค. 2017
  • This video describes troubleshooting for AC servo drives. This is a general purpose video for all types of servo drives. This video goes through visual checks and static checks on the AC servo units.
    Visually, it is important to make sure nothing is burnt or broken. Smell is also important. If anything smells burnt but cannot be visually seen to be burnt, take caution! There may be burnt components in the power section or base of the drive that is hard to see without full disassembly of the drive.
    Static checking should be performed with caution, as it requires using a multimeter to check the different components inside the drive. In this video, Rob explains the exact procedure step-by-step for statically checking the diodes and transistors. Make sure that before performing any static checks that the power has been removed from the drive and the unit has been properly discharged.
    For any questions regarding the information presented here, or any other servo or spindle issues, please visit us at www.precisionzone.net
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 42

  • @akhussain182
    @akhussain182 6 ปีที่แล้ว +2

    Excellent explanation.
    Do you tell us about vfd drives parameter setting according to the motor rating.

  • @Yorumcu63
    @Yorumcu63 7 หลายเดือนก่อน

    Thank you for video

  • @aiasmarques1319
    @aiasmarques1319 6 ปีที่แล้ว

    Very nice video!

  • @MarineTechHub
    @MarineTechHub 6 ปีที่แล้ว

    Very Good explanation and excellent

  • @ritikaanmol9653
    @ritikaanmol9653 5 ปีที่แล้ว

    Thanks for good explanation, can you please give me an favour about BAUMMULER BUS6 , ERROR CODING MEANING.

  • @yahaiya7400
    @yahaiya7400 3 ปีที่แล้ว

    Thanks for this wonderful video I want ask you something I have servo Driver and I have errors I did not find it in the manual it appeared "(error 45 ) " Do you know what does it mean

  • @sudigujjar
    @sudigujjar 6 ปีที่แล้ว

    Nice video

  • @ShimulSiddiqui
    @ShimulSiddiqui 7 ปีที่แล้ว

    Please make a BOSCH SM series servo drive resting system (with encoder) video

  • @Entertainmentcorner12
    @Entertainmentcorner12 5 ปีที่แล้ว

    I have a sanyodenki Sanmotion servo drive. it gives AL-22 overcurrent 1 alarm right after turning on power. If there is any solution do let me know

  • @MrJzplastic
    @MrJzplastic 3 ปีที่แล้ว

    Do you prefer Hioki over Fluke? and why?

  • @michealvino6355
    @michealvino6355 2 ปีที่แล้ว

    How to Identify DB Relay in a Fanuc Servo Drive ?
    Can you suggest...
    Thanks in Advance...

  • @sharifhossain8830
    @sharifhossain8830 2 ปีที่แล้ว

    What's servo inverter? Which are used to control ac induction motor, such as Lenze 9300, 8400 etc
    Please answer....

  • @pradyumnapatra3192
    @pradyumnapatra3192 2 ปีที่แล้ว

    During checking of igbt, why it shows 0.3 to 0.7 voltage and what is it ?

  • @ATBPRODUCTION17
    @ATBPRODUCTION17 ปีที่แล้ว

    I have a servo amplifier a20b-2101-039 malfunction appears alarm 03 . Guess what part is the damage?

  • @truekev1
    @truekev1 6 ปีที่แล้ว

    whats this used for?

  • @phongcodienliendoanh6770
    @phongcodienliendoanh6770 2 ปีที่แล้ว

    my driver servo MR-J3 10a cannot save any setting parameters and a blinker dot behind fourth degit. how can i fit it ?

  • @night_grinder1378
    @night_grinder1378 ปีที่แล้ว

    is that a IGBT TEST?

  • @khetikimaza7000
    @khetikimaza7000 ปีที่แล้ว

    Hello sir, how to check servo drive and servo motor are faulty or not ..share me procedure for check servo drive and motor

  • @manjunathkaradi2488
    @manjunathkaradi2488 2 ปีที่แล้ว

    Thanks sir for explanation
    Please our problem solve
    Mustibushi Mr j2s 40 a servo drive continues alarm comming AL 25

  • @elevatorsasansorler
    @elevatorsasansorler 5 ปีที่แล้ว

    Good

  • @abuhanifazadazad2142
    @abuhanifazadazad2142 2 ปีที่แล้ว

    How to find out inside circuit or short

  • @lighthouse6208
    @lighthouse6208 6 ปีที่แล้ว

    I have a servo amp fanuc A06B-6096-H116 now 8. alarm sometime display. Please guide for me check it.
    Thank you verry much

    • @shivanagaral8059
      @shivanagaral8059 6 ปีที่แล้ว

      Light House
      Please check with its power module and motor insulation
      If both are ok it can be sent to repair

  • @emmersonclaveria8203
    @emmersonclaveria8203 3 ปีที่แล้ว

    Our machine encountered unusual sound after we replaced servo pack driver the unusual sound gone. What is the possible trouble of servo pack driver?
    thanks!

  • @rojherlaguna3729
    @rojherlaguna3729 5 ปีที่แล้ว

    Regards
    I need to control 5 servo motors and drivers from my computer, what motion controller card recommends me to retrofit my vertical milling machine to a CNC machine and with what software does it work?
    1. AC SERVO MOTOR HF-SP102 MITSUBISHI (01) Axis X
    INPUT 3AC 125V 5.3 A
    OUTPUT 1 Kw - 2.000 rpm
    SERVODRIVER - MITSUBISHI
    MODEL: MR-J3-100A (Analog)
    POWER: 1KW
    INPUT: 5.0 A 3PH+1PH200-230V 50/60 Hz
    OUTPUT: 170 V 0-360Hz 6.0 A
    2. AC SERVO MOTOR HF-SP152 MITSUBISHI (01) Axis Y
    INPUT 3AC 126V 8.0 A
    OUTPUT 1.5 Kw - 2.000 rpm
    SERVODRIVER - MITSUBISHI
    MODEL: MR-J3-200A (Analaog)
    POWER: 2KW
    INPUT: 10.5 A 3PH+1PH200-230V 50/60 Hz
    OUTPUT: 170 V 0-360Hz 11.0A
    3. AC SERVO MOTOR HC-SF202 MITSUBISHI (01) Axis Z
    INPUT 3AC 138 V 11A
    OUTPUT 2.0 Kw - 2.000 rpm
    SERVODRIVER - MITSUBISHI
    MODEL: MR-H200TN
    POWER: 2.0 KW
    INPUT: AC200V - 230 V 50/60Hz
    OUTPUT: 10A
    Thank you
    --
    Ing. Rojher Laguna
    rojher.laguna@gmail.com

  • @sonyalindy362
    @sonyalindy362 3 ปีที่แล้ว

    4:44 what do you mean by "inputs and outputs are shorted to ground"? Why do you want that?

    • @yacinedali2756
      @yacinedali2756 2 ปีที่แล้ว

      it means that there is no short circuit between them and ground, as far as i know

    • @nabilmarsel8792
      @nabilmarsel8792 ปีที่แล้ว

      @@yacinedali2756 hello, please what the purpose of the last checking when he switch between the probs (positive to negative of DC, and negative to positive DC.)

  • @duynguyenkhuong2864
    @duynguyenkhuong2864 6 ปีที่แล้ว

    thanks your video

  • @industriasmurcia44
    @industriasmurcia44 6 ปีที่แล้ว

    When i start my machine indicate failure 11 and check it out like the video, all the values indicate is ok. But this failure is Causes:
    High power impedance, PCB or transistor module are defective.
    Solution:
    Check AC power, replace damaged Fanuc part.
    You can repair correct?

    • @Promilus1984
      @Promilus1984 5 ปีที่แล้ว

      That's just simple method to verify if there's no shorted semiconductor. But sometimes (mosfet and igbt) are degraded in that way they won't show up S/C with low voltage probe of DMM. But if you apply high CE voltage (e.g. megger) it might show up a lot lower resistance than fully functional (so current "leaking out" despite transistor being turned off). During inverter operation it might lead to invalid motor rotation, eventual short circuit in output stage, blown off igbt, fuses, tracks, caps etc. or just desaturation error (and immediate stop) if drive is smart enough. Some drives use controlled rectifier at inputs so it can regulate charging of DC bus caps (no big inrush current at startup) without using NTC+resistor+relay and similar. Usually SCRs brake down to S/C state but sometimes it is open circuit. If that's the case drive might see it takes too long time to charge up caps (so it lost 1 phase). Or if there are indeed series pre-charge resistors they might be damaged and have too much resistance to charge up caps.

  • @mauriciojimenez1505
    @mauriciojimenez1505 4 ปีที่แล้ว

    Las reparaciones son costosas con los proveedores Aveces si hay manera de ver estos tutoriales te ahorras costos de reparaciones solo de refacciones

    • @losmasbusk2nc
      @losmasbusk2nc 3 ปีที่แล้ว

      Casi la mayoría de los proveedores en México se quieren hacer ricos con las reparaciones, te sacan un ojo, existe esta empresa en Monterrey, el mismo dueño repara, y da precios muy accesibles la verdad, www.mvelectronics.mx te los recomiendo trabajan muy bien

  • @alfonsoalvarez5044
    @alfonsoalvarez5044 หลายเดือนก่อน

    Hola, el video parece bueno, pero sería mucho mejor si lo traduce al español o castellano, llegaría a ser más interesante

  • @user-xk2er3ly4j
    @user-xk2er3ly4j 4 ปีที่แล้ว

    FANUC system 700 error

  • @lighthouse6208
    @lighthouse6208 6 ปีที่แล้ว

    Hi ad
    Please help me

  • @BeautyBattleZone
    @BeautyBattleZone 6 หลายเดือนก่อน

    Alarm 101 atinya apa

  • @barbarossa7872
    @barbarossa7872 6 ปีที่แล้ว

    in chat a la

  • @oleguretiy3221
    @oleguretiy3221 2 ปีที่แล้ว

    Bad company

  • @manjunathkaradi2488
    @manjunathkaradi2488 2 ปีที่แล้ว

    Thanks sir for explanation
    Please our problem solve
    Mustibushi Mr j2s 40 a servo drive continues alarm comming AL 25