How to Install a Gas Clothes Dryer | Ask This Old House

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ส.ค. 2024
  • Ask This Old House plumbing and heating expert Richard Trethewey helps an expecting couple select and install a gas dryer.
    SUBSCRIBE to This Old House: bit.ly/Subscrib...
    Time: 3-4 hours
    Cost: $800 and up
    Skill Level: Expert - licensed professionals only
    Tools List for Installing a Gas Clothes Dryer:
    Pipe wrench (x2)
    Drill
    Hole saw
    Screwdriver
    Shopping List:
    Gas pipes
    Gas pipe fittings
    Gas nipples
    Pipe dope
    Dryer vent
    Dryer vent cover
    Flexible gas connector
    Gas leak detector
    Gas tubing hanger
    Steps:
    1. Any work involving gas can be dangerous and should be left to a licensed professional.
    2. Start by shutting off the gas at the meter using a wrench or at the nearest gas shutoff upstream of where the new gas work will happen.
    3. Measure and connect a series of gas pipes, fittings and nipples to the source of the gas to the rough location of the dryer. Secure all the connections between the pipes and the fittings with pipe dope and tighten them with the wrenches.
    4. At the bottom of the gas work closest to the dryer, add a drip cap to allow for a sediment clean out.
    5. Connect the flexible gas line to the end of the new gas pipes and then to the gas fitting on the dryer using the wrenches.
    6. Drill a hole in the exterior wall where the dryer will vent. Do this using the drill with a hole saw attachment.
    7. Insert the dryer vent cover into the dryer vent and tighten the clamp with a screwdriver until it’s secure.
    8. Feed the dryer vent into the wall and then screw the dryer vent cover to the exterior wall.
    9. Connect the dryer vent to the dryer and secure it to the dryer using a clamp and the screwdriver.
    10. Plug in the dryer (this power is only to spin the drum) and turn the gas back on.
    11. Test all the new gas work for any leaks using a leak detector.
    12. Once you’ve confirmed the gas work is all perfectly sealed, secure the pipes to the walls using screws and the gas tubing hangers.
    Resources:
    Richard recommends that if the electrical service to the house is insufficient, a gas dryer could be a more suitable option for installation. Working with gas can be extremely dangerous, so, as with any other gas appliances in the house, this type of work should only be handled by a licensed professional.
    Richard installed a 120V gas vented dryer, which is manufactured by GE Appliances (www.geapplianc.... The other materials he used for this installation, including the black gas pipes, fittings, nipples, and pipe dope, can all be found at home centers.
    About Ask This Old House TV:
    Homeowners have a virtual truckload of questions for us on smaller projects, and we're ready to answer. Ask This Old House solves the steady stream of home improvement problems faced by our viewers-and we make house calls! Ask This Old House features some familiar faces from This Old House, including Kevin O'Connor, general contractor Tom Silva, plumbing and heating expert Richard Trethewey, and landscape contractor Roger Cook.
    Follow This Old House and Ask This Old House:
    Facebook: bit.ly/ThisOldH...
    Twitter: bit.ly/ThisOldH...
    bit.ly/AskTOHTw...
    Pinterest: bit.ly/ThisOldH...
    Instagram: bit.ly/ThisOldH...
    bit.ly/AskTOHIG
    Tumblr: bit.ly/ThisOldH...
    For more on This Old House and Ask This Old House, visit us at: bit.ly/ThisOldH...
    How to Install a Gas Clothes Dryer | Ask This Old House
    / thisoldhouse

ความคิดเห็น • 358

  • @heroshyma69
    @heroshyma69 5 ปีที่แล้ว +148

    Honestly, this old house is the best thing on TH-cam. Never stop educating us!

    • @AdamJames.
      @AdamJames. 3 ปีที่แล้ว

      Hey this old house where is ♥️ for me

    • @lvsweets
      @lvsweets 3 ปีที่แล้ว +1

      Facts I've been watching since I was 9 yrs old.

    • @briantheguy1
      @briantheguy1 2 ปีที่แล้ว

      So old he still uses the 220v term vs 240v. Old school house, long time watcher.

  • @jeremymedlock9626
    @jeremymedlock9626 5 ปีที่แล้ว +142

    "Gas piping should always be done by a professional"
    Me: I know what i'm doing. How did I learn? By watching This Old House.

    • @n9wox
      @n9wox 4 ปีที่แล้ว +3

      I think this is required by law in MA.

    • @andyruse4670
      @andyruse4670 4 ปีที่แล้ว

      @Tom Cartmel check your local regulations of course. All I know is that in other states property owners doing the work themselves merely have to get a permit if anything.

    • @noanyobiseniss7462
      @noanyobiseniss7462 3 ปีที่แล้ว +1

      I was going to post this same exact thing! lol

    • @joeyprather4739
      @joeyprather4739 ปีที่แล้ว

      @@n9woxMA requires a lot of things

  • @N3VADAN
    @N3VADAN 5 ปีที่แล้ว +59

    Glad you guys liked it. Here's my bill for $1500 see you later.

  • @Skammerd
    @Skammerd 5 ปีที่แล้ว +49

    I love Rich. He loves to bust chops in a friendly way. "No mancave down there..." Probably a fun guy to hang out with.

    • @davidciaffa4711
      @davidciaffa4711 3 ปีที่แล้ว

      Met him at a home show several years ago. He's a super nice, down to earth guy.

    • @oldtwinsna8347
      @oldtwinsna8347 ปีที่แล้ว

      He goes by Richard, not Rich.

  • @cup_and_cone
    @cup_and_cone 5 ปีที่แล้ว +39

    I don't recommend plastic louvered exhaust vents...I just got done replacing the one on our new house two weeks ago because a louver broke off... It was only three years old. The combination of exhaust heat from the dryer and UV from sunlight made the plastic extremely brittle. The remaining louvers literally crumbled in my hand.

    • @oldtwinsna8347
      @oldtwinsna8347 5 ปีที่แล้ว

      agreed, wouldn't use in area exposed to any sunlight. shaded should last longer.

    • @denisrhodes54
      @denisrhodes54 5 ปีที่แล้ว

      work fine on the north side or without direct sunlight

    • @ThusIsBrad
      @ThusIsBrad 5 ปีที่แล้ว +1

      It literally, not figuratively, crumbled.

    • @jgroenveld1268
      @jgroenveld1268 4 ปีที่แล้ว +3

      I bought my house and was trying to work out how the dryer was vented. Checked the walls, the roof, attic, etc but still could find it. What I later realised they had vented it into the vent pipe for the plumbing.

    • @n9wox
      @n9wox 4 ปีที่แล้ว +1

      I agree. After getting lint on them, the louvers tend to not want to close all the way and let in cold air. This style of vent works much better. www.lambro.net/product/4-dryer-vent-seal/

  • @matthewostendarp8924
    @matthewostendarp8924 5 ปีที่แล้ว +91

    I just happened to have a gas dryer in my truck.

    • @ozziesheppard17
      @ozziesheppard17 5 ปีที่แล้ว +15

      You know, he's got a 12,000 sqft express van.

  • @jeffjeffjeff
    @jeffjeffjeff 3 ปีที่แล้ว +4

    This Old House comes to install your new dryer hookup. Let's put the vent and gas connection like 8 feet apart so the vent has to stretch across the wall!

  • @kingofthecarwashes6724
    @kingofthecarwashes6724 2 ปีที่แล้ว +14

    There is one concern out of the whole installation, that would be the dryer vent, that paper pipe is a fire hazard due to it being flammable, I would use either the aluminum flexible pipe or the solid sheet metal pipe, other than that the installation was perfect and I want to be an HVAC technician and a plumber and these videos are really inspiring and I learn a lot from them.

    • @BeachTree
      @BeachTree ปีที่แล้ว +4

      Im pretty sure that was aluminum

  • @saschaschneider2749
    @saschaschneider2749 3 ปีที่แล้ว +1

    I've been watching this old house for over 30year great show the good old days

  • @Saved4Life777
    @Saved4Life777 5 ปีที่แล้ว +10

    Her glasses are epic. Feels like I’m back in 1990!

  • @ClaytonNummer
    @ClaytonNummer 5 ปีที่แล้ว +102

    I'm a little disappointed that rigid ducting wasn't used for the dryer vent, especially with such an easy, short run...

    • @StoneE4
      @StoneE4 5 ปีที่แล้ว +13

      No need to be. Flexible duct works great. As long as your municipality's codes allow for it there is no problem in using it.

    • @ClaytonNummer
      @ClaytonNummer 5 ปีที่แล้ว +26

      @@StoneE4 It might be adequate, but it will still collect more lint, and if the mylar type is used it's extremely flammable. I can justify doing things "good enough" when there's a good reason but the extra time/cost in this case would be minuscule.

    • @augustreil
      @augustreil 5 ปีที่แล้ว +3

      @@ClaytonNummer, Agree.

    • @StoneE4
      @StoneE4 5 ปีที่แล้ว +7

      Clayton Nummer - The mylar flex duct becomes more and more brittle with each successive heat cycle from the dryer. Subsequently, it doesn't take too long before that stuff starts to fall apart. As to whether or not it's flammable, I don't know. But, I _seriously_ doubt that. Nonetheless, I strongly advise against using that crap. However, the foil type and the semi-rigid type are just fine to use. They may build up lint faster than rigid metal duct, but not enough to cause any safety concerns. The vast majority of lint build-up in dryer ducts is not due to the type of ductwork used, it's due to people not cleaning their lint screens, having too long a run, crushed ductwork, too many bends in the line, and foreign obstructions. Those issues can be just as big of a problem with rigid metal lines as with flex lines.
      There are two main rules to follow if you want to keep a dryer working properly and safely... (1.) Clean your lint screen every time you use it, and (2.) keep the vent line as short and straight as possible. Follow those rules and you won't have many problems with flex duct or rigid metal duct.

    • @RupertAH
      @RupertAH 5 ปีที่แล้ว +13

      I find it hilarious all the keyboard professionals that show up in the comment sections on This Old House and Ask This Old House episodes on TH-cam who think they know better than people who have been doing their trades for decades. If rigid ducting wasn’t used there is a good reason for it.

  • @Nikodymus
    @Nikodymus 4 ปีที่แล้ว +3

    If you guys could direct a “This Old Car” channel, formatted JUST like this?? You’d be the most valuable educators in the world!!

    • @jonathanalea
      @jonathanalea 3 ปีที่แล้ว +1

      You don’t like Scotty Kilmer yelling all the time?

    • @Nikodymus
      @Nikodymus 3 ปีที่แล้ว

      Jonathan Lea I feel bad because I don’t know who that is, but I was referring to this exact teaching style and method

    • @jonathanalea
      @jonathanalea 3 ปีที่แล้ว +2

      Scotty Kilmer is on TH-cam and has car repair tutorials and advice. He knows his stuff but he’s always yelling.

    • @dazednconfusedrn
      @dazednconfusedrn 3 ปีที่แล้ว +2

      @@Nikodymus Scotty kilmers the best 😂

    • @Nikodymus
      @Nikodymus 3 ปีที่แล้ว +2

      @@jonathanalea update, I found him. And he’s awesome!

  • @JP-od9ps
    @JP-od9ps 4 ปีที่แล้ว +4

    The flexible duct exhaust which was installed is flammable if I’m not mistaken. Rigid is the best way to go. Especially since it’s in an open area.

    • @aldrinw706
      @aldrinw706 3 ปีที่แล้ว +3

      you are mistaken

    • @stevesullivan9752
      @stevesullivan9752 3 ปีที่แล้ว +1

      It is not flammable... please stop repeating old wives tales.

    • @Cpcsof1
      @Cpcsof1 3 ปีที่แล้ว +2

      @@stevesullivan9752
      It's not an old wives tale. TH-cam video by the dryer vent dr shows the flexible aluminium foil vent hose catch fire and burn immediately when a flame is applied. There is paper under the foil.

    • @thehawk05
      @thehawk05 ปีที่แล้ว

      @@stevesullivan9752
      The duct type used in this video is absolutely flammable……plenty of videos on TH-cam illustrate that fact. If one insists on using a flexible vent pipe there are ones made entirely of aluminum.
      With that said a solid vent pipe is always best as flexible vent pipes don’t flow as well and also are prone to lint buildup

    • @BenKlassen1
      @BenKlassen1 11 หลายเดือนก่อน

      Yes, current international fuel gas codes require semi-rigid or rigid vent ducting for gas-fired dryers. Semi-rigid duct runs can't be as long as rigid ones.

  • @BigAlWillis
    @BigAlWillis 2 ปีที่แล้ว +2

    with carbon monoxide I like to use hard pipe for gas dryer venting. The flexible stuff can be damaged easily.

  • @michaelcicero4423
    @michaelcicero4423 ปีที่แล้ว +3

    I love how dead inside these guys are. It’s my favorite part of This Old House!

  • @verdatum
    @verdatum 5 ปีที่แล้ว +3

    That light in the background at the 1:50 mark is really cool.

  • @briancarter1597
    @briancarter1597 5 ปีที่แล้ว +3

    Finally a picture of the finished product. Thanks TOH!

    • @Kirby7601
      @Kirby7601 หลายเดือนก่อน

      "thanks toh" the owl house

  • @mr.dahliaking.202
    @mr.dahliaking.202 4 ปีที่แล้ว +11

    I always thought that gas is this mortifying thing that can start to leak at any time because it is under pressure like water mains. But it turns out, I didn't knew, that gas is almost as strong pressure as your breath. If you have a gas pipe wide open, you can take your finger and gently put it on the hole and it will stop the pressure. It is literally as strong as your breath.. I was really surprised by it, I always thought that gas pipe, if broken, it will whistle gas like mains water, but it turns out that it isn't the case.

    • @fartpluswetone8077
      @fartpluswetone8077 4 ปีที่แล้ว +2

      Probably best to put a carbon monoxide alarm in there. As for the gas leaking, it should be detectable through smell.

    • @stephensnell1379
      @stephensnell1379 3 ปีที่แล้ว +2

      @@fartpluswetone8077 you should know Carbon Monoxide is completely odourless

    • @fartpluswetone8077
      @fartpluswetone8077 3 ปีที่แล้ว +5

      @@stephensnell1379 Natural Gas and Propane fuels are treated with Methyl Mecarptan to give off a rotten egg smell.

    • @fartpluswetone8077
      @fartpluswetone8077 3 ปีที่แล้ว

      Well, that's the case for commercial and residential use.

  • @edpoisson7065
    @edpoisson7065 5 ปีที่แล้ว +26

    I thought the dryer was shrinking my clothes, turns out it was the refrigerator

  • @snuckyr
    @snuckyr 5 ปีที่แล้ว +11

    i love how they just have a sheet of plywood in place where a window used to be

    • @n9wox
      @n9wox 4 ปีที่แล้ว

      0:59 Plywood was already there to replace the glass in the window well.

  • @djscrizzle
    @djscrizzle 3 ปีที่แล้ว +5

    That foil venting seems a little hokey. I prefer to install 24g steel smoke pipe and fittings that are taped and properly supported

    • @djscrizzle
      @djscrizzle 2 ปีที่แล้ว

      @@dancooper6002 A gas dryer.

  • @eluniversodelecuador
    @eluniversodelecuador 5 ปีที่แล้ว +1

    Whirlpool 4396009RP flexible hose and 4396006RW close elbow will work great!

  • @jomangeee9180
    @jomangeee9180 5 ปีที่แล้ว +34

    always call the plumber before you have the baby!!! LMAOL

    • @thedelightfullytacky
      @thedelightfullytacky 4 ปีที่แล้ว +2

      Occasionally, the plumber is responsible for having the baby... ;-)

  • @glassman1533
    @glassman1533 10 หลายเดือนก่อน

    Fast Forward to 2023. All they need is a GE All in One. No need for gas, venting or a 240 volt outlet.

  • @cliffordalexo234
    @cliffordalexo234 4 ปีที่แล้ว +1

    TH-cam's best . Good luck guys .

  • @CoasterCrazyy
    @CoasterCrazyy 2 ปีที่แล้ว +3

    You are supposed to use a little of the flexible duct as possible btw, It has a horrible airflow rating, 1 foot = 4 feet normal tin pipe.

  • @HAMRADIOJOE4178
    @HAMRADIOJOE4178 5 ปีที่แล้ว +6

    YOUR A GOOD BOY RICHARD

  • @Datsun7705
    @Datsun7705 4 ปีที่แล้ว +4

    That type of exhaust duct is not recommended for dryer use as lint can easily get trapped and possibly cause a fire.

  • @vegasfordguy
    @vegasfordguy 5 ปีที่แล้ว +3

    All of the electrical is a mess in that house. A fire just waiting to happen. I agree with you guys about the flex duct, pretty cheesey. I didn't expect to see this on ATOH.

  • @viktorosipov1174
    @viktorosipov1174 5 ปีที่แล้ว

    12/2 with ground Romex works on furnaces appliances and bathroom circuits

  • @scottbaker8018
    @scottbaker8018 5 ปีที่แล้ว +14

    Can they run the washer, dryer, and air conditioner at the same time with that little panel?

    • @ozziesheppard17
      @ozziesheppard17 5 ปีที่แล้ว +2

      ya, thats only about 25 amps, If they all switch to led lights and a efficent airconditioner 60 is "enough" if they dont have an electric oven or dryer. But its still tight to say the least.

    • @briancarter1597
      @briancarter1597 5 ปีที่แล้ว +1

      Probably not. I have that same issue. I have to turn the AC off to use my washer/dryer.

    • @ozziesheppard17
      @ozziesheppard17 5 ปีที่แล้ว +1

      @@briancarter1597 Well it depends of a few factors- the physical size of the panel is irrelevant, thats a 60 amp panel- which probably also leads to a sub panel somewhere. It really depends on your over all usage through out the house- by switch to all led you can save 15 amps easily in a house (equal to 2 window ac's) the running amperage of a two 1/2 ton system is about that much for a modern unit so just by switching out the light bulbs you effectively made room to run the ac 24/7 in addition to what you usually do.
      If you go around the house and cut out the wasteful usage you'll save a ton of energy and free up allot of amps even in a small panel.

    • @Nsingh11
      @Nsingh11 5 ปีที่แล้ว +1

      Well if they already been running everything prior to the dryer I'm sure the gas dryer won't have tremendous impact

    • @briancarter1597
      @briancarter1597 5 ปีที่แล้ว

      @@ozziesheppard17 Are you getting paid by the LED Council or something? Stop mentioning LED's! :P

  • @briancnc
    @briancnc 5 ปีที่แล้ว +34

    Richard, seriously? Flex duct? You rail against this and have even replaced it in other videos showing it's failures and downside with lint. Easiest run to do with rigid pipe, this was just beyond lazy. If you use rigid pipe you will almost never have to clean it. With heating/cooling cycles over time this mylar flex duct degrades and can open up.

    • @Mike__B
      @Mike__B 5 ปีที่แล้ว

      Was thinking the same thing, it's a straight shot too with the only elbows at the drier and the hole in the wall.

    • @Brian-Burke
      @Brian-Burke 5 ปีที่แล้ว

      You read my mind. I specifically remember the video of them comparing vent duct types.

    • @Skammerd
      @Skammerd 5 ปีที่แล้ว +3

      Between having to run the duct between a window boarded up with uninsulated plywood, and a 60A breaker box, I think he just wanted to get out of there. Did you see that he didn't even plug the dryer into the closest outlet? It probably didn't even work. I think the demo on having to run gas pipe was enough entertainment value. The homeowner could barely squeeze into the side of the house to help run the duct. This house didn't have a washer and dryer because it seriously wasn't equipped to handle it. I think Rich did his best in the time and budget allotted.

    • @Mike__B
      @Mike__B 5 ปีที่แล้ว +3

      @@Skammerd True, home owner probably bought the washer/dryer set (because for some reason they give you deals if you buy both but not just one), plus he bought the vent kit too and Rich just did the installation of the gas pipe to make it all happen.
      Heck the floor of the basement almost looked like dirt.

    • @Skammerd
      @Skammerd 5 ปีที่แล้ว +2

      @@Mike__B I think it's what they call a "cellar" up there in New England. Actual stone foundation wall!

  • @bryanevans111
    @bryanevans111 3 ปีที่แล้ว +8

    I dont think I would ever use the mylar exhaust hose for a gas dryer. You could easily tear or rip it and have poisonous gases enter your home. Consider using sheet metal ducting and metal tape the seams. CHEERS :)

  • @egg928
    @egg928 3 ปีที่แล้ว

    I have a electric dryer instead of the additional gas I only have one 240 Volt plug and it’s in the best place for a dryer so my only option was electric
    (With no gas lines) and no 120 volt plug only 240

  • @chrissimon8403
    @chrissimon8403 5 ปีที่แล้ว +4

    I just happen to have a wooden window to run the vent through lol, but good information.

    • @marcosmota1094
      @marcosmota1094 5 ปีที่แล้ว

      That "window" faces a back area where someone can break in. Also, do you really want a window on a secluded side of the basement when your family is down there doing work? I've plugged windows with reinforced wood for said reasons.

  • @PatrickPoet
    @PatrickPoet 5 ปีที่แล้ว +1

    I love this couple. They are perfect together. I love how you guys empower them. I love This Old House

    • @goodgoyim9459
      @goodgoyim9459 5 ปีที่แล้ว +14

      right, cause they will be divorced within a year and/or the black daddy will be long gone. lmao

  • @grumpyponies
    @grumpyponies 5 ปีที่แล้ว +3

    Is there a reason you're using steel piping as opposed to polyurethane which is being used as a replacement for many gas mains?

    • @lopincol
      @lopincol 4 ปีที่แล้ว +1

      Plastic pipes are only allowed underground and not inside/outside buildings.

    • @djscrizzle
      @djscrizzle 3 ปีที่แล้ว

      IPC and UPC, both model plumbing codes in the United States, call for laquored black iron pipe, or copper is allowed on propane systems. Most pipe fitters do thread their own on site from 21ft sticks, off their truck. And they use pipe dope almost universally. In some states, you'll find a left-right nipple and coupling used instead of unions.

  • @IAmNotAFunguy
    @IAmNotAFunguy 5 ปีที่แล้ว +1

    That washer is one of the new 2018 Kenmore Elite top load washers with an agitator. At least they have a good taste on functional laundry appliances.

    • @aaronbays4
      @aaronbays4 5 ปีที่แล้ว +1

      And what happens to the warranty or parts availability when Sears goes out of business within the next year or so??? There hasn't been a Sears store in my area for the past 5-6 years either.

    • @dodgeramsport01
      @dodgeramsport01 4 ปีที่แล้ว

      @@aaronbays4 nothing will happen Kenmore is for sale, so it will be the same!

    • @RoastBeefSandwich
      @RoastBeefSandwich 4 ปีที่แล้ว

      @@aaronbays4 someone will buy Kenmore and retain service contracts. When Sears sold Craftsman, Stanley Black & Decker agreed to take over the famous lifetime warranty. The same will happen with Kenmore.

    • @jessesan2003
      @jessesan2003 3 ปีที่แล้ว

      Whirlpool makes Kenmore dryer.

  • @grandn8646
    @grandn8646 5 ปีที่แล้ว +7

    Well I was going to comment about the flexible duct, instead of rigid but I see there was already a few posts on it .

    • @Whadatd
      @Whadatd 5 ปีที่แล้ว

      grandn 86 wait what’s so better about flexible?

    • @grandn8646
      @grandn8646 5 ปีที่แล้ว

      I think you misunderstood my comment. Rigid venting to me is much better, There is more chance of lint getting built up inside the ribs of flexible venting. To me, not a good idea, especially with it being a gas dryer.

  • @Mackandal-
    @Mackandal- 3 ปีที่แล้ว

    Great Episode!

  • @SilentServiceCode
    @SilentServiceCode 5 ปีที่แล้ว +1

    OH SNAP NEW THIS OLD HOUSE

  • @etem.a.4974
    @etem.a.4974 4 ปีที่แล้ว +1

    Between steel and copper which is the best for gas piping....

    • @R_A_3000
      @R_A_3000 3 ปีที่แล้ว

      Steel is for gas and copper is for water.

    • @stevesullivan9752
      @stevesullivan9752 3 ปีที่แล้ว

      @@R_A_3000 not necessarily Rene. Copper IS used for various gas lines... especially in hospitals.

  • @TheMixmastamike1000
    @TheMixmastamike1000 5 ปีที่แล้ว +3

    beautiful family

  • @minhdo2896
    @minhdo2896 5 ปีที่แล้ว +4

    Are these home owner actors? Or how to we get this old house to come to our house? Just wondering

    • @Luckingsworth
      @Luckingsworth 5 ปีที่แล้ว +1

      You contact the show saying your project and they come. Note that you still have to pay for most of it. You just get reduced price on labour.

  • @DaBrowns33
    @DaBrowns33 5 ปีที่แล้ว

    That montage music just touches my soul.

  • @malibuman8941
    @malibuman8941 3 หลายเดือนก่อน

    they don't talk about the details.. size of duct, size of flex gas line fittings

  • @augustreil
    @augustreil 5 ปีที่แล้ว +11

    I'm surprised Richard used that flexible exhaust and not the smooth bore type ?

    • @randomsanwhich2
      @randomsanwhich2 5 ปีที่แล้ว +3

      Yes, that flexible ducting is a fire hazard

    • @g36killer
      @g36killer 5 ปีที่แล้ว +3

      If you clean or replace it every year. It should be fine.

    • @ericspda
      @ericspda 5 ปีที่แล้ว +2

      In tests simulating a real dryer fire, the rigid ducts burn though in under a minute anyways. It will flow better, and is a bit more fire resistant, but it will still likely burn. Although I assume he did it since it works fine and is way cheaper and easier.

    • @augustreil
      @augustreil 5 ปีที่แล้ว +2

      @@g36killer, No doubt, but with such a short easy install, I just figured he would have used the smooth duct, that's all.

    • @briancnc
      @briancnc 5 ปีที่แล้ว +4

      @@g36killer If you use rigid duct you don't have to clean it out almost ever!

  • @JimDean002
    @JimDean002 8 หลายเดือนก่อน

    I'm just going to add here that it's not as much about younger men not having the mechanical ability it's about them not having been introduced to a culture where you understand that you do have the mechanical ability You just have to dive in and figure it out. I've started more projects in my life that I had no idea how I was going to finish but I knew I either had a group of friends that knew or nowadays I had TH-cam. Unless it was something that was inherently dangerous I was more than willing to jump in and still am. So more than the mechanical knowledge that my dad gave me which was largely directed at engines that use points and chokes and carburetors which is useless now or how you can put white lead in a differential and make it act like new for a little while, he let me know that I can figure it out. My kid comes home with a busted radiator... You go buy one and you put it in. TH-cam is your best friend now

  • @armandoquirarte148
    @armandoquirarte148 2 ปีที่แล้ว

    When I open the gas valve… is it normal to hear it sound? How lo h should I leave the gas open? I can actually smell gas…

  • @BuildGreenHomesNow
    @BuildGreenHomesNow 5 ปีที่แล้ว +2

    Nice lint trap. Richard trying to take out family slowly

  • @prakashgudimetlagudimetlap2533
    @prakashgudimetlagudimetlap2533 5 ปีที่แล้ว +1

    Good project

  • @sheachopper6416
    @sheachopper6416 5 ปีที่แล้ว +12

    60amp service? what is this, the 20s? lmfao damn upgrade that panel!

    • @scarrypolpetta9006
      @scarrypolpetta9006 5 ปีที่แล้ว

      In europe we have 16A service usually
      It's 230v and not 110 but it would still be not more than 32 A, and we live with it

    • @Vanilla_Icecream1231
      @Vanilla_Icecream1231 4 ปีที่แล้ว

      i have 100 AMPS

  • @whitemotel
    @whitemotel 3 ปีที่แล้ว

    i think i would have them run a new circuit vs using gas...

  • @chaycekyle9156
    @chaycekyle9156 5 ปีที่แล้ว

    Can you come Michigan please we dishwasher install in the new faucet and sink fixed

  • @le28leee
    @le28leee 2 ปีที่แล้ว

    What about gas operated central air conditioner or ac unit

  • @georgekabacinski
    @georgekabacinski 3 ปีที่แล้ว

    When to choose a rigid v. flex vent? Another recent dryer install video showed using rigid vent pipe. Neither indicates when one form is more suitable to a situation than the other.

    • @nick4leader
      @nick4leader 2 ปีที่แล้ว +1

      I have no idea why he chose that vent duct. Best would be rigid but secondarily there is a semi rigid one that's kind of in-between

    • @CoasterCrazyy
      @CoasterCrazyy 2 ปีที่แล้ว

      Hard pipe and elbows are always preferred over the flexible duct, if you are going to use flexible duct use as little as possible. Its only used so that you can make the connection and have the dryer be closer to the wall. Connecting hard pipe to the dryer when it up against the wall can be very difficult.

  • @valentinamejia6756
    @valentinamejia6756 5 ปีที่แล้ว

    Good job guys 👍🏻😉

  • @luktish
    @luktish 5 ปีที่แล้ว

    I have a question about the diameter of the outlet on the meter. It is currently 1" diameter. I will have somewhere about 90' of pipe from the meter to the furthest appliance. So I would like to attach a 1.5" pipe to the meter. Can you install a 1.5" diameter outlet on the gas meter with 1" outlet? From my understanding, attaching 1.5" pipe to the 1" outlet on the meter would create a bottle neck right there? Thanks

  • @roberth7559
    @roberth7559 3 ปีที่แล้ว +1

    It's cast iron, not steel
    Surprised to see the utilization of flex hose for ventilation

    • @flat-earther
      @flat-earther 2 ปีที่แล้ว

      What is cast iron, the pipes?! You sure they aren't steel

    • @roberth7559
      @roberth7559 2 ปีที่แล้ว +1

      @@flat-earther Hi! I misspoke - it's technically steel

  • @Fusiongearz
    @Fusiongearz 5 ปีที่แล้ว

    good upload boys keep it up

  • @hungkiet7535
    @hungkiet7535 4 ปีที่แล้ว +1

    I wish I can do this

  • @marksmith5696
    @marksmith5696 3 ปีที่แล้ว

    I have the exact same GE gas dryer. Used once a week for 30 minutes, only on low. A year and half old. Now, no power. Replaced door switch, that did not solve the problem. GE is coming out to fix it. VERY Disappointing because it was a $900 dryer barely used.

    • @ahaning
      @ahaning 3 ปีที่แล้ว

      My electric dryer (Roper/Whirlpool) had a no-start condition. The door switch, thermal fuses, timer, and motor all seemed good and the fuses and door switch tested OK. First I replaced the timer, no luck. Tried replacing the thermal fuse for fun since they're about $1-2 each when bought in bulk. Still no luck, but I do have enough dryer thermal fuses for the rest of my life. I broke down and ordered a new motor. STILL NO LUCK. Argh that thing was expensive!
      It turned out to be the motor wiring harness clip thing not making a good connection with the motor. A zip tie tied gently but snugly around a loop of the motor wires tightened things up and it's been running fine for over a year. A $0.05 zip tie fixed the problem. *smack*
      Gas dryers are going to be a little more complex than electric, but electric are so simple (with lots of safety features) that I can't imagine that the gas variants are that much more complex. If GE will fix it under warranty, good for you! If not, go with the simplest things first. AppliancePartsPros and TH-cam videos are your friend. Also the people on DoItYourself.com can be helpful (or at least they'll try).

  • @sagexaero
    @sagexaero 5 ปีที่แล้ว +13

    shoulda just upgraded the panel and went electric,gonna have to be upgrade anyway

    • @kamilkuzmicki1687
      @kamilkuzmicki1687 5 ปีที่แล้ว +4

      Upgrading the panel...
      yea expect a hefty price tag

    • @chefjamesmacinnis
      @chefjamesmacinnis 5 ปีที่แล้ว +11

      I have an electric dryer but my house has the gas line in the laundry room. My next one will be gas. Gas is almost half the cost if electricity

    • @anthonysmith9410
      @anthonysmith9410 5 ปีที่แล้ว +1

      Upgrade the panel .......new service with 100 amp...two family home...3500 plus

    • @markwarrington2788
      @markwarrington2788 5 ปีที่แล้ว +2

      Sure but Richard had the gas dryer in his van he was trying to off load. Had to talk them into that option :)

    • @anthonysmith9410
      @anthonysmith9410 5 ปีที่แล้ว +5

      Mark Warrington who in their right mind would use a electric dryer? If you dont have natural gas get propane.......

  • @venividivici4253
    @venividivici4253 4 ปีที่แล้ว +1

    Richard reaction was priceless. Just call a licensed electrician. Have him upgrade the electrical panel. Then have him install a dedicated 220V outlet for the dryer.

    • @iac4357
      @iac4357 4 ปีที่แล้ว +1

      Are you gonna pay the hefty cost to do that ?

  • @LightningCube
    @LightningCube 4 ปีที่แล้ว +1

    Nice 👍😄😁

  • @jaydaytoday3548
    @jaydaytoday3548 5 ปีที่แล้ว +2

    Everbody commenting on the flexible duck used. RELAX everything is going to be alright.

  • @onenikkione
    @onenikkione 4 ปีที่แล้ว

    What is the larger-dark-fitting attached to the yellow flex line? @ 7:23 (not the Union fitting in his hand) That fitting does NOT come with the flex gas line. Once I figure this out I am going to make a video as all "gas dryer installation" videos do not say what that fitting is. I purchased the brasscraft flex line but am unable to connect to our gas dryer (new 2020).

    • @onenikkione
      @onenikkione 4 ปีที่แล้ว

      laying on the dryer attached to the end of the flex line @ 7:23

    • @iLikeC00kieDough
      @iLikeC00kieDough 3 ปีที่แล้ว

      1/2"x3/8" coupling

  • @johnroberts9560
    @johnroberts9560 5 ปีที่แล้ว +5

    Hi TOH I'm your first thumbs up ! 👍☺

  • @curtismeyers9713
    @curtismeyers9713 4 ปีที่แล้ว +1

    Bad choice using foil hose

  • @R_A_3000
    @R_A_3000 3 ปีที่แล้ว

    A lot of people in this comment section must be sponsored by Rigid.

  • @elevate32767
    @elevate32767 3 ปีที่แล้ว

    the vent hose looks like a mickey mouse job

  • @Freestila
    @Freestila 4 ปีที่แล้ว

    First time hearing about a gas dryer. At least here in Germany / Europe they are allways electric, and nowadays with efficient heatpipes. But of course here we have 220/240 volt all the time on every outlet, so dryers can go on any outlet.

    • @iac4357
      @iac4357 4 ปีที่แล้ว +1

      Gas dryers cost about $100 more, but are more efficient/cheaper to run.

    • @n9wox
      @n9wox 4 ปีที่แล้ว +2

      Some states, including California, are starting to ban gas appliances for new construction because natural gas is a carbon-based fuel.

    • @stevesullivan9752
      @stevesullivan9752 3 ปีที่แล้ว +2

      @@n9wox *Commiefornia

  • @wayne69wayne69
    @wayne69wayne69 3 ปีที่แล้ว

    @This Old House How much does it cost for someone to do it??? I have in Atlanta,Ga...

  • @snicks50
    @snicks50 ปีที่แล้ว

    The drip leg is not up to code.

  • @aegisarboulange4780
    @aegisarboulange4780 5 ปีที่แล้ว +2

    1:16 Anyone guess just how old that breaker panel is?

    • @ripstick2217
      @ripstick2217 5 ปีที่แล้ว

      Likely not that old. Depending on how old the house is, it may not be original. I would think it was have fuses if it were older than say 50 or 60 years

    • @g36killer
      @g36killer 5 ปีที่แล้ว +2

      1980s? Maybe. It has breakers so i cant be that old.

    • @TheOtherBill
      @TheOtherBill 5 ปีที่แล้ว +3

      I-T-E became ITE Imperial sometime in the 60's. They used that name until purchased by BBC (now ASEA Brown Boveri) in 1976, so that box would be from sometimes in the 60's until 1976.

    • @ripstick2217
      @ripstick2217 5 ปีที่แล้ว

      TheOtherBill I had two rewatch that part two times to figure out where you saw the brand. Good eye!

    • @oambrosia
      @oambrosia 5 ปีที่แล้ว +1

      Not that old. My parents' house had a 30 amp service with glass fuses until the late 90's. No A/C and gas appliances made it perfectly workable.

  • @user-tc1jo9xz6z
    @user-tc1jo9xz6z 5 ปีที่แล้ว +1

    Хороший проект👍

  • @matthewwillis2389
    @matthewwillis2389 ปีที่แล้ว

    Just have to watch that your dryer won’t starve your furnace for gas

  • @Jsuttar
    @Jsuttar 3 ปีที่แล้ว

    Should not be using a flexible duct
    Should be rigid

  • @41magfan
    @41magfan 4 ปีที่แล้ว +1

    The drain line on the washer is way too high

  • @porkchop1343
    @porkchop1343 3 ปีที่แล้ว

    Knowing how crooked I I am I would hook the gas line to other family’s line..

  • @ivanjpulidomora3373
    @ivanjpulidomora3373 5 ปีที่แล้ว +1

    What min did he hook up to the main line

  • @jessesan2003
    @jessesan2003 3 ปีที่แล้ว

    Plumbers putty, now pipe dope.

  • @samsngdevice5103
    @samsngdevice5103 4 ปีที่แล้ว +1

    That basement wall looks disgusting. Anyone want to know how to fix it?

    • @AxcelGamer97
      @AxcelGamer97 4 ปีที่แล้ว +1

      Probably power wash it and then paint it.

    • @R_A_3000
      @R_A_3000 3 ปีที่แล้ว

      You can cement finish the wall.

    • @stevesullivan9752
      @stevesullivan9752 3 ปีที่แล้ว

      Sell the house?

  • @Photon3d
    @Photon3d 5 ปีที่แล้ว +1

    I didn't even know that thing exists. :D

    • @robb9702
      @robb9702 5 ปีที่แล้ว

      This has got to be the clueless couple I've scene on TOH. She's goofier than goofy and he's dumber than dumber.

    • @stevesullivan9752
      @stevesullivan9752 3 ปีที่แล้ว

      @@robb9702 Goofy? I'm guessing you don't have a mirror Robert?

  • @Tom-se9yw
    @Tom-se9yw 5 ปีที่แล้ว +31

    Absolutely shocking how grown men have no mechanical ability

    • @Fkidd702
      @Fkidd702 5 ปีที่แล้ว +1

      Right 😂

    • @RoastBeefSandwich
      @RoastBeefSandwich 5 ปีที่แล้ว +4

      We all have different gifts and talents.

    • @spikefivefivefive
      @spikefivefivefive 5 ปีที่แล้ว +3

      Any more shocking than women who can't sew, cook, clean, etc.?

    • @Mikeofindy
      @Mikeofindy 10 หลายเดือนก่อน +1

      Just think how special you wouldn’t feel about yourself if all men were as capable as you think you are. I do hvac repair and love that a large portion of the population have other skills than mechanical. More $$ for me.

    • @JimDean002
      @JimDean002 8 หลายเดือนก่อน

      I think he's talking about people who can't even do the basics. Especially with TH-cam being available. There's pretty much nothing I won't try if I can find enough instructions on it.
      ​@@Mikeofindy

  • @eddiel2531
    @eddiel2531 4 ปีที่แล้ว

    Do u need pipe dope for flex gas connect?

    • @jakemanwhonneedscookies
      @jakemanwhonneedscookies 3 ปีที่แล้ว

      Teflon tape

    • @Embermist69
      @Embermist69 3 ปีที่แล้ว

      @@jakemanwhonneedscookies rated for gas, I think it's yellow compared to regular white for water.

    • @jessesan2003
      @jessesan2003 3 ปีที่แล้ว

      What happened to plumbers putty? 🤣

  • @markallan9050
    @markallan9050 4 ปีที่แล้ว +2

    The plastic pipe on the vent doesnt meet code where I live. I wouldve hard piped it in actual tin.

  • @saulgoodman2018
    @saulgoodman2018 5 ปีที่แล้ว

    Why did he use the farthest outlet away from the window?

    • @joeblack4137
      @joeblack4137 5 ปีที่แล้ว

      Trevor Phillips had an old house like that with 100amps service. All the outlets were in 3 20amp breakers so if I had to guess plugging into the closet one may of popped the breaker due to over load. Had to play the what you wanna run where game all the time just like she said with ac or hair dryer.

    • @RoastBeefSandwich
      @RoastBeefSandwich 4 ปีที่แล้ว

      I was thinking it may be because it's a duplex and that other outlet may be on the other unit's meter. Either that or perhaps the closer outlet is on the same circuit as their A/C or some other high-drain appliance.

  • @aaryavsandal9382
    @aaryavsandal9382 5 ปีที่แล้ว

    Hey

  • @Kauppamopo
    @Kauppamopo 3 ปีที่แล้ว

    so they cant dry clothes by hanging them?

    • @stevesullivan9752
      @stevesullivan9752 3 ปีที่แล้ว

      No. Let me guess... you have an outhouse?

    • @Kauppamopo
      @Kauppamopo 2 ปีที่แล้ว +2

      @@stevesullivan9752 no but we still dry our clothes by hanging lmao its almost free

  • @DragonBuilds
    @DragonBuilds 5 ปีที่แล้ว +1

    Gas!

  • @sulkijatarra
    @sulkijatarra 5 ปีที่แล้ว

    Are heat pump dryers common in the US?

    • @oambrosia
      @oambrosia 5 ปีที่แล้ว

      I'm not sure I've ever seen one at a typical appliance store. Cost/benefit just isn't there I guess.

    • @sulkijatarra
      @sulkijatarra 5 ปีที่แล้ว

      @@oambrosia In Europe pretty much all of them are using heat pump technology.

    • @oambrosia
      @oambrosia 5 ปีที่แล้ว

      @@sulkijatarra Yeah, I can see a heat pump being more efficient than conventional (read: old) tech. But energy is relatively cheap in the US making the additional cost less appealing.

    • @RoastBeefSandwich
      @RoastBeefSandwich 5 ปีที่แล้ว

      @@sulkijatarra energy is much more expensive in Europe.

    • @n9wox
      @n9wox 4 ปีที่แล้ว

      No.

  • @Guardducks
    @Guardducks 5 ปีที่แล้ว

    Richard did you tell the home owner, now remember to clean that vent tube every two months because lint is going to gather at the back of the dryer in the tube ?

  • @samsngdevice5103
    @samsngdevice5103 4 ปีที่แล้ว +1

    She goes to the laundromat.

  • @keykeyinvests3708
    @keykeyinvests3708 3 ปีที่แล้ว

    Do you have any recommendations of licensed professionals in the Baltimore MD area, to do a walk through of my home we would love to know if we have the necessary pipes in our house and which should we install, a gas or electric washer and dryer?

  • @HScorching
    @HScorching 5 ปีที่แล้ว

    I didn't even know gas dryers even existed. These seem harder to install. Usually, most retailers include the installation when purchasing a new washer and dryer. I wonder if they would include it as well for gas dryers.

    • @oambrosia
      @oambrosia 5 ปีที่แล้ว

      They include installation as far as the flex-line lookup. Anything more they won't touch. Gas dryers are awesome for the reasons mentioned; more power and gas is cheap compared to electricity.

    • @n9wox
      @n9wox 4 ปีที่แล้ว +1

      Drying time for gas dryers is much faster than electric. Cycle time for my gas dryer is about the same as my top-load washing machine, which means that the dryer doesn't slow down the wash/dry process.

    • @stevesullivan9752
      @stevesullivan9752 3 ปีที่แล้ว

      Most people are buying a new gas dryer to replace the original. Simple to hook up. Shut off the gas valve, remove old dryer. Hook line to new dryer, turn on gas valve.

  • @jonathancollins6190
    @jonathancollins6190 5 ปีที่แล้ว

    That flex hose for the venting, soundings like a call to the Fire dept is commng soon

  • @_______DR_______
    @_______DR_______ 5 ปีที่แล้ว +3

    Wow, you're really allowed to use such flimsy ducting for combustion gas in the US? Mental 😂

  • @YoureASquidYoureAKid
    @YoureASquidYoureAKid 5 ปีที่แล้ว

    Is that really just plywood for the window? No insulation or glass?

  • @omzig18
    @omzig18 5 ปีที่แล้ว

    I have a had dryer collecting dust anyone want it?