REFRIGERATION COMPRESSOR VALVE PLATE, HOW TO KNOW IT IS BROKEN? | REEFER CONTAINER

แชร์
ฝัง
  • เผยแพร่เมื่อ 6 ก.ย. 2024
  • Here is the proper way on how to diagnose the condition of a refrigeration system if you have a broken valve plate into your compressor.
    I hope this simple video will help you a lot esp for those who haven't yet experienced on how to replace the same kind of system.
    #containership #electrician #eto #seafarer #seaman #generator #jake #refrigeration #reefer #refrigerated #compressor

ความคิดเห็น • 147

  • @andrewschaefer8863
    @andrewschaefer8863 2 ปีที่แล้ว +24

    A common cause of broken valve plates is you are getting liquid refrigerant back to the compressor. I know you are a busy man on that ship but i would try and diagnose the root cause of the broken valve plate that way it will stop happening. Also, I would really recommend pulling that compressor into a vacuum after you had it open to atmosphere. If that compressor has P.O.E oil in it and air gets into it you can start to form acid and it will break down the motor windings. I know you are a busy man on that ship and im not trying to sound snood. Just lending a few tips from a person who works on refrigeration equipment for a living. I really enjoy your videos keep up the good work!

    • @PureMetalRider
      @PureMetalRider 2 ปีที่แล้ว +3

      I was thinking the same thing. Pulling a vacuum also ensures no moisture makes it to the expansion device and causing yet another problem.

    • @LaserUbermensch
      @LaserUbermensch 2 ปีที่แล้ว +1

      I did some digging on starcool. They use r290 which is propane, so its legal (if not safe) to vent to atmosphere. They also use polyolester oil, which is hygroscopic. I'd pull a vacuum before I charged it just to remove any water vapor.

    • @stueyknuxx
      @stueyknuxx 2 ปีที่แล้ว +2

      @@LaserUbermensch 6:38 in video, sticker clearly says under compressor R134a, ALWAYS pull a vacuum when you open the compressor to atmosphere, ALWAYS !

    • @psimarine399
      @psimarine399 ปีที่แล้ว

      World's best quality spare parts
      In lowest price contact me

    • @user-dk8jf6vw6x
      @user-dk8jf6vw6x ปีที่แล้ว

      your incorrect my guy - we use R-134a @@LaserUbermensch

  • @kabarotv6933
    @kabarotv6933 2 ปีที่แล้ว +17

    New videos from leckyjake every weekend is now part of my life. I always learn new things and thank you. More videos more knowledge to learn.

    • @leckyjake
      @leckyjake  2 ปีที่แล้ว +2

      Thank you kabaro

    • @markterante7489
      @markterante7489 2 ปีที่แล้ว

      OK lang Pala kahit hindi na mag vaccum?

    • @markterante7489
      @markterante7489 2 ปีที่แล้ว

      Master OK Lang Pala kahit hindi nag vaccum? Sana MA recognize

    • @leckyjake
      @leckyjake  2 ปีที่แล้ว +2

      Hi Mark, ideal practice is i vacuum ang system and palit filter drier. Pero yung diskarteng pogi is isolate the healthy system and then pag napalitan na open mo discharge side para yung pressure is enough par itulak palabas ng refrigerant ang hangin sa crankcase.

  • @walterdarvin9983
    @walterdarvin9983 2 ปีที่แล้ว +1

    It is better to recover the freon rather than releasing to atmosphere and carry out vacuum after boxing up compressor to be moisture free. Too many procedures, only one person, too many reefer containers. One after the other babies keeps crying, difficult to make systematically, can understand well good and informative video

  • @maxrobert2834
    @maxrobert2834 2 ปีที่แล้ว +1

    Can you make a video, how to fix Daikin Zestia, alarm E101 High Pressure Cut Out?
    Pressure of HPT reach 2400kpa on display panel same pressure on manifold gauge.

  • @user-dk8jf6vw6x
    @user-dk8jf6vw6x ปีที่แล้ว +1

    one tip - i wrap the econ pipe with a rag so the debris from the insulation doesn't fall on to the new gasket surface. the insulation gets brittle and flakes off when you remove the VP.

  • @NivagSwerdna
    @NivagSwerdna 2 ปีที่แล้ว +8

    It would be interesting to know what spares you carry (and how many)... I imagine being at sea without a spare would be a major issue or is there built in redundancy as well?

  • @cozzm0AU
    @cozzm0AU 2 ปีที่แล้ว +4

    Amazing that you have the spare part for this and that the system is serviceable like that.

    • @leckyjake
      @leckyjake  2 ปีที่แล้ว +1

      So lucky to have spare

  • @norlitomembrebe7577
    @norlitomembrebe7577 2 ปีที่แล้ว +5

    Good day sir! I just want to ask if it is ok to open the compressor with the system without vacuuming it? You opened the LP valve plate which, made the compressor exposed to air. Will not the pressure be affected by this? Thank you, sir.

  • @osmankaya9664
    @osmankaya9664 2 ปีที่แล้ว +2

    I learn something new in every video. Thank you Sir.
    I look forward to more videos from you. Plz keep safe.

  • @felixodhiambo6520
    @felixodhiambo6520 6 หลายเดือนก่อน

    Thanks Jake,i have learnt something

  • @0dbm
    @0dbm 2 ปีที่แล้ว +3

    I am fascinated at your level of knowledge both mechanical and electrical.
    Where was your formal training at or was it all on the job, thank aforesaid the videos

  • @marinongmarinero1731
    @marinongmarinero1731 2 ปีที่แล้ว

    He is the real deal. Actual troubleshooting that you are doing is giving me a much clearer view on what should I do if I am on yout shoes.

    • @leckyjake
      @leckyjake  2 ปีที่แล้ว

      Thank you very much

  • @davidtwumasi2684
    @davidtwumasi2684 5 หลายเดือนก่อน

    Great video
    Thanks for sharing 🎉🙏

  • @vishwanathghosh8422
    @vishwanathghosh8422 ปีที่แล้ว

    Bro! You should use gopro cam mounted on helmate and a head torch, so that you can work and shoot without inconvenience.

  • @aldrinempalmado1774
    @aldrinempalmado1774 2 ปีที่แล้ว

    Na experience q din dati sir ung mcraan ng valve plate, pero sa reefer machinery Ng provision.. tnx for sharing..👍👍

  • @cliveramsbotty6077
    @cliveramsbotty6077 2 ปีที่แล้ว

    guys on ships always amaze me, they can cobble up pretty much anything on earth

    • @leckyjake
      @leckyjake  2 ปีที่แล้ว

      Less spares that needs to be resourceful

  • @salemhunid9482
    @salemhunid9482 2 ปีที่แล้ว +1

    nice video, I hope that you will still doing videos about reefer containers because you're the best one in youtube who explain this topic

  • @nopatience1417
    @nopatience1417 2 ปีที่แล้ว

    You are excellent at your job and they lucky to have you,do you ever have a unit you couldn’t fix (no parts)what do you do then when you’re at sea

  • @kyryl5673
    @kyryl5673 ปีที่แล้ว

    Hi, Jake! In a such a case: LP v/v plate in doubt, there is in Menu can be performed Function test for the Compressor only (Pre Trip Inspection) and if it will Fail you can get Alarm: 840 - Valve Leaks. During investigation i do this action, it seems to me this one of rapid way. All the rest i do the same. Best regards and good luck!

    • @Anzarvitalbio
      @Anzarvitalbio ปีที่แล้ว

      Function test is only available in thermoking reefers, and pre trip inspection is not allowed in units with cargo inside, PTI TEST can be performed only when preparing reefer to enter service in PTI area with empty reefers.

  • @user-ex8qx2vr5v
    @user-ex8qx2vr5v 2 ปีที่แล้ว +2

    First of all you can easy hear difference of the sound of compressor with broken valves on valve plate, espacially on high frequency.

  • @legendoffrost8832
    @legendoffrost8832 2 ปีที่แล้ว +1

    As a hvac tech i can see many things wrong with the procedure. But I'm not faulting you lecky your not a full time hvac tech. You did what you had to do to get it running.

    • @roelanddejonghe4694
      @roelanddejonghe4694 2 ปีที่แล้ว

      The thing is on board it's hard to carry the vacuum pump & recupation device below deck. Or did you mean something else?

  • @proksalevente
    @proksalevente 2 ปีที่แล้ว +4

    How come you didn't pull a vacuum on the compressor, and didn't verify the correct charge amount after adding refrigerant?

    • @leckyjake
      @leckyjake  2 ปีที่แล้ว +5

      I have 268 refrigerated container onboard and 7 of them are malfunctioning.
      1. 2 Evap fan motor
      2. Shorted power cable
      3. Burn contactor
      4. Power card
      5. High pressure system
      6. This chilled cargo with broken valve plate
      I just need to fix all as fast as I can.

    • @venkatavala4284
      @venkatavala4284 2 ปีที่แล้ว

      @@leckyjake good job .. as EE to manage workload is great ..

    • @lexikate-04
      @lexikate-04 2 ปีที่แล้ว

      Sir ano po kalimitan dahilan kapag ka high pressure discharge alarm po...ano po solution..thank u po in advance

  • @user-gh8nu1bb4m
    @user-gh8nu1bb4m 6 หลายเดือนก่อน

    I have really enjoyed

  • @chriestsm4238
    @chriestsm4238 2 ปีที่แล้ว

    God Bless u lecky.... so valuable sharing.... thank you so so much
    .... 🙏🙏🙏

  • @WALKINGJOURNEY-eq9zd
    @WALKINGJOURNEY-eq9zd 3 หลายเดือนก่อน

    Soon maka sampa din same that work, actually that is my big dreams ummm

  • @r-ainjel4735
    @r-ainjel4735 2 ปีที่แล้ว

    Husay mo lec. Di ako naka experience ng ganyang trouble onboard. Malaking tulong ito sa ibang kabaro. Tuloy mo lang ginagawa mo on sharing your knowledge and being humble. Safe voyage lecky.
    Nkapaliran mo na ba Eto Balatico?

  • @wisetringmen2293
    @wisetringmen2293 2 ปีที่แล้ว

    Please, more about reefers. You are the best.

  • @GuellordMuleba
    @GuellordMuleba ปีที่แล้ว

    Very glad to see your video and I don't want to miss one of your video.

  • @BeenThrDunThat
    @BeenThrDunThat 2 ปีที่แล้ว +3

    It seems obvious now that it would be your responsibility to maintain the cooling systems on refrigerated units. But it didn't cross my mind originally.
    That would seem to imply that you have to do daily rounds to check on each unit? Or do they alert when in trouble? How many refrigerated containers are typical?

    • @leckyjake
      @leckyjake  2 ปีที่แล้ว +4

      Yup, the highest number I had was 1400 refrigerared containers. It is actually my main job onboard.

    • @BeenThrDunThat
      @BeenThrDunThat 2 ปีที่แล้ว

      @@leckyjake impressive!

    • @leckyjake
      @leckyjake  2 ปีที่แล้ว +1

      Thank you and Keepsafe always

    • @russ1669
      @russ1669 2 ปีที่แล้ว +1

      Yes it was an eye opener for me as well. I assumed you just maintained the ships systems. Does the company then charge the service fee to the owner of container or is this all part of the shipping cost?

    • @russ1669
      @russ1669 2 ปีที่แล้ว

      Sorry, I should add that I liked your video. Very informative and easy to understand

  • @VlogiOtSeregi
    @VlogiOtSeregi 2 ปีที่แล้ว

    Thank you! I`m work with reefer containers too and that's video was some new fore me and i think hapfull!

  • @s895s607
    @s895s607 2 ปีที่แล้ว

    I really like your videos,This video is very helpful, it's really good, thank you very much,

  • @ybbrito
    @ybbrito ปีที่แล้ว

    Good video, leckyjake. Please keep sharing this type of information about refrigeration system 🙌

  • @BrettWae
    @BrettWae ปีที่แล้ว +1

    Surprised you didn't pull a vacuum before open the system back up to the compressor? What caused the valves to fail? Could be a liquid slug?

  • @patricioaguayo9088
    @patricioaguayo9088 2 ปีที่แล้ว

    Please post a video on pumping down the low side to replace filter drier, thank you sir.

  • @aslamkhan01
    @aslamkhan01 2 ปีที่แล้ว

    Thanks lecky for making informative video

  • @tjairicciardi9747
    @tjairicciardi9747 2 ปีที่แล้ว +1

    very cool video, always wanted to understand how the compressor worked.

  • @thetpaingoo3076
    @thetpaingoo3076 2 ปีที่แล้ว

    Good to watch your video, Sir.

  • @venkatavala4284
    @venkatavala4284 2 ปีที่แล้ว

    Good one ... thank you for valuable tips

  • @damnitdang
    @damnitdang 2 ปีที่แล้ว

    So if low side doesn't pull a vacuum when it's low sided.. most likely valve is broken in the head... cus it's suppose to pull a vacuum once you front seat the low side right?

  • @icehammericehammer5746
    @icehammericehammer5746 4 หลายเดือนก่อน

    Thank you

  • @xintongma2976
    @xintongma2976 10 หลายเดือนก่อน

    谢谢哥

  • @sriparameshwariharvestersu8148
    @sriparameshwariharvestersu8148 2 ปีที่แล้ว +1

    Bro make a video, how power is generated in ship if generated produced the power means how many litre of diesel consumes for one day

  • @harrynunez1292
    @harrynunez1292 ปีที่แล้ว

    It is possible to make pre trip inspection so that the alarm for valve plate defective will appear? And other way to ensure the valve plate is damage.

    • @Anzarvitalbio
      @Anzarvitalbio ปีที่แล้ว

      PTI TEST is not allowed in units with cargo inside the reefer

  • @brianwachtel7512
    @brianwachtel7512 2 ปีที่แล้ว

    Good videos man. Very informative and helpful. Keep up the good work.

  • @timorleste1323
    @timorleste1323 2 ปีที่แล้ว

    Beginner guide pls sir.. if posible all kinds of trouble shooting for reefer. Im interested to learn this kind of job.

  • @geenumaxy9370
    @geenumaxy9370 ปีที่แล้ว

    great video

  • @danielduplessis1582
    @danielduplessis1582 10 หลายเดือนก่อน

    Did you vacuum the compressor after installing the valve plate???

  • @benzblogsVlogs
    @benzblogsVlogs 2 ปีที่แล้ว

    Magaling sir bless u po

  • @user-lp8dq9sd6b
    @user-lp8dq9sd6b 23 วันที่ผ่านมา

    ❤tnx sir

  • @joemarherrera7692
    @joemarherrera7692 9 หลายเดือนก่อน

    Sir, ask ko lang insufficient cooling Ang reefer container freezer. Ang reading sa suction line almost vacuuming na. At reading Naman sa suction modulation valve ay same almost vacuuming. May posibilidad ba na Ang problema ay nasa suction modulation valve. Hanggang -10 lang sia ayaw ng bumaba Ang temperature. Ang high side pressure ay 250 to 300 psi .

  • @DavidReyes-fd3qz
    @DavidReyes-fd3qz 2 ปีที่แล้ว

    Very good. No need to vacuum?

  • @jeffrimanurung6757
    @jeffrimanurung6757 2 ปีที่แล้ว

    Tq sir .. sehat selalu

  • @vishalkumarmaurya3958
    @vishalkumarmaurya3958 2 ปีที่แล้ว

    we always get to learn something new 😊😊

  • @eagletek1
    @eagletek1 2 ปีที่แล้ว

    Great job 👌

  • @johnnycash4034
    @johnnycash4034 2 ปีที่แล้ว +1

    I use to do those containers in port.
    These compressors are shat. I use to be really good at this. Now I've forgotten most of it 😂

    • @leckyjake
      @leckyjake  2 ปีที่แล้ว +1

      Knowledge will always be there. Thank you for the support

  • @tahirqamar6685
    @tahirqamar6685 2 ปีที่แล้ว

    Really I learned, thanks

  • @srivatsavmattaparthi4915
    @srivatsavmattaparthi4915 2 ปีที่แล้ว +1

    Sir what if the compressor is the problem. Will you have to replace with brand new compressor? I heard that these compressors are too heavy to lift (reach compressor weight is around 40kg-45kg)

    • @leckyjake
      @leckyjake  2 ปีที่แล้ว +1

      Yup, we need to replace it. Savong cargo is our main priority

  • @MikeF1189
    @MikeF1189 2 ปีที่แล้ว

    I like this video without background music.

  • @mbwanaali6278
    @mbwanaali6278 2 ปีที่แล้ว

    Nice

    • @leckyjake
      @leckyjake  2 ปีที่แล้ว

      👍👍👍👍

  • @tukyaing7334
    @tukyaing7334 2 ปีที่แล้ว

    Lecky can you please point out the symptoms of the defective HP valve plate too?

    • @willrobbinson1
      @willrobbinson1 2 ปีที่แล้ว

      no pump pressure on out side

    • @andrewschaefer8863
      @andrewschaefer8863 2 ปีที่แล้ว

      @@willrobbinson1 you would not be building any discharge pressure. Your suction pressure and discharge pressure would be very close to each other. Also you would be possibly experiencing oil loss in your compressor.

    • @user-dk8jf6vw6x
      @user-dk8jf6vw6x ปีที่แล้ว

      I have not seen this very often

  • @armandschuijren1213
    @armandschuijren1213 2 ปีที่แล้ว

    You have to pull vacuum here is now air and moisture in the system

  • @Korn-7005
    @Korn-7005 2 ปีที่แล้ว

    Sir leckyjake what is the use and purpose of condenser sight glass in refrigeration??? Thank you 😊

  • @syedbasheer8210
    @syedbasheer8210 2 ปีที่แล้ว

    Nice job bro🤩

  • @tricitiesair
    @tricitiesair 2 ปีที่แล้ว

    How does propane work in low temp refrigeration?
    It is one of the possible replacements for R410a over here.

    • @hvactechpr7872
      @hvactechpr7872 2 ปีที่แล้ว

      Mostly its gonna run on smaller stuff for now (its capped at 6onz per circuit)... Lets see what time brings

  • @Mark_The_Mayven
    @Mark_The_Mayven 2 ปีที่แล้ว

    Good job as usual!!

    • @leckyjake
      @leckyjake  2 ปีที่แล้ว +1

      Thank you so much

  • @waiyanaung8644
    @waiyanaung8644 2 ปีที่แล้ว

    Thank you sir!

  • @maheshkumarlotlapally6043
    @maheshkumarlotlapally6043 2 ปีที่แล้ว

    How much pressure required for Daikin reefer container. R134a gas inlet pressure?

  • @vigneshkrvd
    @vigneshkrvd 2 ปีที่แล้ว +1

    Thank u 🙏

  • @user-ko8zv6kj3m
    @user-ko8zv6kj3m 2 ปีที่แล้ว

    Cool video 👍

  • @hasnaendaila5244
    @hasnaendaila5244 ปีที่แล้ว

    Sir Jake High pressure valve plate nakapag palit narin po kayo? paano po procedure salamat po

  • @muhammadrizwanjan1984
    @muhammadrizwanjan1984 ปีที่แล้ว

    Can you share the reason, cause this broken.

  • @mithileshramteke3882
    @mithileshramteke3882 2 ปีที่แล้ว

    Thank you so much

  • @MrDonNilantha
    @MrDonNilantha 2 ปีที่แล้ว

    👍

  • @ractvvlogs1334
    @ractvvlogs1334 2 ปีที่แล้ว

    Sir tanong ko Lang po saan pba pwd mag aral Ng refeer container technician

  • @chrisj2848
    @chrisj2848 2 ปีที่แล้ว

    Are refrigerated containers powered off of the ships power or are does each container have its own generator like on a truck?

    • @leckyjake
      @leckyjake  2 ปีที่แล้ว +1

      They are plug in on the ships power, 440V 3 phase. We have available of 900 sockets.

    • @chrisj2848
      @chrisj2848 2 ปีที่แล้ว

      @@leckyjake Thanks! Great videos 👍

  • @evkapoc
    @evkapoc ปีที่แล้ว +1

    Kur ekologija ( kas išsiurbs šaltnešį iš kompresoriaus prieš remotą) , išvakuumuoti kompresorių taip pat pamiršo :D

    • @Laba-Diena
      @Laba-Diena หลายเดือนก่อน

      Zinok esu mates kaip jie dieba ten. Ten 2 Mones priziuri 500 -1000 reeferiu ten nelabai turi jie laiko :)

  • @michaelladue5655
    @michaelladue5655 2 ปีที่แล้ว

    Wow there is gong to be a ton of contamination In that system. They must have filters on the pressure side?

    • @leckyjake
      @leckyjake  2 ปีที่แล้ว +1

      Yup a filter drier is fitted at the discharge side

    • @michaelladue5655
      @michaelladue5655 2 ปีที่แล้ว

      @@leckyjake thanks you for your videos, I have wondered for years about refrigeration on container ships.

  • @unwindtv8080
    @unwindtv8080 ปีที่แล้ว +1

    boss tanong lng..ano kaya problema cold storage namin. very low suction pressure or nag vacuum wla nmn leak..medyo marami na rin kaming nakarga na freon.. nag vacuum parin. ano kaya problema boss.. sana matulungan nyo kami boss.

    • @leckyjake
      @leckyjake  ปีที่แล้ว

      kung nag vavacuum at tumataas ang discharge pressure pwede mong i check ang filter drier. compare mo ang inlet at outlet ng filter drier kung equal ang temperature, kapag equal then ok anfg fd mo pero pag unequal then need mo palitan.
      in case ok ang FD mo then open mo evaporator mo and check kung nag yeyelo ang evaporator at txv kung may yelo maaring hindi nagbubukas ang txv mo, or kung may solenoid siya before txv baka di nagbubukas yung solenoid valve mo

    • @unwindtv8080
      @unwindtv8080 ปีที่แล้ว

      @@leckyjake hindi rin tumataas ang discharge pressure boss ..ang solenoid ngbubukas nmn kasi may konting yelo sa output ng txv..mayron din po syang sub cooler boos.. pwd bang masira ang accumulator boss.?

  • @ushansandeepa748
    @ushansandeepa748 2 ปีที่แล้ว

    👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍super video

  • @izuanwan8275
    @izuanwan8275 2 ปีที่แล้ว

    Hi Leckyjake, may i know did we need to vacuum the circuit once valve plate replaced done?

    • @leckyjake
      @leckyjake  2 ปีที่แล้ว

      You have to if you missed to isolate the system and sometimes need to change the filter drier as well as to my case I completely isolated the system just before I open the head and purge completely the system.

  • @kj3854
    @kj3854 2 ปีที่แล้ว

    SO THE ETO DOES THE REFRIGERATION WORK ALSO?

  • @zakihodekar7485
    @zakihodekar7485 2 ปีที่แล้ว

    Sir i am also doing ETO. My dream is to get in the MAERSK company . Plzzzz sir can u do anything ❤️

    • @og6078
      @og6078 2 ปีที่แล้ว

      Just get a job on any container vessel first then build experince. Then apply to maerks is not that hard.

    • @og6078
      @og6078 2 ปีที่แล้ว

      And maerks is not the best paying company.

  • @JustFun-jk4dw
    @JustFun-jk4dw 2 ปีที่แล้ว

    Sir mg kano sahod nang assistant reefer

  • @sriparameshwariharvestersu8148
    @sriparameshwariharvestersu8148 2 ปีที่แล้ว

    If any motor winding failure means what u can do bro

    • @leckyjake
      @leckyjake  2 ปีที่แล้ว +1

      Replace it with new one

    • @Jamie-po9zk
      @Jamie-po9zk 2 ปีที่แล้ว

      @@leckyjake you have spare compressor on board as well?

    • @srivatsavmattaparthi4915
      @srivatsavmattaparthi4915 2 ปีที่แล้ว

      @@Jamie-po9zk of course they will have

  • @MrDonNilantha
    @MrDonNilantha 2 ปีที่แล้ว

    👆

  • @bradgeary3467
    @bradgeary3467 2 ปีที่แล้ว

    no vacuum????

  • @otepmar5244
    @otepmar5244 ปีที่แล้ว

    You did not evacuate the air off the compressor

  • @macbong01
    @macbong01 2 ปีที่แล้ว

    but where is the leak ?

  • @toyinorodare4072
    @toyinorodare4072 2 ปีที่แล้ว

    I imagine that the valve plate got broken by Refrigerant floodback?

  • @mrroadrash1820
    @mrroadrash1820 2 ปีที่แล้ว +1

    Those pistons didn’t look very happy

  • @randomrefrigeration4564
    @randomrefrigeration4564 ปีที่แล้ว

    He is not worried about a vacuum that will be the next guys problem when the compressor shorts out
    Remember he only needs it to work until they make port kinda of crappy is what it is
    I imagine there are shipboard reefer techs that curse guys like this

  • @infinixdiplomat5988
    @infinixdiplomat5988 ปีที่แล้ว

    Pinoy kba sr

  • @amilcarramirez7298
    @amilcarramirez7298 2 ปีที่แล้ว

    Hahaha wrong method 🤦‍♂️🤦‍♂️🤦‍♂️🤦‍♂️