Wiring of the Distribution Board From Energy Meter to the Consumer Unit
ฝัง
- เผยแพร่เมื่อ 9 ต.ค. 2020
- #Wiring_diagram_for_electrical_panel ,
#Connection_of_an_electrical_panel_of_a_house
#single-phase_electrical_panel
Wiring diagram for electrical panel with single-phase meter and household
appliances
single diagram for electrical panel with single-phase meter and household appliances
single phase meter wiring diagram | energy meter | energy meter connection by earthbondhon
single phase electricity explained. In this video we learn electrical engineering basics by learning single phase meter wiring diagram. How electricity reaches our homes from the power station, transformer, transmission lines, distribution cables, service head and main fuse, electricity meter, main isolation switch, residual current device and circuit breaker. Electricity basics, how electricity works
single phase DB wiring diagram single phase meter wiring diagram energy meter
MCB connection input and output real ।। mcb connection
How to MCB Box connection ।। distribution MCB box connection ।। ELCB/RCCB, DP/SP MCB connection
ELCB/RCCB ।। How to work ELCB/RCCB ।। ELCB/RCCB Connection ।। ELCB/RCCB VS MCD
--------------------------------------------------------
#Electrical installation of a kitchen with protection
#Installation électrique d'une cuisine avec protection
#Электромонтаж кухни с защитой
التمديدات #الكهربائية للمطبخ مع الحماية
-----------------------------------------------------------------------------
#single #Electric_Meter
#Wiring_diagram_for_electrical_panel ,
#Connection_of_an_electrical_panel_of_a_house
#single-phase_electrical_panel
#Electrical_installation_of_a_kitchen_with_protection
#Installation_électrique_d'une_cuisine_avec_protection
التمديدات_الكهربائية_للمطبخ_مع_الحماية#
--------------------------------------------------------------------------
Wiring diagram for electrical panel with single-phase meter and household
appliances
single diagram for electrical panel with single-phase meter and household appliances
single phase meter wiring diagram | energy meter | energy meter connection by earthbondhon
single phase electricity explained. In this video we learn electrical engineering basics by learning single phase meter wiring diagram. How electricity reaches our homes from the power station, transformer, transmission lines, distribution cables, service head and main fuse, electricity meter, main isolation switch, residual current device and circuit breaker. Electricity basics, how electricity works
single phase DB wiring diagram single phase meter wiring diagram energy meter
MCB connection input and output real ।। mcb connection
How to MCB Box connection ।। distribution MCB box connection ।। ELCB/RCCB, DP/SP MCB connection
ELCB/RCCB ।। How to work ELCB/RCCB ।। ELCB/RCCB Connection ।। ELCB/RCCB VS MCD
--------------------------------------------------------
#Power_Supply_Network #Electric_Meter #Differential_circuit_breaker #Branche_Circuit_Breker #Electric_cable #Earth_Break_Bar #Earth_stake #Neutral_terminal_block #Earth_Terminal_Block #Fuse_block #general_Electricity #Building_Electricity #installation_diagram_of_the_electrical_panel_of_a_house #Circuit_breaker #Differential_breaker #Branch_breaker
#Kitchen_installation #Building_installation #electricity_building #electric_cable #grounding #electrical_panel #cable_section #assembly_back_and_forth #single_ignition_assembly #electrical_assembly #undernourished #remote control #movement_detector #electrical_diy #Automation
-----------------------------------------------------------------------------
#Автоматический_выключатель #Дифференциальный_выключатель #Автоматический_выключатель_ответвления #Установка_кухни #Монтаж_здания #электричество_здание #электрический_кабель #заземление #электрическая_панель #сечение_кабеля #сборка_туда_и_обратно #единый_узел_зажигания #электрическая_сборка #недоедающий #Дистанционное_управление #детектор_движения #электрические_поделки #Автоматизация
---------------------------------------------------------------------
#Disjoncteurde_protection #Disjoncteur_différentiel #Disjoncteur_divisionnaire #Installation_cuisine #Installation_batiment #electricité_batiment #cable_electrique #mise_a_terre #tableau_electrique #section_de_cable #montage_va_et_vien #montage_simple_allumage #montage_electrique #minutrie #telerupteur #detecteur_de_mouvement #bricolage_electrique #domotique
-----------------------------------------------------------------
#قاطع_دائرة #قاطع_الدائرة_التفاضلية #قاطع_الدائرة_الفرعية #تركيب_المطبخ #تركيب_المبنى #كهرباء_العمارة #سلك_كهربائي #التأريض #لوحة_كهربائية #الكابلات #التركيب_الكهربائي_ذهابًا_وإيابًا #التركيب_الكهربائي_الاشتعال_الفردي #التركيب_الكهربائي #جهاز_التحكم #كاشف_الحركة #أتمتة - วิทยาศาสตร์และเทคโนโลยี
Excellent ! for basic fundamental understanding ? Very nice ! Thank you 🙏
(I'm in the UK !!) It's interesting to see how other countries wire there systems - on the 'upstream' RCD, we'd use a time delay unit in the UK. I notice that the KW meter differs from ours, the outside connections are always live for a single phase meter!
concisely presentations 👍👍!
सर जी आपका काम बहुत अच्छा है मुझे बहुत अच्छा लगा tunku you sir ji
شرح ممتاز و مفصل تحياتي استاذي الكريم نتمنى فيديوهات اخرى جزاك الله خيرا
فتيحةبنت ݣدرحشش يتحرر سدبأ حشش يتحرر يتحرر سدبأ حشش 🤦🏻♀️🤲🏻😭💕
❤
In Ireland, all ceiling lighting uses 1.5mm twin + earth (in case of metal/conductive fittings), all regular sockets use 2.5mm twin + earth.
However, the major white goods, fridge, freezer, washer, dryer etc., must first run to an isolator switch nearby as well as their own breaker back at the consumer panel.
Additionally, Electric ovens require 6.0mm to isolator switch + breaker - while electric showers require 10.0mm and a ceiling mounted pull chord isolator within the shower room area, or, a wall mounted isolator is permitted outside the shower room + breaker.
À
You are right
Спасиба
so what do you think about the above information? is it not right or incomplete?
informative ...Thanks your Video
In the Netherlands we dont have have so much breakers per Earthleak switch!Because the false current will be to much with so much breakers.
That current is from condensers in appliances like a dishwasher etc.And that can only be 30 mA max!.So the normal consumer unit would be a main switch, 20 breakers,5 earthleakswitches.
This has only one!!
جميل جدا جدا جزاكم الله خيرا والله يحفظكم ويحميكم و ويسعدكم دنيا وآخره يارب العالمين
what? Bro what is that? we do not read or understand arabic, try in English, please!!
Υπάρχουν λάθη στο κύκλωμα.
10Α - 1.5 mm
16A - 2.5mm
20A - 4mm
25A - 6mm
32A - 10mm
63A - 16mm
......
Estoy completamente de acuerdo contigo
Hampos 7 συμφωνώ μαζί σου και με έχουν μπερδέψει τόσα που έχω ακούσει σε βαθμό να μην ξέρω αν μπορώ να πιστέψω ακόμα και εμένα...τι να κάνω δεν ξέρω
@@dkaloupis75 όχι δεν χρειάζεται να σε μπερδεύουν ο καθένας ανεβάζει ότι θέλει. Υπάρχουν κ ελληνικά κανάλια που είναι αξιόπιστα. Εγώ έτυχα κ έπεσα σε αυτό το βίντεο κ λέω ούτε τα βασικά δεν δείχνουν σωστά.
Exist 13A breaker for 1.5mm
謝謝您的分享
Really good 👍
GOOD MY FRIEND
Love this bro ❤
The split system needs a 4-mile wire with a 32-amp circuit
Very understandable. I am not an electrician but with this electrical diagram it make it ease to do a DIY.
😅 don’t try tho
that's not all you need to understand. so much to consider aside from that.
@@christianbustamante2526 like what?
@@sarbull wire gauge + breaker pairing in accordance to expected maximum load is one of those things. The pairings here are done in accordance with how the stars line up, not according to expected maximum power load.
Furthermore, if you wanna diy it, it sure as hell won't be as easy as drawing some diagrams on a screen. This is a typical european design so that kind of requires a lot of water and a rotary hammer drill, plus some plaster and some elbow grease. Shit ain't as easy as it seems.
Not really!! You shoud have proper understanding or education on that. do not try with out a proper knowledge, bro!!
What software cad are you using
Thank you so much
Не согласен, для автомата 16А провод должен быть не меньше 2.5 мм2, для 32А 4 мм2
Да тут вообще вся схема неправильная.Кто столько автоматов ставит на УЗО и тем более на ДифАвтомат?..Больше двух на Узо не ставят.
جميل جدا ورائع لتعليم الكهرباء
عمله خاطىء
Veri good, B.R
مع وجود محايد مشترك مع GFCI، عند حدوث خطأ تسرب، لا يمكن تحديد الخطأ وتحييده. يجب استخدام قاطع الدائرة الفرعية الذي يقطع الطور والمحايد معًا، أو استخدام 2 GFCI لحل المشكلة
In Ghana here when the cables from the supply unit come, they enter the meter in the order of live, neutral, neutral then live
Important ❤
Great!
👌
Nice Video Animation but no Names for the stuffs ,. That made it suck but anyway welldone👍🏼
Show de bola
Major omission with this representation, it doesn't show any earth bonding or cross bonding of water and gas pipes where applicable, otherwise a good representation.
Super
Quick question, If i have
1 × 30A stove circuit breaker
1 × 40A circuit breaker for the inverter inlet
2 × 15A circuit breakers foe the plugs
2 × 5A circuit breaker for the lights, what should be the current rating for my Main circuit Breaker, will i be fine with a double pole 63A MCB?
Taping cables for the electrical fence
Here in tunisia we use 6 mm to 32 A , 4 mm to 20 A ,2.5 mm to 16 A and 1.5 mm to 10 A
16 mm used to 63 A
Okay that must be french system or old Arabian?
You right Sir and every country use this method.(Sorry for English)
Let me see if I understand this , is there 2 hot wires leading to each unit?
what software do we use to make diagrams
you do not need any, just try your hand pencil and paper. or if you really wanted to know you have to have proper class to attend at least 2 months or for all the electrical wiring you shoud attend the college on the that subject, may tells you 2 yeras or more full time or more parttime. try your local college for more information in this issues.
good video
Merci infiniment
Thanks
na zásuvku 16A- 1,5mm2🤢🤢😱😱,na 20A-2,5 NE.Na 16A se dává 2,5mm2 a na 20A 4mm2
Excellent .. Many thanks.
I encourage you
with something like this you definitely need the fire brigade, a 10A C-curve circuit breaker trips at a short circuit current 5-10 times the protection current written on the circuit breaker, this means that a 10A will trip at a short circuit 100A+ hazard factor 50% 150A with that 1.5mm conductor, the firemen are sure to come, that TT-type grounding excludes such things, those differentials are RCBO or RCCB type A or AC type?
for an 1800 2500w air conditioner C20 is exaggerated 230V x 20A=4600w let's not even talk about selectivity
So you mean that we should use a 2.5mm for the 10A and 16A CBs?
@@Ahmed_RS. maybe is better to use a B6 instead C10. You need to break at lower current not to increase wire section.
i write the same comment but i see yours and i delete, in rezidential home only curve B circuit breaker
@@Ahmed_RS. no, I want to say that a 2.5mm/2 conductor must be used on socket circuits protected with CB B16, a 1.5mm/2 conductor for lighting circuits respectively, intercom, blinds and other weaker consumers, protected with B10 respectively B6 ,B2, there is no way to install a fuse higher than 16A on the dedicated circuit in residential, neither for the washing machine nor for the boiler or the induction hob, unless the consumer exceeds a consumption of 4000w and the induction hob, let's say, has a consumption of 8kw but surely it is three-phase or two-phase and that means that you can put a CB 2xB16 for the stove, for the roll which has a maximum consumption of 150w, he put a C16 fuse, WTF, likewise the refrigerator does not have a consumption higher than 500-800w B16 it is enough to understand why 2.5mm and not 1.5mm, measure a 2.5mm conductor with a tape measure and you will see that it is not 2.5mm, the diameter of the conductor is given in square millimeters
@@kentfyeratanye378 and necessarily selectivity, not that mess
سلام تشکر درود وسپاسگزار وهزاران 👍...👍...لطفا در صورت امکان یک مدار سیمکشی کامل به همین صورت زحمت بکشین...این شاهکار شما واقعا بسیار بینظیر است
وبسیار شبیه به سیمکشی کامل ودقیقی از تمام خودروهای جهان است با اختلاف بسیار کمی در اضافه کردن تعدادی قطعات بیشتر
👌👌👌👌👌🙏🙏🙏🌷🌷🌷
لطفا حتما حتما نمودار سیم کشی کاملی از خودروها بهمین صورت اقدام نمایید...متشکرم.....👌👌👌👌🙏🙏🙏🌷🌷🌷
output and Input bottom said are top said connection to bracker ?
Bro can we use different size wire in same circuit for example
2.5 sq mm wire for phase
1.5 sq mm wire for neutral
1 sq mm wire for earth
Nice
in my country algeria we use only one main circuits breaker and we dont connect any load directly except the lamps, we use switches to connect them
Mnink khoya
@@madjidcasio4617 men souk ahras, mais je suis pas un électricien, diplomé en électromécanique ctt
are you an electrician or just...?
from which country this diagram from in south Africa you can burn the house with diagram ...what is the voltage supply from the meter reading???
schema top,merci .........../
👍👍👍
УЖЕ НА ВВОДЕ, ДОПУЩЕНА ОШИБКА ПРИ РАСКЛЮЧЕНИИ СИСТЕМЫ ЭЛЕКТРОСНАБЖЕНИЯ !!!!
Podia explicar porque existem dois disjuntores diferenciais em série. Um de 500 mA e outro de 30 mA?!
Se houver uma fuga de corrente de 40 mA num qualquer circuito, esse disjuntor de 30 mA dispara e abre o circuito, protegendo a instalação eléctrica.
Então o que é que está a fazer o disjuntor de 500 mA?!?! Esse nunca vai disparar porque o outro dispara primeiro.
Estarei a pensar bem ou não?! Aguardo sua resposta.
Muito obrigado.
Abraço de Portugal.
Nós que temos o idioma mais rico e mais bonito da face da terra infelizmente nossas dúvidas e perguntas eles não respondem. Triste né? Estou na cidade de Congonhas - Minas Gerais, Brasil.
Very nice work
Hello thanks for the vid. Can you pls let me know how much wire thickness needed for cooker unit. I am using a dp switch of 45A
6mm2 or 10mm2
The air conditioner we use a lot in the summer and most of the summer and some of the fall because our area has a high temperature and I see that you used a weak electrical thread
Интересный подход)) последовательное соединение провода 25мм2 и 16мм2 при разрыве на 60А предохраните. В чем смысл ? Тут два разных сечения. Зачем?
судя по всему 25мм это СИП
Good
Hear can I use 1 neutral wire
Everything apart lighting here is questionable.
1) Why run from 25mm cable suddenly to 16mm?
2) It seems completely useless to wire 2 differential breakers one after another? Could have put a main switch instead of 500mA.
3) Having one dif breaker to everything? You are looking for trouble. If your 30mA dif breaker trips, everything will be without power until you locate and fix the issue.
4) 1.5mm cable for 16 amps circuit? Only if you install cable in the open and even then it will be at the limit.
5) Even worse for 32 amps breaker. At LEAST use 4mm
Wrong...at least 10mm for 32A
Good answer! This scheme is about how you never must do))
Il y a des incohérences dans ce schéma. Utiliser des disjoncteurs unipolaires (avec non sectionnement du neutre) est interdit en France, et sans parler de réglementation je vous déconseillerais fortement car si un défaut se produit sur un circuit le disjoncteur coupera mais celui ci pourrait remonter via le neutre sur d'autres circuits (c'est donc pour ca que l'on conseille de DISJONCTER le circuit eclairage avant de changer une ampoule par exemple). Aussi l'intensité maximale pouvant passer dans un câble de 2,5mm2 est de 24A, je vous conseillerais d'utiliser communément du 6mm2 pour vos circuits 32A.
shit!! write in english!!
You have to describe the names and the load (Amps) of the home appliances. For example fridge, 12 amps, Aircons 13 amps
👌👌👌👌👌👌👌👌👍👍👍👍👍waw
This is helping but the connection to the earth block is not shown
Nice one , but what are the two main circuit breaker on the top, their name and what their use please?
اللہ تعالیٰ مھجے سپورٹ کرنے والوں پر اپنی خاص رحمت کرے اللہ تعالی ہر مسلمان پر اپنی خاص رحمت کرے.Asif Electrical
For just understanding concept of wiring it's okay, but for designing in such way not recommended! For house wiring at least use 2 RCD
I would say something like that, that's the weirdest calculation that I have ever seen. There's no way that you can run a house with the system presented, and considering that usa is mostly 110v forget about it. My house has a 80A breaker and I have to change the wiring ASAP, and here is 220v!
ممتاز نتمنى المزيد
Cuál es la explicación de tener que serial dos diferenciales, es un montaje o condición general o se tiene que realizar en casos particulares.
La idea del cuadro entiendo que es genérica.
Donde se defiende las diferentes etapas en las protecciones.
En la de diferencial de alta sensibilidad es decir de 30ma tendremos una limitación lógica del numero de pias a el conectado por el tema de las fugas de equipos . No se pueden conectar todo ese número de protecciones a un solo diferencial.
A si vez debe poseer cada diferencial una protección magnetotermica general que lo proteja contra sobrecarga, cuando la sumatoria de las intensidades que esta alimentando superan su intensidad nominal.
Y pias de 20 amperios conectando bases de enchufe, estás tienen que poseer una intensidad nominal de esos 20 amperios y suelen ser de 16a.
crazy. Wiring 16sqrm for CB 16Ampe, 20Ampe?
Think about simultaneous work of all el. equipment.
I use te herd that the neutral, blue, always on the left, is oky to flip at the start of the line!!?
todo equipo de linea blanca debería conectarse a la linea con al menos un cable de 4 mm, me parece un poco absurdo que la linea principal tenga un cable de 25 mm lo cual esta muy exagerado para terminar distribuyendo con un cable muy delgado como lo es un 1.5 mm, yo personalmente solo la iluminación la conectaría con un cable 2.5 mm teniendo en cuenta que serán lamparas led, los termomagneticos están correctamente con respecto a sus capacidades y a los equipos que se pretende conectar, pero los cables de distribución solo ocasionaran cuellos de botella.
Спасиба балшой за видйо
Cette installation n'est plus aux normes actuelles. Les disjoncteurs doivent être obligatoirement bipolaires, phase et neutre. la distribution du neutre (fil bleue) est identique à celle de la phase. Pour la terre c'est bon.
1.5 mm wire and 16 amp cb for split type ac
В 3 классе этому учат, я в шоке от заграниц,
C13 elég a konektoroknak 1,5 kábellel. C16-on 2,5 es kábelt alkalmazunk nem 1,5 est mivel azt amúgyis csak 13 amperral lehet lebiztosítani. 20-as biztik feleslegesek a berendezéseknek, bőven elég a 13 is, ha biztosra akar menni az ember 2,5 kábel és c16 doszt elég. c20 amúgyis sok egy 2,5 kábelnek, arra már 4-est alkalmaznak.. Valami agytröszt lehet ez ki ezt összebaszta, de nem villanyszerelő. :D
Please write in english!!
Thanks its a clear video, but i have one question.
Where is the eath connected on the light bulb because the buld have only two pins? 🤔
you can put it inside your box by your own. Or simply use ceiling rose
You are right ,but there is no ground wire
@@azizmizrobov4058 can i just put it inside the box or can i connect intto it
The bulb doesnt have a earthwire.The appliance does..so you wont get a shock if there a fault in the appliance.
Some lighting fixtures have metal/conductive casings & will need to be earthed in case of fault to prevent shock.
یک سوال داشتم در داکت اگر دما در حالت هیتر و سرما ثابت باشد و تغییر نکند چکار کنیم
What's happening when they is lights flickering and the Microwave equipment is running low in power?
Bad connection in the breakerbox or the connections to the breakerbox!
2.5mm+32A
Painfully to watch
what is that green thing on the left?
А лампы накаливания зачем заземлять?)))
Cette installation normalisée merci boucoup&&&&&
Mcb me phes ko connect hamesa niche se kiya jata h
c20 with 2.5mm? c20 needs 4mm cable ! c16 = 2,5 mm
UNE QUESTION? EST IL POSSIBLE DE HACKER SA CONSOMMATION ELECTRICITÉ AVEC UN INVERTER MONTE SUR UN CIRCUIT D'ALIMENTATION SECTEUR DOMESTIQUE POUR UN APPAREIL SPÉCIFIQUEMENT?
According to standards 5A circuit -1.5mm2 10A circuit -2.5mm2 15A-4 mm2 20A circuit -6 mm2
Hungary MCU cable : New standard : Cu 1,5 mm = 10 A ...Cu 2.5 mm = 16 A , and Aluminium (Old haus) 2.5 mm = 14 Amper .
Old standard : Cu 1,5 mm = 16 A ...Cu 2,5 mm = 21 A
Old standard : Aluminium 1,5 mm 13 A ....Al 2.5 = 16 A
Where is that?
@@telosfd he said Hungary, east eroupe or former communist countries. got it??
How much mcb in start?
В счётчик 25 квадратов?)
Не правильно . Надо половину нагрузки пустить мимо счётчика , чтоб по карману не било ...
rccb max 6-7 circuit si separat masina de spalat un rccb mai ales ca lucreaza cu apa iar tratarea nulului nu se vede in schita .
1.5mm conditioner?
So if there is an electricity leak somewhere in the house, the differential circuit breaker will stop the electricity current for everything, lol.
I have a question ✋
Le non du programme de montage
Es incorrecto está sobrecargado la instalación se necesitaría más diferenciales para equilibrar las cargas
32A breaker for 2.5mm ? what's wrong
Yep!To thin wire
I think it must be 4 mm
@@haithemlamri4376 AT LEAST 4mm²..
Also the conductor size for 16A sockets should at least 2.5mm².
Oh there is so much wrong here....
перед счетчиком должен быть авторубильник
😊😊😊😊😊😊💪💪💪💪💪🧠🧠🧠🧠👍👍👍👍