Install air cond wall type

แชร์
ฝัง
  • เผยแพร่เมื่อ 28 ก.ย. 2024

ความคิดเห็น • 43

  • @ItsInova
    @ItsInova 2 ปีที่แล้ว +9

    *So amazingly quiet and **Fastly.Cool** in my room! 42db is at a whisper level. I bought 2 and installed myself.Very sturdy bracket and easy to adjust to fit windows of different size. Absolutely fabulous units!!*

  • @IanGeorge88
    @IanGeorge88 4 ปีที่แล้ว +1

    Most of it was done very well. However a big Zero for the Hero who popped outside with no safety gear or restrain.I have personally witnessed an aftermath of an aircon man 15 storey free fall .Not a pretty sight unless you are a medical professional. Take good care of the safety of every one working on high rise projects like this. Electrical safety using just the plastic extension screw on terminal is a big no no. You guys on the right track improve on the areas I mentioned.Wish you the best.

  • @iskandarsyafrizal351
    @iskandarsyafrizal351 ปีที่แล้ว

    Bagus,
    Suka berkongsi ilmu,
    Sgt cermat dan berskil kerjanya

  • @raundeworld1418
    @raundeworld1418 5 ปีที่แล้ว

    Knapa tak tunjuk masa pasang compressor dkt luar tu...nampak mcm tinggi bgunan tu...nak pasang bracket lg dan perlu ada check utk leaking pd flaring pd sambungan cooper piping tu.

  • @SurinderSingh-mu2oj
    @SurinderSingh-mu2oj 5 ปีที่แล้ว

    Thanks for nice video about split ac indoor unit installation.

  • @bl3727
    @bl3727 4 ปีที่แล้ว

    very good workmanship

  • @rakeshsuthar7441
    @rakeshsuthar7441 5 ปีที่แล้ว

    Good parfact instation

  • @tengkumunshi2544
    @tengkumunshi2544 4 ปีที่แล้ว

    Boleh sy tahu mata untuk tebuk lubang paip tu yg warna kuning kat mana ada jual..?

  • @mdkhalidhassan4457
    @mdkhalidhassan4457 5 ปีที่แล้ว +1

    Behthrin

  • @nothinglastsforever22
    @nothinglastsforever22 4 ปีที่แล้ว

    i think it s a wrong place for inside unit.

  • @itzseafairyplayz5527
    @itzseafairyplayz5527 3 ปีที่แล้ว

    thank you

  • @jimianbu688618
    @jimianbu688618 5 ปีที่แล้ว

    Maaf bertanya, kenapa X ada unit kipas yg box besar tu dekat luar ek? X perlukan ke? 😱

    • @rrsports884
      @rrsports884 5 ปีที่แล้ว

      Unit luar mmg kene ade. Video ni hanye tunjuk cara2 pasang unit indoor je.

  • @fakhrulhaziq3879
    @fakhrulhaziq3879 5 ปีที่แล้ว

    Senang kje pkai 3core...owner umah mintak murah kot..hehehe

    • @mohamadfatihah2843
      @mohamadfatihah2843 5 ปีที่แล้ว +2

      ho meme arh kdg2 owner x tau psl wiring..sy pun dlu terkena sbb x tau walhal x da tawar menawar pun bli ekon siap pasang..bila da blaja tengok channel MAH BAYU ENGINEERING,baru tau teori serba sikit

    • @mohamadfatihah2843
      @mohamadfatihah2843 5 ปีที่แล้ว +1

      Aircond & water heater & socket plug kene pkai 2.5mm

  • @michellariset7824
    @michellariset7824 5 ปีที่แล้ว

    Good job bro😁

  • @s.j7984
    @s.j7984 5 ปีที่แล้ว

    мaι nнι yaнι ĸaaм ĸarтa нυ

  • @muhammadzainiariff482
    @muhammadzainiariff482 7 ปีที่แล้ว

    Mana nk dapatkan hole saw mcm tu??

    • @superpooper_2030
      @superpooper_2030 6 ปีที่แล้ว +2

      muhammad zaini ariff belajar bahasa cina, Ada jual kat taobao online website

    • @akifventuretechakftechnolo257
      @akifventuretechakftechnolo257 5 ปีที่แล้ว +2

      Kat lazada byk je.. Xpyh blajar b. Cina pn xpa..

  • @xiaochu7572
    @xiaochu7572 7 ปีที่แล้ว

    Daikin Cooling King👍

  • @fikrizakaria9817
    @fikrizakaria9817 4 ปีที่แล้ว

    Not recommended !

  • @bongbong5483
    @bongbong5483 5 ปีที่แล้ว +1

    wrong way

  • @julianpuzzo6559
    @julianpuzzo6559 3 ปีที่แล้ว +1

    Es larguísima la lista de cosas que has hecho mal...

    • @farhanmustafa6506
      @farhanmustafa6506 2 ปีที่แล้ว

      Hello sir...im excited to learn more in this industry...may i know what i wrong here n if possible, can u give a link how to do it correctly? thanks !

    • @julianpuzzo6559
      @julianpuzzo6559 2 ปีที่แล้ว +1

      @@farhanmustafa6506
      1-The support plate is incorrectly mounted.
      2-The high and low pressure copper pipes must be in separate insulation, especially in this case where it is a hot/cold unit.
      3-The connection cable with the outdoor unit must never be passed inside the insulation, it must never be in contact with the copper pipes.
      4-When adjusting the nuts with the two wrenches, you use the wrong force, the angle of the wrenches in this maneuver must always close, never open, otherwise the pipes can be irreversibly deformed.
      5-You have left an uninsulated terminal block within easy reach of anyone.
      6-The union of the insulators of the indoor unit with those of the connection pipes to the outdoor unit is wrong, they go exactly the other way around, those that come out of the indoor unit, inside the insulation of the pipes, to avoid leaks of water from condensation.

  • @daddyrafael9728
    @daddyrafael9728 5 ปีที่แล้ว +1

    apa hal cable sumbat sekali jalan dgn cupper dlm insulation tu.. panas lawan sejuk jahanam cable dah pakai 3 core..

  • @cristiancoelho7622
    @cristiancoelho7622 2 ปีที่แล้ว

    Que legal ele por um tubo dentro do tubo p entortar o tubo

  • @nhungtran9538
    @nhungtran9538 5 ปีที่แล้ว +1

    🤑

  • @manjohor1
    @manjohor1 4 ปีที่แล้ว

    Setahu saya paip air bila diubah kekiri nanti air akan ada bertakung pada saluran kanan.Sebabnya sepanjang longkang laluan air tu lebih condong kekanan.

    • @rizalkuruvi
      @rizalkuruvi 4 ปีที่แล้ว +1

      Tak bang... York AC mmg boleh kiri kanan paip airnya, rumah sy 4 unit semua alih ke kiri sbb paip copper semua conseal dlm dinding.
      Alhamdulillah dh 4 thn tak ada apa2 isu.

  • @omaromarez3211
    @omaromarez3211 5 ปีที่แล้ว

    what is the drilled hole size please 50 or 60mm

  • @nhungtran9538
    @nhungtran9538 5 ปีที่แล้ว

    Liên quân mobile👍🏻👌

  • @haikalromeo1962
    @haikalromeo1962 5 ปีที่แล้ว

    Kemas

  • @mdkhalidhassan4457
    @mdkhalidhassan4457 5 ปีที่แล้ว

    Ham bhi aise hi krege

  • @zohaaz33
    @zohaaz33 5 ปีที่แล้ว

    Good job profesional work

  • @vladmir3203
    @vladmir3203 5 ปีที่แล้ว +1

    Profy!!!!