  • @MsladyPearlz
    @MsladyPearlz ปีที่แล้ว +69

    Finally got it up and running. The only delays we had was because we realized we needed some extra parts (I’ll list that below) th-cam.com/users/postUgkxihMYiJNXcHdbH-7ihymsLz61l7jVyb5O . So we have a loft where our current hvac just couldn’t seem to keep cool during the summer. We have been using a window unit since we bought this house over 6 years ago (all the houses in this neighborhood were built in the 80’s and majority of the houses built like ours use a window unit). I hate window units because they are just so noisy and the one we had really only cools one side of the loft. I had contemplated upgrading our current HVAC, but with all the rising prices these days, it would take years before saving up enough to do that. With the advice of my father-in-law (used to run an HVAC business), he recommended we get an inverter instead. We thought we bought everything we needed, but there were just a few other parts we didn’t anticipate needing (which is what caused most of our delay). My friend and father-in-law did all the work to get it installed and running and now we have nice cool air circulating nicely throughout the entire loft. It is very quiet and even the outside unit is much quieter than our main HVAC unit. Saved ourselves thousands getting this.

  • @RedSunFX
    @RedSunFX 2 ปีที่แล้ว +12

    I remember reading in the manual that you should have 3 meters minimum line length. So it's alright to go shorter?

    • @CD-gl7ix
      @CD-gl7ix 2 ปีที่แล้ว +3

      Yes, but you must reduce the refrigerant. a short line is not recommended because it could transfer noises from the outdoor unit to the indoor unit.

    • @maciastrn3024
      @maciastrn3024 2 ปีที่แล้ว +1

      2meters.

    • @josuenolasco382
      @josuenolasco382 ปีที่แล้ว

      Muchas teorías, si se corta la tubería o no.. La estética de la instalación es espectacular con la tubería exacta.

    • @amonraa71
      @amonraa71 6 หลายเดือนก่อน +1

      Min 2 meter

    • @WildersDavid1
      @WildersDavid1 4 หลายเดือนก่อน

      2 m min

  • @ACFactoryChina
    @ACFactoryChina 3 หลายเดือนก่อน +1

    ❤❤❤Greetings from the air conditioner manufacturer from China

  • @joelferreira4020
    @joelferreira4020 ปีที่แล้ว +4

    Great job. Could you please tell me who sells the articulated cable trunking in europe that they put in the exterior unit?

  • @sreejithts9798
    @sreejithts9798 2 ปีที่แล้ว +9

    good technician doing perfect work in proper way

    • @ramonvenegas7644
      @ramonvenegas7644 2 ปีที่แล้ว

      Good technicians don't work on ladders, platform ladders are for that..

    • @5885ronny
      @5885ronny 2 ปีที่แล้ว

      Gut 👍

  • @bluecollardownunder3616
    @bluecollardownunder3616 2 ปีที่แล้ว +6

    Have you ever install multi split before?

  • @kiantracker1499
    @kiantracker1499 2 ปีที่แล้ว +1

    Hi. Best regards, refrigeration and air conditioning technicians. Greetings from Indonesian technicians.

    • @ozanbrooks
      @ozanbrooks 7 หลายเดือนก่อน

      makasih maseh, mongo mongo, hati hati, sampai jumpa,nasi goreng, sate sate

  • @positivevibes-gz4gy
    @positivevibes-gz4gy 2 ปีที่แล้ว +35

    Just so you know you drilled the hole on the wrong side. If you ever need to service the evap head you won't be able to pull the head away from the wall.

    • @mountainklima5602
      @mountainklima5602 2 ปีที่แล้ว +3

      I know what you mean , but the wall is very slim , you can check it from the outside you can see it in 1;21 it comes out

    • @MarcelHVAC
      @MarcelHVAC 2 ปีที่แล้ว

      no

    • @hunyadijanos7678
      @hunyadijanos7678 2 ปีที่แล้ว

      Get 60cm pipping. Nice.

    • @thewiringhub
      @thewiringhub 2 ปีที่แล้ว +2

      It doesn't actually make a difference what side the hole is on 🙂 if you are going to pull it off the wall, you'll have to disconnect the refrigeration pipes anyway 🙂

    • @MarcelHVAC
      @MarcelHVAC 2 ปีที่แล้ว +1

      @@thewiringhub You are right

  • @KingKhan-if6oq
    @KingKhan-if6oq 2 ปีที่แล้ว +1

    Amizing,. But why the excletr of Elictrical down with outdoor, when u serviceing the unit the water can demage it,.

  • @patascaprina
    @patascaprina 2 ปีที่แล้ว +1

    Y que pasó con la bomba de vacío para sacar la humedad de la cañeria y el manometro para estar seguro de la presión adecuada? Y como le harás la mantención después con esos equipos tan pegados a la pared???, Y los desagüe se los llevaron en la camioneta?...

  • @PTBS_Ortega
    @PTBS_Ortega 2 ปีที่แล้ว

    Sieht schob nice aus. Aber warum nicht auf‘s Dach mit den AG‘s?

  • @manishmonu26
    @manishmonu26 2 ปีที่แล้ว +1

    Nice installation 👍 I am from Punjab. 🇮🇳

  • @mikepict9011
    @mikepict9011 2 ปีที่แล้ว +1

    Their like a useful version of a scientist

  • @Adreesuploads
    @Adreesuploads 9 หลายเดือนก่อน +1

    Any videos on how to replace a compressor on these units or simar units like this one ..my air conditioner isn't letting out really cold air so I'm assuming the gas in compressor needs refill or replaced the unit is about 7 years old and only been used mostly in the summer doest the compressor be in the unit inside or the fan on the outside?

  • @escuelacerogrados
    @escuelacerogrados 2 ปีที่แล้ว +4

    Do you recover refrigerant when you cut the line set?

    • @peterantos9449
      @peterantos9449 2 ปีที่แล้ว

      Need job ac am ac mechanic plis

  • @roypjohno8118
    @roypjohno8118 2 ปีที่แล้ว

    Hai Good Morning Super Ac fitings Super job Super idea Super Spead work 👍👍👍👍👍👌👌👌👌👌

  • @manueld.3982
    @manueld.3982 2 ปีที่แล้ว

    Why don't you put the external machines on the roof, where you don't see them.?

  • @OVEDI-PULL_UP
    @OVEDI-PULL_UP 3 หลายเดือนก่อน

    Muy bueno el video, con profesionales mejor. Enhorabuena

  • @dadosdados47
    @dadosdados47 2 ปีที่แล้ว +5

    Without oil trap and 3m steel pipe and without vacuum pump?why?

    • @hanghad7645
      @hanghad7645 2 ปีที่แล้ว +1

      The lines come prefilled with refrigerant

    • @mountainklima5602
      @mountainklima5602 2 ปีที่แล้ว +1

      you dont need oil traps for r410 unless the 2 units are very high apart

    • @dadosdados47
      @dadosdados47 2 ปีที่แล้ว

      @@mountainklima5602 ,if inside unit is under from the outside is nessesary oil trap for the machine to work good for long time.this will have problems after years

    • @mountainklima5602
      @mountainklima5602 2 ปีที่แล้ว +1

      @@dadosdados47 Because R-410A and POE oil mix so well together, oil-trap installation is generally not required on R-410A systems. However, technicians should always be sure to seal refriger- ant lines by crimping them closed and brazing them if they will be exposed to the atmosphere for any length of time.When an HVAC system uses POE (Polyolester) oil, which is typical of current R410a systems, suction oil traps are not required* because POE is miscible in R410a in all phases (liquid, saturated liquid and vapor)

    • @dadosdados47
      @dadosdados47 2 ปีที่แล้ว

      @@mountainklima5602 in your world these maybe exists,not mine friend!

  • @lilheng1694
    @lilheng1694 ปีที่แล้ว

    They're so professional and handsome👍

  • @welitonbruscato
    @welitonbruscato 2 ปีที่แล้ว +6

    Olá amigos, ótimo trabalho parabéns. Só uma dúvida, midea não tem um mínimo de Tubulação para ser executado a instalação.?
    Forte abraço amigos trabalho de vocês é excelente parabéns

    • @micboy22
      @micboy22 2 ปีที่แล้ว +2

      Cara Pensei a mesma coisa duvido que ali tenha 3 metros mínimo

    • @welitonbruscato
      @welitonbruscato 2 ปีที่แล้ว +2

      @@micboy22 tem 50 cm 😂 😂 😂 😂 mas...

    • @rodrigooliveira5034
      @rodrigooliveira5034 2 ปีที่แล้ว +2

      Outro detalhe que achei incoerente é essa tubulação sendo curva 90⁰ após atravessar a parede na prática roda vez que for necessário retirar o aparelho para preventiva terá que desfazer essa curva o que num futuro não tão distante causará a quebra da tubulação,pelo menos eu não gosto de instalar dessa maneira

    • @eng.paulocesar1524
      @eng.paulocesar1524 2 ปีที่แล้ว

      Uma das piores práticas de instalação, pensando em garantia do equipamento e manutenção... instalação sem respeitar a distância mínima, e ainda dobra o tubo da maquina pra fora, numa manutenção precisa desinstalar o equipamento e ainda corre o risco de trinca na tubulação da evaporadora, muito ruim, pensando em acabamento não a o que se discutir, mas qualidade técnica ai... é 0.

    • @СаидМагомедов-г4я
      @СаидМагомедов-г4я 2 ปีที่แล้ว

      @@rodrigooliveira5034 можно за паять

  • @jivazzieraspiazu3762
    @jivazzieraspiazu3762 2 ปีที่แล้ว +12

    Una consulta dónde están los 3 metros de tubería que pide como mínimo el fabricante

    • @welitonbruscato
      @welitonbruscato 2 ปีที่แล้ว +1

      Parece que não tem. Ou possa ser que as normas do fabricante mude 😬😬

    • @kayyumkhan7255
      @kayyumkhan7255 2 ปีที่แล้ว

      Hasankhan

    • @ivaneduardovelazquez6489
      @ivaneduardovelazquez6489 2 ปีที่แล้ว

      Para que o que igual mejor así

    • @JesusRuiz-ro1sh
      @JesusRuiz-ro1sh 2 ปีที่แล้ว

      Por donde avacua el agua del compresor🤭a tuti pley, ni los mas profesionales son profesionales, menuda caca

    • @JesusRuiz-ro1sh
      @JesusRuiz-ro1sh 2 ปีที่แล้ว

      Y dejar la caja de corriente justo por donde tira el agua el compresor

  • @MegaJawaMan
    @MegaJawaMan 2 ปีที่แล้ว

    I like it. This house was very nice. But now it si perfect 😍

  • @tolgacoban5411
    @tolgacoban5411 2 ปีที่แล้ว

    It is recommended to use at least 3 meters of pipe. Why didn't you use it?

  • @JovanMiletic-t7b
    @JovanMiletic-t7b 5 หลายเดือนก่อน

    great work 👍👏

  • @jaideepsethi4278
    @jaideepsethi4278 2 ปีที่แล้ว

    Great work technicians. Come and see how indian ac technicians work ridiculously.

  • @mohsenpanahi6773
    @mohsenpanahi6773 ปีที่แล้ว

    May the God give you the strength.

  • @JasonNYC5454
    @JasonNYC5454 2 ปีที่แล้ว +3

    Neat job. I guess electrician have to supply power to the disconnect switch box.

  • @maxwellpsilva
    @maxwellpsilva 2 ปีที่แล้ว +1

    One observation: the copper tubes between evaporator and condenser less than 3 meters and connection out side.

    • @65416546513213513213
      @65416546513213513213 2 ปีที่แล้ว

      pense en lo mismo

    • @darkfrost999
      @darkfrost999 ปีที่แล้ว

      for some ac it can work at 2 meter minimum, but this is less than that, it's about 1.5 meter i dont know is it ok for the ac or not

  • @Ghostriderz911
    @Ghostriderz911 2 ปีที่แล้ว

    Arent you supposed to have at least 10ft of lineset? Also not a fan of suspended condensers

  • @haniffhaniff5764
    @haniffhaniff5764 2 ปีที่แล้ว

    I need to lift my sinking house but my outdoor unit is placed on the ground. Do I absolutely need to decommission the outdoor unit before lifting the wall? I only need to lift the wall by 7cm or max 10cm. Can I just lift the outdoor unit slowly as I lift the wall?

    • @ДенисГриненко-ф3с
      @ДенисГриненко-ф3с 2 ปีที่แล้ว

      Надеюсь google translate поможет тебе прочесть. Если позволяет длинна медной трубки, то ты можешь аккуратно перенести его выше, лучше делать это с напарником, но лучше вызови профессионалов .

  • @nicklaurencemanangan778
    @nicklaurencemanangan778 ปีที่แล้ว

    Why breaker is installed below the condenser? not beside..

  • @zambalisticofficialtv4615
    @zambalisticofficialtv4615 2 ปีที่แล้ว

    Why do they install the aircon next ton the window and doors.

  • @moeezsiddiqi9864
    @moeezsiddiqi9864 ปีที่แล้ว +2

    Great Work You My Teacher👍

  • @KumarKumar-zh7fe
    @KumarKumar-zh7fe 2 ปีที่แล้ว +1

    Your work good finished

  • @josemariatorroglosatroyano766
    @josemariatorroglosatroyano766 2 ปีที่แล้ว +4

    Buenas noches que lastima de hechar a perder la fachada del edificio poniendo los compresores ahí está muy fácil subirlos al azotea de la vivienda y el sacar los tubos de la línea de frío por el lado de la derecha como que no es lo más correcto.

    • @alexsalazar5028
      @alexsalazar5028 2 ปีที่แล้ว

      Por la izquierda es un poco mas tardado
      Pero es mas facil para desmontar
      La unidad en caso de necesitar mantenimiento

    • @azrael834
      @azrael834 6 หลายเดือนก่อน

      👍

  • @uio86a
    @uio86a 2 ปีที่แล้ว

    Which country? The sky is so pretty

  • @242topboss
    @242topboss 2 ปีที่แล้ว

    Nice work , Love it … where did you purchase work shirts from?

  • @rodrigobritos7342
    @rodrigobritos7342 2 ปีที่แล้ว

    Terrible laburo lo único que faltó o no grabaron fue el vacío al equipo

  • @fanismitsios2450
    @fanismitsios2450 ปีที่แล้ว

    Hello, how long did it take to install both air conditioners

  • @maestrovso
    @maestrovso 2 ปีที่แล้ว

    Single zone systems are the easier to install. Even a child can do it. Try installing a multizone like one that supports up to 8 IDUs. I am a homeowner and just done installing a 5 tons LG multizone, in a 4000 sq ft commercial steel building that is my hobby garage. I don't trust any professionals. I bought my first mini split back in late 90s in US when there was none other brand beside Mitsubishi Mr. Slim. Today, LG is way ahead.

  • @sergiodave6497
    @sergiodave6497 2 ปีที่แล้ว +5

    No respetan los 3 metros de cañería que piden por garantia

    • @darielpozo8209
      @darielpozo8209 2 ปีที่แล้ว +1

      Cómo así??, explica eso.

    • @oliveii_1391
      @oliveii_1391 2 ปีที่แล้ว +1

      Achei que apenas no Brasil que não respeitavam, isso é no mundo todo.

    • @welitonbruscato
      @welitonbruscato 2 ปีที่แล้ว

      @@oliveii_1391 e mundial 😂 😂 😂 😂 😂 aqui o lema é o importante gelar, lá tmb 😂 😂 😂 😂 no investimento que eles tem pelo menos o mínimo deveria ter de Tubulação

    • @EsdrasCirqueira
      @EsdrasCirqueira 2 ปีที่แล้ว +1

      Varia de marca pra marca alguns são 03 metros outro 02 mts outros acima de 04mts importante é gelar o.probelma não a tubulação é sim o excesso de gás que fica na máquina pra distância de tubos a menos

  • @petertoth1808
    @petertoth1808 2 ปีที่แล้ว

    good work.what the flexible air conditioner channel?thx

  • @tamilarasan-gm1lr
    @tamilarasan-gm1lr 2 ปีที่แล้ว +1

    Very good finishing

  • @cosimosantoro2994
    @cosimosantoro2994 2 ปีที่แล้ว

    I manometri abbiamo visto ma nn abbiamo visto cm avete fatto il vuoto all'interno dell'impianto

  • @aljrunasgarali8152
    @aljrunasgarali8152 2 หลายเดือนก่อน

    What is the tool used to make that hole

  • @prasadsharma26
    @prasadsharma26 2 ปีที่แล้ว +3

    Ur work super 🙏

  • @ivan-qb5fd
    @ivan-qb5fd 2 ปีที่แล้ว +1

    Poco más y conectan directamente la tubería que viene del Split la compresor, a eso se le llama ahorrar tubería y además por el lado derecho en vez de por la izquierda para posibles averías y mantenimientos...

  • @jaimebernabesanchezparedes4234
    @jaimebernabesanchezparedes4234 2 ปีที่แล้ว +3

    Saludos cordiales colegas
    Yo Realizó o hago el pasado de las CAÑERÍAS de gas y líquido x el lado izquierdo
    Ojo pará poder dar el buen mantenimiento

  • @higorguimaraes8508
    @higorguimaraes8508 2 ปีที่แล้ว

    La tubulacion no está curta?

  • @carlosschmidt6035
    @carlosschmidt6035 ปีที่แล้ว +1

    An excellent and Beauty installation

  • @2marooni
    @2marooni 7 หลายเดือนก่อน

    There is no minimum 3 meters of copper pipe? Work no good

  • @shiven7841
    @shiven7841 2 ปีที่แล้ว

    Very neet and clean work

  • @pradeepshetty2911
    @pradeepshetty2911 2 ปีที่แล้ว +1

    Sorry brother wrong installation. You should make that hole in left side of indoor unit wall . You only thinking about installation, what about future servicing , if we need to remove ac again we have to break the wall again.

  • @trytodosm
    @trytodosm 2 ปีที่แล้ว

    pro,nice teamwork

  • @altyndom7039
    @altyndom7039 2 ปีที่แล้ว +3

    Great install just needs to upload Timelapse on how the mold grows inside the head units over the years.

  • @johnfalcones9463
    @johnfalcones9463 ปีที่แล้ว

    Hi bro , where it’s the compay ?

  • @magolegend4985
    @magolegend4985 2 ปีที่แล้ว +1

    The copper tube is below 10ft. which is causing a substandard flow of refrigerant...thats not good for the aircon unit.

  • @cephasabani2227
    @cephasabani2227 ปีที่แล้ว

    Wow I just need where someone is installing

  • @ptsmotoadventures
    @ptsmotoadventures 2 ปีที่แล้ว

    Great Job, Nice Powertools

  • @princehlengsizwesayi547
    @princehlengsizwesayi547 ปีที่แล้ว

    Not happy on the isolator under the outdoor unit
    Heating mode water drip what's next

  • @antoniobellantuoni5452
    @antoniobellantuoni5452 2 ปีที่แล้ว

    Bravi colleghi...saluti da italia

  • @vodnok
    @vodnok 2 ปีที่แล้ว

    Nice house with nice color and stone that are totaly ruined by this... Why not putting the ouside unit on the flat roof ?

  • @nazelmenesisjr1620
    @nazelmenesisjr1620 2 ปีที่แล้ว

    Why like that always outside flare nut defficult miantenace for do general service..install very easi maintenance problem

  • @Kauleas
    @Kauleas 2 ปีที่แล้ว +1

    how much does a split install like this cost? what country?

    • @MarkoDoktor
      @MarkoDoktor 2 ปีที่แล้ว

      My question also

  • @rajbiswas1762
    @rajbiswas1762 2 ปีที่แล้ว +3

    Very good work 👍

  • @HelloMTRS
    @HelloMTRS 2 ปีที่แล้ว +2

    Nice work 👍

  • @Hvactoolmakingideas
    @Hvactoolmakingideas 10 หลายเดือนก่อน

    Very nice job....

  • @tamilarasan-gm1lr
    @tamilarasan-gm1lr 2 ปีที่แล้ว +1

    Perfect finishing

  • @rahathasan1035
    @rahathasan1035 2 ปีที่แล้ว

    I need this drill machine and need round wall bit

  • @ijazghani312
    @ijazghani312 2 ปีที่แล้ว +11

    Isolater switch should be away from outdoor unite because if you wash the unite the water will effect the switch.
    Safety first

    • @MarcelHVAC
      @MarcelHVAC 2 ปีที่แล้ว +1

      no

    • @thewiringhub
      @thewiringhub 2 ปีที่แล้ว +1

      That depends if your isolater switch is waterproof or not 😉

    • @richarda.valdes1197
      @richarda.valdes1197 ปีที่แล้ว +1

      It’s in a wheather proof box that’s designed to prevent moisture from affecting the inner works.

    • @richarda.valdes1197
      @richarda.valdes1197 ปีที่แล้ว

      I’d like to know what the customers have to say about this brand ?

  • @jjbsrefairconservices3100
    @jjbsrefairconservices3100 2 ปีที่แล้ว

    Good luck and God bless

  • @peppermeat8059
    @peppermeat8059 ปีที่แล้ว

    is this for like a rent home?

  • @localflorida2201
    @localflorida2201 2 ปีที่แล้ว

    The electric box right under the unit where condense... very smart..🤭🤭.
    Another deficiency. Warranty avoid.

  • @NoorRefrigerationsystem
    @NoorRefrigerationsystem ปีที่แล้ว

    Good job ❤️

  • @5885ronny
    @5885ronny 2 ปีที่แล้ว

    Gutes 👍 Video danke

  • @lugal3193
    @lugal3193 ปีที่แล้ว

    Why not multisplit?

  • @msbaglobalengineering
    @msbaglobalengineering 2 ปีที่แล้ว +1

    Good job

  • @cephasabani2227
    @cephasabani2227 ปีที่แล้ว

    Good work sir

  • @cookingwhitme6444
    @cookingwhitme6444 2 ปีที่แล้ว

    Apologies, behind the outdoor unit need to hawe one circle ⭕️ and then you conekt the instalation.

  • @julioalvarez6683
    @julioalvarez6683 2 ปีที่แล้ว

    I want to see a video of multiple zone installations

  • @aspectr69
    @aspectr69 2 ปีที่แล้ว

    Do you install ventilation systems?

  • @dhirajdeshmukh3853
    @dhirajdeshmukh3853 2 ปีที่แล้ว +1

    Which drill machine used

  • @myHombre
    @myHombre 2 ปีที่แล้ว

    Is that fast or fast forward.?

  • @royalrandomness777
    @royalrandomness777 ปีที่แล้ว

    Midea or Daikin? Which do you prefer?

    • @AexoeroV
      @AexoeroV 9 หลายเดือนก่อน

      Which one you bought?

    • @royalrandomness777
      @royalrandomness777 9 หลายเดือนก่อน

      @@AexoeroV tosot in the end 😂

  • @jon3862
    @jon3862 ปีที่แล้ว

    Looks like professional

  • @sysadmin1947
    @sysadmin1947 2 ปีที่แล้ว

    Excellent Great Work

  • @mariusztom2899
    @mariusztom2899 2 ปีที่แล้ว

    What model of air conditioning is it ?

  • @Surinder_
    @Surinder_ 2 ปีที่แล้ว +1

    What price of one ac installation?

  • @naushadahmed05
    @naushadahmed05 2 ปีที่แล้ว

    how to service outdoor if ur ac power box under outdoor 😇 and conditions minimum 3 metres coper pipe...😂

  • @Qicpal
    @Qicpal ปีที่แล้ว

    Why put machine so high?

  • @marioalbertohernandezrosas2468
    @marioalbertohernandezrosas2468 2 ปีที่แล้ว

    Hubieran puesto las condensadoras en el techo, le quitaron la vista a los acabados de la casa.

  • @JoseMiguelCelisCalderón
    @JoseMiguelCelisCalderón ปีที่แล้ว

    Good friends. You know that if you cut the air conditioning pipe, it automatically loses warranty.

  • @mgrefrigeration2022
    @mgrefrigeration2022 2 ปีที่แล้ว +6

    Very clean and neat

  • @terrysookhoo2528
    @terrysookhoo2528 2 ปีที่แล้ว

    Its been years I haven't see trunking like those

  • @SaimKhan-if4fd
    @SaimKhan-if4fd 2 ปีที่แล้ว

    Nice work

  • @cristianfondati7432
    @cristianfondati7432 2 ปีที่แล้ว

    Porq le sacan el frente y el deflector en tantisimos aires colocados por mi nunca hice eso me parece muy tonto

  • @ip5232
    @ip5232 ปีที่แล้ว

    I know it was the landlord choice but it was so close to be install on the roof and out of sight why not?!!😊

  • @francisjosephorocio5615
    @francisjosephorocio5615 2 ปีที่แล้ว

    How to apply i am interested im aircon techniciann 4years grad in HVAC-RT

  • @joseszilak1717
    @joseszilak1717 2 ปีที่แล้ว

    Todo muy lindo, pero se olvidan que el aceite del compresor va a ir directamente a la unidad interna, haciendo que el rendimiento del equipo no sea el optimo, ademas de no cumplir con las reglas de intalacion de cañeria minima de 3 metros, segun manual....... Todo muy lindo muchachos, pero......