Allen Bradley VFD Powerflex 4M- 3 Wire Control Operation

แชร์
ฝัง
  • เผยแพร่เมื่อ 13 ธ.ค. 2024

ความคิดเห็น • 25

  • @RS_83
    @RS_83 10 ปีที่แล้ว +2

    Thank you, Mr.Singh! I like your videos,one of the best educational videos on industrial automation. Delta PLC videos are great! Greetings from Russia! Спасибо!

    • @thegeterrdone
      @thegeterrdone  10 ปีที่แล้ว

      Hi Smith, Thanks for the appreciation :) I'm glad that it serves you!
      Greetings from NFI, India

  • @robertonogueira9874
    @robertonogueira9874 6 ปีที่แล้ว

    Mr Singn. You are the best. Congratulations, from Brazil.

  • @andrewregalado7812
    @andrewregalado7812 9 ปีที่แล้ว +1

    thank you so much this made a lot more sense then when I learned about it at school. It's greatly appreciated for your help. Many thanks.

    • @thegeterrdone
      @thegeterrdone  9 ปีที่แล้ว

      Hello Andrew Regalado - Your welcome! ;) get some free/paid courses at online.nfiautomation.org

  • @danielbaldespinosa7045
    @danielbaldespinosa7045 10 ปีที่แล้ว +1

    Thank you Mr. Singh. If ill just use an ordinary NO push button switch for NO(R2) how will it run continuously?

    • @thegeterrdone
      @thegeterrdone  10 ปีที่แล้ว

      By using 3 Wire control, you can make it run continuously.

  • @ernestogonzalez194
    @ernestogonzalez194 8 ปีที่แล้ว

    Hello Rajvir, thank you for your video, can I wire the drive using a micro switch on the motor just to make it turn one cycle and make it stop once completed, and of course im using a plc to control the drive start cycle, hope to hear from you, thanks in advanced!

    • @thegeterrdone
      @thegeterrdone  8 ปีที่แล้ว +1

      Hello Ernesto, i did not understand your question, can you please write to me at nfiautomation@gmail.com to brief your query.

    • @ernestogonzalez194
      @ernestogonzalez194 8 ปีที่แล้ว

      Rajvir Singh, thank you so much for your response, I already figured the wiring and input the correct parameters on the drive, now it works li a charm, thank you very much, greetings!

    • @thegeterrdone
      @thegeterrdone  8 ปีที่แล้ว +1

      Alright, that's great! Happy to hear that. Cheers !
      Greetings from Germany!

    • @ernestogonzalez194
      @ernestogonzalez194 8 ปีที่แล้ว

      Rajvir Singh greetings from the U.S.A!! I'll reply to your mail and show you what we did, Thank you!!

    • @thegeterrdone
      @thegeterrdone  8 ปีที่แล้ว

      Alright great ;))

  • @alubaydy
    @alubaydy 5 ปีที่แล้ว

    The diagram is wrong, is sourcing mode you connect 11 to 1 directly in your diagram you show that you connect 11 to switches.

  • @martinbrowne4922
    @martinbrowne4922 6 ปีที่แล้ว

    Mr Singh thank you for posting this video would the same method apply for the powerflex 40

  • @dhimand3
    @dhimand3 9 ปีที่แล้ว +1

    thnx a lot sir how can i learn more about plc and drives

    • @thegeterrdone
      @thegeterrdone  9 ปีที่แล้ว

      Dushyant Dhiman To learn more about PLC and Drives please check this course: online.nfiautomation.org/catalog/1769?couponCode=LEARNING_MADE_EASY

    • @thegeterrdone
      @thegeterrdone  9 ปีที่แล้ว

      Dushyant Dhiman To learn more about PLC and Drives please check this course: online.nfiautomation.org/catalog/1769?couponCode=LEARNING_MADE_EASY

    • @IndependantMind168
      @IndependantMind168 9 ปีที่แล้ว

      +Rajvir Singh (NFI Automation)
      Hey Raj. Great vids!!.
      Is it some how possible to use the 0-10v in to control the enable AND the speed reference? Maybe utilizing the relay and digital IO's in combination. I have a powerflex 40 110ac single phase to 220v three phase and am trying to get away with using a extra pins from my digital controller just to enable. Right now I just push keypad to start and use remote voltage ref to control speed. It would be great if I could trick the drive into saying "if voltage from source is below xV then disable OR if voltage is above xV enable. I think it is possible,but I just can't see it as I'm so new to these drives.
      Thanks for any input. Again, Great videos.

    • @thegeterrdone
      @thegeterrdone  9 ปีที่แล้ว

      +J Santarsiero I guess it's possible. You can use the feedback terminal of your drive to enable the contact when the input freq/voltage is above say 5Hz/1 Volt. Use that contact to enable (RUN) the VFD. But im not sure. This feature depends on drive to drive. Please check the manual for the same.

    • @IndependantMind168
      @IndependantMind168 9 ปีที่แล้ว

      +Rajvir Singh (NFI Automation) I'll look into this. Thank you.

  • @mohankarmakar7874
    @mohankarmakar7874 5 ปีที่แล้ว

    Hou to fault clear video please
    Power flex m4 vfd

  • @sanjeewsan5146
    @sanjeewsan5146 6 ปีที่แล้ว

    Sir Mitsubishi ke sath vfd and plc ka communication batayena sir in Hindi me

  • @oryxengineering4383
    @oryxengineering4383 6 ปีที่แล้ว

    good morning sir this is Himanshu from burq energy Ghaziabad. please upload vedio digital input parameters settings