Hello Thanks for the wonderful video. I'm using Danfoss VLT HVAC Basic Drive FC 101 and want to use pushbutton for speed up and down. But I noticed there is no terminal 33. As per the manuals, only model Danfoss VLT micro drive FC 51 and VLT automaton drive have terminal 33. Please advise how to use pushbutton for speed up and down for Danfoss VLT HVAC Basic Drive FC 101. Thank You
Professor bom dia! eu fiz essas ligaçoes que o senhor ensinou, coloquei os parametros 5-13=21 e 5-15=22 e mesmo assim o inversor não funcionou a aceleração e desaceleração. tem mais alguma habilitação ?
Hello i have Danfoss FC51 i done all the same programing like on your video, just my Danfoss something wrong,when push button start he starting,but he is not stoping or speed up or speed down. Maybe you know what the problem can be?
Está funcionando partida liga e para, botão de emergencia so falta acelerar e desacelerar, quando vou no parametro 16-60 percebo que as entradas estão chegando. um abraço aqui do Brasil.
Using Parameter 19 as stop does not make any sense. Why use freeze reference to stop the drive when you have an specific parameter to truly stop the drive? This is just misleading people.
Bahut. Sunder. Samjhate. Hai. Bahut. Dhanybad
Thanks
Thanks.for the wonderful video
Thanks for watching
Nice explain.
It's working exlent.
At the same time we have to also auto run through 4-20ma sources.
Please share some videos
Thank you sir.
Nice information bro good 👍
Thanks
Well done sir....
Thanks
Sir.phon.nobbor.din
Sir
Hello
Thanks for the wonderful video. I'm using Danfoss VLT HVAC Basic Drive FC 101 and want to use pushbutton for speed up and down. But I noticed there is no terminal 33. As per the manuals, only model Danfoss VLT micro drive FC 51 and VLT automaton drive have terminal 33. Please advise how to use pushbutton for speed up and down for Danfoss VLT HVAC Basic Drive FC 101.
Thank You
Super kam kar raha hai
Thanks
Good job 👍
Thanks 👍
Dhanybad. Sir. Pura. Paramiter. Pe. Video. Banaye. Sir
Thanks
sir Ji nietz vfd programs kabhi jankari de dijeyega
Sir Mitsubishi A 800 ke bare me program samjao
Sir is me ham speed prot laga sakte he
Start stop jog ke stah me speed port pe control kar sakte he
sir you have not made any lecture on dc drive still. plz make over abb or siemens make dc drive video
Sir invt ko syncharonzatin kasay kartay hain vareabal par aur pushbatton par kasy syncharonzatin kartay hain
Professor bom dia! eu fiz essas ligaçoes que o senhor ensinou, coloquei os parametros 5-13=21 e 5-15=22 e mesmo assim o inversor não funcionou a aceleração e desaceleração. tem mais alguma habilitação ?
Hello i have Danfoss FC51 i done all the same programing like on your video, just my Danfoss something wrong,when push button start he starting,but he is not stoping or speed up or speed down. Maybe you know what the problem can be?
Check wiring
@@Electrical-Automationif wnated to use reverse
Dada vackency hai kya mujha ap se bohot kuch sikna ha.
Está funcionando partida liga e para, botão de emergencia so falta acelerar e desacelerar, quando vou no parametro 16-60 percebo que as entradas estão chegando. um abraço aqui do Brasil.
Dhanybad
Thanks
Great
Sir , dono direction me chalega kya ??????
Is programing me ek hi direction me chalega
Sir pid se speed control ka video banaye
Very nice Sher nowlag
Siemens vfd par bhi kai vidio banai ye sar
How to 3.wire lockel remote control wiring pls explained sir. Or diagram send sir
Thank's
Sir mene sir aisa hi kiya par stop button press karte hi 50hz se speed drop hokar 20hz tak aata hai per motor stop nhi hota hai
Sir Is ke Sath Selec Pic 101 RPM Meter Kaise Connection Karna Hai Or us Ka Vfd Main para Meter KiyaHai? Thank You
th-cam.com/video/7GDyo7PRYQs/w-d-xo.html ek bar is video ko dekh kr try kro
Nice
Thanks
On krte hi ata he A L 47
Kya kre
Control card ke problem hai
Good
Sir same video delta vfd c2000 par banoo sir pls.
Dear drive nhi h ...
Parameter bata sakta hu
@@Electrical-Automation bato sir par complet parameter batna sir kuch youtuber to galt batae hai pls
Okay
@@Electrical-Automation Ji sir batoo sir ek machine khrab kadi hai ji drive change kar di hai Ji apna WhatsApp no do sir ji pls.
Dear hum log site me bhi VFD Installation karte hai
+91-7440518357
Sir FC301 KA PARAMETER AUR WIRING WITH DI AND AI START STOP KA REFERENCE 2 SWITCHING KA PARAMETER
Abhi drive nhi hai
sir relay ka trip ka paramitar bataye
Sir two pump logic or three logic ki vedio dalo na
Sir explain panala border connection and E ta control
Sir ji reverse and forward and speed up and down with four green push button is possible if yes pls tell me program and wiring
Microdrive ig 5 SV 022ig 5 A- 4 11981940511
micro drive Sv 022Ig 5A
Sir 1second push button press karke 1hz increase decrease ka parameter konsa he
Sir please make a video ...
Ek drive k analog refrence se dusri drive ko run krna h
Vfd synchronization ka video bana hua h...
th-cam.com/video/URFV093JXfc/w-d-xo.html
Sir sem wiring aur sem perametar dale par drive stop pushbutton se stop nahi hoti he to kya kre
Denfoss fc 380
How to add emergency stop to fc360 danfoss drive ?
Upparwala display kaise nikalna sir
🎉❤❤❤
Thanks
Hello sir danfoss drive me U7 foult bata kar shutdown ho jata hai kya reason hai
Drive ka model kyun sa hai
Sir yah Sab kar ka v speed up down n hote .1.0 ma konsa parameter dale
1.0 me koi zero hi
Ok
💕Dear Boss
Please please please
Tell me that how to control frequency LS & yeskawa inverter with push button switch
Thanks
Video in playlist
@@Electrical-Automation
💕Boss
If you don't mind can you send me link please🙏
Sorry no video using push button for frequency
@@Electrical-Automation
Boss 💕
Please make a video, frequency up down system in push button switch in LS invarter.
Thanks 😊
Sir pls I need c 2000 ,speed up and down programme
Select 2 digital input for digit UP digit down (19,20) for up down
Ismein fault kaise aate Hain sar
Sir danfoss vfd w8 bata ke band ho jata he q?
Voltage drop ho raha hai. Ek bar input voltage check kro, phir voltage warning ka low limit ka parameters check kro
How to bypass encoder sir
PNP & NPN kab set karate hai
As per need
Why freeze reference in 5-12 - 19
Sar Mera drive Garam Ho Raha Hai Sar uske liye koi HAL to bataiye Sar please
Panel me cooling fan nhi h kya
Why 19 no is not used for stop pb
Micro drive parameter sv ig-A
Hello sir
Terminal program then
Not working in my drive
Apka avaj bahuth kam nahi sunarah
Bhai apna number Doge kya bhaiya Humko bhaiya sikhana hai bhai aapse bhai drive setting Humko nahin aata hai bhai Bata dijiye bhai humko pura video acchi pura Banakar bhai
Keypad se on of hai
Yes sir U7 bata kar off ho jata hai
Incoming voltage check karo or DC bus voltage
Ab Mera timer Jyada Garam ho raha hai
Sir drive me alarm 14 aaraha hai
Kaise clear hoga please tell me
Drive ka igbt short ho gaya hai
Isliye ground fault aa raha hai
@Genus Controls
Sir possible solution kya ho skta hai usska
@@tabrezakram5729 repair
VLT micro drive fc 51
DC bus voltage kitna aa raha hai drive me
Sir no dijiy
chat.whatsapp.com/Ku7hxLBBeWd5EjW1q66ybV
Bangla te din
400 volt
Or DC BUS voltage
Using Parameter 19 as stop does not make any sense. Why use freeze reference to stop the drive when you have an specific parameter to truly stop the drive? This is just misleading people.