🔴 danfoss drive start stop using push button || vfd programming in hindi
ฝัง
- เผยแพร่เมื่อ 20 ธ.ค. 2024
- IN THIS VIDEO EXPLAIN HOW TO danfoss VLT Micro drive start stop using push button in auto mode
danfoss drive parameter setting
danfoss drives programming
danfoss drives manual
danfoss vfd control wiring diagram
danfoss vfd parameter setting
danfoss drive 3 wire wiring
danfoss vfd wiring
start stop push button
auto manual
danfoss drive auto remote coast
डनफोस ड्राइव की वायरिंग कैसे करते है
प्रोग्रामिंग कैसे करते है
पैरामीटर कैसे सेट करते है
#Delta #schneider #danfoss #yaskawa #EMERSON #abb #AllenBradley #wecon #L&T #fuji #invt
Playlists:
#schneider #altivar #vfd #programming
• 🔴 schneider altivar v...
#Delta #VFD #start #stop and #frequency #increase and #decrease using #Remote #push #button
• 🔴 Delta VFD start stop...
#danfoss #vfd #drive #frequency #up and #down using #Remote #push #button
• 🔴 danfoss vfd drive fr...
VFD (drive) start stop using PLC
• 🔴 VFD (drive) start st...
yaskawa drive parameter setting
• 🔴 yaskawa V1000 drive ...
vfd #AC drive #synchronization
• 🔴 vfd | AC drive | syn...
#siemens #micromaster 440 #Drive #parameter #setting | #motor #parameter | Remote | Potentiometer
• 🔴siemens micromaster 4...
#abb drive parameter setting | #2/3-Wire Mode |
• 🔴 abb drive parameter ...
EMERSON DRIVE PARAMETER SET, DOWNLOAD & SAVE
• EMERSON DRIVE PARAMETE...
Emerson Control Techniques Commander SK AC Drive PARAMETER UPLOAD USING CTSoft
• Emerson Control Techni...
#emerson #control #techniques #commander #sk #drive parameters
• 🔴 emerson control tech...
COMMUNICATION BETWEEN KINCO AND DELTA
• COMMUNICATION BETWEEN ...
#allenbradley #panelview #plus #hmi program upload
• allen Bradley panelvie...
SIEMENS S7-200 PROGRAM #UPLOAD #DOWNLOAD
• SIEMENS S7-200 PROGRAM...
PLC #Implementation Of Forward Reverse Motor Circuit With #Interlocking
• 🔴 PLC Implementation O...
reverse forward POWER and CONTROL connection With #simulation
• reverse forward connec...
Allen Bradley PLC Implementation Of #Forward #Reverse Motor Circuit With Interlocking • 🔴 PLC Implementation O...
rslogix 500 installation- create Virtual floppy drive
• Video
#mitsubishi fx PLC programming software free download and install
• Video
#siemens #s7 1200 #plc program upload WITH TIA PORTAL V13
• 🔴siemens s7 1200 plc p...
danfoss drive start stop using push button || vfd programming
• 🔴 danfoss drive start ...
#dol #starter #control #circuit | local remote #multiple #point control wiring diagram
• 🔴 dol starter control ...
allen bradley vfd start stop using push button #3Wire operation (हिंदी)
• 🔴 allen bradley vfd st...
#jog operation in vfd | inching operation in allen bradley vfd | parameter setting
• jog operation in vfd |...
how to #allenbradley VFD START STOP using PNP NPN SENSOR
• 🔴how to allen bradley ...
#delta plc #pnp #npn #sensor plc input wiring
• pnp npn sensor plc inp...
VFD forward and reverse wiring with programming #logic #Relay #drive
• 🔴VFD forward and rever...
HOW TO UPLOAD SIEMENS HMI PROGRAM
• 🔴 HOW TO UPLOAD SIEMEN...
#schneider vfd #programming
• 🔴 schneider altivar v...
#crompton #greaves #emotron #vsb ac drive wiring
• 🔴crompton greaves emot...
Thanks bro for uploading that important video on VFD . Really it's very helpful for the ppl n also for me. N really u explained in very easy language and solid example .
Thanks
सर.जी समझाने का तरीका बहुत अच्छा लगा।
Thanks would you please make video veichi drive thanks
excellent information thank you sir
Thanks
thank you kafi achhe se samjhaya aap ne lekin ye nhi bataya ki motor ki sari details kis kis mai bharni hai
Normally motor ke parameter by default set hote hai..
Sir aap 50 and 53 terminal ke bare me nhi bataya. Can u explane it plz..
Video h playlist me... 50 53 me potentiometer connection krte h
Very Very thanks sir
Ek vedio digital v, I, p meter
Through ct transformer connection and programming
Pr ek vedio banye.
Dear jb bhi mere pass meter aayega
@@Electrical-Automation mai sir samjh nhi paye aap kh Kya rhe hai.
Dear abhi mere pass meter nhi hai to video nhi bana sakta
@@Electrical-Automation in future me
Kabhi bhi ek vedio banye aap
Because apke samjhane ke techniques best hai.
Thanx
Very nice explain
Display not working how to check Other wise weldone suggestions thanks
Excellent define ...
Good job
Hello sir.. Iss drive me no/nc contact ke liye konsa port hota he?? Please reply
Terminal 1,2&3
Is there an English version anywhere?? I'm really struggling wiring up buttons to my Danfoss unit.
Excellent...Thanks for your help
Thanx for comment
Sir JI apne Jo vayrig ki uska para step by stap video banao
Well done and Thank you so much. I am now in London and have a Machine needs setup so could you please tell me any technician that I can contact for this matter.
Dear sir you explained very well .Can u explain its foults and troubleshootings becouse my drives r facing 14 and 16 number foults and r not removing..
Drive me short circuit ho gaya h ..may be igbt khrb ho gaya hai.
Aap ise repair karwa sakte hai...
@@Electrical-Automation DEAR SIR WE HAVE THREE DRIVES LIKE SAME CAN U SUGGEST US WHERE TO REPAIR?
Genus controls also repair drive
Sir ,How to frequency limit set in this drive
Sir plz make on video two drive tension control mode
Repair ke bare me kuch bataue
Bhai preset frequency kahan se set karte h
A mitar or pra mitar kya hoga sir
sir muje motor ka frequency ki badaani hai konsa parameter hai
Sir can i change danfoss vfd 301 15kw with danfoss vfd 51 micro drive
Kar sakte hai.
hi.. need help on VFD
Kya
Sir manlo 10hp ki motor aur 10hp ki denforce ki drive connect krni ho toh programming shuru se btaye pls
Is video me Jo bhi parameter bataya gaya h aap use set Kro ... motor 10 HP ho ya 1HP motor ke parameter by default Dale rahte h hame bus control parameter dalna hota hai..aap ek bar try Kro koi problem aaye to comment Kro..
Thanks for comment
Push button hold kaise rahega start ya stop
Sir danfoss FC 51 me overload protection parameters bataye motor trip nahi ho rhi hai
1-24 motor over current
5-40 me jakar above current high set kar do
This would be so great if I could understand it! Cant get the fc 51 to start with control wiring. Ill have to try and contact customer support. I think you are giving all the parameters but I cant understand it. Thanks for the video
Sir please explain transmistter output (4-24MA) based drive auto operation .
4-20 mA transmitter output use as a drive analog input for speed
@@Electrical-Automation I'm asking wiring and parameters data
Please give the detail circuit diagram....
3 wire me without potentiomete kaise chalayenge
Sir as you told that by default maximum frequency set at 50 Hz when you started drive then why display showing 61 Hz? Thanks
Thank you this information
Sir how to clear alarm 47 in danfoss FC 101
Please check drive +24V control voltage
RS 485 communication fail ho rha hai w8 alarm coming can help please
W8 to under voltage ka fault hai
sir frecon fr 100 fr200 speed up down by push button wiring and programs plz send
Run Command which are?
Hi, how to connect a digital remote ampere meter
Acceleration time deceleration time ke bare men jankari chahiye sir sam modal
Acceleration 3-41 (ramp Up time )
Deceleration 3-42 (ramp down time)
Thanks for comment
Thanks accel time and decel time batane ke liye
@@Electrical-Automation thank you sir video banane ke liye
Fc 301/302 ko START STOP terminal se aur increase decrease push button se run karane ka parameter batao
Thank you bro 😀
Well done sir but we want to only use single NO select switch for the on off drive .... Is it possible ...so Kindly give me reply
Kar sakte h
Selector switch ka use krke
Sir, parameter digiya na.on and off
Display not working how to repaire
Hello
Ya 50 or 53 py 2 red wire kidr sy aa rhi h
Potentiometer ke wire h
@@Electrical-Automation kiya ap potention ki pic baj sakti h
Sir PNP MODE AUR NPN MODE ME KYA ANTAR HAI AUR KIS TIME PNP MODE RAHEGA AUR KIS TIME NPN MODE PAR
Jab hum controlling 24+ se karte hai to PNP Mode hota hai
Or jab controlling 0Vdc ya GND se karte hai to ye NPN mode hota hai
Community me iska configuration post Kar Diya hai.
Parameter 5-12 for reset. Setting to '3' like you show doesnt work. It then wont let the start button start. Any help please??
5:10 = 9
5:12= 3
For start stop push button program
@@Electrical-Automation i have set 5-10 = 9 and 5-12 = 3 but it wont start. Only if i change 5-12 = 1 but then it will start but not stop.
Please check start stop push button wiring
Sir, how to clear alarm no.59
Motor ka current multimeter se check karo agar parameter 1-24 me set current se jada hoga to ye fault aayega
Relay?
AL16 issue shows alarm how to solve it sir
Short circuit
Motor ya drive me problem h
Auto on nahi hota hai hand on karna padta hai kya problem ho sakta hai
Parameter or wiring check karo
@@Electrical-Automation 0.0Hz nahi dikha raha par uski jaga 0.0 Nm dikharaha hai uska to koi folt nahi hoga
No do to me what's app pe photo bheju
@@hitendrasinhrajput4728 genuscontrols@gmail.com
Send mail
Sir siemens g120 ka parameter aur connection bataiye
Sir potention switch connection proper wiring
Potential switch ke 1-3 me drive se 10Vdc supply dete hai or potential switch ka 2 number terminal drive ke analog input me connect krte h
Plz sir complet wiring with power wiring
Power wiring ke terminal bataya h..kaha power wiring krna h..or kaha motor ke wire
What's 2/3 control?
2-Wire=Controlling using two wire connection in drive
3-Wire=controlling using 3 wire connection in drive like start stop button
@@Electrical-Automation 2 wire control that means 24vdc put din by selector switch?
You forgot to tell 50 and 53 shorted otherwise it won't start
How to set password in danfoss VLT a.c. microw drive
Kya kya program krna h list me update kro
th-cam.com/play/PLOHa5Bpj1gCO2IaDgsu6pabK9aw7FGWt5.html
Bhai agar mera drive run ho gya to I'll subscribe your channel or else I won't.
Sorry sir it is not complete wiring
Kya problem h thoda bataoge
auto me indication aata hai lekin run nahi hota
Sir, how to clear alarm no.13
Over load ka msg hai...
motor current nameplate or parameter 1-24 same hona chahiye..
Ya ho sakta hai motor me load jada aa raha ho...