🔴 danfoss drives troubleshooting | FAULT Alarm relay | programming | hindi
ฝัง
- เผยแพร่เมื่อ 5 ต.ค. 2024
- danfoss vfd parameter setting for relay
AL 13 over current alarm
over voltage alarm
AL 04 Mains phase loss
igbt fault
dc bus voltage
DRIVE READY INDICATION
AUTO MANUAL INDICATION
danfoss vlt micro drive #alarm codes
AL 07 AL 08 AL 13 AL 14
#Delta #schneider #danfoss #yaskawa #EMERSON #abb #AllenBradley #wecon #L&T #fuji #invt
Playlists:
#schneider #altivar #vfd #programming
• 🔴 schneider altivar v...
#Delta #VFD #start #stop and #frequency #increase and #decrease using #Remote #push #button
• 🔴 Delta VFD start stop...
#danfoss #vfd #drive #frequency #up and #down using #Remote #push #button
• 🔴 danfoss vfd drive fr...
VFD (drive) start stop using PLC
• 🔴 VFD (drive) start st...
yaskawa drive parameter setting
• 🔴 yaskawa V1000 drive ...
vfd #AC drive #synchronization
• 🔴 vfd | AC drive | syn...
#siemens #micromaster 440 #Drive #parameter #setting | #motor #parameter | Remote | Potentiometer
• 🔴siemens micromaster 4...
#abb drive parameter setting | #2/3-Wire Mode |
• 🔴 abb drive parameter ...
EMERSON DRIVE PARAMETER SET, DOWNLOAD & SAVE
• EMERSON DRIVE PARAMETE...
Emerson Control Techniques Commander SK AC Drive PARAMETER UPLOAD USING CTSoft
• Emerson Control Techni...
#emerson #control #techniques #commander #sk #drive parameters
• 🔴 emerson control tech...
COMMUNICATION BETWEEN KINCO AND DELTA
• COMMUNICATION BETWEEN ...
#allenbradley #panelview #plus #hmi program upload
• allen Bradley panelvie...
SIEMENS S7-200 PROGRAM #UPLOAD #DOWNLOAD
• SIEMENS S7-200 PROGRAM...
PLC #Implementation Of Forward Reverse Motor Circuit With #Interlocking
• 🔴 PLC Implementation O...
reverse forward POWER and CONTROL connection With #simulation
• reverse forward connec...
Allen Bradley PLC Implementation Of #Forward #Reverse Motor Circuit With Interlocking • 🔴 PLC Implementation O...
rslogix 500 installation- create Virtual floppy drive
• Video
#mitsubishi fx PLC programming software free download and install
• Video
#siemens #s7 1200 #plc program upload WITH TIA PORTAL V13
• 🔴siemens s7 1200 plc p...
danfoss drive start stop using push button || vfd programming
• 🔴 danfoss drive start ...
#dol #starter #control #circuit | local remote #multiple #point control wiring diagram
• 🔴 dol starter control ...
allen bradley vfd start stop using push button #3Wire operation (हिंदी)
• 🔴 allen bradley vfd st...
#jog operation in vfd | inching operation in allen bradley vfd | parameter setting
• jog operation in vfd |...
how to #allenbradley VFD START STOP using PNP NPN SENSOR
• 🔴how to allen bradley ...
#delta plc #pnp #npn #sensor plc input wiring
• pnp npn sensor plc inp...
VFD forward and reverse wiring with programming #logic #Relay #drive
• 🔴VFD forward and rever...
HOW TO UPLOAD SIEMENS HMI PROGRAM
• 🔴 HOW TO UPLOAD SIEMEN...
#schneider vfd #programming
• 🔴 schneider altivar v...
#crompton #greaves #emotron #vsb ac drive wiring
• 🔴crompton greaves emot...
Schneider
allen Bradley
danfoss
ac drive potentiometer & AVI(0-10Vdc) & ACI(4-20mA)
sink & source wiring
sir jog ka kya matlab hota hai plese explain jog mein parameter daal kr motar start video banaye
Next video Jog command par
Jog command th-cam.com/video/XuojKK6b93Q/w-d-xo.html
You are doing good job sir
Sir bahut acchi video banayi hai aapne..please ye bataye ki VFD ke alarm ki condition me jo indicator on hota hai uska connection kis point per hoga..plz thoda detail me bataye sir
Common or NO POINT se
Very informative and interesting
Good job really helped me
I need parameters list for parameter # 5 - 40
Good sir thank you
Most welcome
v nice explain
Nice
Thanks
How to control drive with pressure transmitar on &off please make a video sir
Hi,Agr danfos vfd vlt derive mein alarm 14 earth fault aaye to usko kis trah se repair kr skte hen
Hi. Can i use 3 phase vfd in single phase motor. The vfd voltage 200 to 240 v
Pressure ternsmiter ke through drive ki speed kaise control Kare please bataye
AL 29 Rision our keshe slove hoga dangoss vfd
Sir ji Danfoss FC301 KI WIRING aur auto tuning with complete parameter ka video banate ye choti drive ka to ek baar ho jaata hai aap video sahi banate hai
Auto tuning ka parameter hai 1.29
Isme do option hai
1. static :agar hamari motor load se connect hai to parameter 1.29 me 2 kar dete hai .
2. rotatry :agar motor load se connect nhi hai to parameter 1.29 me 3 kar dete hai.
sir power fail hone ke baad manual reset krni padti ha,koi setting bta do jo auto reset ho jay
Super
Alrm 13 and Alrm14 par videos bnae
Hello Sir
I have danfoss fc102 which is running smoothly. But i am getting an alarm repeatedly as( 2 warnings see alarm log) i checked and found its earth fault and short circuit. I checked the circuit and motor found everything in condition. Please help me to find the solution for this.
Check igbt
CAN YOU WRITE ON ENGLISH HOW TO FIX ALARM 8 ON DANFOSS? BECAUSE HINDI LANGUAGE IS NOT UNDERSTANBLE..!
Ye video allen bradley ke sath banay sir
What is the reason of alarm13
Sir i m using abb ACS 310 and i m getting alarm F0009 OVER TEMPERATURE How to resolve this alarm
Please check motor load
भाई एक question tha
Ager vfd ke output me MCB ya relay lagaye to kya wo work karegi
Mcb work karega..
Kis relay ki baat kr rahe ho?
@@Electrical-Automation over load relay
Use
Drive khud hi amp control krta hai
Al 46 alarm??
Sir autotuning kaise hoti hai iske bare mein bataye
Auto tuning ka parameter hai 1.29
Isme do option hai
1.agar hamari motor load se connect hai to parameter 1.29 me 2 kar dete hai .
2.agar motor load se connect nhi hai to parameter 1.29 me 3 kar dete hai.
Hi.... Mera pas ek danfoss ka 3 phase 240 v ka vfd hei ye vfd mereko 1 phase use kar sakthe
Input 230 hona chhiye
Hi sir iam using Danfoss VLT FC102 iam getting error DC Over Voltage AL7 could you pls help me application is compressor motor 250kw I have increased Ramp up/down time from 8sec/15sec still the error same pls help me
Decrease ramp time and install DBR
@@Electrical-Automation Sir what should I decrease Ramp Up time or Ramp Down time and the DBT I can't install due to no option available in Hardware to install but in the LCP I can see the brake Resistor parameter
AL14kis ka alarms he kese clear hoga
Ground fault..drive ka igbt check karo..
@@Electrical-Automation ok sir thank you
sir please bataye danfoss drive mai igbt kya hota hai
@@alwayssmile6928 igbt to sabhi drive me hota h
Sar danfuss drive 1hp,0.75kw vfd my 42 triminel work keya haa please datadigea
Analog output h
Excess start time kay hai alarm
AL8 kis chija ka alarm h
Error 84 fault clear kaise hoga please reply
Sir danfoss micro drive fc51 ka alarm 8 kaise clear hoga...
Permanent alarm aa raha hai....
Please tell me ASAP
Dc bus voltage check kro kitna aa raha h
Waran 12 aa ke alarm AL 9 aa raha hai
Machine ko on off log distance se karna he operating panel or Maine panel se on - off ke liye Kya Kare or Jase akre pl
Auto manual option
@@Electrical-Automation Auto me
Auto mode ke liye video play list me bana h
Sir Please suggestion for alram 12
4-16 increase
@@Electrical-Automation thanks 🙏
Al 046
Sir danfoss micro drive fc51 ka alarm 8 kaise clear hoga.permanent alarm aa raha hai...
Dc bus voltage kitna aa raha hai..or drive me kitna set h o check kro
Kaun se parameter mein check kre sir
Please reply
please make videos in English language ,
Al 29 Rision
Sar danfuss drive t/c: FC-051PK75T4E20H3XXCXXXSXXX ,P/N: 132F0018, 0.75KW 1.0HP DRIVE MY ALARM AARIYAHA TO ESKI KASHAY RESET KARAGHA? HAM TRAY KIYAHA BUT KUCH NIYHI HORAHA HA THORA DAKHA DIGEA Please
Kya alarm aa raha h
Sir inverter overload ka alram aa raha hai kya kar
Check motor or motor amp
please how can reset alarm A68 and alarm A88
Al 046
Sir danfoos micro driver fc51 ka alarm 8 kasay clear ho ga baata da pleas
Ye alarm permanently aa ràha h ki jb drive off krte hai
Same problem sir regular aa raha hai al8 ka alarm reset krna pdta hai bar bar
Batao bhai
Sir error 17 ka solution bataye detail mee??
Reset factory settings
Sir vlt fc 51 alarm 11 how to reset
Motor heat ho raha h
Check motor windings.. or motor load
A9 aa raha hai uska Kiya kare
Motor over load ka massage hai.