Restaurant Kitchen Hood Fan Not Working Properly, Repaired!

แชร์
ฝัง
  • เผยแพร่เมื่อ 13 ธ.ค. 2024

ความคิดเห็น • 25

  • @joshL2813
    @joshL2813 20 วันที่ผ่านมา +1

    Check the rotation
    captive air I believe runs CCW looking down. Can also look at the blade if it is a different manufacturer

  • @DrHounkpati
    @DrHounkpati 8 หลายเดือนก่อน

    Thanks for sharing. Impressive.

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  8 หลายเดือนก่อน

      Thanks

    • @enviroclean7734
      @enviroclean7734 6 หลายเดือนก่อน

      Hey I replace the motor but it cuts off every 15 minutes

  • @l.crossjr
    @l.crossjr 9 หลายเดือนก่อน

    Nice one. How can you tell how much airflow is being extracted?

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  9 หลายเดือนก่อน +1

      Yea would need to use anemometer or better know as an air flow meter to get an exact measurement.

  • @jrh86
    @jrh86 ปีที่แล้ว +1

    😃👍👍👍

  • @cambodianangler9052
    @cambodianangler9052 7 หลายเดือนก่อน +1

    Hello my friend, I don’t know why my motor that I just replace, it’s running a few minute then it stop, then it running again and again like that! Can u tell me why??

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  7 หลายเดือนก่อน +1

      It’s most likely over amping due to the adjustable pulley or the belt being too tight. You will need an amp probe to check how many amps the motor is pulling and cross it to how many amps the motor is rated for printed on the data plate of the motor.

    • @cambodianangler9052
      @cambodianangler9052 7 หลายเดือนก่อน

      @@JeffsHVACAdventures it’s hard for me then,

    • @cambodianangler9052
      @cambodianangler9052 7 หลายเดือนก่อน

      @@JeffsHVACAdventures thanks , I will try

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  7 หลายเดือนก่อน

      You will most likely need to hire an hvac or restaurant equipment repair person to take a look.

    • @cambodianangler9052
      @cambodianangler9052 7 หลายเดือนก่อน

      @@JeffsHVACAdventures my old one is GE 3/4 hp115v-230v 1ph , then I replace to Marathon 3/4 115V-208-230V 1ph. You think it’s should be alright? Ask I told u it worked, but it’s running for short time then stop, then it’s keep running again after a few minutes

  • @brothermine2292
    @brothermine2292 ปีที่แล้ว

    This wouldn't fix the hood in my kitchen's stove/oven. Although the plans for our condo building show ducts from each kitchen to roof exhaust fans, the builder didn't install the ducts, and each kitchen hood just ineffectually circulates the air within the kitchen.

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  ปีที่แล้ว

      Hope they get that straightened out for you. Sounds like pain.
      This video is more for restaurant kitchen hoods. Thanks for watching!

    • @brothermine2292
      @brothermine2292 ปีที่แล้ว

      @@JeffsHVACAdventures : No, the building is about 50 years old, and during my 13 years living here I haven't heard any residents complain that ducts ought to be installed. I only mentioned it here for its amusement value.

    • @come_on_now
      @come_on_now 11 หลายเดือนก่อน

      ​@@brothermine2292 oboy man... I was just on one yesterday... the homeowner purchased this 50 plus year old home 5 years ago and the previous owner redid the air conditioning equipment...
      The contractor installed 3 systems.
      2 are standard split forced air furnace and AC.
      the 3rd is an air handler which requires a heat pump for the heat mode... the installed straight ac on that one too... question... how did it go unnoticed for 10 years and 2 home owners? It does serve the top 3rd floor so, Maybe they don't require much heat up there... who knows... but it's happened several times in my career.
      Crazy

  • @orlandoarteaga6144
    @orlandoarteaga6144 4 หลายเดือนก่อน

    Deje ver lo q haces por favor

  • @come_on_now
    @come_on_now 11 หลายเดือนก่อน

    If that was a direct motor replacement, it was not setup correctly from the getgo. Nice work.

  • @darkangelhatesyou
    @darkangelhatesyou 5 หลายเดือนก่อน

    Question, ours while it’s on, it’ll randomly turn off. After 20 min it’ll start back up

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  5 หลายเดือนก่อน +1

      Sounds like it’s turning off on thermal overload. The Thermal overload is an internal safety switch inside the motor to protect itself from abnormal operation. This could be due to a number of different things. Dirty filters or blower wheel, faulty belt or belt tension, improperly adjusted pulley… etc. I would start by making sure everything is clean. If all is clean then I would recommend calling a professional to properly evaluate the unit. 🤙

    • @darkangelhatesyou
      @darkangelhatesyou 5 หลายเดือนก่อน

      @@JeffsHVACAdventures thank you for your quick response! Also, it makes a noise. Maybe a pulley?