Kitchen Hood Suppression System Maintenance Explainer Video (Argus Fire)

แชร์
ฝัง
  • เผยแพร่เมื่อ 20 ส.ค. 2024

ความคิดเห็น • 30

  • @Digitaltarangs
    @Digitaltarangs 6 หลายเดือนก่อน

    Great,
    Thanks for sharing knowledge...

  • @EricPham-gr8pg
    @EricPham-gr8pg 9 หลายเดือนก่อน

    Thank you for teaching us

  • @pressurewashingandhoodcleaning
    @pressurewashingandhoodcleaning 9 หลายเดือนก่อน +1

    why do you have all those lights?

  • @agray007
    @agray007 ปีที่แล้ว +1

    what type licensing is required for this type of inspection?

  • @cucinacapresemonaco9932
    @cucinacapresemonaco9932 ปีที่แล้ว

    Hallo wean the system get tasted and the gas shot off but not the power what is that mean? thank you for your Time

  • @abdulmajeeth3135
    @abdulmajeeth3135 ปีที่แล้ว

    Thanks👍🏻

  • @ahmedalhourani4603
    @ahmedalhourani4603 6 หลายเดือนก่อน

    how i can flush the system after discharge

  • @jitinyadav6507
    @jitinyadav6507 ปีที่แล้ว

    I want to know the refilling time period of fire suspension system

  • @johnn2557
    @johnn2557 2 ปีที่แล้ว

    He also did not test the water flow connection for proper pressure and check the water valve in in the locked open position.

    • @davem287
      @davem287 ปีที่แล้ว +1

      He clearly wasn't going to show every detail it's a customer demo not a training video

    • @fF-jb4gs
      @fF-jb4gs 10 หลายเดือนก่อน

      Looks like a training facility by the looks of the extremely clean appliances

  • @hemandersingh4502
    @hemandersingh4502 ปีที่แล้ว

    Hello sir
    Which gas cartridge is this and at what temprature the fuseable link breaks ??

  • @marks7352
    @marks7352 ปีที่แล้ว

    Does it cost money for the system to be inspected?

  • @annmccormick
    @annmccormick 8 หลายเดือนก่อน

    Judge Judy

  • @patienceiskey8181
    @patienceiskey8181 ปีที่แล้ว

    What size is this?

    • @fF-jb4gs
      @fF-jb4gs 10 หลายเดือนก่อน

      3 gallon

  • @mdbb7202
    @mdbb7202 2 ปีที่แล้ว +1

    Umm I hope this ain't a training video. The pull station is too high up. It looks like you are using a small pair of channel locks not the right pliers. What kind of break rod is that? And put a test link in instead of cutting the actual detector. You didn't blow out the distribution line with air.

    • @davem287
      @davem287 ปีที่แล้ว +1

      It's clearly a customer demo, he's talking to the customer end. The pull station location is probably the customers choice which is fine, Authority having jurisdiction I.e. the owner can specify the location.
      Nothing wrong with not using a test link nor anything wrong using a small pipe grips for the scissor links.
      Typical snob engineer trying to shoot down another guys work, I've met plenty like you and let me tell you they are the worst offenders when in comes to compliance. So you know some regulations big deal !! These systems aren't rocket science !

    • @paullistokin9736
      @paullistokin9736 10 หลายเดือนก่อน +1

      Customer's choice? Nowhere in NFPA 17A or IMC, IBC, ICC, or even in the Ansul (the manufacturer) manual will it allow for a location other than 48" from finished floor. Customer can choose where the pull station goes as far as kitchen location as long as the installer and/or AHJ will allow, but never alter in height.

    • @Carti2official
      @Carti2official 9 หลายเดือนก่อน +2

      Customer does not get a choice in the height of the pull station. No more than 48 inches from the ground. NFPA code, Ansul specifications. Done hundreds of finals with AHJ, fire Marshals and Mechanical inspectors. Same code for fire alarm pull stations.

  • @nazreatweldeyohannes3334
    @nazreatweldeyohannes3334 11 หลายเดือนก่อน

    I need new

  • @pressurewashingandhoodcleaning
    @pressurewashingandhoodcleaning ปีที่แล้ว

    manual pull station is to high.

    • @davem287
      @davem287 ปีที่แล้ว

      Customers choice

    • @Carti2official
      @Carti2official 9 หลายเดือนก่อน +1

      @@davem287customer doesn’t get a choice. No more than 48 inches from the ground is the code.

  • @sarwarkarim2921
    @sarwarkarim2921 2 ปีที่แล้ว

    Great to see you sir i want to connect you so please can i have your email address
    I'm also fire fighting technician

  • @Carti2official
    @Carti2official 9 หลายเดือนก่อน +1

    That system is well beyond the allowed flow points😂😂😂. You’ve said nothing about nozzle coverage or anything. That’s Ansuls overlapping coverage. Do Better

    • @iGotSoldAgain
      @iGotSoldAgain 9 หลายเดือนก่อน

      well it's a piranha system. could easily be a 13 tank. each nozzle has 1 flow and could very easily have be enough flows on the cylinder

    • @iGotSoldAgain
      @iGotSoldAgain 9 หลายเดือนก่อน

      also, all piranha systems are total flood